Used Huda Drop Shock Test System for sale (41,093)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
777 km
Vibration testing system shaker
Brüel & Kjær4812 + 4801
Call
Condition: good (used), Brüel & Kjær Vibration Test System 4812 + 4801 Shaker
Technical Specifications – Exciter Head 4812
• Max. dynamic force: 445 N (100 lbf) with Body 4801
• Current consumption: 23 A RMS with cooling / 11.5 A without
• Resonance frequency: 7.2 kHz
• Travel: 12.7 mm continuous / 14 mm maximum
• Acceleration limit: 981 m/s²
• Bolt torque limit: 3.4 Nm
Hfsdpfjxlz Uwex Apnjg
• Dimensions: Ø 235 mm × 178 mm
• Weight: 8 kg
• Material: hard-anodized aluminum
Technical Specifications – Exciter Body 4801
• Power supply: 380 V ±10% or 440 V ±10%, 3-phase, 50 Hz
• Cooling: Air-cooled (integrated fan)
• Mounting height (without head): 370–405 mm
• Additional height due to head: +50 to +130 mm
• Weight: 75–80 kg
Description & Use:
Condition: Used (see pictures).
Note:
For detailed technical specifications and processing instructions, we strongly recommend consulting the original data sheets or contacting the manufacturer directly.
Financing through our bank is also possible.
komplett-konzept.leasingo.de
You can find more items – new and used – in our shop!
International shipping costs upon request!
Listing
Borken
777 km
Temperature shock test chamber
VötschVT 7030 S2
Call
Condition: good (used), Year of construction: 1998, Vötsch VT 7030 S2 Temperature Shock Test Chamber -80 °C to +220 °C
The Vötsch VT 7030 S2 Environmental Test Chamber is designed for laboratory applications that require testing of materials and components in a known environment. With its versatile capabilities and easy-to-use controls, this programmable unit can be used to simulate a variety of environmental conditions for scientific studies, product testing and process control.
Data for temperature tests in single chamber operation
Hot chamber:
Temperature shock test chamber Test chamber 300 l
Temperature range +50 °C to +220 °C
Temperature deviation in time in the center of the chamber ± 1 K
Temperature deviation in space ± 2 K
Temperature gradient (according to IEC 60068-3-5) 4 K
Rate of temperature change (according to IEC 60068-3-5, measured in supply air)
Heating 11 K/min
Cold chamber:
Temperature shock test chamber Test chamber 300 l
Temperature range -80 °C to +70 °C
Temperature deviation in time in the middle of the usable space ± 1 K
Temperature deviation in space 2 K
Temperature gradient (according to IEC 60068-3-5) 4 K
Rate of temperature change (according to IEC 60068-3-5, measured in supply air)
Heating 1.5 K/min
Cooling 4K/min
Technical data:
Temperature shock test chamber
Test chamber volume approx. 300 l
Voltage: 3/N/PE AC 400 V ± 10 % , 50 Hz
Rated power: 30 kW
Rated power: 50 A
Refrigerant: R-404a /R-23
Chiller: Water-cooled
Weight: approx. 940 kg
Year of construction. 1998
Test room dimensions: Width 770 mm x depth 650 mm x height 610 mm
Housing dimensions: Width 1200 mm x depth 1800 mm x height 2050 mm
TS 05
Financing through our bank is also possible.
Hsdpfxswbdv Ss Apnefg
komplett-konzept.leasingo.de
Further items - new and used - can be found in our store!
International shipping costs on request!
Listing
Borken
777 km
Temperature shock test chamber -70-220°C
VötschVT 7012 S2
Call
Year of construction: 2000, operating hours: 104,382 h, condition: excellent (used), Vötsch Shock Test Chamber VT 7012 S2
System for extreme temperature cycling
Temperature shock testing is used to test the resistance of components, devices, and other products to rapid changes in ambient temperature.
The test specimens are subjected to rapid temperature changes in air with alternating upper and lower temperature loads.
These cyclical stresses and the accelerated aging caused by temperature changes reveal weaknesses in the test specimen.
