Used Climate Chamber for sale (5,990)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
785 km
Climate test chamber -45°C to +90°C approx. 6 m³
Weiss TechnikWK 6'/45-90 Begehbare
Call
Year of construction: 2014, condition: excellent (used), Weiss Technik WK 6'/45-90 Walk-in Climate Test Chamber
Manufacturer: Weiss Umwelttechnik GmbH
Type: WK 6'/45-90
Year of Manufacture: 2014
Machine Type: Walk-in Temperature and Climate Test Chamber
Refrigeration System: Water-cooled
Test Chamber Volume: approx. 6 m³
Weight: approx. 3,560 kg
For sale is a used walk-in climate test chamber from Weiss Umwelttechnik GmbH.
The system is suitable for temperature and climate testing, environmental simulation, material testing, quality assurance,
as well as development and long-term testing of large test specimens.
Technical Data
Temperature Range: -45 °C to +90 °C
Temperature Change (Heating): approx. 1.8 K/min
Temperature Change (Cooling): approx. 1.8 K/min
Temperature Deviation: ±0.3 to ±1.0 K
Climate Range: +20 °C to +90 °C
Humidity Range: 15 to 95 % RH
Dew Point Range: +4 °C to +81 °C
Humidity Deviation: ±5 % RH
Thermal Load (Heating): 3,200 W
Thermal Load (Cooling): 3,200 W
Dimensions
Test Chamber Dimensions: approx. 1,500 × 2,600 × 1,500 mm (W × D × H)
Housing Dimensions: approx. 2,010 × 5,100 × 2,200 mm (W × D × H)
Refrigeration System
Type: Water-cooled
Refrigerant 1: R452A, 17.0 kg
Refrigerant 2: R23, 8.4 kg
Cooling Water Connection: R 1½"
Cooling Water Pressure: 2 to 6 bar
Cooling Water Inlet: +12 °C
Cooling Water Outlet: +18 °C
Max. Cooling Water Consumption: 15 m³/h
Electrical Data
Mains Connection: 3/N/PE AC 400 V ±10 % / 50 Hz
Rated Power: 70.2 kW
Rated Current: 117 A
Protection Class: IP54
Noise Level: approx. 70 dB(A)
Max. Heat Dissipation: approx. 4.5 kW
Rjdpfx Abszibd Togow
Load Capacity
Floor Load Capacity: 30,000 N/m² (approx. 3,000 kg/m²)
Permissible Wheel Load: 1,000 N per wheel (4 cm² contact area)
Equipment
SIMPAC control system
Touch panel operation
Walk-in stainless steel test chamber
Temperature and humidity control
Water-cooled cooling system
4 × 50 W test chamber lighting
Emergency opening from the inside
Test chamber door with safety lock
Cable glands
Documentation / Operating manual
Electrical diagrams available
Application Areas
Temperature testing
Climate testing
Environmental simulation
Material testing
Automotive
Battery testing
Electronics testing
Quality assurance
Research and development
Condition
Used
Optical condition as shown in the pictures.
Scope of Delivery
Weiss Technik WK 6'/45-90 Climate Test Chamber
Documentation / Operating manual
Electrical diagrams
Accessories as shown in the pictures
Scope of delivery as pictured.
Subject to changes, errors and prior sale.
Listing
Borken
785 km
Climate test chamber with humidity, 190 liters
VötschVC 7018 -70 bis 180°C
Call
Condition: excellent (used), Vötsch
Type: VC 7018
Vötsch Climatic Test Chamber VC 7018 Water-Cooled
Touch Panel Control Unit
Rjdpfjzh Huhex Abgsw
On the touch panel control unit, all control and operating commands can be triggered by simply touching the function symbols.
Adjustable Feet
To compensate for uneven floors and ensure adequate ventilation of the machine section,
the test chamber is equipped with adjustable feet.
Ports
The test chamber is equipped with port holes on the right and left sides.
These allow measurement cables and test equipment to be routed into the test chamber.
Feedthrough included in standard equipment
R1: NW 125 mm
L1: NW 50 mm
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1280 mm x Height 1745 mm
Characteristics for temperature tests:
Temperature range: -70°C to +180°C
Temperature ±0.1 to ±0.5 K
Spatial ±0.5 to ±2.0 K
Temperature change rate according to IEC 60068-3-5
Heating: 4 K/min
Cooling: 2.3 K/min
Characteristics for climatic tests:
Temperature range: -10°C to +95°C
Humidity range: 10% to 98% r.h. F.
Temperature deviation over time in the center of the usable space ± 0.1 to ± 0.3 K
Temperature deviation over space ± 0.5 to ± 1.0 K
Temperature gradient 1 to 2 K
Humidity deviation over time in the center of the usable space ± 1 to ± 3 %RH
Electrical connection:
Nominal voltage: 3/N/PE AC 400V ±10 50Hz
Nominal power: 5.9 kW
Nominal current: 12.0 A
Connection cable: 3.5 m
Fuse protection: 16 A slow-blow, provided by the customer
Refrigerants: R-404A and R-23
Test chamber capacity: approx. 190 liters
Weight: approx. 460 kg net
For your safety, the following information is provided as a buyer!
