Used Vötsch Vcl 4003 for sale (158)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Wald
1,198 km
Climate test chamber, climatic chamber
VötschVCL 4003
Call
Condition: ready for operation (used), Vötsch VCL 4003 Climate Chamber
Test chamber volume: 34 liters
Weight: 110 kg
Rated power: 1.8 kW
Temperature range: -40 to +180 °C
For further technical data, please refer to the images.
We were unable to carry out a full test of the device, as the touch screen switches off after a certain period.
Ncjdoxw Srqopfx Adtsr
The device likely requires new software.
For this reason, the device is being sold as defective.
You are welcome to arrange an inspection appointment.
We can also organize affordable shipping for you!
You will receive a proper invoice.
Net invoices can be issued for foreign customers, provided you supply a valid VAT ID.
Subject to prior sale.
Visit our shop to see our other listings as well.
The company names and trademarks mentioned are the property of their respective owners and are used solely for identification and description purposes.
Deviations from technical data as well as errors in the item description may occur and are reserved.
Listing
Borken
785 km
Climate test chamber with humidity 34 liters
VötschVCL 7003 -70°C bis +180°C
Call
Condition: excellent (used), Vötsch
Type: VCL 7003
Air-cooled climatic test chamber
Test chamber capacity approx. 34 liters
Capacity for temperature tests:
Temperature range -70 to +180°C
Temperature deviation over time ±0.3 to ±1.0 K
Temperature homogeneity over space ±0.5 to ±2.0 K
Heating rate of change 4.0 K/min
Cooling rate of change 3.0 K/min
Heat compensation max. 550 W
Temperature calibration value +23°C and +80°C
Capacity for climatic tests:
Temperature range +10 to +95°C
Humidity range 10 to 98%
Humidity deviation over time ±1 to ±3%
Temperature deviation over time ±0.3 to ±0.5 K
Spatial temperature homogeneity ±0.5 to ±1.5 K
Climate calibration values +23 °C / 50% RH and +95 °C / 50% RH
Test room dimensions: Width 350 mm, Depth 300 mm, Height 310 mm
External dimensions: Width 640 mm, Depth 750 mm, Height 1730 mm
Electrical connection:
1/N/PE AC 230 V ±10%, 50 Hz
Rated current 11.0 A
Rated power, max. 2.5 kW
Sound pressure level 59 dB(A)
Refrigerant: R-404 A / R23
Weight approx. 130 kg
For your safety, please note the following information as a buyer!
The following steps are performed on our chambers in advance:
1. Functional testing and replacement of necessary components
Ncodpfx Adov Tnd Setor
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Sheffield
256 km
Microwave Oven
VötschMicrowave Oven
Call
Year of construction: 2012, operating hours: 75 h, condition: like new (used), This Vötsch Hephaistos Industrial Microwave Chamber has had extremely low hours usage during its life so far, on 75 hours .. having been installed and minimally utilized from time to time for a single research project at the University of Sheffield AMRC research department known as the “Factory of the Future”. Sold new for a price of approx 250,000.00Euro. Contact us now for an exceptional offer for this high tech unit in as new condition.
VHM Hephaistos Industrial Microwave Chamber For Aerospace and Automotive Engineering
The Research Project
The VHM Hephaistos Industrial Microwave Chamber for component testing was developed in cooperation with the Karlsruhe Institute of Technology (KIT). It is the result of a joint development project sponsored by the German Federal Ministry of Education and Research (BMBF). Alongside KIT, the Composite Research Center of EADS in Munich, the Institute for Aircraft Design (IFB) at the University of Stuttgart, GNK Aerospace in Munich and Vötsch Industrietechnik were involved in the project.
Microwave system
The VHM Hephaistos Industrial Microwave Chamber from Vötschtechnik is an internationally patented system. Fast and energy-efficient production processes are possible by using microwaves. The microwave chamber is characterized by its hexagonal geometry with a very high field homogeneity. This is a major advantage when thermoforming fibre composites (CFRPs) in the aerospace and automotive industries.
During the targeted volumetric heating of the products, the microwaves directly enter the material so that energy is delivered directly and the chamber does not require heating. This increases the heating rate and throughput, saving energy and time in addition.
Reduced production costs
This industrial microwave chamber guarantees you reduced costs due to shorter heating, process and cooling times required for curing CFRP components. Its material processing technology means the microwave can produce energy input into the component to be heated while the oven itself remains cold. In comparison to the process in autoclaves, the processing times are reduced by up to 50 %. Energy consumptions is reduced by up to 70%.
