Used Measuring & testing equipment for sale (1,321)
Sort results
- Lowest price Highest price
- Latest listings Oldest listings
- Shortest distance Farthest distance
- Latest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Latest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Latest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation A to Z
- Designation
- designation Z to A
- Designation
- Model A to Z
- Model
- Model Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest running time
- Runtime
- Relevance
- Relevance
Listing

785 km
Climate test chamber with humidity
WeissSB2/500/80 -75°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss climate test chamber.
Debvq Rom Tvzcoxrjcg
Designation: SB2/500/80 water cooled
Cold-heat operation: -75°C ...+180°C
Climatic operation: +10...+95°C
Humidity range: 10...98 % r. h.
Temperature constancy, temporally ± 0.2K
Humidity constancy: ±1 r.F.
Temperature rate of change:
Cooling: approx. 1.4 K/min
Heating up: approx. 2.5 K/min
External dimensions: Height 1980 mm, width 1265 mm, depth 1365 mm
Feedthroughs:
left side: ∅ 100 mm
right side: ∅ 50 mm
The connection voltage is:
400V/3Ph+N+PE/ 50 Hz
Power: 10,4 kVA
Weight: approx. 720 kg
Refrigerant R404a / R 23
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Type: SB2/500/80
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

785 km
Temperature test chamber 600 liters
WeissWT3-600/40 -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss temperature chamber.
Weiss temperature test chamber With S!MCON / 32 control unit Water-cooled
Touch panel" control unit
All control and operating commands can be triggered on the "touch panel" control unit by simply touching the
all control and operating commands by simply touching the function icons.
Levelling feet
To compensate for uneven floors and to ensure adequate ventilation of the machine part,
the test chamber is equipped with adjustable feet.
Feed-throughs
The test chamber is equipped with feed-throughs on the right and left side.
Measuring cables and test equipment can be routed through these into the test chamber.
Feed-through built into basic equipment
R1: NW 125 mm
L1: NW 50 mm
(refrigerant converted to R-452A)
Test chamber capacity: approx. 600 liters
External dimensions with hinges and door lock
Height 1995 mm, width 1090 mm, depth 1660 mm
External dimensions without hinges and door lock
Height 1995 mm, width 1000 mm, depth 1660 mm
Internal dimensions: Height 950 mm, width 800 mm, depth 800 mm
Data for temperature tests:
Temperature range: -42 to +180 °C
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate (according to IEC 60068-3-5)
Heating: 4.0 K/min
Cooling: 3.0 K/min
Heat compensation max. 2500 W
Data for operation:
Test room lighting Halogen bulb 2 x 24V, 50W
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Rated current: 15 A Rated power 7.8 kW
On-site fuse 16 A slow-blow
Sound pressure level approx.
measured at a distance of 1m from the front. 1m height 58 dB(A)
Refrigerant: R-452A
Weight: 620 kg
Type: WT3-600/40
The following information is for your safety as a buyer!
Dobsrak Rmsvq Rxrecg
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Temperature test chamber 600 liters
WeissWT3-600/40 -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss temperature chamber.
Weiss temperature test chamber With S!MCON / 32 control Air-cooled
(refrigerant converted to R-452A)
Touch panel" control unit
All control and operating commands can be triggered on the "touch panel" control unit by simply touching the function icons.
all control and operating commands by simply touching the function icons.
Levelling feet
To compensate for uneven floors and to ensure adequate ventilation of the machine part,
the test chamber is equipped with adjustable feet.
Feed-throughs
The test chamber is equipped with feed-throughs on the right and left side.
Measuring cables and test equipment can be routed through these into the test chamber.
Feed-through built into basic equipment
R1: NW 125 mm
L1: NW 50 mm
Test chamber capacity: approx. 600 liters
External dimensions with hinges and door lock
Height 1995 mm, width 1090 mm, depth 1660 mm
External dimensions without hinges and door lock
Dsbvq Rerak S Dexrjcg
Height 1995 mm, width 1000 mm, depth 1660 mm
Internal dimensions: Height 950 mm, width 800 mm, depth 800 mm
Data for temperature tests:
Temperature range: -42 to +180 °C
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate (according to IEC 60068-3-5)
Heating: 4.0 K/min
Cooling: 3.0 K/min
Heat compensation max. 2500 W
Data for operation:
Test room lighting Halogen bulb 2 x 24V, 50W
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Rated current: 15 A Rated power 7.8 kW
On-site fuse 16 A slow-blow
Sound pressure level approx.
measured at a distance of 1m from the front. 1m height 61 dB(A)
Refrigerant: R-452A
Weight: 620 kg
Type: WT3-600/40
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.