Vertical arrangement of the test chambers
Ball screw drive for safe guidance of the car
Cart load capacity 50 kg for VT3 7012 S2
All-around grilles in the car secure the test specimens
High air circulation rate, short temperature change times, and uniform temperature distribution in the test chamber
Hot chamber can be used as a temperature storage unit, cold chamber as a temperature exchange unit
Minimal energy consumption
No compressed air required
Manufacturer: Vötsch
Type: VT 7012 S2
Type: Temperature shock test chamber
Test chamber volume: 120 l
Nominal voltage: 400 V
Nominal power: 10 kW
Nominal current: 25 A
Refrigerant: R452A
Cooling unit: Water-cooled
Shock cooling (nitrogen cooling) via customer-supplied nitrogen
External dimensions
Width: 930 mm
Depth: 2115 mm
Height: 1970 mm
Test chamber dimensions
Width: 470 mm
Depth: 650 mm
Height: 410 mm
Protection class
Device: IP 42
Operating panel: IP 20
Control cabinet: IP 54
Temperature test parameters for single-chamber operation |
Test chamber dimensions
Width: 470 mm
Depth: 650 mm
Height: 410 mm
Protection class ...Temperatur Temperature range
Hot chamber: +50°C to +220°C
Cold chamber: -70°C to +70°C
Temperature deviation over time: ±2 K
in steady state
Temperature deviation over space: ±2 K
in steady state in the car
Heating rate, hot chamber: 11 K/min
Cooling rate, cold chamber: K/min
Heating rate, cold chamber: 2 K/min
Cooling rate, hot chamber: K/min
Observation window: 355 x 355 mm
Pipe opening: 67 mm
Year of manufacture: 2000
Operating hours: 104,382
Weight: 1000 kg
Hsdpfjx Exmtex Apnefg
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Further items – new and used – can be found in our shop! International shipping costs on request!

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing
Borken
785 km
Shock test chamber –80 °C to +220 °C
VötschVT 7012 S2
Call
Condition: excellent (used), Vötsch
Model: VT 7012 S2
Shock Test Chamber, Air-cooled
Two-chamber design
Hot Chamber:
The temperature range of the hot chamber extends from +50°C to +220°C
Temporal temperature deviation at the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate
Heating: 11 K/min
Cold Chamber:
The cold chamber temperature range is from -80°C to +70°C
Temporal temperature deviation at the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate
Heating: 2 K/min
Cooling: 3 K/min
Test chamber volume: 125 liters
Hot chamber temperature range: +50°C to +220°C
Cold chamber temperature range: -80°C to +70°C
Test chamber dimensions: Width 470 mm, Depth 650 mm, Height 410 mm
External dimensions: Width 930 mm, Depth 2115 mm, Height 1970+ mm
Port diameter: ∅ 67 mm
Voltage: 3/N/PE AC 400V +10% 50 Hz
Nominal power: 10 kW
Nominal current: 25 A
Refrigerants: R452-A / R23
Weight: 1,000 kg
Important information for your safety as a buyer!
The following points are performed on our offered chambers in advance:
Hsdpfxjwxc I Uo Apnjfg
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Specifications and technical details are subject to change and correction!)
For further questions, please feel free to contact us by phone.
Listing
Borken
785 km
Temperature shock test chamber
WEISSTS 130
Call
Condition: excellent (used), White temperature shock test chamber
Here we offer a temperature shock test chamber.
Weiss temperature shock test chamber air cooled
( Compressor was renewed ! )
Specification:
Temperature range hot chamber +60°C ... +220°C
Temperature range cold chamber -10°C ... -80°C
Change hot-/cold chamber 10 s
Temperature constancy ±1 K
Dimensions and further data:
External dimensions: Height 1990 mm
Width ( without and with swivel arm ) without....ca. 1820 mm with....ca. 1915 mm
Depth ( without and with test chamber door ) without....approx. 900 mm with....approx. 1155 mm
Dimensions of the lifting basket ( test chamber ) height 450 mm, width 500 mm, depth 600 mm
volume 130 liters
Test space load max. 20 kg
Test chamber floor load max. 20 kg
Cooling water pressure min. 2 ... max. 6 bar
Max. Backup fuse 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of unit approx. 65 dB(A)
Cooling cascade water cooled
Connected load: 3/N/PE/AC 400V ±10% 50Hz /14,0 kW
nominal current 26,0 A
Refrigerant R 404A / R23
Weight: approx. 950 kg
Hedpfjk E Htyex Apnofg
Type: TS 130
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
785 km
Vibration test system
RMSSW 1507 / TGA 1500
Call
Condition: excellent (used), RMS vibration exciter with power amplifier and cooling fan
Here we offer you a RMS vibration exciter with power amplifier.
