S/S LAGARDE STATIC AUTOCLAVE 4 BLagarde
S/S LAGARDE STATIC AUTOCLAVE 4 B
Lagarde
Condition
Used
Location
Lorquí 

Show images
Show map
Machine data
Price & Location
- Location:
- Polígono Industrial de Lorquí Parcela 129, 30564 Lorquí, España

Call
Details about the offer
- Listing ID:
- A20900242
- Update:
- 09.01.2026
Description
Autoclaves are used for the sterilization of packaged products that need to reach high temperatures (+100ºC) for the elimination or inactivation of pathogenic microorganisms.
Fsdpfex S Ipwjx Aa Eefw
Static autoclaves: these are suitable for any format and are used for food packaged in cans, jars and other flexible materials.
CHARACTERISTICS:
* Forced ventilation
*Shower system.
* Temperature and time recorder.
CONSUMPTIONS:
- Steam: Maximum flow rate 2100 kg/h. Approximate consumption 475 kg/cycle.
- Electrical energy in KW: 22kw
- Cold water in tn/hr: Flow rate 25m³/h.
- Compressed air in m³/min. The theoretical required to cool the autoclave in the worst air requirement condition (empty or with low load) is 2.91 m³/minute.
- Total amount of drainage in ton/day: Depends on the number of cycles. Approximately 0.8 m3/cycle will be drained from inside the autoclave at the end of the cycle. The water output of the exchanger will be the same as the water input during cooling, 25 m³/h.
- Total raw water consumption in tn/day: 0.8 m³/cycle final + 12-16 m³ cooling.
The listing was translated automatically. Translation errors are possible.
Fsdpfex S Ipwjx Aa Eefw
Static autoclaves: these are suitable for any format and are used for food packaged in cans, jars and other flexible materials.
CHARACTERISTICS:
* Forced ventilation
*Shower system.
* Temperature and time recorder.
CONSUMPTIONS:
- Steam: Maximum flow rate 2100 kg/h. Approximate consumption 475 kg/cycle.
- Electrical energy in KW: 22kw
- Cold water in tn/hr: Flow rate 25m³/h.
- Compressed air in m³/min. The theoretical required to cool the autoclave in the worst air requirement condition (empty or with low load) is 2.91 m³/minute.
- Total amount of drainage in ton/day: Depends on the number of cycles. Approximately 0.8 m3/cycle will be drained from inside the autoclave at the end of the cycle. The water output of the exchanger will be the same as the water input during cooling, 25 m³/h.
- Total raw water consumption in tn/day: 0.8 m³/cycle final + 12-16 m³ cooling.
The listing was translated automatically. Translation errors are possible.
Documents
Seller
Note: Register for free or log in, to access all information.
Registered since: 2024
100 listings online
Send inquiry
Telephone & Fax
+34 968 6... show
These listings may also fit your interest.
Listing
Suffolk
442 km
Retort / autoclave
Lagarde4 trolley retort
Lagarde4 trolley retort
Listing
Poznań
1,369 km
Autoklav Autoclave
SteritechAV20
SteritechAV20
Listing
Mouvaux
680 km
Meat processing machine
LagardeAutoclave SVS100
LagardeAutoclave SVS100
Listing
Bury St Edmunds
442 km
Optical sorter for vegetables
Tomra OdenbergHalo III 2021
Tomra OdenbergHalo III 2021
Listing
Finland
1,791 km
Meat processing machine
Steriflow1351 EL.
Steriflow1351 EL.
Listing
Sevenum
766 km
Vacuum capper
CalumaticMTV-6
CalumaticMTV-6
Listing
Mouvaux
680 km
Autoclave
SteriflowBarriquand 1351
SteriflowBarriquand 1351
Listing
Janville
878 km
Sterilisation autoclave
Steriflow1321 EA
Steriflow1321 EA
Listing
Krotoszyn
1,434 km
Centrifuge (whey de-fatting)
Alfa Laval
Alfa Laval
Listing
Germany
1,137 km
Tank for autoclave
Gessner1CB 0206 B101
Gessner1CB 0206 B101
Your listing has been deleted successfully
An error has occurred












































































































