Used Chamber Pasteurizer for sale (2,376)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
785 km
Climatic chamber -75°C / +180°C with humidity control
TIRATCC 7120
Call
Condition: excellent (used), TIRA
Type: TCC 7120
Temperature range: -75°C / +180°C
Air-cooled condenser
Temperature stability (over time and in the center of the usable space): ±0.1°C ... ±0.3°C
Maximum temperature change rate:
Heating: 4°C/min
Cooling: 3°C/min
Humidity range: 10% to 98% relative humidity
Humidity stability over time: ±1% to ±3%
Dew point range during long-term tests: +2 / +94 °C
Dew point range during short-term tests: -20 / +2 °C
External dimensions (L x W x H): 1320 x 2235 x 2137 mm
Test chamber dimensions (L x W x H): 1000 x 1130 x 1020 mm
Test chamber volume: approx. 1152 liters
Max. load per shelf: 50 kg
Maximum floor load of the test chamber: 100 kg
Refrigerant: R404A and R23
Power supply: 400V + 6%/-10% / 50Hz / 3P+N+PE
Rated power: 10.2 max. 17.5 kW
Rated current: 19.5 max. 32.0 A
Njdezh Htqepfx Akcewi
Noise level: approx. 80 dB(A)
Weight: 1180 kg
For your security as a buyer, please note the following:
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will be subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and specifications are subject to change!)
We will gladly answer any further questions you may have by phone.
Listing
Borken
785 km
Thermal shock chamber, 200 liters
EspecTSA-202E-W -55°C bis 200°C
Call
Condition: excellent (used), Espec
Type: TSA-202E-W
Temperature shock chamber, water-cooled
Cold chamber: -55°C to 0°C
Hot chamber: +50°C to 200°C
System: Two-zone testing via damper control
Temperature fluctuation: ±0.5°C
Hot chamber:
Temperature: Heating time: from ambient temperature (20°C) to +200°C within 15 minutes.
Cold chamber:
Temperature: Cooling time: from ambient temperature (20°C) to -55°C within 35 minutes.
Temperature: Recovery time: within 5 minutes.
Internal dimensions (W x H x D mm): 650 x 460 x 670
External dimensions (W x H x D mm): 1550 x 1900 x 1670
Approx. 200 liters
Power supply: 400 V AC 50Hz: 65 A
Nedpfx Akezh Htkscowi
Refrigerant: R404A 5 kg, R23 2.0 kg
Weight: approx. 1200 kg
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by phone.
Listing
Borken
785 km
Temperature test chamber spray device
VötschVBT 03/500 500 Liter -30 bis 80°C
Call
Condition: excellent (used), Vötsch
Type: VBT 03/500
Air-cooled
Temperature test chamber with spray device
Technical description:
Data for temperature tests without water:
Temperature range -30°C to +80°C
Temperature deviation in the stabilized state
according to IEC 60068-3-5, depending on the test chamber temperature
± 1 K over time
Temperature change rate according to IEC 60068-3-5
Heating: approx. 2 K/min.
Cooling: approx. 2 K/min.
Data for temperature tests with water
Temperature range +5°C to +80°C
Possible water level -10 mm to 540 mm
Water level = -10 mm
The water level is below the support grid
Water level = 0 mm
The water level is at the top edge of the support grid
Data for spray device, standard
Number of spray nozzles 6
Spray volume per nozzle 0.5 l/min
Data for spray device according to EN 539-2, Method B
Number of spray nozzles 6
Spray volume per nozzle 4.5 l/min
Additional flooding nozzles 2
Spray volume additional nozzle 6 l/min
Compressed air consumption approx. 3 m³/h
Data for water tank with preheating
Volume approx. 2000 l
Temperature range for preheating +5°C to +40°C
Temperature change duration
Cooling from +18°C to +5°C approx. 15 h
Heating from +15°C to +40°C approx. 10 h
Data for installation and operation:
Test chamber: Width 1120 mm, Depth 840 mm, Height 540 mm
Housing: Width 2700 mm, Depth 1300 mm, Height 1575 mm
Water tank: Width 1100 mm, Depth 800 mm, Height 2200 mm
Feedthroughs
1 feedthrough ∅ 50 mm, installed on the left
Test chamber volume: approx. 500 liters
Refrigerant R-404a
Nwodpozh D S Rjfx Akcoi
Electrical connection:
Rated voltage 3/N/PE AC 400V ± 10% 50Hz
Rated power approx. 26 kW
Rated current approx. 44.0 A (neutral conductor loaded)
Fuse 63 A gG, on-site
Weight approx. 890 kg net
For your safety as a buyer, the following information!
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will be subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data and specifications are subject to change!)
We will gladly answer any further questions you may have over the phone.