Vibration exciter SW 1507
Max force 2158 N
max. speed 1,3 ms
Power amplifier TGA 1500
3 x 380V/ 50Hz/ 35A / 8 kVA
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in technical data, specifications are reserved!)
Hsdpfxegkafis Apnofg
Further questions we can answer on the phone for you.
Written order possible by email or fax
Listing
Borken
785 km
Shock test chamber
HeraeusHT 7012 S2
Call
Condition: excellent (used), Heraeus shock test chamber
Here we offer a shock test chamber.
Temperature shock test chamber water cooled
Two-chamber design
Warm chamber:
The temperature range of the warm chamber is from +50°C to +220°C.
Temperature deviation temporally in useful chamber center ± 1 K
Temperature deviation spatially ± 2 K
Temperature change rate
heating 11 K/min
cold chamber:
the cold chamber from -65°C to +70°C
Temperature deviation temporally in useful space center ± 1 K
temperature deviation spatially ± 2 K
Hfedpfx Apoikvlxensg
Temperature change rate
heating 2 K/min
cooling 3 K/min
Test chamber volume 125 liters
Temperature range hot chamber +50°C to +220°C
Temperature range cold chamber -80°C to +70°C
Test chamber dimensions width 470mm depth 650mm height 410mm
Outer dimensions width 930mm depth 2115mm height 1970+mm
Rated power 10 kW
Rated current 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerant R404A / R23
Weight: 1000 kg
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Type: HT 7012 S2
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
785 km
Leak test system measuring range ±20 mbar
dr. wiesnerIntegra DDV -1...1 bar
Call
Condition: used, dr. wiesner
Hfedpewqm Ddjfx Apnjg
Type: INTEGRA DDV -1...1 bar
Product description:
dr. wiesner Integra leak test system
The classic - for all common test procedures
The leak test system for industrial leak-tightness and flow tests
with fully graphical color display
up to three independent test circuits operable
255 test programs can be stored
automatic process optimization autoTune (option)
communication via flexibly exchangeable bus coupling modules
freely programmable fixture control
freely programmable special test procedures
The device is suitable for tests according to the relative and differential pressure method with overpressure.
Special versions: none
Technical data:
Electrical supply: 110 ... 230V~; 50 ... 60Hz (connection via power cable to plug XO)
pneumatic: clean and dry compressed air max. 7 bar (to connection P)
Test pressure range: 0 ... 1000 mbar, electronically regulated
Measuring ranges
Relative pressure: 0 ... 1000 mbar
Differential pressure: +20 mbar
Resolution: 0.1 Pa
Internal volume:
13 cm³ test circuit
15.0 cm³ reference circuit
Electrical interfaces: 3x serial RS232 (COM1; COM2; COM3)
1x digital I/O (X1)
pneumatic:
Connection test object (Test)
Connection reference circuit (Ref.)
Enclosure
Protection class: IP40
Dimensions: 450x185x380mm (WxHxD)
Weight approx. 15.5kg
Condition: used
(Changes and errors in the technical data, information reserved!)
We are happy to answer further questions by phone.
Listing
Borken
785 km
Vibration test system
RMSSW 6507 mit TGD 9000-000.00
Call
Condition: used, Technical specifications (manufacturer/model type – without guarantee):
Peak force: “according to manufacturer specifications” approx. ≈ 10 kN
Max. acceleration: “up to approx. 1,000 m/s²”
Max. speed: “typically in the range of approx. 1 m/s to a few m/s”
Hsdpfx Apsxtdl Isnefg
Components:
- Control cabinet TGA 022/3
- Vibration exciter SW 6507
- Power amplifier TG D 9000-000.00
- Blower
Condition: used
Scope of delivery: Vibration test system as shown
(Subject to change and error in technical data!)
For further questions, we are happy to answer your call.