Find out now
+44 20 806 810 84
+44 20 806 810 84
Create listing
*per listing / month
Listing

785 km
Measuring system
Heinzinger ERS 600-500/160
Call
Condition: good (used), Heinzinger
Here we offer you a battery module tester.
Description:
Highly dynamic test bench energy system
Bidirectional DC power supply with active energy recovery, liquid-cooled
Voltage [max]: 20 - 600 V adjustable
Current [max]: ± 500 A adjustable
System power [max]: ± 160,000 W
Mains connection (3/N/PE): 3x400V ±10% 47 ... 63Hz
Software: Battery simulation software for load change-optimized control
Dimensions (W/H/D): 1800/2330/800 mm
Type: ERS 600-500/160
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information are subject to change!)
Dcebvqeq Nzwae Rxrjg
We will be happy to answer any further questions you may have over the phone.
Listing

785 km
Test chamber for parametric test
S & A-55°C bis +200°C 4365A
Call
Condition: good (used), Here we offer you a S & A test chamber for parametric testing.
Temperature range
-55 ° C to 200 ° C (LCO2)
-65 ° C to 200 ° C (LN2)
Temperature change rate
15° C / min (Standard Option)
60° C / min (Fast Option)
Dcjbvq Rocnic Dexrjg
Stability
± 0.2 ° C (including effects of mains voltage, ambient temperature between
between 15° and 45° C and aging)
Uniformity
± 1.0 ° C Max from -65 ° C to -55 ° C
± 0.5 ° C Max from -55 ° C to + 125 ° C
± 1,0 ° C Max from + 125 ° C to + 200 º C
Coolant: LCO2
Chamber can be controlled remotely via IEEE bus or
RS232C interface
Weight approx. 61 kg
Type: 4365A
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, details are reserved!)
Further questions we can answer gladly on the phone for you.
Listing

785 km
Oven
VötschNTU 60/60
Call
Year of construction: 1996, Condition: good (used), Here we offer a Voetsch drying oven Waermeschrank Waermeofen.
Voetsch NTU 60/60 250°C
Nominal temperature: 250°C
Supply voltage:
400 V 3 (N) PE AC, 50/60 Hz
Debvq Rxebqh I Sjrscg
Interior dimensions: width 600 mm/height 600 mm/depth 600 mm
External dimensions: width 1000 mm/height 1675 mm/depth 1300 mm
Air circulation blower
Type: Voetsch NTU 60/60
Scope of delivery: (see picture)
(Changes and errors in the technical data are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Temperature test chamber
Feutron TPK 200 Typ: 3416/17
Call
Condition: excellent (used), Feutron temperature test chamber
Here we offer a temperature test chamber.
Feutron temperature test chamber air-cooled
Nominal test chamber volume: 280 liters
dimensions
Dsbok Scxmjvq Rxrecg
Test chamber outside: 1500 x 2040 x 1075 mm
Fan motor and door dismantled: 1500 x 1940 x 925 mm
Test chamber: 720 x 690 x 560 mm
Door, clear width: 720 x 690 mm
Viewing window, heated: 500 x 600 mm
Temperature range
-70°C to +180°C
Heating: 4.0 K /min
Cooling: 0.6 K /min
Mains connection: 400 V 3/N/PE, AC, 50 Hz
Max. power requirement: 6.3 kW
Weight: 600 kg
Type: 3416/17
Refrigerant: R507 / R23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Temperature cabinet 110 liters
VötschVT 7011 -70°C bis +180°C
Call
Condition: excellent (used), Here we offer a Heraeus Vötsch temperature cabinet.
Heraeus Vötsch temperature chamber water cooled
Test chamber volume 110 liters
Dobvq Rxshrdy Sjrjcg
Test chamber dimensions: Width 560 mm Depth 350 mm Height 630 mm
Outer dimensions: Width 850 mm Depth 1030 mm Height 1640 mm
Temperature range - 70°C to +180°C
Temperature deviation in time ±0.1 to ±0.5 K
Temperature deviation spatial ±0.5 to ±1.5 K
Temperature gradient 1 to 3 K
Temperature change rate cooling 3.2 K/min
Temperature change rate heating 3,5 K/min
Refrigerant: R-404 A / R 23
Voltage 1/N/PE AC 230V±10% 50Hz
Rated power 1,8 kW
Rated current 12 A
Type: VT 7011
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