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing
Borken
785 km
Climate test chamber temp. -70 to 180°C
Weiss explosionsgeschütztWK-600/70 (I)-(II) 2 G EEx
Call
Condition: excellent (used), Weiss
Type: WK-600/70 (I)-(II) 2 G EEx /22605147
Weiss Climate Chamber, Water-Cooled
(Test chamber, explosion-proof)
INERTIZATION WITH NITROGEN / EXPLOSION-PROOF TEST CHAMBER
Technical Data:
Test chamber designation: WK-600/70 (I)-(II) 2 G EEx
External dimensions with hinges and door lock:
Height 1995 mm, Width 1090 mm, Depth 1660 mm
External dimensions without hinges and door lock:
Height 1995 mm, Width 1000 mm, Depth 1660 mm
Test chamber volume: approx. 600 liters
Cold/Heat operation: -70 to 180°C
Climate operation: 10 – 95°C
Humidity: 10...98 % RH
Temperature change per unit of time:
Cooling: approx. 2.5 K/min
Heating: approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 14 kW
Rated current: 25 A
Fuse (on customer's side): 32 A, slow-blow
Permissible weight of test specimens:
Total load of the shelf supports: 80 kg
Test chamber floor: 80 kg, insert shelf: 40 kg
Weight: 800 kg
Refrigerant: R 404A/R 23
(Evaporator of the air conditioning system has been replaced)
For your safety as a buyer, please note the following information!
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
Nsdpfx Akezh D Ryocjwi
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by phone.
Listing
Borken
785 km
Climate chamber 138 liters
CLIMATSEXCAL 1413-HA -40 bis 180°C
Call
Condition: excellent (used), Climate chambers
Type: EXCAL 1413-HA
Air-cooled climate chamber
EXCAL is equipped with a 15-inch capacitive multi-touch panel PC, SSD storage, Windows 7, and 2 USB ports.
This makes it state-of-the-art.
Technical data:
Test chamber dimensions: Width 550 mm x Depth 500 mm x Height 500 mm
Housing dimensions: Width 820 mm x Depth 1375 mm x Height 1730 mm
Window 350 x 380
Volume: 138 liters
Feedthrough installed as standard
R1: 80 mm ∅
L1: 80 mm ∅
Data for temperature tests:
Temperature range: -40°C to +180°C
Temperature deviation over time ± 0.1 to ± 0.3 K
Temperature homogeneity spatially ± 0.5 to ± 1.8 K
Temperature change rate
Nwodpfx Akozh D Rtscsi
Heating: 15 K/min
Cooling: 10 K/min
Data for climate tests:
Temperature range +10 to +90 °C
Humidity range 10 to 98 % RH
Data for operation:
3/N/Ph+T 400V ±10% 50 Hz
Rated power 9.8 kVA
Refrigerant R-404A / R-23
Weight: 430 kg
For your peace of mind as a buyer, please note the following:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and information are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Listing
Borken
785 km
Spray and splash water test chamber
WeissSWT 200/400
Call
Condition: excellent (used), Weiss
Type: SWT 200/400
Weiss spray and splash water test cabinet
This cabinet is used to test the ingress of water into enclosures.
In conjunction with a timer, the test cycle can be automated with an adjustable test time from 3 seconds to 30 hours.
Complies with DIN VDE 0470 T1 or EN 60529 for tests according to protection classes IPX3 and IPX4.
The integrated circulation system can reduce water consumption to a minimum.
Features
Glass door with wiper
Pneumatic drive of the swivel nozzle
Adjustable swivel angle
Replaceable swivel nozzles
Nozzle holder swivels and is replaceable
Adjustable water flow rate and measurement
Control of the test duration
Data for mechanical stress
Max. load with test specimen (evenly distributed over the area)
Permissible test specimen weight for the test specimen holder (total) 25 kg
Spray radius 200 mm / 400 mm
Data for IP protection class tests
Swivel speed approx. 60°/s
Swivel angle IPX3 approx. ± 60°
Swivel angle IPX4 approx. ± 180° -10°
Dimensions:
Nsdpfx Akjzh D Rmscjwi
External dimensions with control cabinet (D x W x H) approx. 1000 x 1350 x 1,900 mm
External (D x W x H) approx. 1000 x 1000 x 1,900 mm
Internal dimensions (D x W x H) 400 x 650 x 750 mm
Operating data
Voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power 1.5 kW
Rated current 6.0 A
Weight: 375 kg
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We would be happy to answer any further questions you may have by telephone.
Listing
Borken
785 km
Temperature shock test chamber
WeissTS 130
Call
Condition: used, Weiss
Type: TS 130
Temperature shock test chamber, water-cooled
Specification:
Temperature range, hot chamber: +60°C … +220°C
Temperature range, cold chamber: -10°C … -80°C
Hot/cold chamber changeover: 10 sec.