Advantages:
Possibility to use metal parts, such as conventional metal tools and feed systems, in the microwave field
High degree of product quality thanks to the maximum homogeneity of the microwave fields provided by the hexagonal chamber structure. By using microwave absorbing materials, additional positive effects can be achieved
Sizes from laboratory scale to large systems, e.g. as are required in the aerospace industry, can be achieved
The modular design allows a flexible adjustment to your product
Nedpfetvz Rfox Adtecr
Volumetric and selective heating for energy-efficient processes
Precise heating of the products
Hybrid systems, e.g. in combination with hot air
Listing
Borken
783 km
Vötsch VTU 60/60 drying oven 250°C
VötschVötsch VTU 60/60
Call
Year of construction: 2010, condition: good (used), Here we offer a Vötsch VTU 60/60 drying oven.
Vötsch VTU 60/60 drying oven
Nominal temperature: 250°C
Nedpfx Adjn Hqg Djtocr
Interior dimensions: width 600 mm height 600 mm depth 600 mm
Outer dimensions: width 1000 mm height 1675 mm depth 1300 mm
Supply voltage: 400 V 3 (N) PE AC, 50/60 Hz
Type: VTU 60/60
Listing
Borken
785 km
Climate chamber optimized for battery tests
VötschVCZ 60006/-1/S -60 bis +160
Call
Condition: good (used), Vötsch
The unit was used for battery testing.
Inert gas connection and pressure compensation flap.
+Fresh air purge approx. 100 m³/h
Water-cooled
Model: VCZ 60006/-1/S
Large-capacity chamber for temperature and climate testing
Test chamber volume: approx. 7.5 m³
Interior dimensions: approx. height 1480 mm, width 2470 mm, depth 2050 mm
External dimensions: approx. height 2400 mm, width 3200 mm, depth 4270 mm
Test chamber floor load capacity: 3000 kg/m²
Njdpoyzpa Nofx Adtscr
Temperature testing data:
Temperature range: -40°C to +160°C
Heating rate from -40 to +100°C: approx. 1 K/min
Cooling rate from +100 to -40°C: approx. 1.5 K/min
Heat compensation from -40°C to +20°C: 8000 W
Climate testing data:
Temperature range: +10 to +80°C
Humidity range: 10 to 90 % r.h.
Dew point range: +5 to +77.4°C
Temperature deviation over time: +/-0.1 to +/-0.5 K
Humidity deviation over time: +/-3 to +/-5% r.h.
Operational data:
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal power: 25 kW
Nominal current: 41 A
Weight: 3500 kg
Refrigerants: R-404A / R-23 6.5 kg & 3.2 kg
For your safety as a buyer, please note the following information:
The following steps are performed on all chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. Leak test with certificate
3. After successful inspection, the chambers are subjected to a test run, monitored with calibrated instruments.
Condition: used
Scope of delivery: (see picture)
(Technical data and specifications subject to change and errors excepted!)
If you have any further questions, we would be happy to answer them by phone.
Listing
Borken
783 km
Vötsch climatic test chamber Fitotron HGC1014
Vötsch Klimaprüfschrank 5°C bis +45°Fitotron HGC 1014 V Schrank 3 mit Bel.
Call
Condition: excellent (used), functionality: fully functional, Year of construction: 2012, Fitotron® Modular Plant Growth Chambers, Type HGC 1014 V, including HQI-T and Krypton Lighting Module
Temperature range +5°C - +45°C for temperature testing
Test chamber volume approx. 1300 l
Simpac Control System
Network Connection
USB Connection
The Fitotron® HGC series plant growth chambers are based on a modular design. Individual modules can be added or replaced as needed. This allows them to be adapted to different applications. They are suitable for plants with high light requirements, such as wheat, corn, cotton, rice, and C4 plants.
Lighting HQI-BT-400 W/D and 100 W,
Temperature range +5°C to +45°C
Temperature deviation over time ± 0.5 K
Humidity range 40% to 95%
Dew point range +4°C to +35°C
Humidity deviation over time ± 3 to 5% RH
Fresh air up to 7.5 m³/h
Power consumption without fresh air operation at 25°C / 75% RH approx. 0.8 kW
Njdpfx Adjvz U Erstjcr
Characteristics for climatic tests with irradiation
Temperature range +10°C to +45°C with light on +10°C to +45°C
Temperature deviation over time ± 0.5 K
Humidity range 40% to 95%
Dew point range +4°C to +35°C
Humidity deviation over time ± 3 to 5% RH
Humidification and dehumidification system, stainless steel test chamber
Internal dimensions: Height 1400 mm, Depth 750 mm, Width 1270 mm
External dimensions: Height 1985 mm, Depth 980 mm, Width 2320 mm
External dimensions with lighting module: Height 2450 mm
Single door with observation window
Interface for computer connection
Connection 3/N/PE 400V ±10% 50Hz
CE marking, mobile, very good condition
Pipe penetration ∅ 50 mm
Air cooling
Refrigerant R404A
Weight approx. 480 kg + 130 kg lighting module
Listing
Borken
785 km
Tabletop test cabinet 35 liters
VötschVT 4004 -40°C bis +180°C
Call
Condition: excellent (used), Vötsch Climate Test Chamber VT 4004
Tabletop Test Cabinet -40°C to +180°C
For sale is a high-quality climate test chamber / tabletop test cabinet by the renowned manufacturer Vötsch Industrietechnik (Model VT 4004).
