Used Vötsch Vtr 7033/S for sale (68,162)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
785 km
Climate test chamber 335 liters with humidity
VötschVCS 7034-5 -70°C bis +180°C
Call
Condition: good (used), Type: VCS 7034-5
Climatic Test Chamber, Water-cooled
Vötsch VCS 7034-5
Test Volume: 335 liters
Specifications for Temperature Testing:
Temperature range: -70 to +180°C
Time-based temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4 K
Change rate:
Cooling: 6.7 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3000 W / at -20°C: 3000 W
Temperature calibration points: +23°C and +80°C
Codpfx Aeziyxijmhjha
Specifications for Climate Testing:
Temperature range: +10 to +95°C
Time-based temperature deviation: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Time-based humidity deviation: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climate calibration points: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10 kW
Rated current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerants: R452A / R-23
Important safety information for buyers:
The following procedures are carried out on our offered chambers prior to sale:
1. Functional inspection and replacement of necessary components
2. Recharging with legally compliant refrigerant, if required
3. Leak test with certificate
4. After successful testing, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Subject to technical modifications and errors. All information is non-binding!)
For further questions, please do not hesitate to contact us by phone.
Listing
Borken
785 km
Climate test chamber with humidity
VötschVC³ 0100 0°C bis + 90°C
Call
Condition: excellent (used), Vötsch
Type: VC³ 0100
Vötsch Climate Test Chamber, Air-Cooled
Internal Test Chamber Dimensions: Height 950 mm x Width 1100 mm x Depth 950 mm
Overall Device Dimensions: Height 2000 mm x Width 1300 mm x Depth 1916 mm
Test Chamber Volume: 990 litres
Temperature Testing:
Minimum Temperature: -0°C
Maximum Temperature: +90°C
Temperature Change Rate, Cooling: 0.2 K/min
Temperature Change Rate, Heating: 0.5 K/min
Temporal Temperature Deviation: ±0.1 to ±0.5 K
Spatial Temperature Uniformity: ±0.5 to ±1.0 K
Heat Compensation at +20 °C: 350 W
Climatic Testing:
Minimum Temperature: +10°C
Maximum Temperature: +90°C
Dew Point Temperature Range: +4°C to +89.5°C
Humidity Range: 10 to 98% r.h.
Temporal Humidity Deviation: ±1 to ±3% r.h.
Temporal Temperature Deviation: ±0.1 to ±0.3 K
Spatial Temperature Uniformity: ±0.5 to ±1.0 K
Voltage: 1/N/PE AC 230V ±10% 50Hz
Rated Power: 2.3 kW
Rated Current: 10 A
Csdpfx Amoziypuoheha
Refrigerant: R-404A
Weight: approx. 1400 kg
Important information for you as a buyer:
The following measures are carried out on our offered chambers prior to delivery:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certification
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Specifications and technical details are subject to change and error!)
For further questions, we are happy to assist you by phone.
Listing
Borken
785 km
Climate test chamber with humidity
VötschVC³ 4100 990 Liter -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Vötsch climatic test chamber.
Model: VC³ 4100, air-cooled
With a temperature change rate of 3 K/min
Test chamber internal dimensions: Height 950 mm x Width 1100 mm x Depth 950 mm
Overall unit dimensions: Height 2000 mm x Width 1300 mm x Depth 1916 mm
Chamber volume: 990 liters
Port openings: Ø 125 mm, Ø 50 mm
Temperature test specifications:
Temperature range: -42°C to +180°C
Temporal temperature deviation: ± 0.1 to ± 0.5 K
Spatial temperature uniformity: ± 0.5 to ± 1.5 K
Temperature change rate:
Heating: 4.0 K/min
Cooling: 3.0 K/min
Max. heat compensation at +20°C: 4500 watts
Climatic test specifications:
Temperature range: +10°C to +95°C
Dew point range: -3°C to +94°C
Humidity range: 10 to 98% r.h.
Temporal temperature deviation: ± 0.1 to ± 0.3 K
Chedpfx Aeziypnsmhja
Spatial temperature uniformity: ± 0.5 to ± 1.0 K
Temporal humidity deviation: ± 1% to ± 3% r.h.
Max. heat compensation: 500 W
Power supply: 3/N/PE AC 400V ±10% 50Hz
Rated power: 11.5 kW
Rated current: 22.0 A
Refrigerant: R-404A
Weight: approx. 840 kg
Type: VC³ 4100
For your security as a buyer, please note the following information!