Listing
Borken
785 km
Vibration testing systems
IMVi240 / SA3AM
Call
Condition: used, IMV
Type: i240 + SA3AM Power Amplifier + Fan
Hfodjw H N U Djpfx Apneg
Dimensions
Power Amplifier: SA3AM.i40 W x H x D 1234 x 997 x 720 mm
Vibration Exciter: i240 W x H x D 580 x 1950 x 850 mm
Technical Data:
Armature Mass: 20 kg
Armature Diameter: 290 mm
Armature Resonance: 2300 Hz
Permissible Eccentric Moment: 850 N·m
Frequency Range: 0-2600 Hz.
Maximum Force: 24 kN (sine and random)
48 kN (shock)
Maximum Acceleration: 1200 m/s² (sine)
840 m/s² (random)
2400 m/s² (shock)
Maximum Displacement: 100 mm p-p.
Maximum Load Capacity: 400 kg.
Ambient Conditions: Temperature 0-40 °C, Humidity 0-85 %RH.
Maximum Output Power: 30 kVA (SA3AM-i40)
+
Shaker Armature 290 mm
Usable up to 2000 Hz
Weight: 410 kg (SA3AM-i40)
Total weight approx. 2800 kg
Condition: used
Scope of delivery: (see picture)
(Specifications subject to change and error!)
For further questions, please contact us by phone.
Listing
Borken
785 km
Shock test chamber
VötschVT 7012 S3
Call
Condition: excellent (used), Vötsch shock test chamber
Here we offer you a Vötsch shock test chamber.
Water cooled
Temp. range -80C to +220C
Hot chamber +50 to +220
Medium chamber -10 to +90
Hodpfx Apen Avcuenofg
Cold chamber -80 to +70
Mains voltage 400V +-10% 3/N 50Hz
Rated current 30.5 A
Rated power 13.5 KW
Refrigerant VK : R 404A 3.00kg p*: 25bar
Refrigerant TK : R23 15bar p* : 25 bar
Condition: used / used
Type: VT 7012 S3
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
785 km
Temperature shock test chamber
Weiss130 Liter TS 130 *
Call
Condition: excellent (used), Here we offer a temperature shock test cabinet.
White Temperature Shock Test Cabinet Air Cooled
Specification:
Temperature range hot chamber +60°C ... +220°C
Temperature range cold chamber -10°C ... -80°C
Change hot/cold chamber 10 s
Temperature constancy ±1 K
Dimensions and other data:
External dimensions: Height 1990 mm
Width ( without and with door hinge ) without....approx. 1820 mm with....approx. 1850 mm
Depth ( without and with test room door ) without....ca. 900 mm with....ca. 1155 mm
Dimensions of the lifting basket ( test chamber ) height 450 mm, width 500 mm, depth 600 mm
volume 130 liters
Test space load max. 20 kg
Test chamber floor load max. 20 kg
Cooling water pressure min. 2 ... max. 6 bar
Max. Backup fuse 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of unit approx. 65 dB(A)
Cooling cascade water cooled
Connected load: 3/N/PE/AC 400V ±10% 50Hz /14,0 kW
nominal current 26,0 A
Hodpfx Ajlgux Ajpnefg
Refrigerant R 404A / R23
Weight: approx. 950 kg
Type: TS 130
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
785 km
Battery test system with climate chamber
Keysight / Scienlab / AngelantoniBatterie-Testsystem SL1001A
Call
Condition: used, Keysight / Scienlab Battery Test System SL1001A + Angelantoni Climate Chamber DM500 C 10 ESS SPEEDY BT SP
Complete Battery Testing System – For Laboratory Use
Incl. PC, software & technical documentation
For sale is a professional battery test system, consisting of:
- Keysight / Scienlab SL1001A Battery Test System
- Angelantoni DM500 C 10 ESS SPEEDY BT SP Climate Chamber
- Monitoring/Sampling Unit
- Control PC with original software
- Technical documentation
The system is fully functional, well-maintained, and ideally suited for battery module testing, research, development, and quality assurance.
