Used Chamber Circulation Furnace for sale (3,907)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
785 km
Temperature test chamber 600 liters
CTST-40/600 -40...180°C
Call
Condition: excellent (used), CTS
Type: T-40/600 /011232
CTS Temperature Test Chamber, Water-Cooled
Including metal struts to increase the floor load capacity
Test chamber volume: 600 liters
Test chamber dimensions:
Height approx. 850 mm, width approx. 850 mm, depth approx. 830 mm
External dimensions:
Height approx. 1900 mm, width approx. 1050 mm, depth approx. 1850 mm
Temperature operating range:
Fgodpfszh Htwsx Ahpod
Temperature range: -40 to +180°C
Temperature deviation: ±0.1 to ±0.3 K over time
Heating rate: 2.5 K/min
Cooling rate: 3 K/min
Electrical connection: 400 V +6% -10%, 3/N, 50 Hz
Rated power: approx. 5.5 kW
Rated current: approx. 8.5 A
Refrigerant: R-404A
Weight: 550 kg
For your security as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by telephone.
Listing
Borken
785 km
Climatic chamber -75°C / +180°C with humidity control
TIRATCC 7120
Call
Condition: excellent (used), TIRA
Type: TCC 7120
Temperature range: -75°C / +180°C
Air-cooled condenser
Temperature stability (over time and in the center of the usable space): ±0.1°C ... ±0.3°C
Maximum temperature change rate:
Heating: 4°C/min
Cooling: 3°C/min
Humidity range: 10% to 98% relative humidity
Humidity stability over time: ±1% to ±3%
Dew point range during long-term tests: +2 / +94 °C
Dew point range during short-term tests: -20 / +2 °C
External dimensions (L x W x H): 1320 x 2235 x 2137 mm
Test chamber dimensions (L x W x H): 1000 x 1130 x 1020 mm
Test chamber volume: approx. 1152 liters
Max. load per shelf: 50 kg
Maximum floor load of the test chamber: 100 kg
Refrigerant: R404A and R23
Power supply: 400V + 6%/-10% / 50Hz / 3P+N+PE
Rated power: 10.2 max. 17.5 kW
Rated current: 19.5 max. 32.0 A
Fgedpfx Ahozh Htqepjd
Noise level: approx. 80 dB(A)
Weight: 1180 kg
For your security as a buyer, please note the following:
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will be subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and specifications are subject to change!)
We will gladly answer any further questions you may have by phone.
Listing
Borken
785 km
Thermal shock chamber, 200 liters
EspecTSA-202E-W -55°C bis 200°C
Call
Condition: excellent (used), Espec
Type: TSA-202E-W
Temperature shock chamber, water-cooled
Cold chamber: -55°C to 0°C
Hot chamber: +50°C to 200°C
System: Two-zone testing via damper control
Temperature fluctuation: ±0.5°C
Hot chamber:
Temperature: Heating time: from ambient temperature (20°C) to +200°C within 15 minutes.
Cold chamber:
Temperature: Cooling time: from ambient temperature (20°C) to -55°C within 35 minutes.
Temperature: Recovery time: within 5 minutes.
Internal dimensions (W x H x D mm): 650 x 460 x 670
External dimensions (W x H x D mm): 1550 x 1900 x 1670
Approx. 200 liters
Power supply: 400 V AC 50Hz: 65 A
Refrigerant: R404A 5 kg, R23 2.0 kg
Weight: approx. 1200 kg
Fgedozh Htkjpfx Ahpod
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by phone.

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing
Borken
785 km
Temperature test chamber spray device
VötschVBT 03/500 500 Liter -30 bis 80°C
Call
Condition: excellent (used), Vötsch
Type: VBT 03/500
Air-cooled
Temperature test chamber with spray device
Technical description:
Data for temperature tests without water:
Temperature range -30°C to +80°C
Fgsdpozh D S Rsfx Ahpod
Temperature deviation in the stabilized state
according to IEC 60068-3-5, depending on the test chamber temperature
± 1 K over time
Temperature change rate according to IEC 60068-3-5
Heating: approx. 2 K/min.
Cooling: approx. 2 K/min.
