Used Climatic Chamber for sale (5,272)
Sort results
- Lowest price Highest price
- Latest listings Oldest listings
- Shortest distance Farthest distance
- Latest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Latest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Latest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation A to Z
- Designation
- designation Z to A
- Designation
- Model A to Z
- Model
- Model Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest running time
- Runtime
- Relevance
- Relevance
Listing

785 km
Climatic chamber
CTSCS-70/1850-5
Call
Condition: good (used), CTS climatic test chamber
Here we offer a CTS climatic test chamber.
Climate test chamber type: CS-70/1850-5 water-cooled
1) C means: Climate
2) S means: stress screening
3) -70 means: lower temperature -70°C
4) 1850 means: 1850 liter test chamber volume
5) 5 means: Temperature change rate of 5 K/min according to IEC 60068-3-5
Test chamber lighting:
Halogen lamp 20 W, 12 V
Control:
32 bit controller
LCD control panel
Digital display of set and actual values
Numerical input of setpoint values
Error messages in plain text
RS 232 interface
Free switching channels for on-site test material control
Technical performance data:
Temperature tests:
Temperature range -70°C to +180°C
Temperature deviation ≤ ± 0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 5 K/min
Cooling 5 K/min
Heat radiation:
approx. 5500 W at +20°C
approx. 5500 W at ± 0°C
approx. 3700 W at -40°C
Climatic tests:
Temperature range +10°C to +95°C
Humidity range 10% to 98% rel. humidity
Dew point range I: +7°C to 94°C
Dew point range II (deep dehumidification): -10°C to +7°C
Biw3Geynzsq
Temperature deviation ≤ ± 0.3 K in time
Humidity deviation I ≤ ±1.5% r.h. over time
Humidity deviation II ≤ ±3 % r.h. over time
Dimensions:
Test volume 1850 liters
Test chamber dimensions: Height 1085 mm Width 1470 mm Depth 1400 mm
External dimensions: Height 2210 mm Width 1600 mm Depth 2645 mm
Insert grid:
Stainless steel, support surface 1300 x 1170 mm
Max. load per shelf 35 kg
Total load with max. grate load 100 kg
1a Pipe feed-through NW 50
1b Pipe feed-through 2x NW 125
2 Control panel
3 Window 570x710
4 Electrical connection, fixed
5 Pressure equalization
7 Test chamber drain and
air conditioning system R 1/2 "i
8 Demineralized water inlet R 1/2 "i
9 Cooling water return R 3/4 "i
10 Cooling water inlet R 3/4 "i
11 Main switch
12 Electrical compartment
13 Compressed air R 1/4 "AG, option
14 Cable bushing for interface connections
Technical version:
Refrigeration unit:
Water-cooled, low-noise, semi-hermetic,
infinitely variable capacity adjustment through electronic
monitoring and control system, environmentally
friendly refrigerant R404A/ R23
Compressor: 4EC-4.2Y / 4CC-6.2Y
Operating data:
Electrical connection: 400V +6/-10 %, 3/N, 50 Hz
Rated output: 33 kW Rated current: 41.3 A
Protection class: IP 22
Weight: approx. 1300 kg
Type: CS-70/1850-5
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

1,548 km
Memmert HPP 108 climatic chamber
MemmertHPP 108
Call
Condition: excellent (used), Memmert HPP 108 climatic chamber.
Manufacturer's description
Ventilation and control:
- Forced air circulation through built-in fan
- Microprocessor PID controller with fuzzy logic for smooth control of the cooling and heating system with Peltier cells
- Built-in self-diagnosis system with display of temperature and humidity errors
- 2 Pt100 class A sensors, 4-wire circuit, simultaneously monitoring and maintaining performance at the same temperature.
- Digital, 7-day, time programmer with real-time clock and precise min. setting.
- Built-in time programmer for heating / cooling with the possibility of creating profiles, each up to 40 ramps, segment time adjustment from 1 min. to 999 hrs.
- Digital display (LED) of all parameters, such as temperature, day, time, humidity and other settings, e.g. language
- Digital display of the value. entered/current: resolution 0.1°C,
- Possibility of archiving data in accordance with GLP thanks to the recorder with 1024kB memory
- Non-volatile program memory
- Parallel printer port (including real-time clock with date function) for all PCL3-compliant inkjet printers, ensuring documentation in accordance with GLP
- USB port and Memmert "Celsius" software for programming and documentation
- MEMoryCard XL with 32kB (up to 40 ramps)
- Calibration certificates for +10°C and +37°C at 60% rH.
Humidification and dehumidification system:
- Active humidification and dehumidification system from 10 to 90% rH with digital display (resolution: 0.5%, setting accuracy 1% rH)
- Humidification using distilled water taken from an external tank to steam generator via built-in pump
- Humidification by hot steam generator
- Dehumidification using Peltier plates via cold trap
- Independent, programmable electronic protection against too high temperature. TWW class 3.1
- Additional, adjustable "ASF" function - automatically adjustable protection against exceeding the upper or lower temperature limit depending on the set operating temperature
Housing made of stainless steel:
- Fully insulated, stainless steel door with double lock and 4-point adjustment
- Internal glass door
- Rear panel: galvanized steel plate
Interior:
- Easy to clean, made of stainless steel (1.4301), reinforced with ribs, electropolished and hermetically welded
- 2 stainless steel shelves, brass for HPP 749, perforated for HPP 108
Heating and cooling system:
- Energy-saving, heating and cooling Peltier plate system built into the rear of the housing
Protection against excessive temperature:
- With audible and visual alarms in the event of exceeding temperature, humidity or lack of water in the tank
- Digital, adjustable, electronic controller. TWW protection class 3.3
- ASF function, enabling automatic return to the set values. after exceeding the permissible limits
Operating temperature range:
- From +5°C to +70°C / from +10°C to +40°C with optional light
- Temperature accuracy in the chamber at 10°C and 37°C: < ±0.4°C HPP 108, £ < ±0.5°C HPP 749
Power supply / Nominal power:
Baqg9Horfi
- 230 V (+/- 10%), 50 / 60 Hz
- Approx. 350 W (during heating and cooling) for HPP 108 and 1050 W for HPP 749
Listing