Technical Data – Scienlab SL1001A:
- Manufacturer: Keysight / Scienlab
- Model: SL1001A
- Year of manufacture: 2020
- Voltage / Current / Power: 80 V / 600 A / 24 kW
- Dimensions (L×W×H): approx. 1.6 × 0.9 × 3.3 m
- Weight: approx. 700 kg
- Function: Charging, discharging, and cycling of battery modules
- Condition: Very well maintained, laboratory use only
Technical Data – Angelantoni DM500 C 10 ESS SPEEDY BT SP:
- Manufacturer: Angelantoni Industrie S.r.l., Italy
- Model: DM500 C 10 ESS SPEEDY BT SP
- Year of manufacture: 2019
- Weight: approx. 1,225 kg
- Temperature range: -70 °C ... +180 °C
- Humidity range: 10 ... 98 % rH
- Refrigerants: R449A + R23
- Pressure ranges (PS Hi/Lo): 28 bar / 8 bar
- Wi-Fi integrated
- CE certification present
- Internal dimensions (L×W×H): approx. 1.6 × 2.3 × 3.3 m
- Function: Temperature and humidity testing, ESS (Environmental Stress Screening)
- Power supply: 3PH + N + PE, 400 V ±10 %, 50 Hz, full load 54 A
Hedpfxjxuqk He Apnefg
- Max. power consumption: 32.5 kW
Monitoring / Sampling Unit:
- Dimensions: 0.6 × 0.5 × 0.2 m
- Measured variables: Cell voltages, current, temperature
- Interfaces: CAN, Ethernet
- Compatible with Scienlab / Keysight PathWave software
PC + Software + Documentation:
- Industrial PC with control and measurement software
- Enables automated test runs, logging, and data analysis
Overall Dimensions / Weight (approx.):
Component Dimensions (L×W×H) Weight
Scienlab SL1001A 1.6 × 0.9 × 3.3 m 700 kg
Angelantoni Chamber 1.6 × 2.3 × 3.3 m 1,225 kg
Monitoring / PC 0.6 × 0.5 × 0.2 m 50 kg
Total system L 3.2 m × W 2.5 m × H 3.3 m approx. 1,975 kg
Applications:
- Development, testing, and lifespan analysis of battery modules (e.g., Li-ion, LFP, NMC)
- Fast charging and cycle tests
- Environmental simulation for temperature and humidity
- Research, industrial, and university laboratories
Important Note:
"The table shown in the photos is not included in the sale."
Scope of Delivery:
- Scienlab SL1001A power unit
- Angelantoni DM500 C 10 ESS SPEEDY BT SP climate chamber
- Monitoring/Sampling unit
- Control PC with software
- Technical documentation and manuals
- Connection cables and accessories (as available)
Condition: used
Scope of delivery: (see image)
(Specifications and data are subject to change and error!)
For any further questions, we are happy to assist you by phone.
Listing
Borken
785 km
Electrodynamic vibration test system
RMSSW 6011 SWT 6211/ 1 u. TGE 10 - 1/7
Call
Condition: used, RMS Control and Measurement Technology – Vibration Test System with Accessories
For sale is a high-quality set from RMS Control and Measurement Technology, including a Rietschle fan, ideal for vibration testing, resonance tests, and material examinations.
Included devices:
RMS CONTROL AND MEASUREMENT TECHNOLOGY – Vibration Exciter Type SW 6011 No. 2230
30 V – 200 A
13 mm / 1.2 m/sec / 100 g
Mounting Frame Type SWT 6211/1 No. 6074 – stable fixture for test specimens
Power Amplifier Type TGE 10‑1/7 – for optimal operation of the vibration exciter
Rietschle SKG 410‑2.01 Fan – high-performance vacuum/pressure blower
Condition: used
Hodpfx Asxudw Tepnsfg
Scope of delivery: (see picture)
(Specifications and technical details are subject to change and errors excepted!)
If you have further questions, we would be happy to clarify them by phone.
Listing
Borken
785 km
Shock test chamber
HeraeusHT 7012 S2
Call
Condition: excellent (used), Here we offer shock test chamber.
Temperature shock test chamber water cooled
Two-chamber design
Warm chamber:
Temperature control of the warm chamber ranges from +50°C to +220°C
Temperature deviation temporally in useful chamber center ± 1 K
Temperature deviation spatially ± 2 K
Temperature change rate
heating 11 K/min
cold chamber:
the cold chamber from -65°C to +70°C
Temperature deviation temporally in useful space center ± 1 K
temperature deviation spatially ± 2 K
Temperature change rate
heating 2 K/min
cooling 3 K/min
Test chamber volume 125 liters
Temperature range hot chamber +50°C to +220°C
Temperature range cold chamber -80°C to +70°C
Test chamber dimensions width 470mm depth 650mm height 410mm
Outer dimensions width 930mm depth 2115mm height 1970+mm
Rated power 10 kW
Rated current 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerant R404A / R23
Operating hours: 27.903 hrs.