Data for temperature tests with water
Temperature range +5°C to +80°C
Possible water level -10 mm to 540 mm
Water level = -10 mm
The water level is below the support grid
Water level = 0 mm
The water level is at the top edge of the support grid
Data for spray device, standard
Number of spray nozzles 6
Spray volume per nozzle 0.5 l/min
Data for spray device according to EN 539-2, Method B
Number of spray nozzles 6
Spray volume per nozzle 4.5 l/min
Additional flooding nozzles 2
Spray volume additional nozzle 6 l/min
Compressed air consumption approx. 3 m³/h
Data for water tank with preheating
Volume approx. 2000 l
Temperature range for preheating +5°C to +40°C
Temperature change duration
Cooling from +18°C to +5°C approx. 15 h
Heating from +15°C to +40°C approx. 10 h
Data for installation and operation:
Test chamber: Width 1120 mm, Depth 840 mm, Height 540 mm
Housing: Width 2700 mm, Depth 1300 mm, Height 1575 mm
Water tank: Width 1100 mm, Depth 800 mm, Height 2200 mm
Feedthroughs
1 feedthrough ∅ 50 mm, installed on the left
Test chamber volume: approx. 500 liters
Refrigerant R-404a
Electrical connection:
Rated voltage 3/N/PE AC 400V ± 10% 50Hz
Rated power approx. 26 kW
Rated current approx. 44.0 A (neutral conductor loaded)
Fuse 63 A gG, on-site
Weight approx. 890 kg net
For your safety as a buyer, the following information!
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will be subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data and specifications are subject to change!)
We will gladly answer any further questions you may have over the phone.
Listing
Borken
785 km
Climate test chamber temp. -70 to 180°C
Weiss explosionsgeschütztWK-600/70 (I)-(II) 2 G EEx
Call
Condition: excellent (used), Weiss
Type: WK-600/70 (I)-(II) 2 G EEx /22605147
Weiss Climate Chamber, Water-Cooled
(Test chamber, explosion-proof)
Fjdpozh D Ryefx Ahpsgd
INERTIZATION WITH NITROGEN / EXPLOSION-PROOF TEST CHAMBER
Technical Data:
Test chamber designation: WK-600/70 (I)-(II) 2 G EEx
External dimensions with hinges and door lock:
Height 1995 mm, Width 1090 mm, Depth 1660 mm
External dimensions without hinges and door lock:
Height 1995 mm, Width 1000 mm, Depth 1660 mm
Test chamber volume: approx. 600 liters
Cold/Heat operation: -70 to 180°C
Climate operation: 10 – 95°C
Humidity: 10...98 % RH
Temperature change per unit of time:
Cooling: approx. 2.5 K/min
Heating: approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 14 kW
Rated current: 25 A
Fuse (on customer's side): 32 A, slow-blow
Permissible weight of test specimens:
Total load of the shelf supports: 80 kg
Test chamber floor: 80 kg, insert shelf: 40 kg
Weight: 800 kg
Refrigerant: R 404A/R 23
(Evaporator of the air conditioning system has been replaced)
For your safety as a buyer, please note the following information!
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by phone.
Listing
Borken
785 km
Climate chamber 138 liters
CLIMATSEXCAL 1413-HA -40 bis 180°C
Call
Condition: excellent (used), Climate chambers
Type: EXCAL 1413-HA
Air-cooled climate chamber
EXCAL is equipped with a 15-inch capacitive multi-touch panel PC, SSD storage, Windows 7, and 2 USB ports.
This makes it state-of-the-art.
Technical data:
Test chamber dimensions: Width 550 mm x Depth 500 mm x Height 500 mm
Housing dimensions: Width 820 mm x Depth 1375 mm x Height 1730 mm
Window 350 x 380
Volume: 138 liters
Feedthrough installed as standard
R1: 80 mm ∅
L1: 80 mm ∅
Data for temperature tests:
Temperature range: -40°C to +180°C
Temperature deviation over time ± 0.1 to ± 0.3 K
Temperature homogeneity spatially ± 0.5 to ± 1.8 K
Temperature change rate
Heating: 15 K/min
Cooling: 10 K/min
Data for climate tests:
Temperature range +10 to +90 °C
Humidity range 10 to 98 % RH
Fsdpszh D Rtefx Ahpogd
Data for operation:
3/N/Ph+T 400V ±10% 50 Hz
Rated power 9.8 kVA
Refrigerant R-404A / R-23
Weight: 430 kg
For your peace of mind as a buyer, please note the following:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and information are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Listing
Borken
785 km
Spray and splash water test chamber
WeissSWT 200/400
Call
Condition: excellent (used), Weiss
Type: SWT 200/400
Weiss spray and splash water test cabinet
This cabinet is used to test the ingress of water into enclosures.
