*TECHNICAL SPECIFICATION:
Heating capacity: up to 54 kW
Cooling capacity: up to 300 kW
medium: water up to 200°C
Max. external volume: 43 ltr at 200°C
max. Flow rate: max. 230 l/min
max. delivery pressure: up to 8.3 bar
Motor power: up to 3 kW
Dimensions LxWxH: 1,460 x 525 x 1,200 mm
Weight approx. 330kg
Circulation medium connection: flange DN40 (DIN EN 1092-1), form B1
*HIGHLIGHTS EQUIPMENT:
-Control and regulation Smart Controller (7" touch display)
-Heating control via solid-state relay
-Control box IP54, externally ventilated
Nledpfxjg Ey T Ej Afwsf
-Expansion tank, heater and piping stainless steel
-Heating via stainless steel tubular heating elements made of Incolloy
-Dirt trap (circulation)
-Unit ready for connection and mounted on castors, 2 of them steerable and with brake
-Cooling and filling controlled by solenoid valve
-configurable automatic filling via KW inflow or separate connection (factory-supplied via cooling water inflow)
-flow measurement by differential pressure principle
-Level monitoring by magnetic float switch
-automatic temperature-dependent system closure (not with WP7-90)
-flow monitoring by recording the flow rate
-Bypass between flow and return with reduced cross-section
-dirty filter in the cooling water inflow, filling and return of the circulation system
-Continuous bypass of the heat exchanger via 3-way motorised control valve (WP7-180/200)
-System pressure monitoring via pressure transmitter in the AD tank (WP7-150/180/200)
-Pressure booster pump for system filling (WP7-180/200, otherwise optional)
-Safety temperature limiter (STB) in the heater and flow (WP7-200)
-Pressure gauge in the supply line on the back of the unit
-heat-insulated circulation circuit (WP7-150/180/200)
Visit our website for more details or for other performance classes.
*This unit is compliant with the European Directives. Other directives and standards are only fulfilled if they are listed in the order confirmation. This technical specification reflects the standard equipment, customer requests deviating from the standard will be shown in quotations or order confirmations.
Heating capacity: up to 54 kW
Cooling capacity: up to 300 kW
medium: water up to 200°C
Max. external volume: 43 ltr at 200°C
max. Flow rate: max. 230 l/min
max. delivery pressure: up to 8.3 bar
Motor power: up to 3 kW
Dimensions LxWxH: 1,460 x 525 x 1,200 mm
Weight approx. 330kg
Circulation medium connection: flange DN40 (DIN EN 1092-1), form B1
*HIGHLIGHTS EQUIPMENT:
-Control and regulation Smart Controller (7" touch display)
-Heating control via solid-state relay
-Control box IP54, externally ventilated
Nledpfxjg Ey T Ej Afwsf
-Expansion tank, heater and piping stainless steel
-Heating via stainless steel tubular heating elements made of Incolloy
-Dirt trap (circulation)
-Unit ready for connection and mounted on castors, 2 of them steerable and with brake
-Cooling and filling controlled by solenoid valve
-configurable automatic filling via KW inflow or separate connection (factory-supplied via cooling water inflow)
-flow measurement by differential pressure principle
-Level monitoring by magnetic float switch
-automatic temperature-dependent system closure (not with WP7-90)
-flow monitoring by recording the flow rate
-Bypass between flow and return with reduced cross-section
-dirty filter in the cooling water inflow, filling and return of the circulation system
-Continuous bypass of the heat exchanger via 3-way motorised control valve (WP7-180/200)
-System pressure monitoring via pressure transmitter in the AD tank (WP7-150/180/200)
-Pressure booster pump for system filling (WP7-180/200, otherwise optional)
-Safety temperature limiter (STB) in the heater and flow (WP7-200)
-Pressure gauge in the supply line on the back of the unit
-heat-insulated circulation circuit (WP7-150/180/200)
Visit our website for more details or for other performance classes.
*This unit is compliant with the European Directives. Other directives and standards are only fulfilled if they are listed in the order confirmation. This technical specification reflects the standard equipment, customer requests deviating from the standard will be shown in quotations or order confirmations.
Seller
Note: Register for free or log in, to access all information.
Registered since: 2020
8 listings online
Send inquiry
Telephone & Fax
+49 7153 ... show
These listings may also fit your interest.
Listing
Wrocław
1,434 km
Injection molding machine
KraussMaffeiKM 850-12000 MX
KraussMaffeiKM 850-12000 MX
Listing
Dordrecht
667 km
Steering wheel
AJCEAVH30 Sheet Pile Vibro Hammer Pile Driver
AJCEAVH30 Sheet Pile Vibro Hammer Pile Driver
Listing
Saarbrücken
980 km
Hexagon Optiv M 6.6.4 DUAL Z CMM
HexagonM 6.6.4 Dual Z
HexagonM 6.6.4 Dual Z
Listing
Hamburg
895 km
Multihead weigher
ISY PACK GmbHWT10-2500
ISY PACK GmbHWT10-2500
Listing
Hochdorf
1,153 km
Temperature Cooling Unit (TCU)
SingleCompact WK3-160-9-50 (IM160F)
SingleCompact WK3-160-9-50 (IM160F)
Listing
Aach
1,192 km
Machining center
MIKRONVCP 800 W
MIKRONVCP 800 W
Listing
Berlin
1,143 km
Vertical Injection Moulding Machine
ENGELe-insert 740H/60 single-C
ENGELe-insert 740H/60 single-C
Listing
Germany
950 km
Deep hole drilling machine / Retrofit 2023
IXION AUERBACHIA2 TLF-1200.4
IXION AUERBACHIA2 TLF-1200.4
Listing
Fluorn-Winzeln
1,135 km
Start hole eroding machine
bes Erodiermaschinen GmbHSLPR 630 CNC VHM Ölmaschine
bes Erodiermaschinen GmbHSLPR 630 CNC VHM Ölmaschine
Listing
Trenčianske Stankovce
1,627 km
KM 1600 – 17200 MX
KraussMaffeiKM 1600 – 17200 MX
KraussMaffeiKM 1600 – 17200 MX
Your listing has been deleted successfully
An error has occurred