Combined heat and power plantagriKomp GmbH
BGA/NGA168
Combined heat and power plant
agriKomp GmbH
BGA/NGA168
Year of construction
2024
Condition
New
Location
Merkendorf 

Show images
Show map
Machine data
- Machine type:
- Combined heat and power plant
- Manufacturer:
- agriKomp GmbH
- Model:
- BGA/NGA168
- Year of construction:
- 2024
- Condition:
- new
- Functionality:
- fully functional
Price & Location
- Location:
- Energiepark 2, 91732 Merkendorf, Deutschland

Call
Technical details
- Power:
- 350 kW (475.87 HP)
Details about the offer
- Listing ID:
- A16761621
- Update:
- 09.09.2024
Description
Compact, highly efficient combined heat and power unit with a state-of-the-art SCANIA V 8-cylinder, lean-burn gas turbo, 4-stroke gas Otto engine. Unit, gas pressure control system, mixture and engine water cooling circuit mounted on base frame for power and heat generation with a high-quality synchronous generator (3P, 400V, 50Hz) for mains/parallel operation and optimized heat extraction via plate heat exchanger for heating water/process heat with a temperature level of VL 85°C / RL 70°C,
OPTIONAL: with catalytic converter (optional SCR system) for low-emission operation in accordance with the MCP Directive (EU) and 44th BImSchV (DE).
TECHNICAL DATA
GENSET /CHP - Biogas 50% CH4
Electrical output at cos φ=1: 350 kWel
Electrical efficiency: 41.4 %
Thermal output motor at 180^exhaust gas temperature: 334 kWth
Electricity coefficient el/th. : 1,05
Engine type V8
Displacement: 16 Ltr
Combustion thermal output - 100% load: 845kWel
Cjdpfx Aot Uu Ezeh Hogn
Gas consumption at50%CH4: 169.1Nm³/h
Length x width x height m 4.1 x 1.5 x 2.1
Weight unfilled 4500kg
The CHP has a control cabinet with a display for the visualization of all relevant operating parameters including a DSL modem for remote maintenance and external monitoring, as well as an interface for control energy for connection to the Energiepilot E2M. The scope of delivery includes a mains starter to provide the optimum starting speed, as well as a gas detector, smoke detector, emergency stop switch and alarm flashing light/horn.
All pipes are made of V2A and insulated where necessary.
To ensure that the motors are kept warm, the installed heat pumps are programmed to start up in a set cycle,
that they start up in a set cycle and thus enable the desired temperature to be maintained.
An automatic gas shut-off valve for installation outside the CHP installation room is not included in the scope of delivery.
The CHP unit complies with the medium-voltage directive VDE-AR-N 4110:2018-11.
An automatic gas shut-off valve for installation outside the CHP installation room and all operating fluids are not included in the scope of delivery.
The CHP unit is also optionally available in a container.
The entire unit is also available as a natural gas version.
The listing was translated automatically. Translation errors are possible.
OPTIONAL: with catalytic converter (optional SCR system) for low-emission operation in accordance with the MCP Directive (EU) and 44th BImSchV (DE).
TECHNICAL DATA
GENSET /CHP - Biogas 50% CH4
Electrical output at cos φ=1: 350 kWel
Electrical efficiency: 41.4 %
Thermal output motor at 180^exhaust gas temperature: 334 kWth
Electricity coefficient el/th. : 1,05
Engine type V8
Displacement: 16 Ltr
Combustion thermal output - 100% load: 845kWel
Cjdpfx Aot Uu Ezeh Hogn
Gas consumption at50%CH4: 169.1Nm³/h
Length x width x height m 4.1 x 1.5 x 2.1
Weight unfilled 4500kg
The CHP has a control cabinet with a display for the visualization of all relevant operating parameters including a DSL modem for remote maintenance and external monitoring, as well as an interface for control energy for connection to the Energiepilot E2M. The scope of delivery includes a mains starter to provide the optimum starting speed, as well as a gas detector, smoke detector, emergency stop switch and alarm flashing light/horn.
All pipes are made of V2A and insulated where necessary.
To ensure that the motors are kept warm, the installed heat pumps are programmed to start up in a set cycle,
that they start up in a set cycle and thus enable the desired temperature to be maintained.
An automatic gas shut-off valve for installation outside the CHP installation room is not included in the scope of delivery.
The CHP unit complies with the medium-voltage directive VDE-AR-N 4110:2018-11.
An automatic gas shut-off valve for installation outside the CHP installation room and all operating fluids are not included in the scope of delivery.
The CHP unit is also optionally available in a container.
The entire unit is also available as a natural gas version.
The listing was translated automatically. Translation errors are possible.
Seller
Note: Register for free or log in, to access all information.
Registered since: 2021
Send inquiry
Telephone & Fax
+49 9826 ... show
These listings may also fit your interest.
Listing
Viersen
798 km
Combined heat and power plant
MWMETW 800 EG-CO-KA
MWMETW 800 EG-CO-KA
Listing
Ystad
1,087 km
Thermoformer
ILPRATMF SPEEDYFORM
ILPRATMF SPEEDYFORM
Listing
Rimini
1,698 km
Emergency power generator
ERCOLE MARELLI1312T
ERCOLE MARELLI1312T
Listing
Gusselby
1,207 km
Complete sawline for big logs
AKE,Söderhamns, Remill, Catech, Ari
AKE,Söderhamns, Remill, Catech, Ari
Listing
Urk
665 km
Thermoformer
WebomaticAPS ML 7100
WebomaticAPS ML 7100
Listing
Roreto
1,435 km
UNLOADER (SINGLE-CAGE)
RBO (BIESSE Group)Tornado SC 1300
RBO (BIESSE Group)Tornado SC 1300
Listing
Germany
1,137 km
Steam Turbine
Nadrowski BielefeldC4DS-GVI
Nadrowski BielefeldC4DS-GVI
Listing
Bergkamen
843 km
Mini excavator
CASECX 26 C mit Klima
CASECX 26 C mit Klima
Listing
Forst
1,069 km
100 m³ buffer tank, 3 bar, insulated
Listing
Königswinter
882 km
Combined heat and power plant
MTU12V4000
MTU12V4000
Your listing has been deleted successfully
An error has occurred














































































































