Weight: 1000 kg
For you as a buyer, the following information for your safety!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
Hodpfx Apsi Az Egenofg
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Type: HT 7012 S2
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
785 km
Temperature shock test chamber
EspecTSD-100
Call
Condition: good (used), Espec
Hfodpfjugl H Sox Apnsg
Type: TSD-100
100 liters of usable space for larger test specimens up to 30 kg.
Complies with all current international standards.
Water-cooled
Temperature range hot chamber: +60 °C to +200 °C
Temperature range cold chamber: 0 °C to -70 °C
Test chamber dimensions: 710 x 345 x 410 (W x H x D) in mm
External dimensions: 1100 x 1885 x 1965 (W x H x D) in mm
Water-cooled refrigeration unit
Program control via touch panel
Automatic defrosting
Overtemperature protection
Operating hours counter
Mobile version
2 stainless steel test baskets
Cable gland Ø 100 mm
Refrigerant: R404A 1kg R23
Power supply: 400V 3Ph 50Hz
Max. Current consumption: 32A
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
785 km
Temperature shock test chamber
EspecTSD-100 -70 °C bis +200 °C
Call
Condition: excellent (used), Here we offer a temperature shock test chamber.
with 100 liters of usable space for larger test specimens up to 30 kg.
Compliant with all current international standards.
Water cooled
Temperature range hot chamber: +60 °C to +200 °C
Temperature range cold chamber: -70 °C to 0 °C
Test chamber dimensions: 710 x 345 x 410 (W x H x D) in mm
External dimensions: 1100 x 1885 x 1965 (W x H x D) in mm
Water-cooled refrigeration unit
Program control via touch panel
Automatic defrost
Overtemperature protection
Operating hours counter
Mobile version
2 test material baskets made of stainless steel
Cable gland Ø 100 mm
Refrigerant: 3 kg R404A 1kg R23
Power supply: 400V 3Ph 50Hz
Max. Current consumption: 32A
Type: TSD-100
Condition: used / used
Scope of delivery: (see picture)
Hfjdpfsn Smtmsx Apneg
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
785 km
Temperature shock test chamber
WeissTS 130
Call
Condition: used, White
Type: TS 130
Temperature shock test chamber water-cooled
Specification:
Temperature range hot chamber +60°C … +220°C
Temperature range cold chamber -10°C … -80°C
Hfjdpfxevwckhj Apnog
Switch between hot and cold chambers 10 sec.
Temperature stability ±1 K
Dimensions and other data:
External dimensions: Height 1990 mm
Width (without and with door hinge) without....approx. 1820 mm with....approx. 1850 mm
Depth (without and with test chamber door) without....approx. 900 mm with....approx. 1155 mm
Dimensions of the lifting basket (test room) height 450 mm, width 500 mm, depth 600 mm
Volume 130 liters
Test room load max. 20 kg
Test room floor load max. 20 kg
Cooling water pressure min. 2 ... max. 6 bar
Max. fuse 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of the device approx. 65 dB(A)
Water-cooled cooling cascade
Connection values: 3/N/PE/AC 400V ±10% 50Hz /14.0 kW
Rated current 26.0 A
Refrigerant R 404A / R23
Weight: approx. 950 kg
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
More We will be happy to answer any questions you may have over the phone.
Listing
Borken
785 km
Temperature shock test chamber
WEISSTS 130
Call
Condition: excellent (used), White temperature shock test chamber
Here we offer a temperature shock test chamber.
Weiss Temperature Shock Test Cabinet Water Cooled
Specification:
Temperature range hot chamber +60°C ... +220°C
Temperature range cold chamber -10°C ... -80°C
Change hot/cold chamber 10 s
Temperature constancy ±1 K
Dimensions and other data:
External dimensions: Height 1990 mm
Width ( without and with door hinge ) without....approx. 1820 mm with....approx. 1850 mm
Depth ( without and with test room door ) without....ca. 900 mm with....ca. 1155 mm
Dimensions of the lifting basket ( test chamber ) height 450 mm, width 500 mm, depth 600 mm
volume 130 liters
Test space load max. 20 kg
Test chamber floor load max. 20 kg
Cooling water pressure min. 2 ... max. 6 bar
Max. Backup fuse 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of unit approx. 65 dB(A)
Cooling cascade water cooled
Connected load: 3/N/PE/AC 400V ±10% 50Hz /18.7 kW
nominal current 26,0 A
Refrigerant R 404A / R23
Hfsdpfx Aolmkn Tspnjg
Weight: approx. 950 kg
Type: TS 130
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
785 km
Temperature shock test chamber
WEISSTS 130
Call
Condition: excellent (used), White temperature shock test chamber
Here we offer a temperature shock test chamber.