The following steps are performed on our offered chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
785 km
Climatic chamber -75°C / +180°C with humidity control
TIRATCC 7120
Call
Condition: excellent (used), TIRA
Type: TCC 7120
Temperature range: -75°C / +180°C
Air-cooled condenser
Temperature stability (over time and in the center of the usable space): ±0.1°C ... ±0.3°C
Maximum temperature change rate:
Rjdpfxszh Htqo Abgow
Heating: 4°C/min
Cooling: 3°C/min
Humidity range: 10% to 98% relative humidity
Humidity stability over time: ±1% to ±3%
Dew point range during long-term tests: +2 / +94 °C
Dew point range during short-term tests: -20 / +2 °C
External dimensions (L x W x H): 1320 x 2235 x 2137 mm
Test chamber dimensions (L x W x H): 1000 x 1130 x 1020 mm
Test chamber volume: approx. 1152 liters
Max. load per shelf: 50 kg
Maximum floor load of the test chamber: 100 kg
Refrigerant: R404A and R23
Power supply: 400V + 6%/-10% / 50Hz / 3P+N+PE
Rated power: 10.2 max. 17.5 kW
Rated current: 19.5 max. 32.0 A
Noise level: approx. 80 dB(A)
Weight: 1180 kg
For your security as a buyer, please note the following:
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will be subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and specifications are subject to change!)
We will gladly answer any further questions you may have by phone.

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing
Borken
785 km
Climate test chamber temp. -70 to 180°C
Weiss explosionsgeschütztWK-600/70 (I)-(II) 2 G EEx
Call
Condition: excellent (used), Weiss
Type: WK-600/70 (I)-(II) 2 G EEx /22605147
Weiss Climate Chamber, Water-Cooled
(Test chamber, explosion-proof)
INERTIZATION WITH NITROGEN / EXPLOSION-PROOF TEST CHAMBER
Technical Data:
Test chamber designation: WK-600/70 (I)-(II) 2 G EEx
External dimensions with hinges and door lock:
Height 1995 mm, Width 1090 mm, Depth 1660 mm
External dimensions without hinges and door lock:
Height 1995 mm, Width 1000 mm, Depth 1660 mm
Test chamber volume: approx. 600 liters
Cold/Heat operation: -70 to 180°C
Climate operation: 10 – 95°C
Humidity: 10...98 % RH
Temperature change per unit of time:
Cooling: approx. 2.5 K/min
Heating: approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 14 kW
Rated current: 25 A
Fuse (on customer's side): 32 A, slow-blow
Permissible weight of test specimens:
Total load of the shelf supports: 80 kg
Test chamber floor: 80 kg, insert shelf: 40 kg
Weight: 800 kg
Refrigerant: R 404A/R 23
(Evaporator of the air conditioning system has been replaced)
For your safety as a buyer, please note the following information!
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
Rjdpfxszh D Rye Abgew
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by phone.
Listing
Borken
785 km
Climate chamber 138 liters
CLIMATSEXCAL 1413-HA -40 bis 180°C
Call
Condition: excellent (used), Climate chambers
Type: EXCAL 1413-HA
Air-cooled climate chamber
EXCAL is equipped with a 15-inch capacitive multi-touch panel PC, SSD storage, Windows 7, and 2 USB ports.
This makes it state-of-the-art.
Technical data:
Test chamber dimensions: Width 550 mm x Depth 500 mm x Height 500 mm
Housing dimensions: Width 820 mm x Depth 1375 mm x Height 1730 mm
Window 350 x 380
Volume: 138 liters
Feedthrough installed as standard
R1: 80 mm ∅
L1: 80 mm ∅
Data for temperature tests:
Temperature range: -40°C to +180°C
Temperature deviation over time ± 0.1 to ± 0.3 K
Temperature homogeneity spatially ± 0.5 to ± 1.8 K
Temperature change rate
Heating: 15 K/min
Cooling: 10 K/min
Data for climate tests:
Temperature range +10 to +90 °C
Humidity range 10 to 98 % RH
Data for operation:
3/N/Ph+T 400V ±10% 50 Hz
Rated power 9.8 kVA
Refrigerant R-404A / R-23
Weight: 430 kg
For your peace of mind as a buyer, please note the following:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Rsdpfxezh D Rtj Abgjw
Scope of delivery: (See picture)
(Changes and errors in the technical data and information are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Discover more used machines
Listing
Borken
785 km
Climatic test chamber -70°C to +180°C
VötschVCS 7034-5 - 335 Liter
Call
Condition: used, Vötsch
Type: VCS 7034-5
Water-cooled climate test chamber
Test chamber volume: 335 liters
Performance for temperature tests:
Temperature range: -70 to +180°C
Time-related temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4
Rate of change:
Cooling: 6.7 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3000 W / at -20°C: 3000 W
Temperature calibration values: +23°C and +80°C
Performance for climate tests:
Temperature range: +10 to +95°C
Time-related temperature deviation: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Time-related humidity deviation: ±1 to ±3%
Dew point range: -3 to +94°C
Rodpfezg Tx Rox Abgew
Heat compensation: 400 W
Climate calibration values: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions: Width 580mm, Depth 765mm, Height 750mm
External dimensions: Width 870mm, Depth 1595mm, Height 1775mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10kW
Rated current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerant: R-404A / R-23
For your security as a buyer, please note the following:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions by telephone.