Temperature stability: ±1 K
Dimensions and other data:
External dimensions: Height 1990 mm
Width (without and with door hinge): without... approx. 1820 mm, with... approx. 1850 mm
Depth (without and with test chamber door): without... approx. 900 mm, with... approx. 1155 mm
Dimensions of the lifting platform (test chamber): Height 450 mm, Width 500 mm, Depth 600 mm
Volume: 130 liters
Test chamber load: max. 20 kg
Load on the test chamber floor: max. 20 kg
Cooling water pressure: min. 2 ... max. 6 bar
Max. fuse rating: 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of the unit: approx. 65 dB(A)
Refrigeration cascade, water-cooled
Nwsdpfx Aozh D N Askcoi
Connection values: 3/N/PE/AC 400V ±10% 50Hz / 14.0 kW
Rated current: 26.0 A
Refrigerant: R 404A / R23
Weight: approx. 950 kg
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by telephone.
Listing
Borken
785 km
Temperature test chamber 600 liters
CTST-70/600/S 70°C bis 180°C
Call
Condition: good (used), CTS
Type: T-70/600/S
Water-cooled temperature testing chamber
Refrigerant: Converted to R-452A
Control:
- 32-bit controller
- LCD control panel
- Digital display of setpoint and actual values
- Numerical input of setpoints
- Error messages in plain text
- RS 232 interface
- Free switching channels for on-site control of the test item
Technical performance data
Temperature tests:
Temperature range -70 °C to +180 °C
Temperature deviation ±0.1 to ±0.3 K over time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 2.5 K/min
Heat radiation
approx. 2500 W at +20 °C
approx. 2500 W at +0 °C
approx. 1800 W at -40 °C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400 V, without test item, without radiation, and without additional equipment.
Dimensions:
Test volume 600 liters
Nwodpfx Akozh D E Rscei
Test chamber dimensions: height, approx. 850 mm, width, approx. 850 mm, depth, approx. 830 mm
External dimensions: height, approx. 1900 mm, width, approx. 1120 mm, depth, approx. 1875 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 8.8 kW
Rated current 14.8 A
Protection class IP 22
Weight approx. 700 kg
Refrigerant: R-452A / R23
Weight: 700 kg
For your security as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have on the phone.
Listing
Menslage
797 km
Hermis TP Tunnel Pasteurizer (2025)
HermisTunnelpasteur
Call
Condition: used, Year of construction: 2025, OVERVIEW
This Hermis TP-HRW 20 stainless steel tunnel pasteurizer is a new and unused machine, manufactured in 2025, designed for the pasteurization of beer in 500 ml bottles. The pasteurizer has a capacity of approx. 20,000 bottles per hour and is configured as a 10-zone tunnel pasteurizer with heating, pasteurization and cooling sections.
The machine is fully made of stainless steel AISI 304 and is equipped with an external plate heat exchanger for the heating system. The process is controlled by a Siemens S7-1200 PLC with a Siemens Simatic 12" HMI touch panel, allowing automatic control of the pasteurization process. The system is designed for a product inlet temperature of approx. +4°C, a pasteurization temperature of approx. +62°C to +64°C, and an outlet temperature of approx. +34°C to +35°C.
The pasteurizer provides a total treatment area of approx. 74 m², with a treatment length of approx. 13.5 m and a total machine length of approx. 15.3 m. The complete process cycle is approx. 45 minutes, achieving approx. 24 PU based on the given 500 ml beer bottle configuration.