Weiss Temperature Shock Test Cabinet Water Cooled
Specification:
Temperature range hot chamber +60°C ... +220°C
Temperature range cold chamber -10°C ... -80°C
Change hot/cold chamber 10 sec.
Temperature constancy ±1 K
Dimensions and further data:
External dimensions: Height 1990 mm
Width ( without and with door hinge ) without....approx. 1820 mm with....approx. 1850 mm
Depth ( without and with test room door ) without....ca. 900 mm with....ca. 1155 mm
Dimensions of the lifting basket ( test chamber ) height 450 mm, width 500 mm, depth 600 mm
volume 130 liters
Test space load max. 20 kg
Test chamber floor load max. 20 kg
Cooling water pressure min. 2 ... max. 6 bar
Max. Backup fuse 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of unit approx. 65 dB(A)
Cooling cascade water cooled
Connected load: 3/N/PE/AC 400V ±10% 50Hz /14,0 kW
nominal current 26,0 A
Refrigerant R 404A / R23
Weight: approx. 950 kg
Type: TS 130
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Hedpfx Aom Ak H Hspnjfg
Listing
Borken
785 km
Shock test chamber -80°C to +220°C
VötschVT 7012 S2
Call
Condition: excellent (used), Here we offer Vötsch shock test chamber.
Temperature shock test chamber water cooled
Two-chamber design
Warm chamber:
The temperature control of the warm chamber ranges from +50°C to +220°C
Temperature deviation in time in the center of the chamber ± 1 K
Temperature deviation spatially ± 2 K
Temperature change rate
heating 11 K/min
cold chamber:
the cold chamber from -80°C to +70°C
Temperature deviation temporally in useful space center ± 1 K
temperature deviation spatially ± 2 K
Temperature change rate
heating 2 K/min
cooling 3 K/min
Test chamber volume 125 liters
Temperature range hot chamber +50°C to +220°C
Temperature range cold chamber -80°C to +70°C
Hedpfx Apjigg Hnonefg
Test chamber dimensions width 470mm depth 650mm height 410mm
Outer dimensions width 930mm depth 2115mm height 1970+mm
Feedthrough ∅ 67mm
Rated power 10 kW
Rated current 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerant R404A / R23
Weight: 1000 kg
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Type: VT 7012 S2
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
785 km
Vibration test system
RMSSW 1507 / TGA 1500
Call
Condition: excellent (used), RMS vibration exciter with power amplifier and cooling fan
Here we offer you a RMS vibration exciter with power amplifier.
Vibration exciter SW 1507
Max force 2158 N
max. speed 1,3 ms
Power amplifier TGA 1500
3 x 380V/ 50Hz/ 35A / 8 kVA
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Written order possible by email or fax
Hfjdpfxjgkaibj Apnsg
Listing
Borken
785 km
Temperature shock test chamber 60 liters
WeissTS 60 -72…+220 °C
Call
Condition: excellent (used), Weiss Technik TS 60 Thermal Shock Test Chamber / 60 L, –71…+220 °C
Water-cooled
Item description:
For sale is a Weiss Technik TS 60 Thermal Shock Test Chamber.
The chamber is ideally suited for rapid temperature cycling tests (e.g., per IEC, MIL-STD, JEDEC) and has been well maintained.
