S/S LAGARDE STATIC AUTOCLAVE 4 BLagarde
S/S LAGARDE STATIC AUTOCLAVE 4 B
Lagarde
Condition
Used
Location
Lorquí 

Show images
Show map
Machine data
Price & Location
- Location:
- Polígono Industrial de Lorquí Parcela 129, 30564 Lorquí, España

Call
Details about the offer
- Listing ID:
- A20900242
- Update:
- 09.01.2026
Description
Autoclaves are used for the sterilization of packaged products that need to reach high temperatures (+100ºC) for the elimination or inactivation of pathogenic microorganisms.
Static autoclaves: these are suitable for any format and are used for food packaged in cans, jars and other flexible materials.
CHARACTERISTICS:
* Forced ventilation
*Shower system.
Ijdpfxjx S Ipwe Addeht
* Temperature and time recorder.
CONSUMPTIONS:
- Steam: Maximum flow rate 2100 kg/h. Approximate consumption 475 kg/cycle.
- Electrical energy in KW: 22kw
- Cold water in tn/hr: Flow rate 25m³/h.
- Compressed air in m³/min. The theoretical required to cool the autoclave in the worst air requirement condition (empty or with low load) is 2.91 m³/minute.
- Total amount of drainage in ton/day: Depends on the number of cycles. Approximately 0.8 m3/cycle will be drained from inside the autoclave at the end of the cycle. The water output of the exchanger will be the same as the water input during cooling, 25 m³/h.
- Total raw water consumption in tn/day: 0.8 m³/cycle final + 12-16 m³ cooling.
The listing was translated automatically. Translation errors are possible.
Static autoclaves: these are suitable for any format and are used for food packaged in cans, jars and other flexible materials.
CHARACTERISTICS:
* Forced ventilation
*Shower system.
Ijdpfxjx S Ipwe Addeht
* Temperature and time recorder.
CONSUMPTIONS:
- Steam: Maximum flow rate 2100 kg/h. Approximate consumption 475 kg/cycle.
- Electrical energy in KW: 22kw
- Cold water in tn/hr: Flow rate 25m³/h.
- Compressed air in m³/min. The theoretical required to cool the autoclave in the worst air requirement condition (empty or with low load) is 2.91 m³/minute.
- Total amount of drainage in ton/day: Depends on the number of cycles. Approximately 0.8 m3/cycle will be drained from inside the autoclave at the end of the cycle. The water output of the exchanger will be the same as the water input during cooling, 25 m³/h.
- Total raw water consumption in tn/day: 0.8 m³/cycle final + 12-16 m³ cooling.
The listing was translated automatically. Translation errors are possible.
Documents
Seller
Note: Register for free or log in, to access all information.
Registered since: 2024
Send inquiry
Telephone & Fax
+34 968 6... show
These listings may also fit your interest.
Listing
Ystad
1,087 km
Traysealer
MultivacT-800
MultivacT-800
Listing
Lorquí
1,931 km
FERLO STATIC AUTOCLAVE 4 BASKETS
FERLO
FERLO
Listing
Sevenum
766 km
Vacuum capper
CalumaticMTV-6
CalumaticMTV-6
Listing
Bury St Edmunds
442 km
Optical sorter for vegetables
Tomra OdenbergHalo III 2021
Tomra OdenbergHalo III 2021
Listing
Suffolk
442 km
High speed cartoner
KliklokConcorde K170
KliklokConcorde K170
Listing
Murska Sobota
1,671 km
Drying plant for fruits an vegetables
Binder Germany
Binder Germany
Listing
Bury St Edmunds
442 km
Tray sealer
MondiniEvolution 590 V/G
MondiniEvolution 590 V/G
Listing
Suffolk
442 km
2023 Ilpra skinpacker
IlpraFoodPack Speedy Duo Overskin
IlpraFoodPack Speedy Duo Overskin
Listing
Suffolk
442 km
Large continuous blancher for veg or seafood production
CabinplantContinuous blancher
CabinplantContinuous blancher
Listing
Wallern an der Trattnach
1,430 km
Conical rotary sieve
KreuzmayrKDS 550
KreuzmayrKDS 550
Your listing has been deleted successfully
An error has occurred