WSM stationary screwdriving unit, screwdriving station, automatic station, assembly stationWSM Automation
Schraubstation
WSM stationary screwdriving unit, screwdriving station, automatic station, assembly station
WSM Automation
Schraubstation
ONO plus VAT
€4,873
Condition
Used
Location
Borken 

Basic data
- Machine type:
- WSM stationary screwdriving unit, screwdriving station, automatic station, assembly station
- Manufacturer:
- WSM Automation
- Model:
- Schraubstation
- Condition:
- used
Price & Location
ONO plus VAT
€4,873
- Location:
- Dunkerstrasse 29, 46325 Borken/Burlo, Deutschland

Call
Details about the offer
- Listing ID:
- A7380038
- Reference number:
- 25069
- Update:
- 13.11.2026
Description
WSM Stationary Screwing Unit, Screwing Station
Assembly of parts for car radios and navigation systems, as well as testing of these parts.
The assembly station is surrounded by a protective enclosure.
The service doors are equipped with monitoring switches with a holding (locking) function.
In automatic operation, the doors are locked and can only be opened when the automatic cycle is stopped or in manual mode after pressing the "Doors" button on the control panel. The automatic cycle cannot be started with the door open.
Functional sequence:
The station is supplied with the pre-assembled unit via the conveyor belt.
The following describes the work steps of the automatic station with a single unit passing through.
In normal operation, all 3 stations work in parallel.
Ibodoibichspfx Aaisd
- Positioning the unit with the pre-assembled unit in station 2.1
- Lowering the carrier with the scanner and vision sensor
- Scanning the 3 codes (front panel, front PCB, SD PCB), comparing with the database
- Checking the correct locking of the FFC in the connector
- Raising the carrier and lowering the unit onto the belt
- Positioning the unit with the pre-assembled unit in station 2.2
- Positioning the screwdriver and screwing in the front PCB
- Lowering the unit onto the belt
- Positioning the unit with the pre-assembled unit in station 2.3
- Lowering the light protection cover and establishing contact, positioning the carrier with the test sensors from below
- Type-dependent testing of the lighting of the SD and CD slots and buttons
- Function test of the CD eject button
- Lowering the unit onto the belt > continue
If errors occur during the test, they are displayed on the screen and can be corrected if possible.
To do this, switch to manual mode and open the doors. After the repair and starting the automatic cycle, the unit is tested again in the station.
If no repair is possible (e.g. screwing error), the unit is marked as NIO (Not In Order) in the control system and is not processed further.
A manual NIO marking and removal is also possible.
More assembly stations, new and used – find them in our shop! International shipping costs available upon request!
The listing was translated automatically. Translation errors are possible.
Assembly of parts for car radios and navigation systems, as well as testing of these parts.
The assembly station is surrounded by a protective enclosure.
The service doors are equipped with monitoring switches with a holding (locking) function.
In automatic operation, the doors are locked and can only be opened when the automatic cycle is stopped or in manual mode after pressing the "Doors" button on the control panel. The automatic cycle cannot be started with the door open.
Functional sequence:
The station is supplied with the pre-assembled unit via the conveyor belt.
The following describes the work steps of the automatic station with a single unit passing through.
In normal operation, all 3 stations work in parallel.
Ibodoibichspfx Aaisd
- Positioning the unit with the pre-assembled unit in station 2.1
- Lowering the carrier with the scanner and vision sensor
- Scanning the 3 codes (front panel, front PCB, SD PCB), comparing with the database
- Checking the correct locking of the FFC in the connector
- Raising the carrier and lowering the unit onto the belt
- Positioning the unit with the pre-assembled unit in station 2.2
- Positioning the screwdriver and screwing in the front PCB
- Lowering the unit onto the belt
- Positioning the unit with the pre-assembled unit in station 2.3
- Lowering the light protection cover and establishing contact, positioning the carrier with the test sensors from below
- Type-dependent testing of the lighting of the SD and CD slots and buttons
- Function test of the CD eject button
- Lowering the unit onto the belt > continue
If errors occur during the test, they are displayed on the screen and can be corrected if possible.
To do this, switch to manual mode and open the doors. After the repair and starting the automatic cycle, the unit is tested again in the station.
If no repair is possible (e.g. screwing error), the unit is marked as NIO (Not In Order) in the control system and is not processed further.
A manual NIO marking and removal is also possible.
More assembly stations, new and used – find them in our shop! International shipping costs available upon request!
The listing was translated automatically. Translation errors are possible.
Seller
Note: Register for free or log in, to access all information.
Last online: A week ago
Registered since: 2008
530 listings online
Send inquiry
Telephone & Fax
+49 2862 ... show
These listings may also fit your interest.
Success:
Your message has been sent.
Listing
Wiefelstede
785 km
Simatic Multi Panel Touch
Siemens6AV6 644-0AA01-2AX0
Siemens6AV6 644-0AA01-2AX0
Success:
Your message has been sent.
Listing
Borken
777 km
Epson G10-854SR 4-axis SCARA industrial robot with RC180 controller
EpsonG10-854SR
EpsonG10-854SR
Success:
Your message has been sent.
Listing
Borken
784 km
Bosch Turbo Scara SR8 Robot Industrial Robot Handling Robot + IQ200 Controller
BoschTurbo Scara SR 8
BoschTurbo Scara SR 8
Success:
Your message has been sent.
Listing
Altenglan
981 km
22-inch touchscreen
SiemensSIMATIC IFP2200
SiemensSIMATIC IFP2200
Success:
Your message has been sent.
Listing
Altenglan
981 km
SIMATIC Panel PC
Siemens6AV7881-3AF00-3DT0
Siemens6AV7881-3AF00-3DT0
Success:
Your message has been sent.
Listing
Trittau
913 km
Assembly Station
PROZAPEK0 Assembly line station
PROZAPEK0 Assembly line station
Success:
Your message has been sent.
Listing
Wiefelstede
785 km
Operator Panel OP20/240-8
Siemens6AV6 542-0BB15-2AX0
Siemens6AV6 542-0BB15-2AX0
Success:
Your message has been sent.
Listing
Altenglan
981 km
Control panel
Siemens6AV6542-0BB15-2AX0
Siemens6AV6542-0BB15-2AX0
Success:
Your message has been sent.
Listing
Wiefelstede
785 km
Simatic Panel Touch
Siemens6AV6 642-0DC0-1AX1
Siemens6AV6 642-0DC0-1AX1
Your listing has been deleted successfully
An error has occurred































































