988 km
Climatic chamber
WeissWKS 3-800/40/15
Call
Year of construction: 2013, Condition: ready for operation (used), Functionality: fully functional, machine/vehicle number: WKS 3-800/40/15, Weiss climatic test chamber WKS 3-800/40/15 -42 to +180°C and humidity,
with temperature change rate of 15 K/min, external cooling, in excellent condition, well maintained and serviced.
In addition, the entire test unit is calibrated and certified accordingly.
Product advantages:
- Calibrated test stand (DAkkS calibration method A)
- Rapid temperature changes (15 K/min)
- Climate change
- Usable volume 800 l
- Interfaces for functional tests during the test cycle
Data for temperature tests:
Temperature range: -42°C to +180°C
Temperature change rate cooling 18.0 K/min
Temperature change rate heating 16.0 K/min
Temperature deviation, temporal ± 0.3 to ± 0.5 K
Dpfjlr
Temperature homogeneity, spatial ± 0.5 to ± 2.0 K
Heat compensation at +20°C 8000 W
Thermal compensation at -20°C 3000 W
Data for climatic tests
Temperature range: +10 to +95 °C
Humidity range: 10 to 98 % r.h.
Humidity deviation in time ± 1 to ± 3
Heat compensation max 500 W
Temperature deviation in time ± 0.2 to ± 0.3 K
Temperature homogeneity in space: ± 0.5 to ± 1 K
Permissible test material weight:
Total load test chamber floor 150 kg, insert grid 50 kg
Insert grid 4 pieces
Total load of insert grid 100 kg
Test chamber dimensions: Height 925 mm, width 1100 mm, depth 800 mm
External dimensions: Height 2000 mm, width 1415 mm, depth 2810 mm
Test chamber capacity: 800 liters
Feed-throughs: 1x 140mm ∅ / 1x 100mm ∅ / 1x 90mm ∅ 1x 50mm ∅ 2x 80mm ∅
Data for operation:
Rated voltage: 3/N/PE AC 400V ± 10% 50Hz
Rated current: 70 A Rated power 36.0 kW
Refrigerant: R-404A
Weight: 1500 kg

Find out now
+44 20 806 810 84
+44 20 806 810 84
Create listing
*per listing / month
Listing

776 km
Climatic test chamber -40°C to +120°C Chamber
Vötsch VSKZ 04/120/S
Call
Condition: excellent (used), Vötsch VSKZ 04/120/S
Bsa2Ztsihwk
Climatic test chamber
-40°C to +120°C
climatic chamber
Climatic chamber
Inside: Width 2.60 m Depth 2 meters Height 2 meters
Listing

785 km
Climatic test chamber 335 liters with humidity
VötschVCS 7034-5 -70°C bis +180°C
Call
Condition: good (used), Vötsch
Type: VCS 7034-5
Water-cooled climatic test chamber
Vötsch VCS 7034-5
Test chamber capacity 335 liters
Performance for temperature tests
Temperature range -70 to +180°C
Temperature deviation temporal K ±0.1 to ±0.5
Spatial temperature deviation K ±0.5 to ±2.0
Temperature gradient 1 to 4
Rate of change :
Cooling 6.7 K/min
Heating 6.8 K/min
Heat compensation at +20 °C 3000 W / at -20°C 3000 W
Temperature calibration values +23 °C and +80 °C
Performance for climate tests
Temperature range +10 to +95°C
Temperature deviation in time ±0.1 to ±0.3 K
Spatial temperature deviation ±0.5 to ±1.0 K
Temperature gradient 1 to 2 K
Humidity range 10 to 98%
Humidity deviation in time ±1 to ±3%
Dew point range -3 to +94°C
Heat compensation 400W
Climate calibration values +23 °C / 50 % r.h. and +95 °C / 50 % r.h.
Test chamber dimensions: Width 580mm Depth 765mm Height 750mm
External dimensions: Width 870mm Depth 1595mm Height 1775mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10kW
Rated current: 21 A
Sound pressure level: 64dB(A)
Cooling water consumption: 1.4m³/h
Uym8N7Wjlx
Refrigerant: R-404A / R-23
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Discover more used machines
Listing