785 km
48V belt starter generator test bench
KübrichKomponentenprüfstand
Call
Condition: excellent (used), Kübrich
Kübrich test systems 48V belt starter generator - component test bench
Details of the test stand: (see Fig. 13)
Frame with
(1) Mounting device for a belt starter generator
(2) Load machine
(3) Belt
(4) MP1: Switch cabinet
Dobvq Reumv Emoxrecg
(5) MP3: Control cabinet for the control system, transfer plate with main switch, I/O
(6) MP2: Switch cabinet with Simotion
(7) MP4: Switch cabinet with DC-DC converter
(8) H3: Measurement technology box
(9) H4: Transfer box
Intended use:
The test stand is used to carry out tests on belt starter generators during development.
Technical data:
Electrical connection data
Power supply: 400 V / 32 A
Battery simulation: 0 - 60 V
Current: 0 - 250 A (continuous)
Current intensity: 330 A (short term, less than 1 s)
Control voltage 24 V
Mechanical performance data according to the data sheet of the load machine
A transmission ratio of 1:2 to the test specimen shaft must be observed.
Speeds:
Load machine:
Set-up mode: 0 - 50 1/min
Automatic mode: 0 - 10 000 1/min
Test specimen motor:
Set-up mode: 0 - 100 1/min
Automatic mode: 0 - 20 000 1/min
Dimensions and weight
Width: 850 mm Height: 1386 mm Length: 1687 mm
Weight: approx. 1.2 t
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Shaker system
LDS V875-440 mit Verstärker SPA40K
Call
Condition: used, LDS
Type: V875 Shaker System V875-440 with amplifier SPA40K
Shaker for medium forces
Technical data:
Headexpander 850 * 850 mm
Armature dimensions: 440 mm
Dcebvq Rxeuxcpwjreg
Sinusoidal force vector 35.6 kN (peak)
Sine force vector 35.6 kN (effective)
Shock force vector 106.75 kN (peak)
Frequency range 5 to 3000 Hz
Test specimen mass max.600kg
Acceleration max. 1078.7 m/s²
Speed max. 1.8 m/s
Condition: gebraucht / used
Weight:
Shaker approx. 2200 kg
Blower: 181 kg
Amplifier: 622 kg
Scope of delivery: (See pictures)
(We reserve the right to make changes and errors in the technical data!)
We will be happy to answer any further questions you may have over the phone.
Listing