Fodpozh D Rmsfx Ahpjgd
In conjunction with a timer, the test cycle can be automated with an adjustable test time from 3 seconds to 30 hours.
Complies with DIN VDE 0470 T1 or EN 60529 for tests according to protection classes IPX3 and IPX4.
The integrated circulation system can reduce water consumption to a minimum.
Features
Glass door with wiper
Pneumatic drive of the swivel nozzle
Adjustable swivel angle
Replaceable swivel nozzles
Nozzle holder swivels and is replaceable
Adjustable water flow rate and measurement
Control of the test duration
Data for mechanical stress
Max. load with test specimen (evenly distributed over the area)
Permissible test specimen weight for the test specimen holder (total) 25 kg
Spray radius 200 mm / 400 mm
Data for IP protection class tests
Swivel speed approx. 60°/s
Swivel angle IPX3 approx. ± 60°
Swivel angle IPX4 approx. ± 180° -10°
Dimensions:
External dimensions with control cabinet (D x W x H) approx. 1000 x 1350 x 1,900 mm
External (D x W x H) approx. 1000 x 1000 x 1,900 mm
Internal dimensions (D x W x H) 400 x 650 x 750 mm
Operating data
Voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power 1.5 kW
Rated current 6.0 A
Weight: 375 kg
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We would be happy to answer any further questions you may have by telephone.
Listing
Borken
785 km
Temperature shock test chamber
WeissTS 130
Call
Condition: used, Weiss
Type: TS 130
Temperature shock test chamber, water-cooled
Specification:
Temperature range, hot chamber: +60°C … +220°C
Temperature range, cold chamber: -10°C … -80°C
Hot/cold chamber changeover: 10 sec.
Temperature stability: ±1 K
Dimensions and other data:
External dimensions: Height 1990 mm
Width (without and with door hinge): without... approx. 1820 mm, with... approx. 1850 mm
Depth (without and with test chamber door): without... approx. 900 mm, with... approx. 1155 mm
Fgsdszh D N Ajpfx Ahped
Dimensions of the lifting platform (test chamber): Height 450 mm, Width 500 mm, Depth 600 mm
Volume: 130 liters
Test chamber load: max. 20 kg
Load on the test chamber floor: max. 20 kg
Cooling water pressure: min. 2 ... max. 6 bar
Max. fuse rating: 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of the unit: approx. 65 dB(A)
Refrigeration cascade, water-cooled
Connection values: 3/N/PE/AC 400V ±10% 50Hz / 14.0 kW
Rated current: 26.0 A
Refrigerant: R 404A / R23
Weight: approx. 950 kg
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by telephone.
Listing
Borken
785 km
Temperature test chamber 600 liters
CTST-70/600/S 70°C bis 180°C
Call
Condition: good (used), CTS
Type: T-70/600/S
Water-cooled temperature testing chamber
Refrigerant: Converted to R-452A
Control:
- 32-bit controller
- LCD control panel
- Digital display of setpoint and actual values
- Numerical input of setpoints
- Error messages in plain text
- RS 232 interface
- Free switching channels for on-site control of the test item
Technical performance data
Temperature tests:
Temperature range -70 °C to +180 °C
Fsdezh D E Rspfx Ahpjgd
Temperature deviation ±0.1 to ±0.3 K over time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 2.5 K/min
Heat radiation
approx. 2500 W at +20 °C
approx. 2500 W at +0 °C
approx. 1800 W at -40 °C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400 V, without test item, without radiation, and without additional equipment.
Dimensions:
Test volume 600 liters
Test chamber dimensions: height, approx. 850 mm, width, approx. 850 mm, depth, approx. 830 mm
External dimensions: height, approx. 1900 mm, width, approx. 1120 mm, depth, approx. 1875 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 8.8 kW
Rated current 14.8 A
Protection class IP 22
Weight approx. 700 kg
Refrigerant: R-452A / R23
Weight: 700 kg
For your security as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have on the phone.