1,548 km
Memmert HPP 260 climatic chamber
MemmertHPP 260
Call
Condition: excellent (used), Memmert HPP 260 climate chamber for sale
Operating temperature range from 0°C (20°C below ambient temperature) to +70°C Capacity 260 liters. Humidity adjustable from 10 to 90%RH.
Temperature
Setting temperature range
without light, with humidity: +5 to +70 °C
Setting temperature range
with light, with humidity: +5 to +70 °C
Setting temperature range
with light, without humidity: 0 to +70 °C
Setting temperature range
without light, without humidity: 0 to +70 °C
Working temperature range
with light, without or with humidity: 15 to +40 °C
Working temperature range
without light, with humidity: +5 (at least 20 below ambient temperature) to +70 °C
Working temperature range
without light, without humidity: 0 (at least 20 below ambient temperature) to +70 °C
Humidity
Setting range humidity
10 - 90% rh
Control technology
Function HeatBALANCE
adapting the distribution of the heating performance of the upper and lower heating circuit from -50 % to +50 %
Standard equipment
Works calibration certificate
standard values +10 °C and +37 °C, 60 % rh at +30 °C
Door
fully insulated stainless steel door with 2-point locking (compression door lock)
Door
inner glass door
8Vj9Ktzmy
Listing

785 km
Climatic chamber
Heraeus VötschVC³ 0100
Call
Condition: excellent (used), Heraeus Vötsch climatic test chamber
Here we offer Heraeus Vötsch climatic test chamber.
Designation VC³ 0100
Test chamber dimensions: H x W x D, approx. 950 x 1100 x 950 mm
TEMPERATURE TESTS:
Minimum temperature -0°C
Maximum temperature +90°C
Temperature change rate cooling 0.2 K/min
Temperature change rate heating 0.5 K/min
Temperature deviation in time ± 0.1 to ± 0.5 K
Temperature homogeneity in space ± 0.5 to ± 1.0 K
Heat compensation at +20 °C 350W
CLIMATIC TESTS:
Minimum temperature +10°C
Maximum temperature +90°C
Dew point temperature range +4°C to +89.5°C
Humidity range 10 to 98% r. h.
Humidity deviation over time ± 1 to ± 3% r. h.
Temperature deviation temporal ± 0.1 to ± 0.3K
Temperature homogeneity in space ± 0.5 to ± 1.0K
Voltage: 1/N/PE AC 230V±10% 50Hz
Rated power: 2.6 kW
Nominal current: 12 A
Refrigerant: R 404A
Weight approx. 1400 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Type: VC³ 0100 / year of construction 2013
Condition: second-hand / used
Scope of delivery: (see picture)
(Subject to changes and errors in the technical data and specifications!)
Carvktl7
We will be happy to answer any further questions you may have on the phone.
Listing

1,548 km
Binder KMF 720 climatic chamber
BinderKMF 720
Call
Condition: as good as new (ex-display), Binder KMF 720 E6 climatic chamber as new
Manufacturer's description:
Binder climatic chambers are used to test the behavior of materials in conditions of constant humidity and temperature.
These devices operate in the temperature range from -10 °C to 100 °C, as well as in the humidity range from 10% to 98% of the relative value.
The distinguishing feature of Binder KBF is absolutely reliable stability tests and precise maintenance of constant climatic conditions
Precise maintenance of climatic conditions makes the chambers excellent for stability tests.
Dqxwoj
Efficient operation is provided by a USB port enabling data logging and accurate reading of measurement values.
The ideal solution is the use of an intuitive controller equipped with a touch screen with time interval programming and real-time programming, thanks to which the device is comfortable and easy to use.
The climatic chamber is designed based on a modular structure and the interior is covered with stainless steel, which allows easy cleaning of the equipment. In addition, a special TIMELESS coating has been applied to the glass to prevent glass corrosion.
The use of APT.line™ preheating technology ensures that the air circulation in the usable volume is smooth and even.
The humidity level can be precisely regulated and thus completely adapted to individual requirements.
The Binder KMF model is characterized by absolutely constant conditions in the entire test chamber.
A major advantage of this chamber is its low space requirement and its flexibility in terms of water supply. The wide temperature and humidity range makes it the best choice for a number of durability tests.
These chambers are ideal for testing the stability and durability of industrial products. They are also used for conditioning samples in material tests of paper, plastics, building materials, textiles and other materials.
Characteristic features:
Inner chamber made entirely of stainless steel
Communication software
BINDER APT-COM™ 3 Basic Edition
Intuitive touchscreen controller with time interval programming and real-time programming
Internal data logger, measurement values in open format can be read via USB
Device self-test for comprehensive status analysis
Sealably closing inner door made of safety glass
Glass corrosion prevention thanks to special TIMELESS coating
1 stainless steel wire shelf
Access port with 30 mm silicone plug, left side
Class 3.1 temperature sensor with optical and acoustic temperature alarm
PC interface: Ethernet
Door heating
Listing