Listing
Borken
785 km
Climatic chamber
WEISSWK 50 /40-120
Call
Condition: good (used), Weiss
Type: Walk-in Climate Simulation Chamber WK 50 / 40-120
Technical specifications of the climate chamber:
Temperature range: -40...+120 °C
Temperature tolerance: +/- 0.5°C
Temperature change rate: 1 K/min
Humidity range: 15...approx. 95 % RH
Humidity tolerance: +/- 5.0 % RH
Dimensions:
Test space volume: 50 m³
External dimensions (W x D x H): approx. 4800 mm x 6100 mm x 2640 mm
Redpfx Ajzg Txqsbgew
Test chamber (W x D x H): approx. 4500 mm x 5000 mm x 2200 mm
Door opening (W x H): approx. 3000 mm x 2200 mm
Condition: used
Scope of delivery: (see picture)
(Specifications subject to change and errors excepted!)
For further questions, we are happy to assist you by phone.
Listing
Borken
785 km
Climatic chamber
RS-SimulatorenKKC 22/45L
Call
Condition: good (used), RS Simulators
Rodpjzg Txkofx Abgjw
Type: Walk-in Climate Simulation Chamber KKC 22/45L
Technical Data:
Temperature range: -40...+120 °C
Temperature tolerance: +/- 1.5°C
Temperature change rate: 1 K/min
Humidity range:
10...approx. 95% r.H.
Humidity tolerance:
+/- 5.0% r.H.
Dimensions:
Test chamber volume: 22 m³
External dimensions (W x D x H): approx. 2600 mm x 6400 mm x 2800 mm
Test chamber (W x D x H): approx. 2200 mm x 4700 mm x 2300 mm
Door opening (W x H): approx. 2200 mm x 2300 mm
Year of manufacture: 2009
Technical data for solar simulation:
Control module: Mitronic STB1-8
Number of lamps: 8
Ballast unit: Mitronic CP2k5 – 2ZS
Ignition unit: Hönle
Lamp type: OSRAM Powerstar HQI 2000W W/D/S
Condition: used / second-hand
Scope of delivery: (see image)
(Specifications subject to change and errors excepted!)
For further questions, feel free to contact us by phone.
Listing
Borken
785 km
Climatic chamber
RS-SimulatorenKKC 22/45
Call
Condition: good (used), RS Simulators
Type: Walk-in Climate Simulation Chamber KKC 22/45
Technical specifications:
Temperature range: -40...+120 °C
Temperature tolerance: +/- 1.5°C
Temperature change rate: 1 K/min
Redozg Txdepfx Abgsw
Humidity range:
10...approx. 95% r.h.
Humidity tolerance:
+/- 5.0% r.h.
Dimensions:
Test chamber volume: 22 m³
External dimensions (W x D x H): approx. 2600 mm x 6400 mm x 2800 mm
Test chamber (W x D x H): approx. 2200 mm x 4700 mm x 2300 mm
Door opening (W x H): approx. 2200 mm x 2300 mm
Condition: used
Scope of delivery: (see picture)
(Subject to change and errors in technical data!)
We are happy to answer further questions by phone.
Listing
Borken
785 km
Climatic chamber
TiraTCZ 4020 S-2k
Call
Condition: good (used), TIRA
Type: Walk-in Climate Simulation Chamber TCZ 4020 S-2k
Technical Specifications:
Temperature range: -40...+140°C
Temperature tolerance: +/- 1.0°C
Temperature change rate: 2 K/min
Humidity range: 10...approx. 95% r.h.
Humidity tolerance: +/- 5.0% r.h.
Rjdpfjzg Tw Tex Abgjw
Dimensions:
Test chamber volume: 19 m³
External dimensions (W x D x H): approx. 2660 mm x 4960 mm x 3300 mm
Test chamber (W x D x H): approx. 2270 mm x 3190 mm x 2756 mm
Door opening (W x H): approx. 2270 mm x 2756 mm
Condition: used
Scope of delivery: (see picture)
(Specifications subject to changes and errors!)