Listing
Trittau
913 km
Washing Unit - Chamber
SUGINO ZIPPELZD-4.000-RAST
Call
Condition: used, Year of construction: 2015, Dimensions (L/W/H) ca. 4020 x 2460 x 2600 mm
total power requirement 78 kW
filling amount 1200 l
carrying capacity max. 0,5
bath temperature 65 °C
heating capacity 54 kW
In our opinion, the machine is in good used condition
and can be inspected under power by appointment.
Accessories, tools and clamping devices shown are only part of the scope of
delivery
if this is noted in the additional information.
Fgedpfx Ajzkbpxjhpod
Changes and errors in the technical data and information as well as
Subject to prior sale!
Listing
Duxford
436 km
Thermo Scientific CIR19 Circulating Bath
Thermo Fisher ScientificCIR19
Call
Condition: used, This listing is for Thermo Scientific CIR19 Circulating Bath
The unit is in full working condition and ready for immediate use.
Fgedpozgfxvsfx Ahped
This laboratory immersion circulator delivers exceptional temperature stability for sensitive samples. It features an intuitive digital controller, robust pumping capacity, and a durable stainless steel bath reservoir, making it perfect for routine clinical, industrial, or academic research application workflows.
Transparency Report and Technical Audit:
- Source Pedigree: Biotech / Research Facility
- Condition: Direct-from-Bench (Decontaminated/Original)
- Power-On Test: Verified; Digital display active, lighting operational, and fan system engaged.
- Integrity: 100% Original Parts (Non-Refurbished)
Software and Media Disclosure:
As a Direct-from-Lab asset, any original software media or accessories found with the unit are included as a courtesy.
Licensing Notice:
We do not provide, transfer, or guarantee software licenses or keys. The buyer is responsible for all software licensing, registration, and workstation compatibility via the manufacturer.
Notice for Procurement:
This unit is sold As-Is, Where-Is. While we verify the power-on status and physical integrity, we do not perform analytical validation, fluidic testing, or operational calibration. Ideal for labs with in-house technical expertise or existing service agreements.
Sustainability Impact:
By choosing Direct Reuse, your facility avoids the carbon footprint of new manufacturing and prevents specialized materials from entering waste streams. Direct-to-Lab reuse is the most carbon-efficient way to equip a modern laboratory
Listing
Wiefelstede
785 km
Chamber filter press
Poligrat470-20/2
Call
Condition: good (used), Year of construction: 1988, Reaction vessel, batch system, solids separator, washing trough, painter's wash station, water treatment, tool and water cleaning, filter press, chamber filter press
-Manufacturer: Poligrat, chamber filter press type 470-20/2
-Model: 11 plates
-Hydraulic cylinder: Stroke: 115 mm
-Dimensions: 1315/920/H1720 mm
Fodpfohvfznex Ahpogd
-Weight: 580 kg
Listing
Wiefelstede
785 km
Circulating pump measuring case
WiloMeß-Wilo
Call
Condition: good (used), Circulating pump measuring case
-Handover in its current condition as inspected
-various flanges and connections
-Circulation pump measuring Wilo
-Suitcase
Fgodpfx Asb A Rf Ujhpsd
-Weight: 19 kg
Listing
Wiefelstede
786 km
Circulation pump
SpeckVA25/43U EWN8/2-4
Call
Condition: used, Circulation pump, centrifugal pump, water pump, pump, heater
-Manufacturer: Speck, circulation pump type EWN8/2-4
Fedeh Hbxqjpfx Ahpjgd
-Engine: Type EWN8/2-4
-Dimensions: 180/130/H180 mm
-Weight: 3.6 kg
Listing
Borken
785 km
Thermal Shock Chamber 72 Liter
Espec TemperaturschockprüfschrankTSA-72EL-A -65°C bis +200°C
Call
Condition: excellent (used), ESPEC TSA-72EL-A Temperature Shock Chamber
Manufacturer: ESPEC Corporation
Type: TSA-72EL-A
Machine Type: Temperature Shock Chamber / Thermal Shock Chamber (2-Zone)
Design: Water-cooled
For sale is a used ESPEC temperature shock chamber, type TSA-72EL-A.
This unit is suitable for reproducible temperature cycling and thermal shock testing in
research, development, quality assurance, as well as for testing electronics, automotive components, aerospace parts, and materials.