The following points are checked and carried out on all our chambers prior to sale:
1. Functional inspection and replacement of necessary components
2. If needed, fresh filling with legally compliant refrigerant
3. Leak check with certificate
4. After a successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See photo)
(Subject to prior sale, changes and errors in technical data and specifications reserved!)
We are happy to answer any further questions by phone.
Listing
Borken
785 km
-50°C to +220°C, -80 to +70°C, 60 liters
VötschVT³ 7006 S2 Temperaturschockschrank
Call
Condition: excellent (used), Vötsch
Type: VT³ 7006 S2-M
Water-cooled
Technical Specifications:
Maximum specimen weight: 20 kg
Test chamber volume: 60 liters
Test chamber internal dimensions: Width 380 mm, Depth 430 mm, Height 370 mm
External dimensions: Width 875 mm, Depth 1970 mm, Height 1895 mm
Vertical arrangement of hot and cold chambers (chamber change via lift carriage)
Temperature range of hot chamber: +50 °C to +220 °C (calibration value +125 °C)
Temperature range of cold chamber: -80 °C to +70 °C (calibration value -40 °C)
Chsdjzima Hopfx Amhoa
Uniform temperature distribution in the test chamber (±0.5 K to ±2.0 K)
Temporal temperature deviation: ±0.3 K to ±1.0 K
80 mm duct for measurement/supply connections to the specimen
SIMCONTROL software for operation and status display
Voltage: 3/N/PE AC 400V±10% 50Hz
Rated power: 8.5 kW
Rated current: 25 A
Refrigerants: R-404A, R-23
Weight: approx. 800 kg
Important information for your safety as a buyer!
The following points are carried out on the chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant, if required
3. Leak test with certificate
4. Following successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Specifications and information subject to change or error!)
Should you have any further questions, we are happy to answer them by phone.
Listing
Borken
785 km
Temperature test chamber -70°C to +180°C
VötschVTS 7018-5 190 Liter
Call
Condition: excellent (used), Vötsch
Model: VTS 7018-5
Water-cooled Temperature Test Chamber
System retrofitted with R-452A
Temperature range: -70°C to +180°C
Temporal temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Chjdpjziixxjfx Amhoa
Temperature change rate cooling: 7.5 K/min
Temperature change rate heating: 7.5 K/min
Heat compensation at +20°C: 3000 W
Heat compensation at -20°C: 3000 W
Test chamber dimensions: Width 580 mm, Depth 450 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1280 mm, Height 1575 mm
Test chamber volume: 190 liters
Rated voltage: 3/N/PE AC, 400V ±10%, 50Hz
Rated power: 10.0 kW, Rated current: 21 A
Main fuse (on-site): 32 A slow-blow
Sound level at 1m distance (free-field measurement): < 69dB (A)
Side port: 50 mm / 125 mm
Chamber is water-cooled
Refrigerants: R-452A and R 23
Weight approx. 460 kg
For your safety as a buyer, the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If required, new charging with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (See picture)
(Technical data may be subject to change or error!)
If you have any further questions, we will be happy to answer them by phone.
Listing
Borken
785 km
With moisture 270 liters
VötschKlimaprüfschrank VCS³ 7027-10
Call
Condition: excellent (used), Vötsch
Type: VCS³ 7027-10
Vötsch Climate Test Chamber, Water-Cooled
With a temperature change rate of 10 K/min
Csdozh Huuopfx Amhsha
Data for temperature testing:
Temperature range: -72°C to +180°C
Temporal temperature deviation in the center of the usable space: ± 0.3 K to ± 0.5 K
Spatial temperature deviation: ± 0.5 K to ± 2.0 K
Temperature change rate:
Heating: 10 K/min
Cooling: 14.5 K/min
Data for climate testing:
Temperature range: +10°C to +95°C
(extended climate range: 2°C/95% relative humidity, regulated for max. 2 hours)
Temporal temperature deviation in the center of the usable space: ± 0.2 K to ± 0.3 K
Spatial temperature deviation: ± 0.5 K to ± 1.0 K
Temporal humidity deviation in the center of the usable space: ± 1% to ± 3% relative humidity
Humidity range: 10% to 98% relative humidity
(extended climate range: 2°C/95% relative humidity, regulated for max. 2 hours)
External dimensions: Width 780 x Depth 1895 x Height 1775 (mm)
Test chamber dimensions: Width 580 x Depth 615 x Height 750 (mm)
Test chamber volume: approx. 270 liters
Side opening: 50 mm
Side opening: 125 mm
Data for operation:
LED strip 24 V, 6.8 W / 2 x halogen bulb 24 V, 50 W
Nominal voltage: 3/N/PE AC 400 V ±10%, 50 Hz
Nominal power: 14 kW Nominal current: 26 A
Fuse, on customer’s side: 63 A, slow-blow
Refrigerant: R404A/R-23
Weight: approx. 835 kg
For your security as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See image)
(Changes and errors in the technical data and specifications are subject to change!)