Volume & internal dimensions:
Test volume: 60 liters
Internal basket/test room dimensions (W × D × H): approx. 380 × 430 × 370 mm
External dimensions (W × D × H): 895 × 1970 × 1895 mm
Temperature ranges & cycling:
Hot chamber: +50 °C to +220 °C
Cold chamber: –72 °C to +70 °C
Transfer time (basket between both zones): < 10 seconds
Heating rate / speed up to 17 °C/min
Cooling rate / speed up to 3.7 °C/min
In single mode (cold zone only), heating rate: approx. 3.2 °C/min
Hfjdpexr A R Tjfx Apneg
Temperature deviation & uniformity:
Temporal deviation (temperature control over time): ± 0.3 to ± 1.0 °C
Load / permissible weight & lifting system:
Basket/lifting system load capacity: 20 kg maximum load
Transfer basket secured by safety grilles on all sides
Additional features & equipment:
Noise level: approx. 58 dB(A) in operation
Control: Touchscreen, RS-232 / USB / Ethernet interfaces
Electrical connection:
3/N/PE AC 400 V ±10% 50 Hz
Rated power: approx. 8.5 kW
Rated current: approx. 25 A
On-site protection: 32 A
Refrigerants: R-404A / R-23
Weight: 800 kg
Important safety information for buyers!
The following steps are carried out on our offered chambers prior to sale:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Technical data subject to change and errors reserved!)
For further questions, feel free to contact us by phone.
Listing
Janville
878 km
Automatic tablet testing system
Kraemer ElektronikUTS 4.1
Call
Condition: used, Year of construction: 2000, Sold for parts, ADU card missing.
Automatic tablet testing system
- Laboratory measuring equipment
- Tablet tool
Enables testing of:
Hardness
Diameter
Thickness
Weight
Precision balance Sartorius WZ64S
Scale : 10 à 50 g
Unit : mg / 0,5 mg / 0,1 mg adjustable
Thickness
Drive: stepper motor.
Measuring principle: linear potentiometer.
Unit of measurement: mm or inch.
Tolerance: +/- 0.1 mm
Hardness
Drive: stepper motor.
Measurement: load cell (lmz)
Measurement principle: dynamometric gauge
Unit: N, Kp or Sc
Diameter
Drive: stepper motor.
Measuring principle: stepper motor.
Unit of measurement: mm or inch.
Scale: 3 - 18 mm / 3 - 30 mm (manual)
Tolerance: +/- 0.1 mm
Tension : 100 / 240 V, 50Hz / 60 Hz
The UTS is a universal, fully automated testing system developed for use in industry. This tool is the approved model of a series of test systems that have been tested over many years. It was developed in close collaboration with the pharmaceutical industry.
The UTS 4.1 can be used to test round, oval, square and oblong tablets, as well as many special shapes. For delicate oblong tablets, the proven oblong centring system (OZB) can be integrated.
All parts requiring cleaning can be removed quickly and easily without any tools.
The test system can be supplemented with various options, such as a distributor and/or sample collector with a different number of stations.
Hedsx Rz I Dspfx Apnsfg
Use the UTS as a laboratory tester or an online control device connected to a tablet press. Sampling can be triggered either in the production machine or using the TTS11 software.
Listing
Borken
785 km
Shock test chamber –75°C to +220°C
VötschVT 7012 S2
Call
Condition: excellent (used), Vötsch
Model: VT 7012 S2
Water-cooled
Two-chamber configuration
Hot chamber:
Temperature range of hot chamber: +50°C to +220°C
Temporal temperature deviation at the center of useful space: ±1 K
Spatial temperature deviation: ±2 K
Temperature change rate:
Heating: 11 K/min
Cold chamber:
Temperature range of cold chamber: -74.5°C to +70°C
Temporal temperature deviation at the center of useful space: ±1 K
Spatial temperature deviation: ±2 K
Temperature change rate:
Heating: 2 K/min
Cooling: 3 K/min
Test chamber volume: 125 liters
Temperature range hot chamber: +50°C to +220°C
Temperature range cold chamber: -80°C to +70°C
Test chamber dimensions: width 470 mm, depth 650 mm, height 410 mm
External dimensions: width 930 mm, depth 2115 mm, height 1970+ mm
Port diameter: 67 mm
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Rated power: 10 kW
Rated current: 25 A
Refrigerants: R-452A / R-23
Weight: 1000 kg
Important safety information for buyers:
The following actions are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Recharging with legally compliant refrigerant
3. Leak test with certificate
4. After a successful check, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Subject to changes and errors in technical data and specifications!)
Hedpfjx Hhfhsx Apnefg
We are happy to answer further questions by phone.
We make it easier for you to find: "huda drop shock test system"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now