Nwedpfx Aoy Ul Dwskcoi
TECHNICAL DATA
- Manufacturer: Hermis
- Model: TP-HRW 20
- Machine Type: Stainless steel tunnel pasteurizer
- Condition: New, never used
- Year of Manufacture: 2025
- Product: Beer
- Container Format: 500 ml bottles
- Capacity: approx. 20,000 bottles/hour
- Treatment Area: approx. 74 m²
- Number of Modules: 7 pcs
- Total Number of Zones: 10 zones
- Zone Configuration: heating, pasteurization and cooling zones
- Treatment Length: approx. 13,500 mm
- Dimensions: approx. 15,300 x 5,900 x 2,200 mm
- Total Length incl. infeed / discharge conveyor: approx. 15,000 mm
- Main Construction: Stainless steel AISI 304
- Heating System: Plate heat exchanger outside the pasteurizer
- Steam Pressure: approx. 3 bar
- Pasteurization Temperature: approx. +62°C to +64°C
- Product Inlet Temperature: approx. +4°C
- Product Outlet Temperature: approx. +34°C to +35°C
- Pasteurization Time: approx. 10–11 minutes
- Total Cycle Time: approx. 45 minutes
- Pasteurization Units: approx. 24 PU
- Water Consumption: approx. 2.2 – 3.0 m³/h during stable operation
- Water Volume in Pasteurizer: approx. 6,600 l
- Steam Consumption: approx. 790 kg/h during stable operation; approx. 1,250 kg / 30 min during start-up
- Steam Temperature: approx. +143°C at 4 bar
- Power Supply: 400 V AC, 3/N/PE, 50 Hz
- Control System: Siemens S7-1200
- HMI: Siemens Simatic 12" touch panel
- Main Conveyor: Plastic conveyor by Movex
- Active Transfer: Rexnord
- Plate Heat Exchanger: Funke
- Pumps: Stainless steel pumps by Lowara
- Spray Nozzles: Lechler
- Steam Valve: Bürkert
- Air Supply System: SMC
- Level Sensors: Endress+Hauser / Negele
- Temperature Registration: Endress+Hauser
- Temperature Sensors: Negele
- Included Features: Automatic pasteurization control, ECO graph / data logger, stainless steel electrical cabinet, air conditioner for electrical cabinet
Listing
Menslage
797 km
Krones / APV - Flash Pasteurizer (2001)
Krones / APVKurzzeiterhitzung KZE
Call
Condition: used, Year of construction: 2001, Overview
This flash pasteurizer was manufactured in 2001 by German company Krones / APV. The unit was previously operated in a mineral water production facility in Germany. Following the replacement of the complete line, the machine was dismantled and sold individually. It is available immediately and currently in stock. The reason for sale is a line upgrade.
Technical data
- Type: Flash pasteurizer (short-time heating system)
- Application: Alcohol-free beverages / mineral water
- Capacity:
- Guaranteed throughput up to 22,000 l/h
- Adjustable down to 10,000 l/h
- Process design:
- Plate heat exchanger with regeneration, heating, degassing and cooling sections
- Integrated degassing unit
- Buffer tank with internal circulation
- Electrical connection:
- 230 / 400 V, 3 Ph, 50 Hz
- Control voltage: 24 V DC
- Execution:
- Stainless steel construction
- CE-compliant according to EU machinery directives
Nsdpfx Akeyb Sw Ascjwi
- Control & instrumentation:
- Measurement and control technology
- PLC-based control system
- Electrical cabinet
- Interfaces:
- Mechanical and electrical interfaces according to Krones / APV standards
Listing
Trittau
913 km
Washing Unit - Chamber
SUGINO ZIPPELZD-4.000-RAST
Call
Condition: used, Year of construction: 2015, Dimensions (L/W/H) ca. 4020 x 2460 x 2600 mm
total power requirement 78 kW
filling amount 1200 l
carrying capacity max. 0,5
Nwjdpfx Akjzkbpxocji
bath temperature 65 °C
heating capacity 54 kW
In our opinion, the machine is in good used condition
and can be inspected under power by appointment.
Accessories, tools and clamping devices shown are only part of the scope of
delivery
if this is noted in the additional information.
Changes and errors in the technical data and information as well as
Subject to prior sale!
Listing
Wiefelstede
785 km
Chamber filter press
Poligrat470-20/2
Call
Condition: good (used), Year of construction: 1988, Reaction vessel, batch system, solids separator, washing trough, painter's wash station, water treatment, tool and water cleaning, filter press, chamber filter press
-Manufacturer: Poligrat, chamber filter press type 470-20/2
Nedpfehvfznsx Akcowi
-Model: 11 plates
-Hydraulic cylinder: Stroke: 115 mm
-Dimensions: 1315/920/H1720 mm
-Weight: 580 kg
Listing
Borken
785 km
Thermal Shock Chamber 72 Liter
Espec TemperaturschockprüfschrankTSA-72EL-A -65°C bis +200°C
Call
Condition: excellent (used), ESPEC TSA-72EL-A Temperature Shock Chamber
Manufacturer: ESPEC Corporation
Type: TSA-72EL-A
Machine Type: Temperature Shock Chamber / Thermal Shock Chamber (2-Zone)
Design: Water-cooled
For sale is a used ESPEC temperature shock chamber, type TSA-72EL-A.
This unit is suitable for reproducible temperature cycling and thermal shock testing in
research, development, quality assurance, as well as for testing electronics, automotive components, aerospace parts, and materials.
The switchover between the hot and cold chambers is performed automatically via a 2-zone damper system.