785 km
Climatic chamber
VötschVCL 4330 MH/S
Call
Condition: used, Vötsch
Type: VCL 4330 MH/S
Water-cooled
4 x SOL 2000 IC to simulate sunlight
Room volume 3300 liters
Characteristic values for temperature tests without irradiation:
Temperature range without insulating lid -30°C to +100°C
with insulating lid -40°C to +180°C
Temperature deviation over time
in steady state ±1K
Heating speed according to DIN 50011 part 12 3 K/min
Cooling rate according to DIN 50011 part 12 2 K/min to -30°C
Characteristic values for climatic tests without irradiation:
Temperature range +10°C to +90°C
Temperature deviation over time in steady state ±0.5 K
Humidity range 10% to 95% r.h.
Dew point range +5°C to +88°C
Humidity deviation over time in steady state ± 1 to 3 % r.h.
Characteristic values for temperature tests with irradiation:
Temperature range -10°C to +100°C
Temperature deviation over time in steady state ±1K
Bsdphw0Rtgi
Heating speed according to DIN 50011 part 12 3 K/min
Cooling rate 1.5 K/min (down to -10°C)
Irradiation device with metal halide emitter
Irradiation device:
Weight approx. 1800 kg {Gesamtgewicht}
2 kW halide emitter 4 pieces
Irradiance 1000 W/m² ± 5%
Wavelength 280 to 3000 nm"
Distance from lower edge of irradiation unit to reference plane 750 mm
Size of reference plane 1700 x 800 mm
Nominal voltage 400 V, +6/-10%, 3/N, 50 Hz
Nominal power 34 kW {Gesamtanschluss}
Rated current 79 A {total connection)
Fuse on site 100 A (total connection)
Characteristic values for climatic tests with irradiation:
Temperature range +10°C to +80°C
Temperature deviation over time in steady state ±1K
Humidity range 10% to 85% r.h.
Dew point range +5°C to +76°C
Humidity deviation over time in steady state ±1 to 3% r.h.
Sunlight simulation system:
4 x SOL 2000 IC for simulating sunlight
Functional description:
The radiator section consists of 4 SOL 2000 radiator modules.
Technical data:
Electrical data
Complete system
Nominal voltage: 230 / 400V 3N PE
Nominal frequency: 50Hz
Rated power: 10 kVA compensated
Protection class: without moisture protection
Spotlight module Spotlight SOL 2000
Rated voltage: 400V
Rated frequency: 50Hz
Rated current: 6 A compensated
Starting current: 10 A compensated
Protection class: IP20
Operating part:
Rated voltage: 230 / 400V 3NPE
Rated current: (continuous) 17 A/ phase
(start) approx. 30 A / phase
Short-circuit resistance: 6 kA
Control voltage: 24 V DC
Protection class: IP 54
built according to VDE: 0113
Electrical data:
Climatic test chamber
Operating conditions of the radiator modules
Humidity:
max. 90% rel. humidity at 20°C
max. 50% rel. humidity at 35°C
Ambient temperature: max. 35°C
Test room dimensions: width 2000 mm x depth 1150 mm x height 1510 mm
External dimensions: Width 3500 mm x depth 1450 mm x height 2100 mm
Refrigerant: R404A
Climate test chamber Weight approx. 1550 kg
Irradiation device Weight approx. 1800 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Climatic chamber
VötschVC 7150
Call
Condition: excellent (used), Vötsch climate chamber
Here we offer a Vötsch climatic test chamber.
Water-cooled
Vötsch climate chamber
Zoecayr
1578 liters - test chamber
External dimensions: width 1200 mm x depth 2270 mm x height 1985 mm
Internal dimensions: width 1000 mm x depth 1025 mm x height 1540 mm
Characteristic values for temperature tests
Temperature range -70°C to +180°C
Temperature deviation in time: ± 0.5 K
Spatial temperature deviation: ± 1.5 K
Heating speed according to DIN 50011 part 12: 2 K/min
Cooling rate according to DIN 50011 part 12: 1.5 K/min
Heat compensation
at 0°C: 1700 W
max. 2000 W
Characteristic values for climatic tests
Temperature range: + 10°C to +90°C
Temperature deviation in time: ± 0.3 K
Spatial temperature deviation: ± 1 K
Humidity range: 10 % to 98 % r.h.
Dew point range: + 5°C to 89.5°C
Humidity deviation over time: ± 1 to 3 % RH
Heat compensation
in the range from +25°C to +90°C,
at a relative humidity of > 90 %: 500 W
Humidification water consumption at
constant + 40°C and 92 % r.h. : < 3 L / 24 h
Data for installation and operation
Cooling water consumption at full load
(cooling water temperature +18°C and Δt=10 K) : approx. 1.2 m³/h
Weight: climatic test chamber: approx. 1000 kg
Nominal voltage: 400 V, +6/-10 %, 3/N, 50 Hz
Rated power: 8.6 kW
Rated current: 17 A
On-site fuse: 32 A slow-blow
RS232
Refrigerant R-404A and R23
Type: VC 7150
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: second-hand / used
Scope of delivery: (see picture)
(Subject to changes and errors in the technical data and specifications!)
Listing