We will gladly answer any further questions you may have over the phone.
Listing
Borken
785 km
Climate test chamber with humidity, 190 liters
VötschVC 7018 -70 bis 180°C
Call
Condition: excellent (used), Vötsch
Type: VC 7018
Vötsch Climatic Test Chamber VC 7018 Water-Cooled
Touch Panel Control Unit
On the touch panel control unit, all control and operating commands can be triggered by simply touching the function symbols.
Adjustable Feet
To compensate for uneven floors and ensure adequate ventilation of the machine section,
the test chamber is equipped with adjustable feet.
Ports
The test chamber is equipped with port holes on the right and left sides.
These allow measurement cables and test equipment to be routed into the test chamber.
Feedthrough included in standard equipment
R1: NW 125 mm
L1: NW 50 mm
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1280 mm x Height 1745 mm
Characteristics for temperature tests:
Temperature range: -70°C to +180°C
Temperature ±0.1 to ±0.5 K
Spatial ±0.5 to ±2.0 K
Temperature change rate according to IEC 60068-3-5
Heating: 4 K/min
Cooling: 2.3 K/min
Characteristics for climatic tests:
Temperature range: -10°C to +95°C
Humidity range: 10% to 98% r.h. F.
Temperature deviation over time in the center of the usable space ± 0.1 to ± 0.3 K
Temperature deviation over space ± 0.5 to ± 1.0 K
Temperature gradient 1 to 2 K
Humidity deviation over time in the center of the usable space ± 1 to ± 3 %RH
Electrical connection:
Nominal voltage: 3/N/PE AC 400V ±10 50Hz
Nominal power: 5.9 kW
Nominal current: 12.0 A
Chedpfxszh Huho Amhea
Connection cable: 3.5 m
Fuse protection: 16 A slow-blow, provided by the customer
Refrigerants: R-404A and R-23
Test chamber capacity: approx. 190 liters
Weight: approx. 460 kg net
For your safety, the following information is provided as a buyer!
The following steps are performed on our offered chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
785 km
Temperature test chamber spray device
VötschVBT 03/500 500 Liter -30 bis 80°C
Call
Condition: excellent (used), Vötsch
Type: VBT 03/500
Air-cooled
Temperature test chamber with spray device
Technical description:
Data for temperature tests without water:
Temperature range -30°C to +80°C
Temperature deviation in the stabilized state
according to IEC 60068-3-5, depending on the test chamber temperature
± 1 K over time
Temperature change rate according to IEC 60068-3-5
Heating: approx. 2 K/min.
Cooling: approx. 2 K/min.
Data for temperature tests with water
Temperature range +5°C to +80°C
Possible water level -10 mm to 540 mm
Water level = -10 mm
The water level is below the support grid
Water level = 0 mm
The water level is at the top edge of the support grid
Data for spray device, standard
Number of spray nozzles 6
Spray volume per nozzle 0.5 l/min
Data for spray device according to EN 539-2, Method B
Number of spray nozzles 6
Spray volume per nozzle 4.5 l/min
Additional flooding nozzles 2
Spray volume additional nozzle 6 l/min
Compressed air consumption approx. 3 m³/h
Data for water tank with preheating
Volume approx. 2000 l
Temperature range for preheating +5°C to +40°C
Temperature change duration
Cooling from +18°C to +5°C approx. 15 h
Heating from +15°C to +40°C approx. 10 h
Data for installation and operation:
Test chamber: Width 1120 mm, Depth 840 mm, Height 540 mm
Housing: Width 2700 mm, Depth 1300 mm, Height 1575 mm
Water tank: Width 1100 mm, Depth 800 mm, Height 2200 mm
Feedthroughs
1 feedthrough ∅ 50 mm, installed on the left
Test chamber volume: approx. 500 liters
Codpfszh D S Rox Amhjha
Refrigerant R-404a
Electrical connection:
Rated voltage 3/N/PE AC 400V ± 10% 50Hz
Rated power approx. 26 kW
Rated current approx. 44.0 A (neutral conductor loaded)
Fuse 63 A gG, on-site
Weight approx. 890 kg net
For your safety as a buyer, the following information!
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will be subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data and specifications are subject to change!)
We will gladly answer any further questions you may have over the phone.