785 km
Climate cell
Tira TTZ 4008
Call
Condition: good (used), TIRA
Dcjbvq Rjuvil Soxrsg
Type: Walk-in climate simulation cell TTZ 4008 S(m)
Technical data:
Temperature range -40...+120 °C
Temperature tolerance: +/- 1.0°C
Temperature change rate: 1 K/min
Humidity range
10...approx. 95 % r.h.
Humidity tolerance
+/- 5.0 % r.h.
Dimensions:
Test chamber volume: 8m³
External dimensions (WxDxH) approx. 2410mm X 3920mm X 2530mm
Test chamber (WxDxH) approx. 2002mm Χ 2148mm Χ 2005mm
Door opening (WxH) approx. 2002mm X 2005mm
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Climate cell
RS SimulatorenKKC 22/45
Call
Condition: good (used), RS Simulators
Type: Walk-in climate simulation cell KKC 22/45
Technical data:
Temperature range -40...+120 °C
Temperature tolerance: +/- 1.5°C
Temperature change rate: 1 K/min
Humidity range
10...approx. 95 % r.h.
Humidity tolerance
+/- 5.0 % r.h.
Dcebeuviydovq Rxrjg
Dimensions:
Test chamber volume: 22m³
External dimensions (WxDxH) approx. 2600mm X 6400mm X 2800mm
Test chamber (WxDxH) approx. 2200mm Χ 4700mm Χ 2300mm
Door opening (WxH) approx. 2200mm X 2300mm
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Climate cell
RS SimulatorenKKC 22/45L
Call
Condition: good (used), RS Simulators
Type: Walk-in climate simulation cell KKC 22/45L
Technical data:
Temperature range -40...+120 °C
Temperature tolerance: +/- 1.5°C
Temperature change rate: 1 K/min
Humidity range
10...approx. 95 % r.h.
Humidity tolerance
+/- 5.0 % r.h.
Dimensions:
Test chamber volume: 22m³
External dimensions (WxDxH) approx. 2600mm X 6400mm X 2800mm
Test chamber (WxDxH) approx. 2200mm Χ 4700mm Χ 2300mm
Door opening (WxH) approx. 2200mm X 2300mm
Year of construction: 2009
Debvq Rxsuvi Nferscg
Technical data Sun simulation:
Control insert: Mitronic STB1-8
Number of lights: 8
Ballast: Mitronic CP2k5 - 2ZS
Ignitor: Hönle
Light source: OSRAM Powerstar HQI 2000W W/D/S
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Temperature test chamber 280 liters
FeutronTPK 200 Typ: 3416/17 -70°C bis +180°C
Call
Condition: excellent (used), Feutron
Type: 3416/17
Temperature test chamber Air-cooled
Test chamber nominal volume: 280 liters
Dimensions:
Test chamber outside: width 1540 mm x height 2090 mm x depth 1240 mm
Fan motor and door dismantled: width 1540 mm x height 1940 mm x depth 925 mm
Test chamber: width 720 mm x height 690 mm x depth 560 mm
Door, clear width: width 720 mm x height 690 mm
Viewing window, heated: width 500 mm x height 600 mm
Installation dimensions of the temperature test chamber with doors open
Width 2340 mm x height 2090 mm x depth 2165 mm
Through-hole 2 pieces side wall, left ∅ 100 mm
Dcjbveu E N Tisq Rxrog
Temperature range
-70°C to +180°C
Heating: 3.0 K /min
Cooling: 3.0 K /min
Mains connection: 400 V 3/N/PE, AC, 50 Hz
Max. power requirement: 6.3 kW
Weight: 635 kg
Refrigerant: R507 / R23
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
We will be happy to answer any further questions you may have over the phone.
Listing

785 km
Climate test chamber 990 liters
WeissWK-1000/70/5 -70°C bis +180°C
Call
Condition: excellent (used), White
Type: WK-1000/70/5
Weiss climatic test chamber with Weiss air-cooled condenser
S!MCON / 32 control unit
Test chamber capacity: approx. 990 liters
Test chamber dimensions: Height 950 mm, width 1100 mm, depth 950 mm,
External dimensions: Height 1980 mm, width 1385 mm, depth 1850 mm,
Data for operation:
Test room lighting Halogen bulb 24V, 50W
Nominal voltage: 3/N / PE AC 400 V ± 10% 50 Hz
Nominal power 26 KW
Rated current: 38 A
Data for temperature tests:
Temperature range: -70 to +180 °C
Temperature deviation in time in the center of the working space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 2 K
Temperature change rate
Heating: 6.5 K/min
Cooling: 6.0 K/min
Heat compensation max. 5000 W
Data for climate tests
Temperature range: +10 to +95 °C
Humidity range: 10 to 98 % r.h.
Temperature deviation in time in the middle of the usable space: ± 0.1 to ± 0.3 K
Spatial temperature deviation: ± 0.5 to ± 1 K
Humidity fluctuation over time in the center of the usable space: ± 1 to ± 3 % r.h.
Dimensions incl. feet
Width x depth x height: 1190 x 1120 x 1093 mm
Refrigerant: R404 A 11.0 kg
Refrigerant: R23 A 1.5 kg
Weight: approx. 910 kg
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Djbveu Ap Tkeq Rxrjcg
Listing