785 km
Climatic chamber
Espec EGNX12-6CWL
Call
Condition: good (used), Espec
Type: EGNX12-6CWL
Byiactp99M
Espec temperature and climate test chamber air-cooled
Temperature (and humidity) test chamber N series
Power supply:
AC 400/460 V 3-phase 50/60Hz 32A
Temperature range -70 to +180°C
Humidity range 10 to 95% r. H.
Temperature change rate
Heating 15 °K/min
Cooling 11 °K/min
Internal dimensions W x H x D in mm 600 x 750 x 850
External dimensions W x H x D in mm 889 x 2098 x 1768
Useful volume 380 l
Refrigerant R404A
Weight: 370 kg
The following information is for your safety as a buyer!
The following points are carried out on our chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Temperature and climatic chamber
Heraeus VötschVC 350 LAF/S
Call
Condition: excellent (used), Here we offer a Heraeus Vötsch temperature and climate test chamber.
Heraeus Vötsch temperature and climate test chamber with Simcon/32-NET controller
and Hyfra cooling water recooler table-top unit VWK/1
TECHNICAL DATA :
General specifications:
Test chamber capacity: approx. 345 l
Weight: 375 kg
Data for mechanical stress:
maximum total load of the test chamber floor 60 kg
of which weighing stone 45 kg
Scales + test material approx. 15 kg
Storage shelves 3 kg
Permissible load per shelf approx. 100 g
Data for operation:
RS 232 interface
The RS 232 interface is used, for example, for external control via computer.
Lighting Operating instructions Safety cabinet
Interference emission; interference immunity Standards met see Declaration of Conformity
Nominal voltage 3/N / PE AC 400 V ± 10% 50 Hz
Rated power 5 kW
Rated current 9 A
Customer-side fuse 16A slow-blow
Noise measurement:
Sound pressure level measured at a distance of 1 m from the front,
1m height and free-field measurement approx. 58 dB(A)
Data for temperature tests:
Temperature +20 to +30 °C
Temperature fluctuation over time in the middle of the usable space ± 1 K
Heat compensation 100 W
Data for climate tests:
Data for humidification system
Water tank capacity approx. 10 l
Water quality demineralized
pH value 6 - 7
Conductivity max. 10 μs/cm
Temperature +20 to +30 °C
Bcskrottth
Humidity 30 to 70 % r.h.
Dew point +9.5 °C / +21 °C
Temperature fluctuation over time
in the middle of the usable space
(in steady state, according to IEC 60068-3-5)
± 3 K
Type: VC 350 LAF/S
Hyfra cooling water recooler table-top unit VWK/1
Plug-in units in air-cooled design.
Cooling capacities from 0.8 to 3.5 kW
Technical data for small appliances in table-top design VWK 7/1-S
Cooling capacity 814W
Air flow rate 500 m 3/h
Pump type LNY 2841
Compressor output 0.27 kW
Connected load 0.58 kW
Maximum current consumption 6.2 A
Maximum back-up fuse 10 A
Current type 1/N/PE ~ 50 Hz 230 V
Control voltage 230 V / 50 Hz
Tank capacity 6 liters
Water connection Plug-in couplings 6 and 9 mm
Fully hermetic design
Cooling type air-cooled
Length 565 mm , width 440 mm , height 335 mm
Type: VWK 7/1-S
Scope of delivery. (See pictures)
(We reserve the right to make changes and errors in the technical data).
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Climatic chamber -70°C to +100°C Humidity
ACS AngelantoniModell UD 500 C 500 Liter
Call
Condition: excellent (used), Here we offer an ACS climatic chamber.
ACS Angelantoni climatic chamber water cooled
Capacity: 500 liters
External dimensions: Width 1230 mm x Height 2350 mm x Depth 2600 mm
Interior dimensions: Width 815 mm x height 910 mm x depth 800 mm
Temperature range: -70°C to +100°C
Humidity range 20% to 95% rel. humidity
Icwcilltv
Connection: 400 V / 3 +N+T 50 Hz
Power consumption: max. 20 kW
(new vacuum pump mounted)
Weight: 2000 kg
Refrigerant: R404a / R23
Type: ACS UD 500 C
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