Listing
Borken
785 km
Climatic test chamber -70°C to +180°C
VötschVCS 7034-5 - 335 Liter
Call
Condition: used, Vötsch
Type: VCS 7034-5
Water-cooled climate test chamber
Test chamber volume: 335 liters
Performance for temperature tests:
Temperature range: -70 to +180°C
Time-related temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4
Rate of change:
Cooling: 6.7 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3000 W / at -20°C: 3000 W
Temperature calibration values: +23°C and +80°C
Performance for climate tests:
Temperature range: +10 to +95°C
Time-related temperature deviation: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Chsdpfx Amozg Tx Rshja
Time-related humidity deviation: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climate calibration values: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions: Width 580mm, Depth 765mm, Height 750mm
External dimensions: Width 870mm, Depth 1595mm, Height 1775mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10kW
Rated current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerant: R-404A / R-23
For your security as a buyer, please note the following:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions by telephone.
Listing
Borken
785 km
Climate test chamber 335 liters with humidity
VötschVCS 7034-5 -70°C bis +180°C
Call
Condition: good (used), Vötsch
Type: VCS 7034-5
Water-cooled climatic test chamber
Vötsch VCS 7034-5
Test chamber capacity 335 liters
Performance for temperature tests
Temperature range -70 to +180°C
Temperature deviation temporal K ±0.1 to ±0.5
Spatial temperature deviation K ±0.5 to ±2.0
Temperature gradient 1 to 4
Rate of change :
Cooling 6.7 K/min
Heating 6.8 K/min
Heat compensation at +20 °C 3000 W / at -20°C 3000 W
Temperature calibration values +23 °C and +80 °C
Performance for climate tests
Temperature range +10 to +95°C
Temperature deviation in time ±0.1 to ±0.3 K
Spatial temperature deviation ±0.5 to ±1.0 K
Temperature gradient 1 to 2 K
Humidity range 10 to 98%
Humidity deviation in time ±1 to ±3%
Dew point range -3 to +94°C
Heat compensation 400W
Climate calibration values +23 °C / 50 % r.h. and +95 °C / 50 % r.h.
Test chamber dimensions: Width 580mm Depth 765mm Height 750mm
External dimensions: Width 870mm Depth 1595mm Height 1775mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10kW
Rated current: 21 A
Sound pressure level: 64dB(A)
Chodpfx Amszg Twgjhja
Cooling water consumption: 1.4m³/h
Refrigerant: R-404A / R-23
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
785 km
Temperature test chamber
VötschVTS 7034-5
Call
Condition: good (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch Temperature Test Chamber, Water-Cooled
Temperature Range: -70°C to +180°C
Temperature Deviation (temporal): ±0.1 to ±0.5 K
Temperature Deviation (spatial): ±0.5 to ±2.0 K
Temperature Change Rate (cooling): 5.0 K/min
Temperature Change Rate (heating): 6.5 K/min
Heat Compensation at +20°C: 3000 W
Heat Compensation at -20°C: 3000 W
Test Chamber Dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External Dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Test Chamber Volume: 335 liters
Rated Voltage: 3/N/PE AC, 400V ±10%, 50Hz
Rated Power: 10 kW, Rated Current: 21 A
Sound Level at 1m Distance (Free-Field Measurement): < 69dB (A)
Side Feedthrough: 5.5 cm / 12.5 cm
Chodpfezg Tp Nsx Amhsa
Chamber is water-cooled.
Refrigerant: R-404A and R-23
Weight: approx. 570 kg
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components.
2. New filling with legally compliant refrigerant.
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used
Scope of Delivery: (See image)
(Changes and errors in the technical data and information are subject to change!)
We are happy to answer any further questions you may have by phone.
Listing
Borken
785 km
Temperature test chamber
VötschVTS 7034-5
Call
Condition: good (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch Temperature Testing Chamber, Water-Cooled
Temperature Range: -70°C to +180°C
Temperature Deviation (Temporal): ± 0.1 to ± 0.5 K
Temperature Deviation (Spatial): ± 0.5 to ± 2.0 K
Temperature Change Rate (Cooling): 5.0 K/min
Temperature Change Rate (Heating): 6.5 K/min
Heat Compensation at +20°C: 3000 W
Codpozg Tp Aofx Amhoha
Heat Compensation at -20°C: 3000 W
Test Chamber Dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External Dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Test Chamber Volume: 335 Liters
Rated Voltage: 3/N/PE AC, 400V ±10%, 50Hz
Rated Power: 10 kW, Rated Current: 21 A
Sound Pressure Level at 1m Distance (Free-Field Measurement): < 69dB (A)
Side Opening: 5.5 cm / 12.5 cm
Chamber is water-cooled
Refrigerant: R-404A and R-23
Weight: Approximately 570 kg
For your safety as a buyer, please note the following information:
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerants
3. After successful inspection, the chambers will be subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of Supply: (See Image)
(Changes and errors in the technical data are subject to change!)