Technical Data
Test chamber volume: approx. 70 liters
Internal dimensions (W x H x D): 410 x 460 x 370 mm
External dimensions (W x H x D): 1,310 x 1,900 x 1,470 mm
Weight: approx. 900 kg
Temperature range, hot chamber: +50 °C to +200 °C
Temperature range, cold chamber: -65 °C to 0 °C
Temperature stability: ±0.5 °C
Preheating temperature: up to +205 °C
Precooling temperature: up to -75 °C
Heating time: ambient temperature to +200 °C within approx. 15 minutes
Cooling time: ambient temperature to -70 °C within approx. 40 minutes
Temperature recovery time: ≤ 5 minutes
Max. test load: 30 kg evenly distributed
Cable entry: Ø 50 mm
Compressed air supply: 0.4 to 0.7 MPa (4 to 7 bar)
Refrigeration system / Power supply
Refrigeration system: Mechanical cascade refrigeration system
Refrigerant, high-temperature side: R404A
Refrigerant, low-temperature side: R23
Condenser: Water-cooled
Mains connection: AC 380 / 400 / 415 V
3 phases / 50 Hz
Nwodozhkfqjpfx Akcei
Max. current draw: 45 A
Equipment
10.4" TFT color touchscreen
PID temperature control
Program memory (RAM/ROM)
Trend graph
Alarm history
RS-485 interface
Eco mode
Automatic defrost
Vertical sliding door
Stainless steel test chamber
2 stainless steel test inserts
Mechanical cascade refrigeration system
Electronic expansion valve
Sirocco circulation fan
Pneumatic damper switchover
Cable entry Ø 50 mm
Applications
Temperature shock testing
Temperature cycling testing
Electronics testing
Semiconductor testing
Automotive
Materials testing
Component testing
Quality assurance
Research and development
Condition
Used
Optical condition as shown in the pictures.
Scope of supply
ESPEC TSA-72EL-A Temperature Shock Chamber
2 stainless steel test inserts
Accessories as shown in the pictures
Scope of supply as pictured.
Subject to change, errors and prior sale.
Listing
Remscheid
846 km
Temperature cabinet, climate chamber
WEISSKWP-64/75
Call
Year of construction: 2004, condition: good (used), functionality: fully functional, For sale is a temperature testing cabinet from the brand Weiss, in good, used condition, as can be seen in the pictures.
Technical data:
Nodpfozmaa Ujx Akcewi
• Manufacturer: Weiss Umwelttechnik GmbH
• Model: KWP-64/75
• Internal dimensions: approx. 500 x 400 x 325 mm
• Temperature: approx. -70° to +130° Celsius
• Refrigerant: R404A / R23
• Rated power: approx. 1.4 kW
• Year of manufacture: approx. 2004
• Condition: Used, fully functional
The cabinet can be inspected and tested at any time!
Shipping costs via freight forwarder: approx. €150
International buyers are welcome!
You will receive an invoice with VAT shown.
Inspection/collection is possible by arrangement in 42855 Remscheid.
Sale from location 42855 Remscheid, free on truck.
Errors in technical data and prior sale are reserved.
Listing
Germany
1,034 km
Chamber Furnace
NaberthermMobilotherm W 1000/H
Call
Condition: ready for operation (used), Year of construction: 1998, An electric Nabertherm shuttle kiln for firing ceramics, stoneware and soft-paste porcelain is offered. Connected load: 69kW, maximum temperature: 1340°C, volume: approx. 1000l, internal dimensions X/Y/Z: 800mm/1600mm/800mm, control system: Nabertherm C19 program controller. Equipped with automatic exhaust-air flap control, motorized ceiling flap and removable lifting eyes. Overall dimensions X/Y/Z: approx. 1300mm/2200mm/1840mm, weight: approx. 3000kg. Documentation available. An on-site inspection is possible.
Nedpszpa R Esfx Akcowi
Listing
Perriers-sur-Andelle
740 km
Fermentation chamber without floor CA 4
Panimatic1804776000
Call
Condition: new, External dimensions L x W x H: 1930 x 2080 x 2280 mm
Configuration with 2 independent cells, each containing 2 trolleys, for a total of 4 trolleys.
Additional dividers included for dividing into multiple cells.
Equipped with 2 solid, single-door doors.
2 integrated 720 x 150 mm wall evaporators.
2 refrigeration units supplied, type CAJ 9513 or UN 9232, using R452A refrigerant.
External height without floor: 2115 mm
Doorway height: 1800 mm
Dimensions suitable for 600x800 mm trays
Compatible trolley dimensions: 700 x 890 x 1870 mm
2 independent cells with autonomous cycle management
Capacity: 2 trolleys per cell (4 trolleys in total)
Temperature range: -10°C to +35°C
Modular structure without floor (installation on a perfectly level floor)
Insulating panels, 60 mm thick, with high thermal performance
Interior finish: food-grade aluminum
Exterior finish: reinforced aluminum
2 wall evaporators, 720 x 150 mm
Heating power: 2200 W
Heater resistance: 80%
2 independent refrigeration units
Position of units: low
Environmentally friendly refrigerant: R452A
Professional electronic control: Control Panel 2008 V2
Control panel type: cabinet
Electrical supply: 220 V Single-phase – 16 A – 50 Hz
2 solid doors, 895 x 1360 mm
Opening: 1 door per door
Water drain: external diameter 32 mm
Water inlet: 1/4 inch connection (above the chamber)
Nwodpfx Aszk Hk Iskcoi
Remote installation possible
Delivered disassembled for easy access.