For further questions, we would be happy to assist you by phone.
Listing
Borken
785 km
Climatic chamber
TiraTCZ 4012
Call
Condition: good (used), TIRA
Type: Walk-in Climate Simulation Chamber TCZ 4012 S(m)
Technical Data:
Temperature range: -40...+120 °C
Temperature tolerance: +/- 1.0°C
Temperature change rate: 1 K/min
Humidity range: 10...approx. 95 % rH
Humidity tolerance: +/- 5.0 % rH
Dimensions:
Test chamber volume: 13 m³
External dimensions (W x D x H): approx. 2260mm x 3850mm x 2780mm
Test chamber (W x D x H): approx. 2254mm x 2645mm x 2251mm
Door opening (W x H): approx. 2251mm x 2254mm
Condition: used
Rjdszg Tw Hopfx Abgew
Delivery contents: (see picture)
(Subject to changes and errors in the technical data!)
For further enquiries, please contact us by phone.
Listing
Borken
785 km
Climatic chamber
TiraTTZ 4008
Call
Condition: good (used), TIRA
Type: Walk-in climate simulation chamber TTZ 4008 S(m)
Technical data:
Temperature range: -40 to +120 °C
Temperature tolerance: +/- 1.0 °C
Temperature change rate: 1 K/min
Humidity range:
10…approx. 95% RH
Humidity tolerance:
+/- 5.0% RH
Dimensions:
Test chamber volume: 8 m³
External dimensions (W x D x H): approx. 2410 mm x 3920 mm x 2530 mm
Test chamber (W x D x H): approx. 2002 mm x 2148 mm x 2005 mm
Door opening (W x H): approx. 2002 mm x 2005 mm
Condition: used
Scope of supply: (See image)
(Changes and errors in the technical data are subject to change!)
Rsdpfszg Twmox Abgsw
We would be happy to answer any further questions you may have by phone.
Listing
Borken
785 km
Climate test chamber 335 liters with humidity
VötschVCS 7034-5 -70°C bis +180°C
Call
Condition: good (used), Vötsch
Type: VCS 7034-5
Water-cooled climatic test chamber
Vötsch VCS 7034-5
Test chamber capacity 335 liters
Performance for temperature tests
Temperature range -70 to +180°C
Temperature deviation temporal K ±0.1 to ±0.5
Spatial temperature deviation K ±0.5 to ±2.0
Temperature gradient 1 to 4
Rate of change :
Cooling 6.7 K/min
Heating 6.8 K/min
Heat compensation at +20 °C 3000 W / at -20°C 3000 W
Temperature calibration values +23 °C and +80 °C
Performance for climate tests
Temperature range +10 to +95°C
Temperature deviation in time ±0.1 to ±0.3 K
Spatial temperature deviation ±0.5 to ±1.0 K
Temperature gradient 1 to 2 K
Humidity range 10 to 98%
Humidity deviation in time ±1 to ±3%
Dew point range -3 to +94°C
Heat compensation 400W
Climate calibration values +23 °C / 50 % r.h. and +95 °C / 50 % r.h.
Test chamber dimensions: Width 580mm Depth 765mm Height 750mm
External dimensions: Width 870mm Depth 1595mm Height 1775mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10kW
Rsdpfx Ajzg Twgobgew
Rated current: 21 A
Sound pressure level: 64dB(A)
Cooling water consumption: 1.4m³/h
Refrigerant: R-404A / R-23
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
785 km
Climatic chamber temperature and humidity
EspecPHP-J3 bis +100°C
Call
Condition: excellent (used), Espec
Type: PHP - J3
Technical Data:
Air-cooled
Temperature and humidity range: Ambient temperature +10°C to +100°C / 40 to 98% relative humidity
Temperature fluctuation: ±0.3 K
Rsdpfx Abjzgtahsgsw
Humidity fluctuation: ±2.5%
Internal volume: 398 liters
Dimensions:
Internal dimensions: Width 600 mm x Height 830 mm x Depth 800 mm
External dimensions: Width 1010 mm x Height 1690 mm x Depth 1273 mm
Mains voltage: 400 VAC 3-phase 50 Hz
Maximum current: 400 VAC 8.3 A
Weight: 335 kg
Scope of delivery: Espec climate test chamber
For your safety as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by telephone.