We would be happy to answer any further questions you may have by phone.
Listing
Borken
785 km
Temperature test chamber
VötschVTS 7034-5
Call
Condition: good (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch Temperature Test Chamber, Water-Cooled
Temperature Range: -70°C to +180°C
Temporal Temperature Deviation: ± 0.1 to ± 0.5 K
Spatial Temperature Deviation: ± 0.5 to ± 2.0 K
Temperature Change Rate (Cooling): 5.0 K/min
Temperature Change Rate (Heating): 6.5 K/min
Thermal Compensation at +20°C: 3000 W
Thermal Compensation at -20°C: 3000 W
Test Chamber Dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External Dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Test Chamber Volume: 335 liters
Csdpfx Ajzg Tpiomhoha
Rated Voltage: 3/N/PE AC, 400V ±10%, 50Hz
Rated Power: 10 kW, Rated Current: 21 A
Sound Level at 1m Distance (Free Field Measurement): < 69dB (A)
Side Access: 5.5 cm / 12.5 cm
Chamber is water-cooled
Refrigerant: R-404A and R-23
Weight: approx. 570 kg
For your safety as a buyer, please note the following information:
The following steps are performed on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. Refilling with refrigerants compliant with legal regulations
3. After successful inspection, the chambers undergo a test run, which is monitored with calibrated equipment.
Condition: used
Scope of Supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have over the phone.
Listing
Borken
785 km
Temperature cabinet
VötschVTS 7011-5
Call
Condition: good (used), Vötsch
Type: VTS 7011-5
Heraeus Vötsch temperature control chamber, water-cooled
Test chamber volume: 110 liters
Test chamber dimensions: width 560 mm, depth 350 mm, height 630 mm
External dimensions: width 850 mm, depth 1030 mm, height 1640 mm
Temperature range: -70°C to +180°C
Temporal temperature deviation: ± 0.3 to 1 K
Spatial temperature deviation: ± 0.5 to ± 2 K
Temperature change rate (cooling): 6 K/min
Temperature change rate (heating): 10 K/min
Refrigerant: R-404 A / R 23
Voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 7.5 kW
Rated current: 13 A
Weight: 360 kg
For your security as a buyer, please note the following information:
The following points are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
Codezg Tpcspfx Amhjha
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We are happy to answer any further questions you may have by telephone.
Listing
Borken
785 km
Temperature test chamber 270 liters
VötschVTS³ 7027-25 -72°C bis +180°C
Call
Condition: excellent (used), Vötsch
Type: VTS³ 7027-25
Heraeus Vötsch temperature testing chamber, water-cooled
Performance data:
With a temperature change rate of 25 K/min
Test chamber dimensions: height 750 mm, width 580 mm, depth 615 mm
External dimensions: height 1775 mm, width 780 mm, depth 1895 mm
Temperature range: -72°C to +180°C
Temperature deviation (over time): ± 0.1 to ± 0.5
Temperature homogeneity (spatial): ± 0.5 to ± 2.0
Temperature change rate (cooling): 25 K/min
Temperature change rate (heating): 25 K/min
Heat compensation at -20°C: 8000 W
Heat compensation at +20°C: 8000 W
Chsdpfx Ajzg Eygsmhja
Test volume: 270 liters
2x side ports, diameter 125 cm
1x side port, diameter 50 cm
Chamber is water-cooled
Test chamber lighting:
LED strip 24 V, 6.8 W / 2x halogen bulb 24 V, 50 W
Electrical connection:
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 26 KW
Rated current: 44 A
Refrigerant: R-452A and R-23
Weight: approx. 980 kg
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See image)
(Changes and errors in the technical data and specifications are reserved!)
We will gladly answer any further questions you may have by phone.
Listing
Borken
785 km
Climate test chamber 335 liters 10-98% relative humidity.
VötschVC³ 0034 -10 °C bis +90 °C
Call
Condition: excellent (used), Vötsch VC³ 0034 Climate Test Chamber
Manufacturer: Vötsch Industrietechnik GmbH
Type: VC³ 0034
Machine Type: Climate Test Chamber / Climate Chamber
Test Chamber Volume: approx. 335 liters
For sale is a used climate test chamber from Vötsch for temperature and climate testing in laboratories, research, development, and quality assurance.