785 km
Climatic chamber
Espec EGNX12-6CWL
Call
Condition: good (used), Espec
Dcobst Nf Upovq Rxreg
Type: EGNX12-6CWL
Espec temperature and climate test chamber air-cooled
Temperature (and humidity) test chamber N series
Power supply:
AC 400/460 V 3-phase 50/60Hz 32A
Temperature range -70 to +180°C
Humidity range 10 to 95% r. H.
Temperature change rate
Heating 15 °K/min
Cooling 11 °K/min
Internal dimensions W x H x D in mm 600 x 750 x 850
External dimensions W x H x D in mm 889 x 2098 x 1768
Useful volume 380 l
Refrigerant R404A
Weight: 370 kg
The following information is for your safety as a buyer!
The following points are carried out on our chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Temperature shock test chamber
EspecTSD-100 -70 °C bis +200 °C
Call
Condition: excellent (used), Espec
Type: TSD-100
100 liters of usable space for larger test specimens up to 30 kg.
Complies with all current international standards.
Water-cooled
Temperature range hot chamber: +60 °C to +200 °C
Temperature range cold chamber: -70 °C to 0 °C
Test chamber dimensions: 710 x 345 x 410 (W x H x D) in mm
External dimensions: 1100 x 1885 x 1965 (W x H x D) in mm
Water-cooled refrigeration unit
Program control via touch panel
Automatic defrosting
Overtemperature protection
Dcjbvjub Tqnsq Rxrjg
Operating hours counter
Mobile version
2 stainless steel test baskets
Cable gland Ø 100 mm
Refrigerant: 3 kg R404A 1kg R23
Power supply: 400V 3Ph 50Hz
Max. Current consumption: 32A
Condition: gebraucht / used
Weight: 1100 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Shaker
LDSV721 / TK 8000/-50/120
Call
Condition: good (used), LDS + Andreas Schmid
Type: LDS Shaker V721 + TK 8000/-50/120 -55 to +140°C
Shaker:
Shaker 4x LDS V721 air-cooled
Amplifier : PA 1000L
Controller : imv K2 MIMO (Multi Input Multi Output)
Software : imv K2
Excitation modes : Sine / Noise / Shock / Real-time profiles
Force vector per shaker : 2.9 kN (peak sine) / 1.9 kN (RMS noise) / 4.6 kN (peak shock)
Max. load : 100 kg per shaker
Acceleration : max. 44 g RMS / 66 g peak
Velocity : max. 0.7 m/s
Displacement amplitude : max. 25.4 mm p-p (1 inch)
Dcobvq Rjur Hrbsxrjg
Frequency range : 5...4000 Hz
Clamping surface for test specimens : 1000 x 1000 mm aluminum profile frame
Special features :
The four shakers can be operated synchronously or asynchronously with the MIMO controller.
With an aluminum profile frame, a clamping area of 1x1 m² can be achieved for large test specimens.
Without the profile frame, mobile use as a modal shaker for large test specimens such as complete vehicles is possible.
The lightweight oscillating elements of the shakers enable excitation frequencies of up to 4000 Hz.
Weight: 2000 kg
Climatic chamber:
Manufacturer: Andreas Schmid Anlagentechnik GmbH
Type: TK 8.000/-50/120 / monoblock, welded
Dimensions:(mm): Width Depth Height
Test chamber: 2,000 2,000 2,000 (8m³)
External dimensions without base frame: 2,340 3,600 2,800
External dimensions with base frame: 2,340 3,600 3,800
External dimensions of power unit: 1,200 2,400 2,200
Door: 2,000 2,000
2 test room windows in the door: 460 460
Weight: 4,500 kg
Insulation 140 mm PU, CFC-free, B1 to DIN 4102
External cladding: sheet steel 0.6 mm, painted to RAK 7035
Temperature range: -55 °C to +140 °C
Temperature stability: ± 0.5 K temporal
Climatic range: +10 °C to +95 °C
Humidity range: 10% to 95% RH
Refrigerant R404A 29 kg
Total weight: 6500 kg
Condition: used
Scope of delivery: (see picture)
Example pictures! Actual pictures will follow!
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Temperature test chamber
VötschVTS 7034-5
Call
Condition: good (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch temperature test chamber water-cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in terms of time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6.5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
External dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Lateral feed-through 5.5 cm / 12.5 cm
Cabinet is water-cooled
Refrigerant: R- 404A and R 23
Weight approx. 570 kg
Dcsbvjun Izcjq Rxrsg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Temperature cabinet 110 liters
VötschVT 7011 -70°C bis +180°C
Call
Condition: used, Vötsch
Type: VT 7011
Heraeus Vötsch temperature chamber air-cooled
Test chamber volume 110 liters
Test chamber dimensions: Width 560 mm Depth 350 mm Height 630 mm
External dimensions: Width 850 mm Depth 1030 mm Height 1640 mm
Temperature range - 70°C to +180°C
Temperature deviation in time ±0.1 to ±0.5 K
Spatial temperature deviation ±0.5 to ±1.5 K
Temperature gradient 1 to 3 K
Temperature change rate cooling 3.2 K/min
Temperature change rate heating 3.5 K/min
Djbvq Rsvfddfjxrjcg
Refrigerant: R-404 A / R 23
Voltage 1/N/PE AC 230V±10% 50Hz
Nominal power 1.8 kW
Rated current 12 A
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Rheometer
Anton PaarPhysica MCR 101
Call
Condition: excellent (used), Anton Paar
Type: Physica MCR 101 Rheometer
Description:
Dsbvjubxh Sjq Rxrocg
The device is used for the rheological characterization of various substances.
Both tension and creep tests can be carried out.
Oscillatory and rotatory measurements can also be carried out.
There are various measuring geometries for characterizing low-viscosity
and highly viscous fluids as well as emulsions and suspensions.
There is also a device for DMTA analysis and
a measuring cell (biconus) for the characterization of interfaces.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Trust Seal
Dealers certified through Machineseeker