This device is ideal for use in laboratories, R&D, or industrial settings and is perfectly suited for the simulation of temperature conditions when testing electronics, components, and materials.
Functions & Application Areas:
- Temperature testing in the range from -40°C to +180°C
- Uniform temperature distribution via recirculating air system
- Combination of cooling and heating
- Digital control with display
- Compact tabletop design (approx. 35-liter interior)
- RS232 interface for connection to PC or measurement systems
Nodpfxsywg Ame Adtecr
Technical Data:
Manufacturer: Vötsch Industrietechnik
Type: VT 4004
Volume: approx. 35 liters
Cooling: air-cooled
Refrigerant: R404A
Electrical Data:
Voltage: 1/N/PE AC 230V ±10% / 50 Hz
Rated power: approx. 1.5 kW
Rated current: approx. 7.5 A
Dimensions:
External: Width: 95 cm, Height: 63 cm, Depth: 83 cm
Interior: Width: 32 cm, Height: 40 cm, Depth: 27 cm
Condition: used
Scope of delivery: (please see photo)
(Specifications and details subject to change and error!)
For further questions, please feel free to contact us by phone.
Listing
Borken
785 km
Temperature test chamber 190 L
Heraeus VötschTemp. -70°C bis + 180°C VTS 7018-5
Call
Condition: excellent (used), Here we offer you a Heraeus Vötsch temperature test chamber.
Heraeus Vötsch temperature test chamber water cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ±0,1 to ±0,5 K
Temperature deviation in time ±0.5 to ±2.0 K
Temperature change rate cooling 7.5 K/min
Temperature change rate heating 7.5 K/min
Heat compensation +20°C 3000 W
Heat compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 450 mm Height 750 mm
Outer dimensions: Width 870 mm Depth 1280 mm Height 1575 mm
Observation window:
Width 300 mm x height 540 mm
Test chamber volume 190 litres
Rated voltage: 3/N/PE AC, 400 V ±10 %, 50Hz
Ncjdpfxshh H His Adtor
Rated power: 10.5 kW Rated current: 22 A
Fuse, on-site: 32 A slow-blow
Sound level at 1m distance (free field measurement) < 69dB (A)
lateral feed-through 50 cm / 125 cm
Cabinet is water cooled
Refrigerant: R 404A and R 23
Weight approx. 460 kg
Type: VTS 7018-5
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. function check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer gladly on the phone for you.
Listing
Borken
785 km
Temperature test chamber 190 L
Heraeus VötschTemp. -70°C bis + 180°C VTS 7018-5
Call
Condition: excellent (used), Heraeus Vötsch Type: VTS 7018-5 Heraeus Vötsch Temperature Test Chamber, Water-Cooled Temperature range: -70°C to +180°C Temporal temperature deviation: ± 0.1 to ± 0.5 K Spatial temperature deviation: ± 0.5 to ± 2.0 K Temperature change rate (cooling): 6.5 K/min Temperature change rate (heating): 7.5 K/min Heat compensation: 4,500 W Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm External dimensions: Width 870 mm x Depth 1,280 mm x Height 1,575 mm Viewing window: Width 300 mm x Height 540 mm Test chamber volume: 190 liters Rated voltage: 3/N/PE AC, 400V ±10%, 50Hz Rated power: 10 kW Rated current: 21 A Supply-side fuse: 32 A slow-blow Sound level at 1 m distance (free-field measurement): < 63 dB(A) Lateral port: 50 cm / 125 cm Chamber is water-cooled Refrigerants: R452A and R23 Weight: approx. 460 kg Important safety information for buyers: The following procedures are carried out on all chambers offered by us: 1. Functional check and replacement of necessary components 2. If required, refilling with legally compliant refrigerant 3. Leak test with certificate 4. After successful inspection, all chambers are subjected to a documented trial run. Condition: used Scope of delivery: (see photos) (Technical data and specifications subject to change and errors!) If you have further questions, we are happy to provide information by phone.