Technical Data
Test Chamber Dimensions: approx. 580 x 765 x 750 mm (W x D x H)
Housing Dimensions: approx. 875 x 1860 x 1805 mm (W x D x H)
Temperature Range: -10 °C to +90 °C
Humidity Range: 10 to 98 % RH
Dew Point Range: +4 °C to +89.5 °C
Temperature Homogeneity: ±0.5 to ±1 K
Temperature Deviation: ±0.1 to ±0.5 K
Heating Rate: approx. 1 K/min
Cooling Rate: approx. 0.3 K/min
Max. Heat Compensation: approx. 200 W
Refrigerant: R404A
Chodpfozgb Awex Amhsa
Filling Quantity: 0.6 kg
ND max.: 25 bar g
HD max.: 25 bar g
Power Connection: 230 V / 50 Hz
Rated Power: 2.3 kW
Rated Current: 10 A
Protection Class: IP54
Weight: approx. 490 kg
Equipment
SIMPAC control system
Temperature and humidity control
Stainless steel test chamber
Ethernet, USB, RS232, RS485/422
Test item protection function
Cable glands
Application Areas
Climate testing
Temperature testing
Material testing
Electronics testing
Quality assurance
Research and development
Scope of Supply
Vötsch VC³ 0034 Climate Test Chamber
Accessories as shown in the pictures
Condition
Used
Optical condition as shown in the pictures
For the safety of our customers, the offered climate chambers are tested before delivery,
if necessary, filled with legally compliant refrigerant, subjected to a leak test,
and delivered with a documented test run.
Subject to change and errors in technical data as well as prior sale.
Listing
Borken
785 km
Temperature test chamber 600 liters
Vötsch KlimaprüfschrankVC 4060 -40°C bis +180°C
Call
Condition: excellent (used), Vötsch VC 4060 Climate Testing Chamber
Manufacturer: Vötsch Industrietechnik GmbH
Type: VC 4060
Machine Type: Climate Testing Chamber / Temperature Testing Chamber
Test Chamber Volume: approx. 600 liters
Chedpfx Aozf E E Temhsa
Control System: S!MCON / 32
Cooling: water-cooled
Refrigerant: R452A
For sale is a used climate testing chamber from Vötsch.
The testing chamber is suitable for temperature and climate tests, environmental simulation,
material testing, quality assurance, as well as development and stress tests.
Technical Data
Test Chamber Dimensions: approx. 800 x 800 x 950 mm (W x D x H)
Housing Dimensions: approx. 1090 x 1960 x 1995 mm (W x D x H)
Weight: approx. 600 kg net
Temperature Range: -40 °C to +180 °C
Temperature Change Rate (Heating): approx. 4.0 K/min
Temperature Change Rate (Cooling): approx. 3.0 K/min
Temperature Deviation (Time): ±0.1 to ±0.5 K
Temperature Deviation (Spatial): ±0.5 to ±2 K
Temperature Gradient: approx. 1 to 4 K
Climate Range (Temperature): -10 °C to +95 °C
Humidity Range: 10 % to 98 % RH
Humidity Deviation: ±0.1 to ±3 % RH
Temperature Deviation (Climate Operation, Time): ±0.1 to ±0.3 K
Temperature Deviation (Climate Operation, Spatial): ±0.5 to ±1.0 K
Temperature Gradient (Climate Operation): approx. 1 to 2 K
Power Connection: 3/N/PE AC 400 V ±10 % / 50 Hz
Rated Power: 7.8 kW
Rated Current: 15.0 A
Fuse: 16 A slow-blow, on-site
1 cable entry Ø 50 mm installed on the left
1 cable entry Ø 125 mm installed on the right
Test chamber made of stainless steel
Touch panel operation
Equipment
S!MCON / 32 control system
Touch panel operation
Interior made of stainless steel
Test chamber lighting
Side cable entries Ø 50 mm and Ø 125 mm
Shelving / test chamber equipment as shown in the pictures
Water-cooled system
Documentation / operating manual
Accessories as shown in the pictures
Application Areas
Temperature testing
Climate testing
Environmental simulation
Material testing
Electronics testing
Quality assurance
Research and development
Scope of Supply
1x Vötsch VC 4060 Climate Testing Chamber
Documentation / operating manual
Accessories as shown in the pictures
Condition
Used
Optical condition as shown in the pictures
Inspection possible by appointment
Note: The unit has been converted to use R452A refrigerant.
Scope of supply as pictured.
Subject to changes and errors in the technical data, as well as prior sale.