Listing
Borken
785 km
Climatic chamber with humidity, 34 liters
WeissWKL 34/60 -60°C bis 150°C
Call
Condition: excellent (used), Weiss
Type: WKL 34/60
Weiss Climate Chamber, Air-Cooled
Refrigerant converted to R-452A
-60°C to 150°C
Volume: 34 liters
Installed in basic configuration:
R1 NW 50 mm
L1NW 120 mm
Internal dimensions: Height 310 mm, Width 324 mm, Depth 300 mm
External dimensions: Height 1740 mm, Width 630 mm, Depth 970 mm
Performance data for temperature tests:
Temperature range -60 to +150 °C
Temperature differences in steady state, according to IEC 60068-3-5
Temperature fluctuation over time in the center of the usable space ± 0.3 to ± 1 K ± 1 to ± 2 K
Temperature deviation spatially (corresponds to temperature gradient) 2 to 4
Temperature change rate (according to IEC 60068-3-5)
Heating 2.5 K/min
Cooling 3 K/min
Heat compensation max. 550 W
Performance data for climate tests:
Rsdpfx Abszgr U Rogow
Temperature range +10 to +95 °C
Humidity range 10 to 98 % RH
Temperature and humidity differences (in steady state, according to IEC 60068-3-5)
Temperature fluctuation over time in the center of the usable space ± 0.3 to ± 0.5 K
Temperature deviation spatially ± 0.5 to ± 1.5
(corresponds to temperature gradient) 1 to 3
Humidity fluctuation over time in the center of the usable space ± 3 to ± 5 % RH
Operating data:
Test chamber lighting Halogen bulb 12V, 20W
Rated voltage 1/N / PE AC 230 V ± 10 % 50 Hz
Rated power 2.5 kW
Rated current 11 A
Fuse on customer side 16A slow-blow
Heat dissipation of air-cooled test chambers
Max. heat dissipation to the environment 1700 W
Refrigerant: R-452A / R23
Weight: 140 kg
For your safety as a buyer, please note the following:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in technical data are subject to change!)
We will gladly answer any further questions you may have over the phone.
Listing
Borken
785 km
Climate chamber
DycometalCCK -40/1500 T 1500 Liter
Call
Year of construction: 2022, condition: excellent (used), Dycometal
Type: CCK -40/1500T
Water-cooled climate chamber
Volume in liters: 1500
Internal dimensions: height 1000 mm, width 1000 mm, depth 1500 mm
External dimensions: height 2200 mm, width 1293 mm, depth 3400 mm
Thermal testing
Minimum temperature: -40°C
Maximum temperature: +150°C
Cooling rate: 2.0 K/min
Heating rate: 3.5 K/min
Temperature stability: ±0.1°C to ±0.3°C
Temperature uniformity: ±0.5 °C to 1.5°C
Climate testing, temperature range: +10°C to +90°C
Humidity range: 10% to 98% RH
Dew point range: +6.5°C to +86°C
Humidity stability: ±1% RH to ±3% RH
Condenser: water-cooled
Rated voltage: 400 V 3N~PE 50 Hz
Power: 16.1 kW, 27.5 A
Refrigerant: R-452A
Weight: 1120 kg
Condition: used
Redpfszgr Rrsx Abgew
Scope of delivery: (See image)
(Subject to changes and errors in the technical data and specifications!)
We will be happy to answer any further questions you may have by phone.
Listing
Borken
785 km
Climate test chamber 335 liters 10-98% relative humidity.
VötschVC³ 0034 -10 °C bis +90 °C
Call
Condition: excellent (used), Vötsch VC³ 0034 Climate Test Chamber
Manufacturer: Vötsch Industrietechnik GmbH
Type: VC³ 0034
Machine Type: Climate Test Chamber / Climate Chamber
Test Chamber Volume: approx. 335 liters
For sale is a used climate test chamber from Vötsch for temperature and climate testing in laboratories, research, development, and quality assurance.
Technical Data
Test Chamber Dimensions: approx. 580 x 765 x 750 mm (W x D x H)
Housing Dimensions: approx. 875 x 1860 x 1805 mm (W x D x H)
Temperature Range: -10 °C to +90 °C
Humidity Range: 10 to 98 % RH
Dew Point Range: +4 °C to +89.5 °C
Temperature Homogeneity: ±0.5 to ±1 K
Temperature Deviation: ±0.1 to ±0.5 K
Heating Rate: approx. 1 K/min
Cooling Rate: approx. 0.3 K/min
Max. Heat Compensation: approx. 200 W
Refrigerant: R404A
Filling Quantity: 0.6 kg
ND max.: 25 bar g
HD max.: 25 bar g
Power Connection: 230 V / 50 Hz
Rated Power: 2.3 kW
Rated Current: 10 A
Protection Class: IP54
Weight: approx. 490 kg
Equipment
SIMPAC control system
Temperature and humidity control
Stainless steel test chamber
Ethernet, USB, RS232, RS485/422
Test item protection function
Cable glands
Redpozgb Awsfx Abgew
Application Areas
Climate testing
Temperature testing
Material testing
Electronics testing
Quality assurance
Research and development
Scope of Supply
Vötsch VC³ 0034 Climate Test Chamber
Accessories as shown in the pictures
Condition
Used
Optical condition as shown in the pictures
For the safety of our customers, the offered climate chambers are tested before delivery,
if necessary, filled with legally compliant refrigerant, subjected to a leak test,
and delivered with a documented test run.