Ncjdpjyu Rhgjfx Adtsr
Listing
Meiningen
1,071 km
Recirculating chamber oven 200°C, electric oven
VötschVTU 375/230/135 mit 11,6m³
Call
Condition: good (used), functionality: fully functional, Year of construction: 2017, 2 pieces recirculating chamber ovens, electric, 12-month warranty
- Temperature: 200°C; upgrade to 250°C available on request
- Charging carts: 5 units included; conversion on request
- Internal dimensions (WxDxH): 3750 x 1350 x 2300 mm
Nedpfx Adsy Avqwstscr
- External dimensions (WxDxH): 4850 x 3880 x 1705 mm
- Usable volume: 11.6 m³
- Control: S!MPAC with touch panel
- Program execution via product sensor with cascade control
- Temperature limiter
- Signal tower
- Direct drive-in, grid rails
- Exhaust air flow rate: 140 m³/min
- Electromagnetic door lock
- Rated power: 180 kW
- Connection: 241 kW
- Weight: approx. 3,500 kg
- Documentation, CE declaration of conformity
We are happy to offer transport, installation, and staff training.
Viewing by appointment at our machinery hall is possible at any time.
Oven, ovens, drying oven, industrial furnace, drying cabinet, heating oven, heating cabinet, recirculating oven, chamber oven, heating chamber, recirculating chamber oven, tempering oven, annealing oven.
Listing
Germany
1,148 km
Temperature cabinet -40°C to +130°C
Heraeus VötschHT4002 16 Liter
Call
Year of construction: 1995, condition: used, Temperature Chamber, Benchtop Test Chamber for Thermal Testing
Manufacturer: Heraeus Vötsch
Model: HT4002
Year of manufacture: 1995
Ncedpfjyyvphox Adtor
Test volume: 16 liters
Temperature range: -40°C to +130°C
Mains voltage: 230V
Refrigerant: VK R452a
Interface: RS232
Weight: 75 kg
External dimensions (WxDxH): 465 x 505 x 625 mm
Internal dimensions (WxDxH): 310 x 230 x 205 mm
ID: ä16426
Listing
Borken
785 km
Industrial tempering oven / heat chamber
VötschVTL 200/250/225 250°C 11 m³
Call
Condition: excellent (used), Vötsch
Vötsch Industrial Tempering Oven VTL 200/250/225
250°C 11.25 m³ 58 kW – Heat Chamber
The oven will be available at a later date.
Description:
For sale is an industrial tempering oven / heating cabinet from
Vötsch Industrietechnik GmbH.
This unit is ideally suited for industrial tempering, drying, and heat treatment processes.
Thanks to its large useful chamber, it is possible to process large or multiple components simultaneously.
The oven is controlled by a JUMO IMAGO 500 controller, enabling precise
temperature management and automated programs.
Typical fields of application:
Industrial production
Plastics and metal processing
Component drying
Heat treatment
Testing technology / Material testing
Laboratory and research applications
The system is of robust industrial quality and designed for continuous operation.
Technical data:
Manufacturer: Vötsch Industrietechnik GmbH
Model: VTL 200/250/225
Maximum temperature: 250 °C
Temperature safety classes:
TB Class 1
TWB Class 2
Interior:
Usable volume: 11.25 m³
Internal dimensions: Width: 2000 mm, Height: 2500 mm, Depth: 2250 mm
External dimensions: Width: 2900 mm, Height: 3530 mm, Depth: 2700 mm
Load capacity:
Internal chamber load capacity: 400 kg
Floor surface load: 1000 kg
Weight:
Net weight: 1850 kg
Electrical data:
Connection:
3/N/PE AC 400 V ±10% / 50 Hz
Rated current: 90 A
Rated power: 54 kW
Connected load: 58 kW
Additional data:
Minimum exhaust air volume: 600 m³/h
Reduced exhaust air volume: 150 m³/h
Purge time: 465 s
Total steam space: 14.9 m³
Sound pressure level: < 70 dB(A)
Temperature limiter shut-off temperature: 280 °C
Selectable temperature limiter: 270 °C
Weight: 1850 kg
Nodsytrzfspfx Adtocr
Condition: used
Scope of delivery: (See picture)
(Technical data subject to change and errors excepted!)
Any further questions can be answered by phone.