Listing
Borken
785 km
Temperature test chamber
VötschVTS³ 7018-5
Call
Condition: excellent (used), Vötsch
Type: VTS³ 7018-5
Water-cooled
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 900 mm x Depth 1550 mm x Height 1850 mm
Temperature testing:
Temperature range: -70°C to +180°C
Temperature change rate: Heating 7.5 K/min
Temperature change rate: Cooling 7.5 K/min
Test chamber volume: 190 liters
Rated voltage: 400 V
Rated current: 20 A
Rated power: 9 kW
Weight: approx. 540 kg
Refrigerant: R404A and R23
For your safety as a buyer, please note the following information:
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerants
3. Leak test with certificate
4. After successful inspection, the chambers will be subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and specifications are reserved!)
We will be happy to answer any further questions you may have by phone.
Chsdpfxezfg Ucj Amhja
Listing
Borken
785 km
Shock test chamber
VötschVT 7012 S3
Call
Condition: excellent (used), Vötsch Shock Test Chamber
Here we offer you a Vötsch shock test chamber.
Water-cooled
Temperature range: -80°C to +220°C
Warm chamber: +50 to +220
Intermediate chamber: -10 to +90
Cold chamber: -80 to +70
Supply voltage: 400V ±10% 3/N 50Hz
Rated current: 30.5 A
Rated power: 13.5 kW
Codjzd Uzuepfx Amhsha
Refrigerant VK: R 404A 3.00 kg p*: 25 bar
Refrigerant TK: R23 15 bar p*: 25 bar
Condition: used
Type: VT 7012 S3
For your security as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We would be happy to answer any further questions you may have by phone.
Listing
Borken
785 km
Temperature test chamber 335 liters
VötschVTS 7034-5 -70°C bis +180°C
Call
Condition: excellent (used), Heraeus Vötsch Temperature Test Chamber
Here we offer you a Heraeus Vötsch temperature test chamber.
Heraeus Vötsch Temperature Test Chamber, Water-Cooled
Temperature range: -70°C to +180°C
Temperature deviation (temporal): ±0.1 to ±0.5 K
Temperature deviation (spatial): ±0.5 to ±2.0 K
Temperature change rate (cooling): 5.0 K/min
Temperature change rate (heating): 6.5 K/min
Heat compensation at +20°C: 3000 W
Heat compensation at -20°C: 3000 W
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Test chamber volume: 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10 kW, Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Side feedthrough: 5.5 cm / 12.5 cm
Chamber is water-cooled
Refrigerant: R 452A and R 23
Weight: approx. 570 kg
Type: VTS 7034-5
For your security as a buyer, please note the following:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Cedszd R Tgepfx Amheha
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have on the phone.
Listing
Borken
785 km
Temperature cabinet 110 liters
VötschVT 7011 -70°C bis +180°C
Call
Condition: excellent (used), Here we offer a Heraeus Vötsch temperature control chamber.
Heraeus Vötsch temperature control chamber, water-cooled
Test chamber volume: 110 liters
Test chamber dimensions: Width 560 mm, Depth 350 mm, Height 630 mm
External dimensions: Width 850 mm, Depth 1030 mm, Height 1640 mm
Temperature range: -70°C to +180°C
Temporal temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±1.5 K
Temperature gradient: 1 to 3 K
Temperature change rate (cooling): 3.2 K/min
Temperature change rate (heating): 3.5 K/min
Refrigerant: R-404 A / R 23
Voltage: 1/N/PE AC 230V ±10% 50Hz
Rated power: 1.8 kW
Rated current: 12 A
Type: VT 7011
Chodpfxjzdtd Ij Amhsa
For your safety as a buyer, please note the following information:
The following steps are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We would be happy to answer any further questions you may have by phone.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
785 km
Temperature test chamber 190 L
Heraeus VötschTemp. -70°C bis + 180°C VTS 7018-5
Call
Condition: excellent (used), Here we offer you a Heraeus Vötsch temperature testing chamber.
Heraeus Vötsch temperature testing chamber, water-cooled
Temperature range: -70°C to +180°C
Temperature deviation (time-related): ±0.1 to ±0.5 K
Temperature deviation (spatial): ±0.5 to ±2.0 K
Temperature change rate (cooling): 7.5 K/min
Temperature change rate (heating): 7.5 K/min
Thermal compensation +20°C: 3000 W
Thermal compensation -20°C: 3000 W
Test chamber dimensions: Width 580 mm, Depth 450 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1280 mm, Height 1575 mm
Observation window:
Width 300 mm x Height 540 mm
Test chamber volume: 190 liters
Rated voltage: 3/N/PE AC, 400 V ±10 %, 50 Hz
Rated power: 10.5 kW, Rated current: 22 A
Fuse, on customer side: 32 A, slow-blow
Chjdpfxjzdtdhs Amhea
Sound pressure level at 1 m distance (free-field measurement): < 69 dB(A)
Side access: 50 cm / 125 cm
Chamber is water-cooled
Refrigerant: R 404A and R 23
Weight: approx. 460 kg
Type: VTS 7018-5
For your security as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. Refilling with refrigerants that comply with legal regulations
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have over the phone.