785 km
Climatic chamber
Weiss WK111-180
Call
Condition: good (used), White
Type: WK111-180
Weiss climatic test chamber air-cooled
Test chamber dimensions: Height 750 mm Width 580 mm Depth 450 mm
External dimensions: Height 1750 mm Width 870 mm Depth 1155 mm
Entry port built into basic equipment
R1: NW 125 mm
L1: NW 50 mm
Characteristic values for temperature tests:
Temperature range: -10 to +90°C
Temperature fluctuation in time ± 0.1 to ± 0.5 K
Spatial temperature deviation ± 0.5 to ± 1 K
(corresponds to temperature gradient) 1 to 2 K
Temperature change rate
Heating 0.6 K/min
Cooling 0.3 K/min
Characteristic values for Klimma test:
Temperature range + 10 to + 90°C
Humidity range:
relative humidity 10 to 98 %r.H.
Temperature fluctuation in time in the middle of the usable space ± 0.1 to ± 0.3 K
Spatial temperature deviation ± 0.5 to ± 1 K
(corresponds to temperature gradient) 1 to 2 K
Dpfzsj
Humidity fluctuation over time ± 1 to ± 3 %RH
Test room lighting: Halogen bulb 24 V, 50 W
Nominal voltage: 400V +6/-10% 3/N 50 Hz
Rated power: 2.3 kW Rated current: 10 A
Fuse on site 16A slow-blow
Refrigerant: R 404A
Test chamber capacity: approx. 180 liters
Weight: approx. 380 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Climatic chamber
VötschVCS 7033
Call
Condition: excellent (used), Heraeus Vötsch climatic chamber
Here we offer you a Heraeus Vötsch climatic chamber.
Vötsch climatic chamber VCS 7033 water cooled
Temperature range: -70°C to +180°C
Temperature change rate:
Heating 7.5 K/min.
Bfzmwmm2Ort
Cooling 6,5 K/min.
Humidity range: 10% to 98% r.H.
Temperature deviation temporal ± 0.5 K
Temperature deviation time-related ± 1.5 K
Test chamber dimensions: Width 675 mm x Depth 650 mm x Height 760 mm
Housing dimensions: Width 930 mm x depth 1565 mm x height 1840 mm
Lateral feedthrough 90mm ∅
approx. 330 L Weight: 600 kg
voltage: 3/N/PE AC 400V ±6/-10% 50Hz
rated power 9,5 kW
Rated current 17 A
Refrigerant R404A / R23
Type: VCS 7033
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

785 km
Climatic chamber
VötschVC³ 4100
Call
Condition: excellent (used), Vötsch climatic test chamber
Here we offer a Vötsch climatic test chamber.
Designation VC³ 4100 Air-cooled
With temperature change rate of 3 K/min
Test chamber dimensions: Height 950 mm x width 1100 mm x depth 950 mm
Unit dimensions: Height 2000 mm x width 1300 mm x depth 1916 mm
Volume: 990 liters
Feed-through: Ø 125 mm Ø 50 mm
Pggg3O2
Data for temperature tests:
Temperature range -42°C to +180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature homogeneity in space ± 0.5 to ± 1.5 K
Temperature change rate:
Heating 4.0 K/min
Cooling 3.0 K/min
Max. heat compensation at +20°C 4500 watts
Data for climate tests
Temperature range +10°C to +95°C
Dew point range -3°C to +94°C
Humidity range 10 to 98% r. h.
Temperature deviation temporal ± 0.1 to ± 0.3 K
Temperature homogeneity in space ± 0.5 to ± 1.0 K
Humidity deviation temporal ± 1 to ± 3% r. h.
Heat compensation max. 500 W
Voltage: 3/N/PE AC 400V ± 10% 50Hz
Rated power: 11.5 kW
Nominal current: 22.0 A
Refrigerant: R-404 A
Weight approx. 840 kg
Type: VC³ 4100
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Climatic chamber
RS Simulatoren
Call
Condition: excellent (used), RS Simulators
Jifhczr
Here we offer a climatic test chamber.
Water cooled
300 liters
Temperature range from -75 °C to +180 °C
Time deviation +- 0.2 K to +- 0.8 K
Average heating rate: approx. 2.1 K/min
Average cooling rate: approx. 1.2 K/min
Humidity range from 10 % to 98 % rel. humidity
Working climate range
Temperature: 10 °C to 95 °C
Humidity: 25 % to 75 % relative humidity
Dimensions: Width 1000 mm 1800 Height mm 1400 Depth mm
Voltage: 3x400V/N/PE Current: 40A
Refrigerant: R404a / R23
Type: KS 300 / 75
Weight: 630 kg
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See pictures)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