The switchover between the hot and cold chambers is performed automatically via a 2-zone damper system.
Technical Data
Test chamber volume: approx. 70 liters
Internal dimensions (W x H x D): 410 x 460 x 370 mm
External dimensions (W x H x D): 1,310 x 1,900 x 1,470 mm
Weight: approx. 900 kg
Temperature range, hot chamber: +50 °C to +200 °C
Temperature range, cold chamber: -65 °C to 0 °C
Temperature stability: ±0.5 °C
Preheating temperature: up to +205 °C
Precooling temperature: up to -75 °C
Heating time: ambient temperature to +200 °C within approx. 15 minutes
Cooling time: ambient temperature to -70 °C within approx. 40 minutes
Fedpfjzhkfqsx Ahpegd
Temperature recovery time: ≤ 5 minutes
Max. test load: 30 kg evenly distributed
Cable entry: Ø 50 mm
Compressed air supply: 0.4 to 0.7 MPa (4 to 7 bar)
Refrigeration system / Power supply
Refrigeration system: Mechanical cascade refrigeration system
Refrigerant, high-temperature side: R404A
Refrigerant, low-temperature side: R23
Condenser: Water-cooled
Mains connection: AC 380 / 400 / 415 V
3 phases / 50 Hz
Max. current draw: 45 A
Equipment
10.4" TFT color touchscreen
PID temperature control
Program memory (RAM/ROM)
Trend graph
Alarm history
RS-485 interface
Eco mode
Automatic defrost
Vertical sliding door
Stainless steel test chamber
2 stainless steel test inserts
Mechanical cascade refrigeration system
Electronic expansion valve
Sirocco circulation fan
Pneumatic damper switchover
Cable entry Ø 50 mm
Applications
Temperature shock testing
Temperature cycling testing
Electronics testing
Semiconductor testing
Automotive
Materials testing
Component testing
Quality assurance
Research and development
Condition
Used
Optical condition as shown in the pictures.
Scope of supply
ESPEC TSA-72EL-A Temperature Shock Chamber
2 stainless steel test inserts
Accessories as shown in the pictures
Scope of supply as pictured.
Subject to change, errors and prior sale.
Listing
Voerde (Niederrhein)
791 km
Chamber filter-press
PassavantMembranfilterpresse 1500/200/58
Call
Condition: used, Year of construction: 2007, Attachment: Used chamber filter press, membrane filter press
Type: Passavant
Year of manufacture: 2007
Application area: Sludge dewatering
Filter plate format: 1500x2000
Number of plates: approx. 58
Filter plates: PP
Filter cloths: available as an option, tailored to the medium
Filter area: approx. 286 m2
Press volume: approx. 4660 dm3
Filter pressure: approx. 15 bar
Total weight: 32,900 kg
Fedpfx Ahszk E S Rspjgd
Application: Sludge treatment, dewatering system. Filter presses are batch-operated pressure filters used for the solid-liquid separation of suspensions.
Purchase or rental: Rental or purchase. Inspection of the equipment can be arranged at our factory.
Listing
Voerde (Niederrhein)
791 km
Chamber filter-press
Kammerfilterpresse 1500/200Passavant
Call
Condition: used, Year of construction: 2007, Attachment: Chamber filter press, used
Type: Passavant
Year of manufacture: 2007
Application: Sludge dewatering
Filter plate format: 1500x2000
Number of plates: approx. 58
Filter plates: PP
Filter cloths: available as an option, tailored to the medium
Fgsdpezk E H Iofx Ahpod
Filter area: approx. 286 m2
Press volume: approx. 4660 dm3
Filter pressure: approx. 15 bar
Total weight: 32,900 kg
Application: Sludge treatment, dewatering system. Filter presses are pressure filters that operate in a batch process for the solid-liquid separation of suspensions.
Purchase or rental: Rental or purchase. Inspection of the equipment can be arranged at our facility.
Listing
Viersen
800 km
Freeze Thaw Chamber Freezer Chamber Thawing
Farrar Scientific4105
Call
Condition: new, functionality: fully functional, New device!! Special offer!!! New price: €160,000
Firing and thawing chamber for the pharmaceutical industry.
Application Pharmaceutical and Bioprocessing.