Listing
Borken
785 km
Shock test chamber –80 °C to +220 °C
VötschVT 7012 S2
Call
Condition: excellent (used), Vötsch Temperature Shock Testing Chamber
Type: VT 7012 S2
Manufacturer: Vötsch Industrietechnik GmbH
Design: Water-cooled
For sale is a two-chamber temperature shock testing chamber from Vötsch, designed for rapid temperature change tests. Suitable for industrial, automotive, aerospace, as well as research and development applications.
Temperature Ranges:
Hot Chamber: +50 °C to +220 °C
Cold Chamber: -80 °C to +70 °C
Temperature Data:
Temporal temperature deviation: ±1 K
Spatial temperature deviation: ±2 K
Heating rate, hot chamber: approx. 11 K/min
Heating rate, cold chamber: approx. 2 K/min
Cooling rate: approx. 3 K/min
Test Chamber:
Volume: approx. 125 liters
Internal dimensions: approx. 470 x 650 x 410 mm
Cable entry: Ø 67 mm
Electrical Data:
Connection: 3/N/PE AC 400 V ±10% / 50 Hz
Rated power: approx. 10 kW
Rated current: approx. 25 A
Chodpfxoy Iyuwe Amhoa
Refrigerant:
R404A: 2.9 kg
R23: 1.27 kg
Pressure Data:
ND max.: 22.5 bar
HD max.: 25 bar
Dimensions:
approx. 930 x 2115 x 1970 mm
Weight:
approx. 1000 kg
Equipment:
Two-chamber shock testing system
Digital control
Program operation
Observation window
Cable entry
Condition:
Used
Optical condition as shown in the pictures
Normal storage and usage marks present
Scope of delivery:
Vötsch VT 7012 S2 temperature shock testing chamber
Accessories as shown in the pictures
Important Note:
All information has been provided to the best of our knowledge based on the pictures, nameplates, and manufacturer information.
Shipping is possible.
Subject to changes, errors and prior sale.
We are happy to answer any further questions by phone.
Listing
Eindhoven
733 km
Climate test chamber
Vötsch/WeissGTTS 220
Call
Condition: used, Year of construction: 1980, functionality: unexamined, machine/vehicle number: GTTS 220, total height: 144 mm, total length: 135 mm, total width: 96 mm, Equipment: documentation/manual, Used Votsch/Weiss GTTS 220 Climate Chamber
Manufacturer: Votsch/Weiss
Model: GTTS 220 | 20
External dimensions: 135cm x 96cm x 144cm (length x width x height)
Max internal dimensions: 65cm x 92cm x 54/40cm (width x depth x height)
Chodpfx Amsx H N Drjhoa
Voltage: 220/380 V
Refrigerant type: R12
Includes manual (installation and operation handbook)
Listing
Wymysłów
1,472 km
Vötsch VT 7004 – climatic chamber / temperature chamber
Vötsch VT 7004 – komora klimatyczna / komora temperaturowaVötsch VT 7004 – komora klimatyczna / komora temperaturowa
Call
Condition: excellent (used), For sale: a Vötsch VT 7004 climate chamber, designed for precise research and testing under controlled temperature conditions. This unit is suitable for use in laboratories, quality control departments, materials research, electronics, and the automotive industry.
The chamber is equipped with an electronic temperature controller, an efficient cooling system, and a forced air circulation system that ensures uniform temperature distribution throughout the working chamber. The interior is made of stainless steel, which facilitates cleaning and ensures high durability.
Technical data:
Manufacturer: Vötsch Industrietechnik GmbH
Model: VT 7004
Year of manufacture: 2000
Device number: 58566024350010
Power supply: 230 V AC, 50 Hz
Rated power: 2.0 kW
Rated current: 10 A
Refrigerant:
R404A – 0.7 kg
R23 – 0.22 kg
Maximum working pressure: 25 bar
Interior: stainless steel
Electronic temperature controller
Forced air circulation
Door with silicone seal
Lighting and service access port in the chamber
Compact design
Condition:
Chjdpfx Ajzi U Tnjmhoa
Used unit.
Visually in good condition.
The chamber is clean and complete.
Sold in the exact condition as shown in the pictures.
We make it easier for you to find: "vötsch vtr 7033/s"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
This may be of interest to you