785 km
Climatic test chamber
Feutron 3702/06
Call
Condition: excellent (used), Feutron
Type: 3702/06
Water-cooled climatic test chamber
Technical data:
Test chamber nominal volume 2.0 m³
Dimensions: Test chamber exterior, with humidifier console
Width 2970 mm Height 2370 mm Depth 1530 mm
Jlzgopn
Rear wall
Minimum insertion dimensions: Width 2970 mm Height 2390 mm Depth 1550 mm
Test chamber: Width 2000 mm Height 1000 mm Depth 1000 mm
Double-leaf door, clear width Width 2000 mm Height 1000 mm
Heated viewing window, 2 pieces Width 500 mm Height 600 mm
Feed-through opening, 1 side panel left ∅ 75 mm
Temperature range: -40...100°C
Climatic range: 10...95°C
Temperature difference, temporal ≤ ± 0.5...± 1.0 ΔN/K
Change rates measured in the supply air without load
Cooling up to 2.0 on average K/min
Heating up to 2.0 on average K/min
Humidity range: 10...95 %r. F.
Humidity difference, temporal ≤ ± 3.0 %r. F.
Dew point range, temporary down to -5... 95°C
Refrigeration system: water-cooled semi-hermetic Bitzer system
Refrigerant: R507 (Μ-Κ1)
Air conditioning and dryer refrigeration system air-cooled /hermetic system
Refrigerant: R134a (Μ.ΚΚ)
Power supply:
Electrical mains connection: 400V 3/N/PE.AC,50Hz
Mains plug: CEE 5-роlig, 32 A, with 5.0 m cable
Max. simultaneous power requirement 10.0 kW
Supply line fuse: 3x 25, Char, C A
Degree of protection IP20
Weight: 1300 kg
Condition: used
Scope of delivery: (see picture)
(Subject to changes and errors in the technical data and specifications)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Climatic chamber
Vötsch VCS 7034-5
Call
Condition: used, Vötsch
Type: VCS 7034-5
Jtpopwx
Water-cooled climatic test chamber
Test chamber capacity 335 liters
Performance for temperature tests
Temperature range -70 to +180°C
Temperature deviation in time K ±0.1 to ±0.5
Spatial temperature deviation K ±0.5 to ±2.0
Temperature gradient 1 to 4
Rate of change :
Cooling 6.7 K/min
Heating 6.8 K/min
Heat compensation at +20 °C 3000 W / at -20°C 3000 W
Temperature calibration values +23 °C and +80 °C
Performance for climate tests
Temperature range +10 to +95°C
Temperature deviation in time ±0.1 to ±0.3 K
Spatial temperature deviation ±0.5 to ±1.0 K
Temperature gradient 1 to 2 K
Humidity range 10 to 98%
Humidity deviation in time ±1 to ±3%
Dew point range -3 to +94°C
Heat compensation 400W
Climate calibration values +23 °C / 50 % r.h. and +95 °C / 50 % r.h.
Test chamber dimensions: Width 580mm Depth 765mm Height 750mm
External dimensions: Width 870mm Depth 1595mm Height 1775mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10kW
Rated current: 21 A
Sound pressure level: 64dB(A)
Cooling water consumption: 1.4m³/h
Refrigerant: R-404A / R-23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Climatic chamber 8m³ with humidity #1
EspecEWSH282-4CW -65°C bis 150°C
Call
Condition: excellent (used), Here we offer a temperature and climate test cabinet.
Water cooled
Temperature range: -65°C to 150°C
Temperature variation: ±1°C
Temperature gradient: ±2°C
Temperature change rate
heating: approx. 2.5K/min
Cooling: approx. 2.5K/min
Humidity range: 20 to 95& r.H.
Humidity variation: ±5% r.H.
Humidity gradient: ±5% r.H.
Dimensions
External dimensions: Width 2324 mm Depth 4006 mm Height 2889 mm
Internal dimensions: Width 1829 mm Depth 1829 mm Height 2388 mm
R03Hp
Volume: 8.0 m³
Weight: approx. 3.600 kg
Power supply: 400V, 3PH, 50HZ. (+5% / 10%)
Power consumption max.: 132A
Controller: Espec SCP-220
Refrigerant: R-404a and R-508b
Type: EWSH282-4CW
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

785 km
Climatic chamber
Vötsch VC³ 4100
Call
Condition: excellent (used), Vötsch climatic test chamber
Here we offer a Vötsch climate test chamber.
Designation VC³ 4100 Air-cooled
With temperature change rate of 3 K/min
Test chamber dimensions: Height 950 mm x width 1100 mm x depth 950 mm
Device dimensions: Height 2000 mm x width 1300 mm x depth 1916 mm
Volume: 990 liters
Feed-through: Ø 125 mm Ø 50 mm
Data for temperature tests:
Temperature range -42°C to +180°C
Temperature deviation in time ± 0.1 to ± 0.5 K
Temperature homogeneity in space ± 0.5 to ± 1.5 K
Rate of temperature change:
Heating 4.0 K/min
Cooling 3.0 K/min
max. heat compensation at +20°C 4500 Watt
Data for climate tests
Temperature range +10°C to +95°C
Dew point range -3°C to +94°C
Humidity range 10 to 98% r. h.
Temperature deviation temporal ± 0.1 to ± 0.3 K
Spatial temperature homogeneity ± 0.5 to ± 1.0 K
Humidity deviation temporal ± 1 to ± 3% r. h.
Bh0Dadtm09K
Heat compensation max. 500 W
Voltage: 3/N/PE AC 400V ± 10% 50Hz
Rated power: 11.5 kW
Rated current: 22.0 A
Refrigerant: R-404 A
Weight approx. 840 kg
Type: VC³ 4100
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after a successful check, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Trust Seal
Through Machineseeker certified dealers