Subject to change and errors in technical data as well as prior sale.
Listing
Borken
785 km
Climate chamber
WEISSWK1-1000/70
Call
Condition: good (used), Weiss
Type: WK1-1000/70
Weiss Climate Testing Chamber, Water-Cooled
(Refrigerant converted to R-452A)
Control panel: "Touchpanel"
All control and operating commands can be initiated on the "Touchpanel" by simply touching the function symbols.
Feedthroughs
The test chamber is equipped with feedthroughs on the right and left sides.
These allow measuring cables and testing equipment to be placed in the test chamber.
Feedthroughs:
1 feedthrough, diameter 125 mm, installed on the right
1 feedthrough, diameter 50 mm, installed on the left
Volume: 990 liters
Test chamber dimensions:
Test chamber: width 1100 mm, depth 950 mm, height 950 mm
Housing: width 1385 mm, depth 1850 mm, height 1980 mm
Data for temperature tests:
Minimum temperature: -70 °C
Maximum temperature: +180 °C
Temperature deviation, over time: ± 0.1 to ± 0.5 K
Temperature homogeneity, spatially: ± 0.5 to ± 2 K
Temperature change rate, heating: 4 K/min
Temperature change rate, cooling: 2.5 K/min
Maximum heat compensation: 2750 W
Data for climate tests:
Temperature range: +10°C to +95°C
Humidity range: 10 to 98% RH
Temperature deviation, over time: ± 0.1 to ± 0.3 K
Rjdpfxozgbtpe Abgow
Temperature homogeneity, spatially: ± 0.5 to ± 1 K
Humidity deviation, over time: ± 1 to ± 3% RH
Data for operation:
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated current: 29A, rated power: 19.8 kW
Refrigerant: R-452A / R23
Weight: approx. 910 kg
For your security as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by telephone.
Listing
Borken
785 km
Climate test chamber with humidity, 335 liters
WeissWK3-340/40 -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss climate testing chamber.
Weiss climate testing chamber, water-cooled
(Refrigerant converted to R-452A)
Temperature testing
Volume 335 liters
Test chamber dimensions:
Test chamber dimensions: Height 750 mm, Width 580 mm, Depth 765 mm
External dimensions: Height 1775 mm, Width 870 mm, Depth 1600 mm
Rsdozgavvjpfx Abgsw
Minimum temperature -42°C
Maximum temperature +180°C
Temperature change rate, cooling 4 K/min
Temperature change rate, heating 3.2 K/min
Temperature deviation, time-based ± 0.1 to ± 0.5 K
Temperature homogeneity, spatially ± 0.5 to ± 1.5 K
Climate testing:
Temperature range +10°C to +95°C
Dew point range -3°C to +94°C
Humidity range 10 to 98% RH
Temperature deviation, time-based ± 0.1 to ± 0.3 K
Temperature homogeneity, spatially ± 0.5 to ± 1 K
Humidity deviation, time-based ± 1 to ± 3 % RH
Voltage: 3/N/PE AC 400V±10% 50Hz
Rated power 4.1 kW Rated current: 14 A
Refrigerant: R-452A
Type: WK3-340/40
Weight Approx. 515 kg
For your security as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have over the phone.
Listing
Borken
785 km
Climate test chamber -40 to +180°C
WeissWK-480/40/10 480 Liter m. Feuchte
Call
Condition: excellent (used), We are offering a Weiss climate testing chamber.
Water-cooled.
Test chamber lighting: halogen bulb 24V, 50W.
Data for temperature tests:
Temperature range: -40°C to +180°C.
Temperature deviation over time in the center of the usable space: ± 0.3 to ± 0.8 K.
Temperature deviation spatially: ± 0.5 to ± 2 K.
Temperature change rate:
Heating: 10 K/min.
Cooling: 12.5 K/min.
Rjdpfx Aozgaipobgew
Heat compensation at +20°C: 8000 W.
Heat compensation at -20°C: 3000 W.
Data for climate tests:
Temperature range: +10°C to +95°C.
Humidity range: 10 to 98 % RH.
Temperature deviation over time in the center of the usable space: ± 0.2 to ± 0.5 K.
Temperature deviation spatially: ± 0.5 to ± 1 K.
Humidity fluctuation over time in the center of the usable space: ± 1 to ± 3 % RH.
Test chamber dimensions: height 950 mm, width 760 mm, depth 650 mm.
External dimensions: height 2025 mm, width 1090 mm, depth 2480 mm.
Rated voltage: 3/N/PE AC 400 V ± 10% 50 Hz.
Rated current: 24 A. Rated power: 16.0 kW.
Refrigerant: R452A.
Weight: approx. 900 kg.
Type: WK-480/40/10.