The Farrar Scientific Controlled Rate Chamber permits fast freeze/thaw from +40C to -80C, uniform bulk freezing and/or thawing of Phase-Change Material (PCM) or products contained in a variety of containers (bags, bottles or any size containers) such as single use system (SUS), polycarbonate vessels or polypropylene vessels.
Temperature Range Programmable +40 ̊C to –80 ̊C
Fgsdpfxjv Rnl De Ahpod
Gbs7obps
Chamber Volume 659.8 L (23.3 Cu. Ft.)
Interior Dimensions (W x D x H) 34” x 27.5” x 43”
863.6 x 698.5 x 1092.2mm
Exterior Dimensions (W x D x H) 75” x 38” x 80”
1901.5 x 960.4 x 2028.8mm
Pull Down Empty Chamber < 38 minutes from +25 ̊C to –80 ̊C
Door Open Recovery at –80 ̊C < 10 minutes
100L Load +25 ̊C to –80 ̊C < 12 Hours
Unit comes with the complete documentation. Also the factory report.
The unit is unused and in its original packaging.
Shipping worldwide in a wooden box.
(#7709)
No further warranty or guarantee.
Listing
Borken
785 km
DIN 50017 corrosion test chamber
H. Köhler Kesternich-PrüfgerätHK 300 S 300 Liter
Call
Condition: good (used), H. Köhler HK 300 S Condensation Water Test Device
Manufacturer: H. Köhler GmbH
Type: HK 300 S
Machine Type: Condensation Water Test Device / Corrosion Test Chamber
Test Chamber Volume: approx. 300 l
For sale is a used H. Köhler HK 300 S condensation water test device.
The device is suitable for condensation water climate tests according to DIN 50 017, corrosion tests,
coating tests, paint tests, material testing, and quality assurance.
Technical Data
Test chamber volume: approx. 300 l
Temperature range: Room temperature to approx. +55 °C
Humidity range: Saturation operation possible
Test chamber heating: 1,000 W
Power connection: 230 V / 50 Hz
Connected load: 1,000 W
Compressed air consumption during ventilation: approx. 3 Nm³/h
Compressed air connection: 4.5 - 7.0 bar
Deionized water connection: 2.5 - 4.0 bar
Dimensions (W x D x H): approx. 1,200 x 600 x 1,750 mm
Weight: approx. 100 kg
Fgjdezhadcjpfx Ahpjd
Control
HK PC102 control unit
LCD display
Programmable test sequences
Condensation water climate DIN 50 017
Manual operation / test operation
Alarm display
Equipment
Stainless steel test chamber
Large glass door with seal
Test chamber thermometer
Manometer
Ventilation system
Compressed air connection
Deionized water connection
Drain connection
Stainless steel base with rollers
Accessories as shown in the pictures
Condition
Used
Optical condition as shown in the pictures.
Display shows condensation water climate DIN 50 017.
No documentation available.
Scope of supply
H. Köhler HK 300 S Condensation Water Test Device
Stainless steel base
Accessories as shown in the pictures
Scope of supply as shown in the pictures.
Subject to changes, errors and prior sale.
Listing
Borken
785 km
SO₂ test chamber | DIN 50017 | 300 liters
H. Köhler Kesternich-PrüfgerätHK 300 S
Call
Condition: good (used), H. Köhler HK 300 S Kesternich Corrosion Testing Unit
Manufacturer: H. Köhler GmbH
Type: HK 300 S
Year of manufacture: unknown
Machine type: Kesternich corrosion testing unit / SO₂ corrosion testing chamber
Test chamber volume: approx. 300 l
For sale is a used H. Köhler HK 300 S corrosion testing unit for performing Kesternich or SO₂ corrosion tests according to DIN 50017 / DIN EN ISO 6988.
The unit is suitable for corrosion testing of metals, coatings, paints, and components in the laboratory, research, development, and quality assurance.