Listing
Voerde (Niederrhein)
791 km
Chamber filter-press
Kammerfilterpresse Andritz 1500/2000/125Andritz/Netzsch 1500x2000
Call
Condition: used, Used chamber filter press Andritz/Netzsch 1500x2000 with 125 plates
Quantity: 2 available
Press dimensions: Length: 13455 mm x Width: 3125 mm x Height: 4635 mm
Nwedjzlb D Sopfx Akcoi
Empty weight: 51600 kg
Filter area: 459 m2
Filter area after expansion: 559 m2
Press volume: 4989 l
Press volume after expansion: 6080 l
Cake thickness: 25 mm
Listing
Ennepetal
847 km
Cold chamber die casting machine
ItalpresseIP 200 SC
Call
Condition: used, Year of construction: 1997, functionality: fully functional, clearance between the columns: 480 mm, total height: 2,040 mm, total width: 1,750 mm, stroke length: 460 mm, total length: 5,177 mm, column diameter: 90 mm, type of input current: three-phase, input voltage: 400 V, overall weight: 9,500 kg, clamping force: 2,000 kN, power: 18 kW (24.47 HP), input frequency: 50 Hz, Equipment: documentation/manual, We are offering this used Italpresse IP 200 SC die-casting machine, manufactured in 1997.
Type: IP 200 SC
Manufacturing number: 2449
Year of manufacture: 11.1997
Wiring diagram no.: 147081052
Operating voltage: 400 V
Mains frequency: 50 Hz
Auxiliary power supply: 110VAC–24VDC
Control voltage inputs: 24 VDC
Control voltage outputs: 24 VDC
Power consumption: 18 kW
Installed power: 23 kW
Enclosure protection class: IP55
Hydraulic pump: Vickers 4525V42A17 – 86DD 22R
Pressure accumulator TÜV certificate: Last inspection in 2018, next inspection due on 01.08.2028.
In recent years, extensive investments have been made in the technology to ensure reliability:
2024: Installation of a new column including nut.
2023: Replacement of various wear parts (column wiper, slide rails/slide shoes including wiper) as well as complete seal kits for the closing cylinder and multiplier.
Nwsdpfxozlw N Re Akcei
2021: Installation of new pump inserts for high and low pressure.
The machine will be sold including a Gauss VS1 dosing unit with a separate, compact control panel and a gas-operated melting furnace with a 200-liter crucible and a Hindenlang gas burner (type HO-3).
Original manual and complete electrical and pneumatic diagrams are available.
The machine is currently still in active production. Since it is in operation, the operating hours cannot be read exactly, but an inspection under power is possible at any time by arrangement.
The machine will be disconnected at the end of September / beginning of October.
If you have any questions or require further information, please send us a message or call us.
Listing
Borken
785 km
DIN 50017 corrosion test chamber
H. Köhler Kesternich-PrüfgerätHK 300 S 300 Liter
Call
Condition: good (used), H. Köhler HK 300 S Condensation Water Test Device
Manufacturer: H. Köhler GmbH
Type: HK 300 S
Machine Type: Condensation Water Test Device / Corrosion Test Chamber
Test Chamber Volume: approx. 300 l
For sale is a used H. Köhler HK 300 S condensation water test device.
The device is suitable for condensation water climate tests according to DIN 50 017, corrosion tests,
coating tests, paint tests, material testing, and quality assurance.
Technical Data
Test chamber volume: approx. 300 l
Temperature range: Room temperature to approx. +55 °C
Humidity range: Saturation operation possible
Test chamber heating: 1,000 W
Power connection: 230 V / 50 Hz
Connected load: 1,000 W
Compressed air consumption during ventilation: approx. 3 Nm³/h
Compressed air connection: 4.5 - 7.0 bar
Deionized water connection: 2.5 - 4.0 bar
Dimensions (W x D x H): approx. 1,200 x 600 x 1,750 mm
Weight: approx. 100 kg
Control
HK PC102 control unit
LCD display
Programmable test sequences
Condensation water climate DIN 50 017
Manual operation / test operation
Alarm display
Equipment
Stainless steel test chamber
Large glass door with seal
Test chamber thermometer
Manometer
Ventilation system
Compressed air connection
Deionized water connection
Drain connection
Stainless steel base with rollers
Accessories as shown in the pictures
Condition
Used
Optical condition as shown in the pictures.
Display shows condensation water climate DIN 50 017.
No documentation available.