For your security as a buyer, please note the following:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components.
2. If necessary, new filling with legally compliant refrigerant.
3. Leak test with certificate.
4. After successful inspection, the chambers undergo a documented test run.
Condition: used.
Scope of delivery: (See image).
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by telephone.
Listing
Borken
785 km
Walk-in climate chamber with humidity control
RS-SimulatorenKKM 40/45S
Call
Condition: excellent (used), Here we offer you a walk-in climate chamber.
Manufacturer: RS-Simulatoren, water-cooled
The chamber can be disassembled into three parts for transportation (bolted construction).
Temperature range: -30°C to +100°C
Rsdjzgabljpfx Abgjw
Refrigerants: 20kg R-404A + 20kg R-452A
External dimensions (approx.): Width 3,920 mm, Depth 7,350 mm, Height 2,600 mm
Test chamber/internal dimensions (approx.): Width 3,500 mm, Depth 5,400 mm, Height 2,110 mm
Electrical data: 68kW rated power
Voltage: 3x400V/PE, Current: 135A
Model: KKM 40 / 45 S
Further technical details will follow!
For your peace of mind as a buyer, please note the following:
We carry out the following procedures on all chambers offered:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful checks, the chambers undergo a documented test run
Condition: used
Scope of delivery: see picture
(Subject to changes and errors in the technical data and specifications!)
For further questions, feel free to contact us by phone.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
785 km
Climatic chamber
VötschVCS 7033
Call
Condition: excellent (used), Heraeus Vötsch Climate Chamber
Rsdpfx Abszfy Rqegew
Here, we offer a Heraeus Vötsch climate chamber.
Vötsch Climate Chamber VCS 7033, Water-Cooled
Temperature range: -70°C to +180°C
Temperature change rate:
Heating: 7.5 K/min
Cooling: 6.5 K/min
Humidity range: 10% to 98% RH
Temperature deviation (temporal): ± 0.5 K
Temperature deviation (spatial): ± 1.5 K
Test chamber dimensions: Width 675 mm x Depth 650 mm x Height 760 mm
Housing dimensions: Width 930 mm x Depth 1565 mm x Height 1840 mm
Side feed-through: 90 mm diameter
Approx. 330 L, Weight: 600 kg
Voltage: 3/N/PE AC 400V ±6/-10% 50Hz
Rated power: 9.5 kW
Rated current: 17 A
Refrigerant: R404A / R23
Type: VCS 7033
For your safety as a buyer, please note the following information:
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with refrigerants that comply with legal requirements
3. Leak test with certificate
4. After successful inspection, the chambers undergo a test run, which is monitored with calibrated devices.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data and information are subject to change!)
We will be happy to answer any further questions you may have by phone.
Listing
Borken
785 km
Climate test chamber with humidity
WeissSB2/500/80 -75°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss climate test chamber.
Designation: SB2/500/80, water-cooled
Cold-heat operation: -75°C ... +180°C
Climate operation: +10...+95°C
Humidity range: 10...98 % RH
Temperature stability, over time: ± 0.2K
Humidity stability: ±1 % RH
Temperature change rate:
Cooling: approx. 1.4 K/min
Heating: approx. 2.5 K/min
External dimensions: Height 1980 mm, Width 1265 mm, Depth 1365 mm
Connections:
left side: ∅ 100 mm
right side: ∅ 50 mm
The connection voltage is:
400V/3Ph+N+PE/50 Hz
Power: 10.4 kVA
Weight: approx. 720 kg
Refrigerant: R404a / R23
For your security as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. Leakage test with certificate
4. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Redozd Ultopfx Abgjw
Type: SB2/500/80
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data and information are subject to change!)
We will gladly answer any further questions you may have over the phone.
Listing
Borken
785 km
Climatic test chamber
Feutron3702/06
Call
Condition: excellent (used), Feutron
Type: 3702/06
Water-cooled climate test chamber
Technical data:
Nominal volume of test chamber: 2.0 m³
Dimensions: Test chamber exterior, with humidifier console
Width: 2970 mm, Height: 2370 mm, Depth: 1530 mm
Rear wall
Minimum insertion dimensions: Width: 2970 mm, Height: 2390 mm, Depth: 1550 mm
Test chamber: Width: 2000 mm, Height: 1000 mm, Depth: 1000 mm
Door: double-leaf, clear opening width 2000 mm, height 1000 mm
Viewing window, heated, 2 pieces, width 500 mm, height 600 mm
Feed-through opening, 1 piece, left side wall, diameter 75 mm
Temperature range: -40...100°C
Climate range: 10...95°C
Temperature difference, time-dependent ≤ ± 0.5...± 1.0 ΔN/K
Rate of change measured in the supply air, without load
Cooling up to 2.0 on average K/min
Heating up to 2.0 on average K/min
Humidity range: 10...95 % RH
Humidity difference, time-dependent ≤ ± 3.0 % RH
Dew point range, intermittently up to -5...95°C
Refrigeration system: water-cooled, semi-hermetic Bitzer system
Refrigerant: R507 (Μ-Κ1)
Climate and dryer refrigeration system: air-cooled / hermetic system
Refrigerant: R134a (Μ.ΚΚ)
Rjdpfxezd Sdme Abgjw
Power supply:
Electrical connection: 400V 3/N/PE.AC, 50Hz
Power plug: CEE 5-pin, 32 A, with 5.0 m cable
Max. simultaneous power requirement: 10.0 kW
Supply line fuse: 3x 25, Char, C A
Protection class: IP20
Weight: 1300 kg
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data and specifications are subject to change!)