Technical data
Test chamber volume: approx. 300 l
Temperature range: ambient temperature to approx. +55 °C
Humidity operation: saturation operation possible
Test chamber heating: 1,000 W
Connected load: approx. 1,100 W
Power connection: 230 V / 50 Hz
Compressed air consumption: approx. 3 Nm³/h
Compressed air connection: 4.5 – 7.0 bar
Demineralized water connection: 2.5 – 4.0 bar
Spray pressure: 0.7 – 1.5 bar
Dimensions (W × D × H): approx. 1,200 × 600 × 1,750 mm
Weight: approx. 100 kg
Control
HK PC102 microprocessor control
LCD display
Programmable test sequences
Temperature control
Equipment
Stainless steel test chamber
Large viewing window
Gas metering device
Ventilation system
Temperature control
Test chamber thermometer
Manometer
Compressed air connection
Demineralized water connection
Exhaust connection
Operating manual available
Maintenance documents available
EC declaration of conformity available
Application areas
Kesternich test
SO₂ corrosion test
Corrosion test
Coating test
Paint test
Material test
Automotive industry
Quality assurance
Research and development
Condition
Used
Optical condition as shown in the pictures.
Scope of delivery
H. Köhler HK 300 S corrosion testing unit
Operating manual
EC declaration of conformity
Maintenance documents
Documentation
Accessories as shown in the pictures
Scope of delivery as shown in the pictures.
Fgsdozg U Tiopfx Ahpjd
Subject to changes, errors and prior sale.
Listing
Borken
785 km
Temperature test chamber
CTSTS -70/600-13
Call
Condition: used, CTS
Type: TS-70/600-13
Water-cooled temperature test chamber
Type series: TS-70/600-13
Control:
- 32-bit controller
- LCD control panel
- Digital display of setpoint and actual values
- Numerical input of setpoints
- Error messages in plain text
- RS 232 interface
- Free switching channels for customer-specific test specimen control
Test chamber volume: 600 liters
Test chamber dimensions: Height approx. 730 mm, width approx. 850 mm, depth approx. 830 mm
External dimensions: Height approx. 2250 mm, width approx. 1300 mm, depth approx. 2475 mm
Temperature range: -70 to +180°C
Heating rate: 13 K/min from -40°C to +120°C
Cooling rate: 13 K/min from 120°C to -40°C
Temperature deviation: ± 0.1 K over time, ± 0.5 K spatially
Electrical connection: 400/3P/N/PE
Rated power: approx. 27.8 kW
Fedpfx Aezg Tzfehpogd
Rated current: approx. 44.1 A
Compressor: 4TC-8.2Y/4PC-10.2Y
Refrigerant: R-404 A / R-23
Weight: 1350 kg
For your security as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
785 km
Temperature test chamber 1000 liters
CTST-55/1000 Li -50°C bis 100°C
Call
Condition: excellent (used), CTS
Temperature testing chamber T-55/1000 Li, water-cooled
Temperature range: -50°C to +100°C
Rated voltage: 400V 3/N 50Hz
Rated power: 9.5 kW
Rated current: 18 A
Compressor: TFH2511Z / TFH2511Z, refrigerant R404A/R23
The type designation of the CTS chamber series is as follows:
e.g., Type T -55/1000/Li
1) T means: Temperature
2) -55 means: lower temperature -55°C
3) 1000 means: 1000-liter test chamber volume
4) Li means: special equipment for
testing with lithium-ion batteries
Control:
32-bit controller
LCD control panel
Digital display of setpoint and actual values
Numerical input of setpoints
Error messages in plain text
Ethernet interface
RS 232 interface
Free switching channels for customer-specific
control of the test item
Test chamber lighting:
energy-efficient, bright LED light strip mounted on the door
Insert rack:
Stainless steel, support surface 970 x 980 mm
Load per rack max. 35 kg
Total load with max. rack load 100 kg
1a Conduit NW50
1b Conduit 2x NW125
1c Conduit 2x Rp 314°
for Minimax
Technical performance data:
Temperature tests:
Fgedpfx Ahozg Ty Ujpsd
Temperature range -50°C to +100°C
Temperature deviation ≤ ±0.3 K over time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 2.5 K/min
Thermal compensation
approx. 4000 W at +20°C
approx. 2200 W at -40°C
The technical data refer to an ambient temperature of +25°C,
rated voltage 400V, without test item, without thermal compensation and without additional equipment.
Options can affect the performance data.