Listing
Meiningen
1,071 km
Paint dryer DIN 1539 300°C
VötschVTL 100/150 nach DIN 1539
Call
Condition: refurbished (used), Year of construction: 2001, functionality: fully functional, with safety system for solvent-containing substances in accordance with DIN 1539, including exhaust air fan, supply air cage filter, and concentration monitoring, as well as a recirculating air filter wall inside the unit
Completely overhauled, 12 months warranty
-Internal dimensions (w x d x h): 1000 x 1000 x 1500 mm
-External dimensions (w x d x h): 1900 x 1430 x 2315 mm
-Capacity: 1500 liters
-Max. temperature: 300°C
-Eurotherm Controller 2404 (20 programs with 16 segments each)
-Eurotherm Recorder
-Connection load: 29 kW
-Including 6 grid shelves and V2A stainless steel support brackets
Nodpfx Adevcb U Aotjcr
-Minimum exhaust air flow: 360 m³/h
-Maximum allowable solvent quantity: 36 g at nominal temperature of 300°C
-Including concentration measurement
-Window seals renewed
-Net weight approx. 1200 kg
-Including documentation, CE declaration
-Electrically tested and supplied with DGUV test protocol
Inspection at our warehouse by appointment.
We supply new and used industrial ovens. Contact us for more information!
Oven, ovens, drying oven, kiln, heat oven, heating cabinet, industrial oven, paint dryer, tempering oven, heating oven, tempering oven, drying cabinet, chamber furnace, baking oven, recirculating air drying cabinet, recirculation oven, solvent oven
Listing
Borken
785 km
Climate test chamber 335 liters with humidity
VötschVCS³ 7034-5 -70°C bis +180°C
Call
Condition: excellent (used), Vötsch
Njdpfxoygvn Ns Adtscr
Model: VCS³ 7034-5
Vötsch Climate Test Chamber, Water-Cooled
With temperature change rate of 5 K/min
Specifications for temperature testing:
Temperature range: -70°C to +180°C
Temporal temperature deviation in the center of the usable space: ±0.1 K to ±0.5 K
Spatial temperature deviation: ±0.5 K to ±2.0 K
Temperature change rate:
Heating: 6.8 K/min
Cooling: 6.7 K/min
Specifications for climate testing:
Temperature range: +10°C to +95°C
Temporal temperature deviation in the center of the usable space: ±0.1 K to ±0.3 K
Spatial temperature deviation: ±0.5 K to ±1.0 K
Temporal humidity deviation in the center of the usable space: ±1% to ±3% RH
Humidity range: 10% to 98% RH
(Extended climate range: 2°C/95% RH regulated for a maximum of 2 hours)
Exterior dimensions (W x D x H): 870 x 1700 x 1775 mm
Test chamber dimensions (W x D x H): 580 x 765 x 750 mm
Test chamber volume: approx. 335 liters
Side ports: 50 mm and 125 mm
Operating data:
LED strip 24 V, 6.8 W / 2 x halogen bulbs 24 V, 50 W
Rated voltage: 3/N/PE AC 400 V ±10%, 50 Hz
Rated power: 9 kW Rated current: 20 A
Customer-side fuse: 63 A slow-blow
Refrigerant: R404A / R-23
Weight approx. 570 kg
For your security as a buyer, please note the following:
The following procedures are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant, if needed
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see image)
(Technical data and information subject to change and errors!)
Further questions can be answered by phone.
Listing
Borken
785 km
Temperature test chamber 990 liters
VötschVT³ 4100 -40°C bis +180°C
Call
Condition: excellent (used), Vötsch
Model: VT³ 4100
Water-Cooled Temperature Test Chamber
Nodpfxeygvm Es Adtocr
S!MCON/32.NET (with Touch Panel)
Control System Features:
- Color touchscreen with intuitive menu navigation (typically 5.7" or larger)
- Programming of temperature/humidity profiles with ramps and dwell times
- Data acquisition & logging (e.g., temperature profile, alarms)
- USB port for data export (CSV, optionally S!MPATI compatible)
- Network interface (Ethernet) for remote monitoring and control
- User management with password protection
- Interfaces: Volt-free contacts, optionally Modbus or Profibus
VT³ 4100 – Technical Specifications (Temperature Test Chamber)
- Test volume: 990 liters
- Temperature range: -40 °C to +180 °C
- Temporal temperature deviation: ±0.1 to ±0.5 K
- Spatial temperature deviation: ±0.5 to ±1.5 K
- Temperature gradient: 1 to 3 K
- Temperature change rate (per IEC 60068-3-5):
• Heating: 4.0 K/min
• Cooling: 3.0 K/min
- Maximum heat compensation capacity: 4500 W
- Calibration values: +23 °C and +80 °C
- Internal dimensions (W×D×H): 1100 × 950 × 950 mm
- External dimensions (W×D×H): 1390 × 1955 × 1995 mm
Feed-Throughs:
The chamber is equipped with feed-throughs on both the right and left sides, allowing insertion of measuring cables and test devices into the test space.
