Climate test chamber 5,500 liters (5.5 m³)CTS
CW-60/5,5 -60°C bis +100°C
Climate test chamber 5,500 liters (5.5 m³)
CTS
CW-60/5,5 -60°C bis +100°C
Condition
Used
Location
Borken 

Show images
Show map
Machine data
Price & Location
- Location:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Call
Details about the offer
- Listing ID:
- A20699180
- Reference number:
- 24906
- Update:
- 20.01.2026
Description
CTS CW-60/5.5 – Water-cooled Climate Test Chamber
The CW-60/5.5 from CTS GmbH (Climatic Test Systems) is a medium-sized, walk-in and drive-in climatic chamber designed for simultaneous temperature and humidity testing on multiple test specimens.
Device Description
The climate test chamber allows for functionality or material property testing of a test item under the influence of temperature and humidity. Efficient air circulation with a correspondingly high level of recirculating air volume ensures excellent transfer to the test item. The air treatment compartment is located at the rear of the test chamber. The aggregates are positioned behind the unit in a separate frame for easy access. The control system is integrated into a separate control cabinet. The control panel is mounted in the door of the control cabinet. For dehumidification, the test chamber is equipped with a self-regenerating compressed air dryer. The test chamber can also be purged with fresh air via an internal blower.
Technical Specifications:
Temperature Testing:
- Temperature range: -60 °C to +100 °C
- Temperature deviation: ±0.5 to 1 K over time
- Temperature change rate, linear with specimen and heat radiation, measured in supply air:
- Heating: 2 K/min from -40 °C to +85 °C
- Cooling: 2 K/min from +85 °C to -40 °C
Climatic Testing:
- Temperature range: +10 °C to +90 °C
- Humidity range: 10% to 95% rH
- Dew point range: +5 °C to +89 °C
- Temperature deviation: ±0.5 K over time
Ncodpfxox D Abpe Ahzsl
- Humidity deviation: ±1 – ±3% rH over time
Technical data refer to an ambient temperature of +25 °C, nominal voltage 400 V, without test item, without external radiation and without additional devices.
Dimensions:
Internal dimensions (test space/usable volume):
- Volume: approx. 5,500 liters (5.5 m³)
- Internal dimensions (approx.): Height: 2,300 mm, Width: 1,600 mm, Depth: 1,550 mm
External dimensions: Height: 2,800 mm, Width: 2,250 mm, Depth: 5,000 mm
Operating Data:
- Electrical connection: 400 V +6/-10%, 3/N, PE, 50 Hz
- Nominal power: 58.3 kW (incl. 5 sockets)
- Nominal current: 86.0 A
- Protection rating: IP 54
Technical Execution:
Refrigeration unit:
Water-cooled, low noise, semi-hermetic, infinitely variable capacity adjustment via electronic monitoring and control system, environmentally friendly refrigerants R 23 / R 404 A
Notes:
Inspection by appointment possible (46325 Borken)
Shipping by forwarding agent possible – Costs & organization upon request
Scope of delivery: (see photo)
(Subject to change and possible errors in the technical data; information provided without liability!)
For further questions, we are happy to assist you via telephone.
The listing was translated automatically. Translation errors are possible.
The CW-60/5.5 from CTS GmbH (Climatic Test Systems) is a medium-sized, walk-in and drive-in climatic chamber designed for simultaneous temperature and humidity testing on multiple test specimens.
Device Description
The climate test chamber allows for functionality or material property testing of a test item under the influence of temperature and humidity. Efficient air circulation with a correspondingly high level of recirculating air volume ensures excellent transfer to the test item. The air treatment compartment is located at the rear of the test chamber. The aggregates are positioned behind the unit in a separate frame for easy access. The control system is integrated into a separate control cabinet. The control panel is mounted in the door of the control cabinet. For dehumidification, the test chamber is equipped with a self-regenerating compressed air dryer. The test chamber can also be purged with fresh air via an internal blower.
Technical Specifications:
Temperature Testing:
- Temperature range: -60 °C to +100 °C
- Temperature deviation: ±0.5 to 1 K over time
- Temperature change rate, linear with specimen and heat radiation, measured in supply air:
- Heating: 2 K/min from -40 °C to +85 °C
- Cooling: 2 K/min from +85 °C to -40 °C
Climatic Testing:
- Temperature range: +10 °C to +90 °C
- Humidity range: 10% to 95% rH
- Dew point range: +5 °C to +89 °C
- Temperature deviation: ±0.5 K over time
Ncodpfxox D Abpe Ahzsl
- Humidity deviation: ±1 – ±3% rH over time
Technical data refer to an ambient temperature of +25 °C, nominal voltage 400 V, without test item, without external radiation and without additional devices.
Dimensions:
Internal dimensions (test space/usable volume):
- Volume: approx. 5,500 liters (5.5 m³)
- Internal dimensions (approx.): Height: 2,300 mm, Width: 1,600 mm, Depth: 1,550 mm
External dimensions: Height: 2,800 mm, Width: 2,250 mm, Depth: 5,000 mm
Operating Data:
- Electrical connection: 400 V +6/-10%, 3/N, PE, 50 Hz
- Nominal power: 58.3 kW (incl. 5 sockets)
- Nominal current: 86.0 A
- Protection rating: IP 54
Technical Execution:
Refrigeration unit:
Water-cooled, low noise, semi-hermetic, infinitely variable capacity adjustment via electronic monitoring and control system, environmentally friendly refrigerants R 23 / R 404 A
Notes:
Inspection by appointment possible (46325 Borken)
Shipping by forwarding agent possible – Costs & organization upon request
Scope of delivery: (see photo)
(Subject to change and possible errors in the technical data; information provided without liability!)
For further questions, we are happy to assist you via telephone.
The listing was translated automatically. Translation errors are possible.
Seller
Note: Register for free or log in, to access all information.
Send inquiry
Telephone & Fax
+49 2861 ... show
These listings may also fit your interest.
Listing
Borken
785 km
Climate test chamber 5,500 liters (5.5 m³)
CTSCW-60/5,5 -60°C bis +100°C
CTSCW-60/5,5 -60°C bis +100°C
Listing
Deining
1,224 km
Dual-fuel burner
WEISHAUPT RGL 40/1-B // 2550kwMit Schaltschrank
WEISHAUPT RGL 40/1-B // 2550kwMit Schaltschrank
Listing
Borken
785 km
Climate test chamber 5,500 liters (5.5 m³)
CTSCW-60/5,5 -60°C bis +100°C
CTSCW-60/5,5 -60°C bis +100°C
Listing
Borken
785 km
Weathering tester
AtlasXenotest Alpha LM
AtlasXenotest Alpha LM
Listing
Euskirchen
862 km
Screw air compressor
FINIK-MAX 1510 VS (IE3)
FINIK-MAX 1510 VS (IE3)
Listing
Geffen
715 km
Chassis cab
ScaniaR500 NGS 6x2 Chassis cabine Stuur lift as
ScaniaR500 NGS 6x2 Chassis cabine Stuur lift as
Your listing has been deleted successfully
An error has occurred