Listing

785 km
Climate test chamber 280 liters
FeutronKPK 200 Typ: 3416/16 +5 °C bis +100 °C
Call
Condition: excellent (used), Here we offer a climatic test chamber.
Air cooled
Nominal test chamber volume: 280 liters
Dimensions
Test chamber outside: 1500 x 2040 x 1075 mm
Fan motor and door disassembled: 1500 x 1940 x 925 mm
test chamber: 720 x 690 x 560 mm
door, clear width: 720 x 690 mm
viewing window, heated: 500 x 600 mm
Temperature range
+5 to +100 C
heating: 4,0 K /min
Cooling: 0.6 K /min
Climate range +10 to +95 C
Humidity range: 10 to 95 % r.H.
Humidity difference, temporal: ≤ ± 3.0
Water connection humidifier: city water or distilled water 20l reservoir tank.
Mains connection: 400 V 3/N/PE, AC, 50 Hz
Power requirement max : 6,3 kW
Weight : 500 Kg
Dsbvq Rxeiz Tqcjrecg
Type : 3416/16
Refrigerant : R134a
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

785 km
Climate test cell with humidity
Feutron3707/06 Temp. -40°C bis 150°C
Call
Condition: excellent (used), Here we offer a Feutron climate test cell.
Feutron climate test cell
Temperature
Temperature range: -40...90°C
Climatic range (without heat load) 10...85°C
Temperature difference,temporal during temperature operation ≤ ± 0.5 K/min.
Temperature difference,temporal at climatic operation ± 1,0... ± 1.5 K/min
Rate of change
Heating 2.0 on average K/min
Cooling 2,0 in average K/min
The IEC 1646 standard can be realized with testing, solar modules with max. 160kg weight and non-linear ramps.
(setpoint step change) can be realized
Drying
Air drying Condensation drying
Humidity
Humidification of air Steam humidification
Humidity range 10... 95 % r.h.
Humidity difference,temporal ≤ ± 3,0... ±5.0 %r.H.
Dew point range 8... 80,9 °C
Test room
Test room volume 7.0m³
Dimensions
Test room dimensions width 1500 mm x height 2250 mm x depth 2000 mm
Revolving door DIN right heated,i,l.. width 900 mm x height 2100 mm
Viewing window, heated with darkening flap and lockable Width 500 mm x height 600 mm
Feed-through opening 2x in front side right ∅ 75 mm
Irradiation unit test room
Cut-out 4x in side panel left for SC 2500 850 x 700 mm each
Area to be irradiated when using SC 2500 1200 x 1200 mm
Intensity of radiation at 1.0 m distance from wall 1000 ± 10% W/m²
Lighting 1xhalogen lamp 200W
Refrigeration system Bitzer compressor semi-hermetic 2-stage,air-cooled
Condenser: split condenser (outdoor installation winter control)
Refrigerant R507 /R23
Temperature control system
Cooling brine medium Tyfocor / water
Mixing ratio 50/50
Density of cooling brine 1,072 kg/dm³
Filling quantity approx. 80dm³
Pyranometer Temperature range -40... 150°C
Max. Radiation absorption 4000 W/m²
Spectral range (50% points) 305... 2800nm
Sensitivity (norminal) 7 µV/W/m²
Power supply Test cell