Listing

785 km
Climatic test chamber -40 to +180°C
WeissWK-480/40/10 480 Liter m. Feuchte
Call
Condition: excellent (used), Here we offer a Weiss climatic test chamber.
Water-cooled
Test chamber lighting Halogen bulb 24V, 50W
Data for temperature tests:
Temperature range: -40°C to +180°C
Temporal temperature deviation in the center of the chamber: ± 0.3 to ± 0.8 K
Spatial temperature deviation: ± 0.5 to ± 2 K
Temperature change rate
Heating: 10 K/min
Cooling: 12.5 K/min
Heat compensation at +20°C 8000 W
Heat compensation at -20°C 3000 W
Data for climate tests
Temperature range: +10°C to +95°C
Humidity range: 10 to 98 % r.h.
Temperature deviation in time in the center of the usable space: ± 0.2 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1 K
Humidity fluctuation over time in the center of the usable space: ± 1 to ± 3 % RH
Test chamber dimensions: Height 950 mm, width 760 mm, depth 650 mm,
External dimensions: Height 2025 mm, width 1090 mm, depth 2480 mm,
Nominal voltage: 3/N/PE AC 400 V ± 10% 50 Hz
Rated current: 24 A Rated power: 16.0 KW
Refrigerant: R452A
Weight: approx. 900 kg
Type: WK-480/40/10
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
C9Zpuvu
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Climatic chamber
WeissWk-340/40
Call
Condition: excellent (used), White
Type: WK - 340/40
Air-cooled
converted to R-452A
Test chamber capacity 335 approx. liters
Test chamber dimensions Height 750 mm Width 580 mm Depth 765 mm
External dimensions Height 1805 mm Width 780 mm Depth 1700 mm
Characteristic values for temperature tests:
Temperature range -40 to +180°C
Temperature fluctuation in time ± 0.1 to ± 0.5 K
Temperature fluctuation in space ± 0.5 to ± 2.0 K
Temperature change rate heating 3.2 K/min
Temperature change rate cooling 3.5 K/min
Characteristic values for climate tests:
Temperature range +10 to +95°C
Humidity range 10 to 98 %r.H
Temperature fluctuation
temporal ± 0.1 to ± 0.3 K
spatial ± 0.5 to ± 1 K
Humidity fluctuation in the center of the usable space ± 1 to ± 3 %r.H.
Electrical connection 3/N/PE AC, 400 V ±10 %, 50 Hz
Connected load approx. 4.1 kW
Rated current 12.5 A
Sound pressure level approx. 58 dB(A)
Weight 490 kg
Refrigerant: R-452A / R23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Iswe90E
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Climatic chamber
Vötsch VC³ 4018
Call
Condition: used, Vötsch
Type: VC³ 4018
Vötsch climate test chamber VC³ 4018 air-cooled
Technical data:
Test room dimensions: width 580 mm x depth 450 mm x height 750 mm
Housing dimensions: width 870 mm x depth 1550 mm x height 1800 mm
Test room volume: 190 liters
Implementation built into basic equipment
R1: ® 125 mm
L1: © 50 mm
Data for temperature tests:
Temperature range: -40°C to +180°C
Temperature deviation in time ± 0.1 to ± 0.5 K
Temperature homogeneity in space ± 0.5 to ± 1.5 K
Temperature change rate
Heating 4 K/min
Cooling 4 K/min
Max. Heat compensation 2300 W
Bnd8Jbwqui
Data for climate tests:
Temperature range + 10 to +95 °C
Dew point range -3 to +94 °C
Humidity range 10 to 98 %r.h.
Temperature deviation over time ± 0.1 to ± 0.3 K
Temperature homogeneity in space ± 0.5 to ± 1 K
Humidity deviation over time ± 1 to ± 3 %r.h.
Heat compensation 400 W
Data for operation:
Test room lighting halogen bulb 2 x 24V, 50W
3/N/PE AC 400V±10% 50 Hz
Rated power 4.1 kW
Rated current 14 A
Weight: 470 kg
For your safety as a buyer, the following information! The following points are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing

785 km
Climatic test chamber 190 liters with humidity
VötschVC³ 4018 -40°C bis +180°C
Call
Condition: excellent (used), Vötsch
Type: VC³ 4018
Vötsch climate test chamber VC³ 4018 air-cooled
Technical data:
Test room dimensions: width 580 mm x depth 450 mm x height 750 mm
Housing dimensions: width 870 mm x depth 1550 mm x height 1800 mm
Test room volume: 190 liters
Implementation built into basic equipment
R1: ® 125 mm
L1: © 50 mm
Data for temperature tests:
Temperature range: -40°C to +180°C
Temperature deviation in time ± 0.1 to ± 0.5 K
Temperature homogeneity in space ± 0.5 to ± 1.5 K
Temperature change rate
Heating 4 K/min
Cooling 4 K/min
max. heat compensation 2300 W
Data for climate tests:
Temperature range + 10 to +95 °C
Dew point range -3 to +94 °C
Humidity range 10 to 98 %r.h.
Temperature deviation over time ± 0.1 to ± 0.3 K
Temperature homogeneity spatial ± 0.5 to ± K
Humidity deviation over time ± 1 to ± 3 %r.h.
Heat compensation 400 W
Data for operation:
Test room lighting halogen bulb 2 x 24V, 50W
3/N/PE AC 400V±10% 50 Hz
Rated power 4.1 kW
Dqyicl
Rated current 14 A
Weight: 470 kg
For your safety as a buyer, the following information! The following points are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
We make it easier for you to find: "climatic chamber"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Climatic Chamber (5,272)
Search Machineseeker now with more than 200,000 used machines:This may be of interest to you

Find out now
+44 20 806 810 84
+44 20 806 810 84
Create listing
*per listing / month