Description
Weiss
Type: WT3-600/40
Weiss temperature testing chamber with S!MCON / 32 control system, water-cooled
Control panel »Touchpanel«
All control and operating commands can be initiated on the »Touchpanel« control panel by simply touching the function symbols.
Adjustable feet
To compensate for uneven floors and to ensure adequate ventilation of the machine, the testing chamber is equipped with adjustable feet.
Feedthroughs
The testing chamber is equipped with feedthroughs on the right and left sides.
These allow measuring cables and testing equipment to be routed into the test chamber.
Feedthroughs installed as standard
R1: NW 125 mm
L1: NW 50 mm
(Refrigerant converted to R-452A)
Test chamber volume: approx. 600 liters
External dimensions with hinges and door lock
Height 1995 mm, Width 1090 mm, Depth 1660 mm
External dimensions without hinges and door lock
Height 1995 mm, Width 1000 mm, Depth 1660 mm
Internal dimensions: Height 950 mm, Width 800 mm, Depth 800 mm
Data for temperature tests:
Temperature range: -42 to +180 °C
Gsdpfx Aoziyb Reg Tsuh
Temporal temperature deviation in the center of the usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate (according to IEC 60068-3-5)
Heating: 4.0 K/min
Cooling: 3.0 K/min
Maximum heat compensation: 2500 W
Data for operation:
Test chamber lighting: Halogen bulb 2 x 24V, 50W
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated current: 15 A, Rated power 7.8 kW
Fuse: 16 A slow-blow (supplied by customer)
Sound pressure level approx.
measured at a distance of 1 m from the front, 1 m height: 58 dB(A)
Refrigerant: R-452A
Weight: 620 kg
For your safety as a buyer, the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We would be happy to answer any further questions you may have by phone.
The listing was translated automatically. Translation errors are possible.
Type: WT3-600/40
Weiss temperature testing chamber with S!MCON / 32 control system, water-cooled
Control panel »Touchpanel«
All control and operating commands can be initiated on the »Touchpanel« control panel by simply touching the function symbols.
Adjustable feet
To compensate for uneven floors and to ensure adequate ventilation of the machine, the testing chamber is equipped with adjustable feet.
Feedthroughs
The testing chamber is equipped with feedthroughs on the right and left sides.
These allow measuring cables and testing equipment to be routed into the test chamber.
Feedthroughs installed as standard
R1: NW 125 mm
L1: NW 50 mm
(Refrigerant converted to R-452A)
Test chamber volume: approx. 600 liters
External dimensions with hinges and door lock
Height 1995 mm, Width 1090 mm, Depth 1660 mm
External dimensions without hinges and door lock
Height 1995 mm, Width 1000 mm, Depth 1660 mm
Internal dimensions: Height 950 mm, Width 800 mm, Depth 800 mm
Data for temperature tests:
Temperature range: -42 to +180 °C
Gsdpfx Aoziyb Reg Tsuh
Temporal temperature deviation in the center of the usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate (according to IEC 60068-3-5)
Heating: 4.0 K/min
Cooling: 3.0 K/min
Maximum heat compensation: 2500 W
Data for operation:
Test chamber lighting: Halogen bulb 2 x 24V, 50W
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated current: 15 A, Rated power 7.8 kW
Fuse: 16 A slow-blow (supplied by customer)
Sound pressure level approx.
measured at a distance of 1 m from the front, 1 m height: 58 dB(A)
Refrigerant: R-452A
Weight: 620 kg
For your safety as a buyer, the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We would be happy to answer any further questions you may have by phone.
The listing was translated automatically. Translation errors are possible.
Send inquiry
Telephone & Fax
+49 2861 ... show
These listings may also fit your interest.
Success:
Your message has been sent.
Listing
Borken
785 km
Weiss temperature chamber WT3-1000/40, 990 liters, temperature range -40°C to +180°C
WeissWeiss Temperaturprüfschrank
WeissWeiss Temperaturprüfschrank
Success:
Your message has been sent.
Listing
Hohenthann
1,295 km
Telehandler 810 T Kubota
Kingway810 T Kubota
Kingway810 T Kubota
Success:
Your message has been sent.
Listing
Borken
785 km
Weiss temperature chamber WT3-340/40, 335 liters, temperature range -42°C to +180°C
WeissWeiss Temperaturprüfschrank
WeissWeiss Temperaturprüfschrank
Success:
Your message has been sent.
Listing
Borken
785 km
Weiss Temperature Test Chamber WT3-600/40, 600 liters, -42°C to +180°C
WeissWeiss Temperaturprüfschrank
WeissWeiss Temperaturprüfschrank
Success:
Your message has been sent.
Listing
Chemnitz
1,203 km
Tipping body with various rear configurations
Container-Vertrieb-ChemnitzGaLa-Bau Container Kippaufbau
Container-Vertrieb-ChemnitzGaLa-Bau Container Kippaufbau
Your listing has been deleted successfully
An error has occurred