Description
Dionex / ThermoFisher
FLM:
Temperature range: 5–70 °C (max. 15 °C below ambient temperature)
Temperature accuracy: ±0.5 °C
Temperature stability: ±0.1 °C
Temperature precision: ±0.1 °C
Column capacity: Up to 3 columns, max. 30 cm length
Heating time: From 20 to 50 °C in less than 25 min (at 23 °C ambient temperature, ±0.5 °C)
Cooling time: From 50 to 20 °C in less than 35 min (at 23 °C ambient temperature, ±0.5 °C)
Control: All functions software-controlled via USB 1.1
I/O interfaces: 2 digital inputs, 2 programmable relay outputs
Column recognition: Electronic identification system for 3 columns
Switching valves: 1 or 2 thermostated microvalves with low dispersion (10 ports or 6 ports)
Flow splitter: Nano, capillary, or thermostated micro-flow splitter with flow splitter identification system
Flow control: Electronically controlled and actively balanced flow splitter, independent of solvent composition and backpressure
Column flow range: 50 nL/min to 2.5 mL/min using a predefined splitter and active flow control
Flow range selection:
50 nL/min to 1,000 nL/min (using a Nano-LC splitter)
0.5 μL/min to 10 μL/min (using a capillary LC splitter)
10 μL/min to 160 μL/min (using a micro-LC splitter)
Hjdpfx Aoxtb Efsb Ujfr
Gradient delay time: Typically 600 nm.
Noise:
At a wavelength:
The listing was translated automatically. Translation errors are possible.
FLM:
Temperature range: 5–70 °C (max. 15 °C below ambient temperature)
Temperature accuracy: ±0.5 °C
Temperature stability: ±0.1 °C
Temperature precision: ±0.1 °C
Column capacity: Up to 3 columns, max. 30 cm length
Heating time: From 20 to 50 °C in less than 25 min (at 23 °C ambient temperature, ±0.5 °C)
Cooling time: From 50 to 20 °C in less than 35 min (at 23 °C ambient temperature, ±0.5 °C)
Control: All functions software-controlled via USB 1.1
I/O interfaces: 2 digital inputs, 2 programmable relay outputs
Column recognition: Electronic identification system for 3 columns
Switching valves: 1 or 2 thermostated microvalves with low dispersion (10 ports or 6 ports)
Flow splitter: Nano, capillary, or thermostated micro-flow splitter with flow splitter identification system
Flow control: Electronically controlled and actively balanced flow splitter, independent of solvent composition and backpressure
Column flow range: 50 nL/min to 2.5 mL/min using a predefined splitter and active flow control
Flow range selection:
50 nL/min to 1,000 nL/min (using a Nano-LC splitter)
0.5 μL/min to 10 μL/min (using a capillary LC splitter)
10 μL/min to 160 μL/min (using a micro-LC splitter)
Hjdpfx Aoxtb Efsb Ujfr
Gradient delay time: Typically 600 nm.
Noise:
At a wavelength:
The listing was translated automatically. Translation errors are possible.
Seller
Note: Register for free or log in, to access all information.
Registered since: 2012
Send inquiry
Telephone & Fax
+49 2861 ... show
These listings may also fit your interest.
Listing
Győr
1,683 km
HPLC system w/ software - please read!
Agilent1100
Agilent1100
Listing
Duxford
436 km
Agilent Cary 1260 infinity HPLC system
Agilent Cary1260 infinity
Agilent Cary1260 infinity
Listing
Borken
785 km
Mass spectrometer (spare parts dispenser)
SCIEXAPI 4000
SCIEXAPI 4000
Listing
Marthalen
1,199 km
Table scale
Mettler ToledoMB60S
Mettler ToledoMB60S
Your listing has been deleted successfully
An error has occurred