Electrical mains connection 400V, 3/N/PE, AC, 50Hz
Connection type fixed connection
Max. simultaneous power requirement approx. 32.0 kW
Supply line fuse 3 x 63, Char C (A)
Power supply SolarConstant
Electrical mains connection 400V, 3/N/PE, AC, 50Hz
Connection type
Max. simultaneous power requirement approx. 30.0 kW
Supply line fuse 3 x 63, Char C (A)
Outer dimensions of the test cell complete with: Genset room/switch cabinet
and control cabinet for SolarConstant 2500
Outer dimensions of aggregate room width 3440 mm x height 2580 mm x depth 2950 mm
/switch cabinet width 2200 mm x height 1830 mm x depth 1100 mm
Outer dimensions of condenser, split width 900 mm x height 950 mm x depth 2000 mm
Mass of test cell, total approx. 2700 kg
Dcebveklv H Isq Rxrjg
Mass of condenser, empty 153 kg
Weight : 2700 Kg
Type: 3707/06
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

785 km
Temperature chamber -40°C to +180°C
WEISST/210/40/3
Call
Condition: excellent (used), White
Type: T/210/40/3
Technical data:
Air-cooled
Cooling/heating operation: -40°C...+180 °C
Temperature change rate:
Cooling: approx. 3.1 K/min
Heating up: approx. 2.5 K/min
Temperature deviation
temporal ±0.2 to ±0.5
spatial ±0.5 to ±1.5
External dimensions: 1640 x 850 x 1290 mm
Test chamber dimensions: 630 x 560 x 570 mm
Test chamber volume 201 liters
The supply voltage is
Power supply 230 V (+-10%) 1/N/PE AC 50 Hz.
Rated current: 7A
Nominal output: 1.5 kW
Refrigerant: R449A
Weight 325 kg
The following information is for your safety as a buyer!
Dcebvq Rxjrz Rl Rjrog
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Subject to changes and errors in the technical data and specifications!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Climate chamber Temp. and humidity
EspecPHP-J3 bis +100°C
Call
Condition: excellent (used), Espec
Type: PHP - J3
Technical data:
Air-cooled
Temperature and humidity range Room temperature +10°C to +100°C / 40 to 98% rel. LF
Temperature fluctuation ±0.3 K
Humidity fluctuation ±2.5%
Volume 398 liters
Dimensions:
Internal dimensions: Width 600 mm x height 830 mm x depth 800 mm
External dimensions: Width 1010 mm x height 1690 mm x depth 1273 mm
Mains voltage: 400 VAC 3∅ 50 Hz
Maximum current 400 VAC 8.3 A
Weight: 335 kg
Scope of delivery: Espec climatic test chamber
The following information is for your safety as a buyer!
Dcebvq Rstzbzcjxreg
The following points are carried out on our chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
We make the search easier for you
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Measuring & testing equipment (1,321)
Search Machineseeker now with more than 200,000 used machines:This may be of interest to you

Find out now
+44 20 806 810 84
+44 20 806 810 84
Create listing
*per listing / month