HEIDEN Infeed Test System ES1.3 High-Performance DC Test Facility 500 kW / 3x400V / 1000V 800A
HEIDEN power HTS14-500-1002

Condition
Used
Location
Borken Germany
HEIDEN Infeed Test System ES1.3 High-Performance DC Test Facility 500 kW / 3x400V / 1000V 800A HEIDEN power HTS14-500-1002
HEIDEN Infeed Test System ES1.3 High-Performance DC Test Facility 500 kW / 3x400V / 1000V 800A HEIDEN power HTS14-500-1002
HEIDEN Infeed Test System ES1.3 High-Performance DC Test Facility 500 kW / 3x400V / 1000V 800A HEIDEN power HTS14-500-1002
HEIDEN Infeed Test System ES1.3 High-Performance DC Test Facility 500 kW / 3x400V / 1000V 800A HEIDEN power HTS14-500-1002
HEIDEN Infeed Test System ES1.3 High-Performance DC Test Facility 500 kW / 3x400V / 1000V 800A HEIDEN power HTS14-500-1002
HEIDEN Infeed Test System ES1.3 High-Performance DC Test Facility 500 kW / 3x400V / 1000V 800A HEIDEN power HTS14-500-1002
HEIDEN Infeed Test System ES1.3 High-Performance DC Test Facility 500 kW / 3x400V / 1000V 800A HEIDEN power HTS14-500-1002
HEIDEN Infeed Test System ES1.3 High-Performance DC Test Facility 500 kW / 3x400V / 1000V 800A HEIDEN power HTS14-500-1002
more Images
HEIDEN power HTS14-500-1002
HEIDEN power HTS14-500-1002
HEIDEN power HTS14-500-1002
HEIDEN power HTS14-500-1002
HEIDEN power HTS14-500-1002
HEIDEN power HTS14-500-1002
HEIDEN power HTS14-500-1002
HEIDEN power HTS14-500-1002

Price & Location

Location:
Borken, Germany Germany
Call

Details about the offer

Listing ID:
A23038881
Reference number:
25754
Update:
19.10.2026

Description

HEIDEN – COMPETENCE IN POWER

HEIDEN Infeed Test System ES1.3 High-performance DC test system 500 kW / 3x400V / 1000V 800A

Year of manufacture: 2015 · IGBT/PWM · HTS14 digital controller · industrial DC test system

Multi-part switchgear system for industrial testing and supply applications
with power, control, measurement and monitoring technology.

Technical data:

Manufacturer: HEIDEN
Model: Infeed Test System ES1.3
System type: 3870; Series: HTS14-500-1002
Device No.: 3870.550.01.400; Serial No.: 332732
Year of manufacture: 2015; Operation: DB (continuous operation)
Output rated power: 500 kW
Efficiency at rated load/voltage: 95 %
Power loss: 27 kW; Noise: max. 79 dB(A) @ 1 m

Input:

Mains: 3/PE/400 V AC ±10 %; 50 Hz ±6 %
Power consumption: 526 kVA; Power factor: >0.99
Maximum input current: 854 A @ 400 V
Protective fuse: 3× gL/gG 1000 A
Cable: 3×185 mm²/phase; PE: 3×95 mm²

Output / Control:

DC: 10–1000 V adjustable; ±800 A, adjustable current limit
Rated power: 500 kW; Cable per pole: 3×150 mm²
Measurement accuracy/-resolution U/I: 0.1 % fs / 16 Bit ADC each
Control accuracy U/I: 0.1 % fs each
Static setpoint tolerance U: approx. max. ±0.1 % fs; I: max. ±0.1 % fs
Residual ripple U (ohmic load)/I: 0.1 % fs eff. each
Current rise time 10–90 % Iₙ: typ. ;2 ms (standard conditions)

Power / Control:

HEIDEN HTS14, LCD; Transistor rectifier, PWM, galvanically isolated; IGBT technology
IGBT power components: 3×1000 V DC (bill of materials ES1.3)
Digital IGBT controller/fast DC controller
Storage chokes: 3×1200 µH; thermally 270 A; saturation 400 A
DC contactors: 4× single-pole, coil 24 V; Filter charging unit
Cooling: forced air

Measurement / Safety:

LCD panel; Analog display 0–1000 V DC
Current transformers and shunts: 600 A/60 mV, class 0.5
Isometer IRDH275B-435; AGH150W up to 1100 V DC
Mushroom head PNOZmulti 2 with extensions (bill of materials)
Protection class 1 (EN 60950); IP20 (EN 60529)
Protective conductor current: ;5 % Iₙ, typ. 50 mA

Communication / Features:

CAN, Ethernet; CANopen (safety control)
Remote indicator relays; Control power supply 24 V DC/10 A (bill of materials)
Metal cabinets with ventilation; Operating, power, and control electronics
HTS14-LCD, Analog display, Control elements
Cable entry at the bottom; Door hinge on the right (standard)

Dimensions / Weights:

W×D×H: (1400+1200+1200)×1000×2000 mm
ES1.1: 1900 kg; ES1.2: 650 kg; ES1.3: 1050 kg
Total: approx. 3600 kg; RAL 7035
Wall distance min. 200 mm; Ceiling min. 300 mm

Operating conditions:

0 to +40 °C; RH 5–85 % without condensation
With cabinet heating up to 95 % RH without condensation
Installation height max. 1000 m above sea level at rated load; Air pressure min. 870 hPa
Restricted access; non-flammable base (e.g. concrete)
Pollution degree 2

Notes:

System data type 3870; Components/quantities according to the bill of materials. 500 kW applies to the entire system.
1000 V and 800 A are not confirmed to be available simultaneously. Cable cross-sections
apply to the documented installation conditions.

Scope of supply:

1× HEIDEN Infeed Test System with HTS14 and existing cabinet/power components as shown in the pictures.

Lsdpfx Aoz Uc Sbob Nsah
Tools, machines and items not explicitly mentioned are not part of the sale.

The listing was translated automatically. Translation errors are possible.

Seller

Registered since: 2012

613 listings online

Trustseal icon
Call

Send inquiry

Countryus 
Germany
Austria
Switzerland
United States
United Kingdom
France
Belgium
Spain
Mexico
Italy
Netherlands
Poland
Russian Federation
Belarus
Ukraine
Estonia
Turkey
New Zealand
Ireland
Czech Republic
Denmark
Finland
Sweden
Norway
Luxembourg
Greece
Lithuania
Latvia
Iceland
Portugal
Brazil
Venezuela
Argentina
Hungary
Slovakia
Romania
Moldova
Slovenia
Serbia
Montenegro
Albania
Croatia
Bulgaria
Macedonia
Bosnia and Herzegovina
Israel
Egypt
Morocco
India
Indonesia
South Korea
Japan
Thailand
Malaysia
Vietnam
China (People's Republic of China)
Taiwan
Iran
Bangladesh
Note: Your inquiry will be forwarded to all sellers in this machine category. This allows you to receive a large number of offers.
The inquiry could not be sent. Please try again later.

Telephone & Fax

+49 2861 ... show