• 1 × L1 nominal width 50 mm
• 1 × R1 nominal width 125 mm
• 3 × R1 nominal width 50 mm
Electrical connection: 3/N/PE AC, 400V ±10%, 50Hz
Power consumption: 11.5 kW
Rated current: 22 A
Noise level: approx. 62 dB(A)
Refrigerant: R452A
Weight: 920 kg
Important information for buyers:
For your security, the following measures are carried out on all our offered chambers prior to sale:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant, if needed
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run
Condition: used
Scope of delivery: (see picture)
(Subject to change and errors in technical data; information may be subject to alteration!)
For any further questions, feel free to contact us by phone.
Listing
Borken
785 km
Temperature test chamber 1540 liters
VötschVT³ 4150 -40°C bis +180°C
Call
Condition: excellent (used), Vötsch
Model: VT³ 4150
Vötsch Temperature Test Chamber, Air-Cooled
Temperature Testing
Temperature Range: -40°C to +180°C
Rate of Change: Cooling approx. 2.5 K/min
Rate of Change: Heating approx. 3.5 K/min
External Dimensions (W x D x H): approx. 1390 x 2380 x 1995 mm
Test Chamber Dimensions (W x D x H): approx. 1100 x 1475 x 950 mm
Rated Voltage: 3/N/PE AC, 400 V ±10%, 50 Hz
Rated Power: 11.5 kW
Rated Current: 22.0 A
Weight: approx. 1020 kg / 1540 liters
Refrigerant: R 404A
Nsdpfoygux Tjx Adtscr
For your safety as a buyer, please note the following information:
We perform the following steps on all chambers offered:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: Used
Scope of delivery: (see photo)
(Technical data subject to change and errors excepted!)
For further questions, feel free to contact us by phone.
Listing
Borken
785 km
Climatic chamber
VötschVC³ 4100
Call
Condition: excellent (used), Vötsch Climate Test Chamber
We offer a Vötsch climate test chamber.
Model: VC³ 4100, air-cooled
With a temperature change rate of 3 K/min
Test chamber internal dimensions: Height 950 mm x Width 1100 mm x Depth 950 mm
External dimensions: Height 2000 mm x Width 1300 mm x Depth 1916 mm
Chamber volume: 990 liters
Feed-throughs: Ø 125 mm, Ø 50 mm
Specifications for temperature tests:
- Temperature range: -42°C to +180°C
Ncsdpfxoyguw Ns Adtor
- Temporal temperature deviation: ±0.1 to ±0.5 K
- Spatial temperature uniformity: ±0.5 to ±1.5 K
- Temperature change rates:
- Heating: 4.0 K/min
- Cooling: 3.0 K/min
- Maximum heat compensation at +20°C: 4500 W
Specifications for climate tests:
- Temperature range: +10°C to +95°C
- Dew point range: -3°C to +94°C
- Humidity range: 10 to 98% r.H.
- Temporal temperature deviation: ±0.1 to ±0.3 K
- Spatial temperature uniformity: ±0.5 to ±1.0 K
- Temporal humidity deviation: ±1 to ±3% r.H.
- Max. heat compensation: 500 W
Power supply: 3/N/PE AC 400V ±10% 50Hz
Nominal power: 11.5 kW
Nominal current: 22.0 A
Refrigerant: R-404A
Weight: approx. 840 kg
Type: VC³ 4100
Important buyer information:
The following procedures are carried out on all our chambers prior to sale:
1. Functional checks and replacement of necessary components
2. If required, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run
Condition: used
Scope of delivery: (See picture)
(Technical data subject to change and errors excepted!)
For further questions, please feel free to contact us by phone.
Listing
Borken
785 km
Temperature test chamber
VötschVT³ 4150/S
Call
Condition: excellent (used), Vötsch
Model: VT³ 4150/S
Vötsch Temperature Test Chamber
Water-cooled
Rated voltage: 3/N/PE AC, 400 V ±10%, 50 Hz
Rated power: 11.5 kW; Rated current: 22.0 A
Change rate (cooling): approx. 3.5 K/min
Change rate (heating): approx. 4 K/min
Temperature testing
Temperature range: -40°C to +180°C
Layout drawing
Nsdpfjyguuzex Adtscr
External dimensions (W x D x H): approx. 1390 x 2380 x 1995 mm
Test chamber dimensions (W x D x H): approx. 1100 x 1475 x 950 mm
Weight: approx. 1020 kg / 1540 liters
Refrigerant: R 404A
For your safety as the buyer, please note the following information!