Scope of supply
H. Köhler HK 300 S Condensation Water Test Device
Stainless steel base
Accessories as shown in the pictures
Nwjdpfx Akszhadcecsi
Scope of supply as shown in the pictures.
Subject to changes, errors and prior sale.
Listing
Borken
785 km
SO₂ test chamber | DIN 50017 | 300 liters
H. Köhler Kesternich-PrüfgerätHK 300 S
Call
Condition: good (used), H. Köhler HK 300 S Kesternich Corrosion Testing Unit
Manufacturer: H. Köhler GmbH
Type: HK 300 S
Year of manufacture: unknown
Machine type: Kesternich corrosion testing unit / SO₂ corrosion testing chamber
Test chamber volume: approx. 300 l
For sale is a used H. Köhler HK 300 S corrosion testing unit for performing Kesternich or SO₂ corrosion tests according to DIN 50017 / DIN EN ISO 6988.
The unit is suitable for corrosion testing of metals, coatings, paints, and components in the laboratory, research, development, and quality assurance.
Technical data
Test chamber volume: approx. 300 l
Temperature range: ambient temperature to approx. +55 °C
Humidity operation: saturation operation possible
Test chamber heating: 1,000 W
Connected load: approx. 1,100 W
Power connection: 230 V / 50 Hz
Compressed air consumption: approx. 3 Nm³/h
Compressed air connection: 4.5 – 7.0 bar
Demineralized water connection: 2.5 – 4.0 bar
Spray pressure: 0.7 – 1.5 bar
Dimensions (W × D × H): approx. 1,200 × 600 × 1,750 mm
Weight: approx. 100 kg
Control
HK PC102 microprocessor control
LCD display
Programmable test sequences
Temperature control
Equipment
Stainless steel test chamber
Large viewing window
Gas metering device
Ventilation system
Temperature control
Test chamber thermometer
Manometer
Compressed air connection
Demineralized water connection
Exhaust connection
Operating manual available
Maintenance documents available
EC declaration of conformity available
Application areas
Kesternich test
SO₂ corrosion test
Corrosion test
Coating test
Paint test
Material test
Automotive industry
Quality assurance
Research and development
Condition
Used
Optical condition as shown in the pictures.
Scope of delivery
Nwjdpfx Aezg U Tiskcei
H. Köhler HK 300 S corrosion testing unit
Operating manual
EC declaration of conformity
Maintenance documents
Documentation
Accessories as shown in the pictures
Scope of delivery as shown in the pictures.
Subject to changes, errors and prior sale.
Listing
Borken
785 km
Temperature test chamber
CTSTS -70/600-13
Call
Condition: used, CTS
Nwedpezg Tzfsfx Akcoi
Type: TS-70/600-13
Water-cooled temperature test chamber
Type series: TS-70/600-13
Control:
- 32-bit controller
- LCD control panel
- Digital display of setpoint and actual values
- Numerical input of setpoints
- Error messages in plain text
- RS 232 interface
- Free switching channels for customer-specific test specimen control
Test chamber volume: 600 liters
Test chamber dimensions: Height approx. 730 mm, width approx. 850 mm, depth approx. 830 mm
External dimensions: Height approx. 2250 mm, width approx. 1300 mm, depth approx. 2475 mm
Temperature range: -70 to +180°C
Heating rate: 13 K/min from -40°C to +120°C
Cooling rate: 13 K/min from 120°C to -40°C
Temperature deviation: ± 0.1 K over time, ± 0.5 K spatially
Electrical connection: 400/3P/N/PE
Rated power: approx. 27.8 kW
Rated current: approx. 44.1 A
Compressor: 4TC-8.2Y/4PC-10.2Y
Refrigerant: R-404 A / R-23
Weight: 1350 kg
For your security as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
785 km
Temperature test chamber 1000 liters
CTST-55/1000 Li -50°C bis 100°C
Call
Condition: excellent (used), CTS
Temperature testing chamber T-55/1000 Li, water-cooled
Temperature range: -50°C to +100°C
Rated voltage: 400V 3/N 50Hz
Rated power: 9.5 kW
Rated current: 18 A
Compressor: TFH2511Z / TFH2511Z, refrigerant R404A/R23
The type designation of the CTS chamber series is as follows:
e.g., Type T -55/1000/Li
1) T means: Temperature
2) -55 means: lower temperature -55°C
3) 1000 means: 1000-liter test chamber volume
4) Li means: special equipment for
testing with lithium-ion batteries
Control:
32-bit controller
LCD control panel
Digital display of setpoint and actual values
Numerical input of setpoints
Error messages in plain text
Ethernet interface
RS 232 interface
Free switching channels for customer-specific
control of the test item
Test chamber lighting:
energy-efficient, bright LED light strip mounted on the door
Insert rack:
Stainless steel, support surface 970 x 980 mm
Load per rack max. 35 kg
Total load with max. rack load 100 kg
Nwodpfx Akjzg Ty Ujcei
1a Conduit NW50
1b Conduit 2x NW125
1c Conduit 2x Rp 314°
for Minimax
Technical performance data:
Temperature tests:
Temperature range -50°C to +100°C
Temperature deviation ≤ ±0.3 K over time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 2.5 K/min
Thermal compensation
approx. 4000 W at +20°C
approx. 2200 W at -40°C
The technical data refer to an ambient temperature of +25°C,
rated voltage 400V, without test item, without thermal compensation and without additional equipment.
