Switchgear transformer stationHorlemann
HR10U-S
Switchgear transformer station
Horlemann
HR10U-S
ONO plus VAT
€10,500
Year of construction
2010
Condition
Used
Location
Borken 

Machine data
- Machine type:
- Switchgear transformer station
- Manufacturer:
- Horlemann
- Model:
- HR10U-S
- Year of construction:
- 2010
- Condition:
- good (used)
Price & Location
ONO plus VAT
€10,500
- Location:
- Dunkerstrasse 29, 46325 Borken/Burlo, Deutschland

Call
Details about the offer
- Listing ID:
- A11682548
- Reference number:
- 29365
- Update:
- 16.02.2026
Description
Horlemann HR10U-S Switchgear 12 kV
HR 10U: the universal switchgear for industry and utilities
Modular medium-voltage switchgear for solar power distribution
Switchgear:
Manufacturer: Horlemann
Circuit: KKÜHTTT
Type: HR10U-S
Rated voltage: 12 kV
Rated current: 630 A
Short-circuit capacity: 20 kA/1s
Height: 2060 mm
Width: 1300 mm
Depth: 800 mm
Cell width: 7 x 650 mm
Busbar: AL 50 x 10 mm
Weight: approx. 620 kg
Rated data HR10U:
Ur: 12 kV Ir: 630 A
Up: 75 kV Ik: 20 kA (1s)
Ud: 28 kV IP: 50 kA
Fr: 50 Hz IAC: AFL 25 kA (1 s)
IP: IP4X
According to IEC-62271-200 (VDE 0671-200); 2003-11
TMC Cast Resin Transformer:
Design: Cast Resin
High Voltage: 10 kV
Low Voltage: 400-230 V
Circuit: Dyn5
Year of Construction: 2010
Height: 1740 mm
Width: 1300 mm
Depth: 900 mm
Weight: 1.8 t
The switchgear is pressure-relieved via a pressure-relief chamber in the lower part of the switchgear panel.
Documents:
Test Report
Circuit Diagram
Hfedpfx Aisnfu Dyorjl
Financing through our bank is also possible.
komplett-konzept.leasingo.de
You can find more items - new and used - in our shop!
International shipping costs on request!
HR 10U: the universal switchgear for industry and utilities
Modular medium-voltage switchgear for solar power distribution
Switchgear:
Manufacturer: Horlemann
Circuit: KKÜHTTT
Type: HR10U-S
Rated voltage: 12 kV
Rated current: 630 A
Short-circuit capacity: 20 kA/1s
Height: 2060 mm
Width: 1300 mm
Depth: 800 mm
Cell width: 7 x 650 mm
Busbar: AL 50 x 10 mm
Weight: approx. 620 kg
Rated data HR10U:
Ur: 12 kV Ir: 630 A
Up: 75 kV Ik: 20 kA (1s)
Ud: 28 kV IP: 50 kA
Fr: 50 Hz IAC: AFL 25 kA (1 s)
IP: IP4X
According to IEC-62271-200 (VDE 0671-200); 2003-11
TMC Cast Resin Transformer:
Design: Cast Resin
High Voltage: 10 kV
Low Voltage: 400-230 V
Circuit: Dyn5
Year of Construction: 2010
Height: 1740 mm
Width: 1300 mm
Depth: 900 mm
Weight: 1.8 t
The switchgear is pressure-relieved via a pressure-relief chamber in the lower part of the switchgear panel.
Documents:
Test Report
Circuit Diagram
Hfedpfx Aisnfu Dyorjl
Financing through our bank is also possible.
komplett-konzept.leasingo.de
You can find more items - new and used - in our shop!
International shipping costs on request!
Seller
Note: Register for free or log in, to access all information.
Registered since: 2008
589 listings online
Send inquiry
Telephone & Fax
+49 2862 ... show
These listings may also fit your interest.
Listing
Germany
1,006 km
DMG MORI CTX Beta 800 4a
DMG MORICTX Beta 800 4a
DMG MORICTX Beta 800 4a
Listing
Stutensee
1,069 km
Press container
Allpress RIES10 cbm Absetzpresse
Allpress RIES10 cbm Absetzpresse
Listing
Borken
783 km
Vacuum pump screw pump
BuschCobra NC 0630 B + WV 2000 C
BuschCobra NC 0630 B + WV 2000 C
Listing
Germany
866 km
Bar Automatic Lathe - Multi Spindle
SCHÜTTEAF51
SCHÜTTEAF51
Listing
Suffolk
442 km
Spiral freezer
JBT FrigoscandiaGYRoCOMPACT 600 Classic 34 tiers
JBT FrigoscandiaGYRoCOMPACT 600 Classic 34 tiers
Listing
Bocholt
772 km
Vacuum pump stand
LeyboldTrivac D65B & WAU 251
LeyboldTrivac D65B & WAU 251
Listing
Warstein
897 km
50,000 liter heating oil / oil tank diesel tank
Wozniack50.000 Liter Tank nach EN 12285-2 Norm
Wozniack50.000 Liter Tank nach EN 12285-2 Norm
Listing
Hessisch Oldendorf
906 km
Nitrogen Generator
Atlas CopcoPSAL-SN AIRCO PLUG & PLAY
Atlas CopcoPSAL-SN AIRCO PLUG & PLAY
Listing
Berlin
1,143 km
Press Feeding System
CoiltecCOMPACT FEEDER CMKS H3
CoiltecCOMPACT FEEDER CMKS H3
Listing
Velen
787 km
Cold Circular Saw
BERG & SCHMIDPERFECT 300
BERG & SCHMIDPERFECT 300
Your listing has been deleted successfully
An error has occurred