The following items are carried out on all chambers offered by us:
1. Functional inspection and replacement of necessary components
2. If needed, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see photo)
(Technical data and information subject to change and errors excepted!)
We are happy to answer further questions by telephone.
Listing
Borken
785 km
Climate test chamber with humidity
VötschVC³ 0100 0°C bis + 90°C
Call
Condition: excellent (used), Vötsch
Type: VC³ 0100
Vötsch Climate Test Chamber, Air-Cooled
Internal Test Chamber Dimensions: Height 950 mm x Width 1100 mm x Depth 950 mm
Overall Device Dimensions: Height 2000 mm x Width 1300 mm x Depth 1916 mm
Test Chamber Volume: 990 litres
Temperature Testing:
Minimum Temperature: -0°C
Maximum Temperature: +90°C
Temperature Change Rate, Cooling: 0.2 K/min
Temperature Change Rate, Heating: 0.5 K/min
Temporal Temperature Deviation: ±0.1 to ±0.5 K
Spatial Temperature Uniformity: ±0.5 to ±1.0 K
Heat Compensation at +20 °C: 350 W
Climatic Testing:
Minimum Temperature: +10°C
Maximum Temperature: +90°C
Dew Point Temperature Range: +4°C to +89.5°C
Humidity Range: 10 to 98% r.h.
Temporal Humidity Deviation: ±1 to ±3% r.h.
Temporal Temperature Deviation: ±0.1 to ±0.3 K
Spatial Temperature Uniformity: ±0.5 to ±1.0 K
Nsdpsygut Refx Adtecr
Voltage: 1/N/PE AC 230V ±10% 50Hz
Rated Power: 2.3 kW
Rated Current: 10 A
Refrigerant: R-404A
Weight: approx. 1400 kg
Important information for you as a buyer:
The following measures are carried out on our offered chambers prior to delivery:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certification
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Specifications and technical details are subject to change and error!)
For further questions, we are happy to assist you by phone.
Listing
Borken
785 km
Climate test chamber with humidity
VötschVC³ 4100 990 Liter -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Vötsch climatic test chamber.
Model: VC³ 4100, air-cooled
With a temperature change rate of 3 K/min
Test chamber internal dimensions: Height 950 mm x Width 1100 mm x Depth 950 mm
Overall unit dimensions: Height 2000 mm x Width 1300 mm x Depth 1916 mm
Chamber volume: 990 liters
Port openings: Ø 125 mm, Ø 50 mm
Temperature test specifications:
Temperature range: -42°C to +180°C
Temporal temperature deviation: ± 0.1 to ± 0.5 K
Spatial temperature uniformity: ± 0.5 to ± 1.5 K
Temperature change rate:
Heating: 4.0 K/min
Cooling: 3.0 K/min
Max. heat compensation at +20°C: 4500 watts
Climatic test specifications:
Temperature range: +10°C to +95°C
Dew point range: -3°C to +94°C
Humidity range: 10 to 98% r.h.
Temporal temperature deviation: ± 0.1 to ± 0.3 K
Spatial temperature uniformity: ± 0.5 to ± 1.0 K
Temporal humidity deviation: ± 1% to ± 3% r.h.
Max. heat compensation: 500 W
Power supply: 3/N/PE AC 400V ±10% 50Hz
Rated power: 11.5 kW
Rated current: 22.0 A
Refrigerant: R-404A
Ncodpfsygutwsx Adtor
Weight: approx. 840 kg
Type: VC³ 4100
For your security as a buyer, please note the following information!
The following points are checked and carried out on all our chambers prior to sale:
1. Functional inspection and replacement of necessary components
2. If needed, fresh filling with legally compliant refrigerant
3. Leak check with certificate
4. After a successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See photo)
(Subject to prior sale, changes and errors in technical data and specifications reserved!)
We are happy to answer any further questions by phone.
