Climate test chamber Temp. -70°C to +180°CVötsch 190 Liter
VCS 7018-5
Climate test chamber Temp. -70°C to +180°C
Vötsch 190 Liter
VCS 7018-5
Condition
Used
Location
Borken 

Show images
Show map
Machine data
- Machine type:
- Climate test chamber Temp. -70°C to +180°C
- Manufacturer:
- Vötsch 190 Liter
- Model:
- VCS 7018-5
- Condition:
- excellent (used)
Price & Location
- Location:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Call
Details about the offer
- Listing ID:
- A18736216
- Reference number:
- 24557
- Update:
- 26.06.2025
Description
Heraeus Vötsch
Type: VCS 7018-5
Climatic Test Chamber with Humidity Control, Water-Cooled
Test Chamber Dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing Dimensions: Width 870 mm x Depth 1280 mm x Height 1775 mm
Characteristics for Temperature Tests:
Temperature Range: -70°C to +180°C
Temperature Range: ± 0.1 to ± 0.5 K
Spatial Range: ± 0.5 to ± 2.0 K
Temperature Gradient: 1 to 4 K
Temperature Rate of Change according to IEC 60068-3-5
Heating: 7.5 K/min
Cooling: 7.5 K/min
Characteristic values for climatic tests:
Temperature range +10 to +95°C
Humidity range: 10 to 98% RH
Temperature deviation over time: ± 0.1 to ± 0.3 K
Nsdpfx Aaov N Hc Esceku
Temperature deviation over space: ± 0.5 to ± 1 K
Temperature gradient: 1 to 2 K
Humidity fluctuation over time: ± 1 to ± 3% RH F.
Dew point range -3 to +94 °C
Electrical connection:
Nominal voltage: 3/N/PE AC 400V±10% 50Hz
Nominal power: 10 kW
Nominal current: 21 A
Fuse protection: 32 A slow-blow, provided by the customer
Refrigerant: R-404A / R-23
Test chamber volume: approx. 190 liters
Weight: approx. 460 kg
For your safety, please note the following information!
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications!)
We are happy to answer any further questions you may have over the phone.
The listing was translated automatically. Translation errors are possible.
Type: VCS 7018-5
Climatic Test Chamber with Humidity Control, Water-Cooled
Test Chamber Dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing Dimensions: Width 870 mm x Depth 1280 mm x Height 1775 mm
Characteristics for Temperature Tests:
Temperature Range: -70°C to +180°C
Temperature Range: ± 0.1 to ± 0.5 K
Spatial Range: ± 0.5 to ± 2.0 K
Temperature Gradient: 1 to 4 K
Temperature Rate of Change according to IEC 60068-3-5
Heating: 7.5 K/min
Cooling: 7.5 K/min
Characteristic values for climatic tests:
Temperature range +10 to +95°C
Humidity range: 10 to 98% RH
Temperature deviation over time: ± 0.1 to ± 0.3 K
Nsdpfx Aaov N Hc Esceku
Temperature deviation over space: ± 0.5 to ± 1 K
Temperature gradient: 1 to 2 K
Humidity fluctuation over time: ± 1 to ± 3% RH F.
Dew point range -3 to +94 °C
Electrical connection:
Nominal voltage: 3/N/PE AC 400V±10% 50Hz
Nominal power: 10 kW
Nominal current: 21 A
Fuse protection: 32 A slow-blow, provided by the customer
Refrigerant: R-404A / R-23
Test chamber volume: approx. 190 liters
Weight: approx. 460 kg
For your safety, please note the following information!
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications!)
We are happy to answer any further questions you may have over the phone.
The listing was translated automatically. Translation errors are possible.
Seller
Note: Register for free or log in, to access all information.
Registered since: 2012
Send inquiry
Telephone & Fax
+49 2861 ... show
These listings may also fit your interest.
Listing
Enschede
764 km
Plate shear
OstasORGM 1050 x 6
OstasORGM 1050 x 6
Listing
Borken
785 km
Salt spray chamber
WeissSC/KWT 450
WeissSC/KWT 450
Listing
Borken
785 km
Climate test chamber with humidity
WeissSB2/500/80 -75°C bis +180°C
WeissSB2/500/80 -75°C bis +180°C
Listing
Borken
785 km
Climate chamber
CTSC-40/200
CTSC-40/200
Listing
Germany
1,137 km
Plate Shear - Mechanical
Stückmann&Hillen16505
Stückmann&Hillen16505
Listing
Borken
785 km
Corrosion test cabinet for salt spray
VLMCC 1000-FL HL V.745.672.120
VLMCC 1000-FL HL V.745.672.120
Listing
Tatabánya
1,738 km
CORROSION CHAMBER LIEBISCH
LIEBISCH Salzsprühnebel-Korrosionstest(2458)
LIEBISCH Salzsprühnebel-Korrosionstest(2458)
Listing
Wiefelstede
785 km
Guillotine
unbekanntSchnittbreite 1030 mm
unbekanntSchnittbreite 1030 mm
Listing
Ahaus
779 km
Plate Shear - Mechanical
RAS52.7
RAS52.7
Listing
Borken
785 km
Climate test chamber with humidity
Weiss -72°C bis +180°CWK3-340/70
Weiss -72°C bis +180°CWK3-340/70
Your listing has been deleted successfully
An error has occurred