Options can affect the performance data.
Dimensions:
Test volume 1000 liters
Test chamber dimensions Height, approx. 1000 mm, Width, approx. 860 mm, Depth, approx. 1100 mm
External dimensions Height, approx. 1950 mm, Width, approx. 1270 mm, Depth, approx. 1900 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated current 18 A
Rated power 9.5 kW
Protection class IP 54
Sound pressure level < 58 dB(A)
(measured according to DIN EN ISO 3744
at a distance of 1 m from the front)
Weight approx. 1000 kg
Heat dissipation to the installation room 10.4 kW
Refrigeration unit:
water-cooled, low-noise, fully hermetic
stepless power adjustment by electronic monitoring and control system,
environmentally friendly refrigerant R404A/R23
For your safety as a buyer, the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerants
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data and information are subject to change!)
We will gladly answer any further questions you may have on the phone.
Listing
Borken
785 km
Temperature test chamber 600 liters
CTST-70/600/S -70°C bis 180°C
Call
Condition: excellent (used), CTS
Type: T-70/600/S
Water-cooled temperature testing cabinet
Control:
- 32-bit controller
- LCD control panel
- Digital display of setpoint and actual values
- Numerical input of setpoints
- Error messages in plain text
- RS 232 interface
- Free switching channels for customer-specific test specimen control
Technical performance data
Temperature tests:
Temperature range -70 °C to +180 °C
Temperature deviation ±0.1 to ±0.3 K over time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 2.5 K/min
Heat radiation
approx. 2500 W at +20 °C
approx. 2500 W at +0 °C
approx. 1800 W at -40 °C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400 V, without test specimen, without radiation, and without additional equipment.
Dimensions:
Nodpfx Akozg Ty Iocswi
Test volume 600 liters
Test chamber dimensions height, approx. 850 mm, width, approx. 850 mm, depth, approx. 830 mm
External dimensions height, approx. 1900 mm, width, approx. 1120 mm, depth, approx. 1875 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 8.8 kW
Rated current 14.8 A
Protection class IP 22
Weight approx. 700 kg
Refrigerant: R404A / R23
Weight: 600 kg
For your safety as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leakage test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Listing
Borken
785 km
Temperature test chamber 335 liters
Vötsch-70°C bis +180°C VTS 7034-5
Call
Condition: excellent (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch Temperature Test Chamber, Water-Cooled
Temperature range: -70°C to +180°C
Temperature deviation (temporal): ±0.1 to ±0.5 K
Temperature deviation (spatial): ±0.5 to ±2.0 K
Temperature change rate (cooling): 5.0 K/min
Temperature change rate (heating): 6.5 K/min
Heat compensation at +20°C: 3000 W
Heat compensation at -20°C: 3000 W
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Test chamber volume: 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50 Hz
Rated power: 10 kW, Rated current: 21 A
Sound pressure level at 1m distance (free-field measurement): < 69 dB (A)
Side feed-through: 5.5 cm / 12.5 cm
Chamber is water-cooled
Refrigerant: R-404A and R-23
Weight: approx. 570 kg
For your security as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Nedpszg Tyzsfx Akcswi
Listing
Borken
785 km
Temperature chamber -70 to +180°C
EspecEGN28-6CWL
Call
Condition: excellent (used), Espec
Type: EGN28-6CWL
Espec, water-cooled
Temperature test chamber, N series
Power supply:
AC 400 V, 3-phase, 50/60 Hz, 38 A
Temperature range: -70 to +180 °C
Temperature change rate:
Heating: 10 °K/min
Cooling: 5.5 °K/min
Internal dimensions (W x H x D) in mm: 1000 x 1000 x 800
Nwjdpfezg Tynox Akcji
External dimensions (W x H x D) in mm: 1205 x 1920 x 2159
Usable volume: 800 liters
Refrigerant: R-404A
Refrigerant: R-508A
Weight: approx. 695 kg
For your safety as a buyer, please note the following:
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will be subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data and information are subject to change!)
We will gladly answer any further questions you may have by phone.
We make it easier for you to find: "chamber pasteurizer"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month