Listing
Borken
785 km
Climate test chamber 335 liters with humidity
VötschVCS 7034-5 -70°C bis +180°C
Call
Condition: good (used), Type: VCS 7034-5
Climatic Test Chamber, Water-cooled
Vötsch VCS 7034-5
Test Volume: 335 liters
Specifications for Temperature Testing:
Temperature range: -70 to +180°C
Time-based temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4 K
Change rate:
Cooling: 6.7 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3000 W / at -20°C: 3000 W
Temperature calibration points: +23°C and +80°C
Specifications for Climate Testing:
Temperature range: +10 to +95°C
Time-based temperature deviation: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Time-based humidity deviation: ±1 to ±3%
Njdjygur Tspfx Adtscr
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climate calibration points: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10 kW
Rated current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerants: R452A / R-23
Important safety information for buyers:
The following procedures are carried out on our offered chambers prior to sale:
1. Functional inspection and replacement of necessary components
2. Recharging with legally compliant refrigerant, if required
3. Leak test with certificate
4. After successful testing, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Subject to technical modifications and errors. All information is non-binding!)
For further questions, please do not hesitate to contact us by phone.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
777 km
Temperature test chamber
VötschVTR 7033/S
Call
Condition: good (used), Year of construction: 1996, Vötsch VTR 7033/S Temperature test chamber
Manufacturer: Vötsch
Type: VTR 7033/S
Item no.: 60885637
Temperature chamber
Ncodpfewbpzmsx Adtor
Temp. range: -70°C to +180°C
Mains voltage:400V
Rated current:24A
Rated output: 9.5 kW
Refrigerant VK: R 404 A
Refrigerant TK: R 23
Year of manufacture: 1996
TK 07
Financing through our bank is also possible.
komplett-konzept.leasingo.de
You will find further articles - new and used - in our store!
International shipping costs on request!
Listing
Borken
777 km
Temperature shock test chamber
VötschVT 7030 S2
Call
Condition: good (used), Year of construction: 1998, Vötsch VT 7030 S2 Temperature Shock Test Chamber -80 °C to +220 °C
The Vötsch VT 7030 S2 Environmental Test Chamber is designed for laboratory applications that require testing of materials and components in a known environment. With its versatile capabilities and easy-to-use controls, this programmable unit can be used to simulate a variety of environmental conditions for scientific studies, product testing and process control.
Data for temperature tests in single chamber operation
Hot chamber:
Temperature shock test chamber Test chamber 300 l
Temperature range +50 °C to +220 °C
Ncedswbdv Sspfx Adtsr
Temperature deviation in time in the center of the chamber ± 1 K
Temperature deviation in space ± 2 K
Temperature gradient (according to IEC 60068-3-5) 4 K
Rate of temperature change (according to IEC 60068-3-5, measured in supply air)
Heating 11 K/min
Cold chamber:
Temperature shock test chamber Test chamber 300 l
Temperature range -80 °C to +70 °C
Temperature deviation in time in the middle of the usable space ± 1 K
Temperature deviation in space 2 K
Temperature gradient (according to IEC 60068-3-5) 4 K
Rate of temperature change (according to IEC 60068-3-5, measured in supply air)
Heating 1.5 K/min
Cooling 4K/min
Technical data:
Temperature shock test chamber
Test chamber volume approx. 300 l
Voltage: 3/N/PE AC 400 V ± 10 % , 50 Hz
Rated power: 30 kW
Rated power: 50 A
Refrigerant: R-404a /R-23
Chiller: Water-cooled
Weight: approx. 940 kg
Year of construction. 1998
Test room dimensions: Width 770 mm x depth 650 mm x height 610 mm
Housing dimensions: Width 1200 mm x depth 1800 mm x height 2050 mm
TS 05
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Further items - new and used - can be found in our store!
International shipping costs on request!
Listing
Borken
777 km
Temperature test chamber
VötschVT 7100
Call
Condition: excellent (used), Heraeus Vötsch VT 7100 Temperature test chamber -70°C to +180°C
Heraeus Vötsch
Temperature test chamber
VT 7100
-70°C to +180°C
1035 liters
Financing through our bank is also possible.
Ncsdpfjph Uzxox Adtsr
komplett-konzept.leasingo.de
Further articles - new and used - you will find in our store!
International shipping costs on request!
Listing
Borken
777 km
Temperature test chamber Climate test
VötschVTR 7033/S
Call
Year of construction: 1998, condition: good (used), Vötsch VTR 7033/S Temperature Test Chamber
Manufacturer: Vötsch
Type: VTR 7033/S
Nedpfjuuin Rsx Adtecr
Item No.: 60885637
Temperature Chamber
Temp. Range: -70°C to +180°C
Line Voltage: 400V
Rated Current: 24A
Rated Power: 9.5 kW
Refrigerant (VK): R 404 A
Refrigerant (TK): R 23
Year of Manufacture: 1998
TK 09
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs upon request!
We make it easier for you to find: "vötsch vcl 4003"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
This may be of interest to you