We will be happy to answer any further questions you may have over the phone.
Listing
Borken
785 km
Climate test chamber with humidity control
Feutron3707/06 Temp. -40°C bis 150°C
Call
Condition: excellent (used), Here we offer a Feutron climate test chamber.
Feutron Climate Test Chamber
Temperature
Temperature range: -40...90°C
Climatic range (without heat load): 10...85°C
Temporal temperature deviation during temperature operation: ≤ ± 0.5 K/min
Temporal temperature deviation during climatic operation: ± 1.0... ± 1.5 K/min
Change rates
Heating: avg. 2.0 K/min
Cooling: avg. 2.0 K/min
Standard IEC 1646 is achievable with testing, solar modules up to max. 160kg weight and nonlinear ramps (setpoint jump)
Drying
Air drying: condensation drying
Humidity
Air humidification: steam humidification
Humidity range: 10...95 % r.h.
Temporal humidity deviation: ≤ ± 3.0... ±5.0 % r.h.
Dew point range: 8...80.9°C
Test Chamber
Test chamber volume: 7.0 m³
Dimensions
Internal dimensions: Width 1500 mm x Height 2250 mm x Depth 2000 mm
Swing door DIN right, heated, Width 900 mm x Height 2100 mm
Observation window, heated, with blackout shutter and lockable: Width 500 mm x Height 600 mm
Feedthrough: 2x, right front side, Ø 75 mm
Irradiation unit, test chamber
Opening: 4x in left side wall for SC 2500, each 850 x 700 mm
Irradiated area when using SC 2500: 1200 x 1200 mm
Radiation intensity at 1.0 m wall distance: 1000 ± 10% W/m²
Lighting: 1x halogen lamp, 200W
Refrigeration system: Bitzer compressor, semi-hermetic, 2-stage, air cooled
Condenser: split condenser (outdoor installation, winter control)
Refrigerant: R507 / R23
Temperature control system
Coolant medium Tyfocor / water
Mixing ratio 50/50%
Coolant density: 1.072 kg/dm³
Filling quantity: approx. 80 dm³
Pyranometer
Temperature range: -40...150°C
Max. radiation absorption: 4000 W/m²
Spectral range (50% points): 305...2800 nm
Sensitivity (nominal): 7 µV/W/m²
Power supply, test chamber
Mains connection: 400V, 3/N/PE, AC, 50Hz
Connection type: hardwired
Max. simultaneous power demand: approx. 32.0 kW
Supply fuse: 3 x 63, Char C (A)
Rodpfx Abezd Sdgjgsw
Power supply, SolarConstant
Mains connection: 400V, 3/N/PE, AC, 50Hz
Connection type:
Max. simultaneous power demand: approx. 30.0 kW
Supply fuse: 3 x 63, Char C (A)
Overall external dimensions of the test cell including: equipment room/control cabinet and control cabinet for SolarConstant 2500
External dimensions equipment room: Width 3440 mm x Height 2580 mm x Depth 2950 mm
/control cabinet: Width 2200 mm x Height 1830 mm x Depth 1100 mm
External dimensions condenser, split: Width 900 mm x Height 950 mm x Depth 2000 mm
Weight test chamber (total): approx. 2700 kg
Condenser empty weight: 153 kg
Weight: 2700 kg
Type: 3707/06
Condition: used
Scope of delivery: (see picture)
(Technical data and information are subject to change and errors!)
For further questions, we are happy to assist you by phone.
We make it easier for you to find: "climate chamber"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Climate Chamber (5,990)
Search Machineseeker now with more than 200,000 used machines:Browse through the most popular machine descriptions:
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month











































































































































































