Dimensions:
Test volume 1000 liters
Test chamber dimensions Height, approx. 1000 mm, Width, approx. 860 mm, Depth, approx. 1100 mm
External dimensions Height, approx. 1950 mm, Width, approx. 1270 mm, Depth, approx. 1900 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated current 18 A
Rated power 9.5 kW
Protection class IP 54
Sound pressure level < 58 dB(A)
(measured according to DIN EN ISO 3744
at a distance of 1 m from the front)
Weight approx. 1000 kg
Heat dissipation to the installation room 10.4 kW
Refrigeration unit:
water-cooled, low-noise, fully hermetic
stepless power adjustment by electronic monitoring and control system,
environmentally friendly refrigerant R404A/R23
For your safety as a buyer, the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerants
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data and information are subject to change!)
We will gladly answer any further questions you may have on the phone.
Listing
Borken
785 km
Temperature test chamber 600 liters
CTST-70/600/S -70°C bis 180°C
Call
Condition: excellent (used), CTS
Fgedpfxezg Ty Is Ahpsd
Type: T-70/600/S
Water-cooled temperature testing cabinet
Control:
- 32-bit controller
- LCD control panel
- Digital display of setpoint and actual values
- Numerical input of setpoints
- Error messages in plain text
- RS 232 interface
- Free switching channels for customer-specific test specimen control
Technical performance data
Temperature tests:
Temperature range -70 °C to +180 °C
Temperature deviation ±0.1 to ±0.3 K over time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 2.5 K/min
Heat radiation
approx. 2500 W at +20 °C
approx. 2500 W at +0 °C
approx. 1800 W at -40 °C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400 V, without test specimen, without radiation, and without additional equipment.
Dimensions:
Test volume 600 liters
Test chamber dimensions height, approx. 850 mm, width, approx. 850 mm, depth, approx. 830 mm
External dimensions height, approx. 1900 mm, width, approx. 1120 mm, depth, approx. 1875 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 8.8 kW
Rated current 14.8 A
Protection class IP 22
Weight approx. 700 kg
Refrigerant: R404A / R23
Weight: 600 kg
For your safety as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leakage test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Listing
Borken
785 km
Temperature test chamber 335 liters
Vötsch-70°C bis +180°C VTS 7034-5
Call
Condition: excellent (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch Temperature Test Chamber, Water-Cooled
Temperature range: -70°C to +180°C
Temperature deviation (temporal): ±0.1 to ±0.5 K
Temperature deviation (spatial): ±0.5 to ±2.0 K
Temperature change rate (cooling): 5.0 K/min
Temperature change rate (heating): 6.5 K/min
Heat compensation at +20°C: 3000 W
Heat compensation at -20°C: 3000 W
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Test chamber volume: 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50 Hz
Rated power: 10 kW, Rated current: 21 A
Sound pressure level at 1m distance (free-field measurement): < 69 dB (A)
Side feed-through: 5.5 cm / 12.5 cm
Chamber is water-cooled
Refrigerant: R-404A and R-23
Fedpozg Tyzefx Ahpegd
Weight: approx. 570 kg
For your security as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Listing
Borken
785 km
Temperature chamber -70 to +180°C
EspecEGN28-6CWL
Call
Condition: excellent (used), Espec
Type: EGN28-6CWL
Espec, water-cooled
Temperature test chamber, N series
Power supply:
Fgsdpfx Ahszg Tynjpod
AC 400 V, 3-phase, 50/60 Hz, 38 A
Temperature range: -70 to +180 °C
Temperature change rate:
Heating: 10 °K/min
Cooling: 5.5 °K/min
Internal dimensions (W x H x D) in mm: 1000 x 1000 x 800
External dimensions (W x H x D) in mm: 1205 x 1920 x 2159
Usable volume: 800 liters
Refrigerant: R-404A
Refrigerant: R-508A
Weight: approx. 695 kg
For your safety as a buyer, please note the following:
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will be subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data and information are subject to change!)
We will gladly answer any further questions you may have by phone.
We make it easier for you to find: "chamber circulation furnace"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month







































































































































































































































