Used Measuring & testing equipment for sale (1,325)
Sort results
- Lowest price Highest price
- Latest listings Oldest listings
- Shortest distance Farthest distance
- Latest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Latest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Latest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation A to Z
- Designation
- designation Z to A
- Designation
- Model A to Z
- Model
- Model Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest running time
- Runtime
- Relevance
- Relevance
Listing

785 km
Temperature test chamber 600 liters
CTST-70/600/S -70°C bis 180°C
Call
Condition: excellent (used), CTS
Type: T-70/600/S
Water-cooled temperature test chamber
Control system:
- 32 bit controller
- LCD control panel
- Digital display of set and actual values
- Numerical input of setpoints
- Error messages in plain text
- RS 232 interface
- Free switching channels for on-site test material control
Technical performance data
Temperature tests:
Fob Eou U Ixms Sfgdjgb
Temperature range -70 °C to +180 °C
Temperature deviation ±0.1 to ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 2.5 K/min
Heat radiation
approx. 2500 W at +20°C
approx. 2500 W at + 0°C
approx. 1800 W at -40°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without irradiation and without additional equipment.
Dimensions:
Test volume 600 liters
Test chamber dimensions Height, approx. 850 mm, width, approx. 850 mm, depth, approx. 830 mm
External dimensions Height, approx. 1900 mm, width, approx. 1120 mm, depth, approx. 1875 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 8.8 kW
Nominal current 14.8 A
Protection class IP 22
Weight approx. 700 kg
Refrigerant: R404A / R23
Weight: 600 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Shaker system
LDS+Tira V824 + SPA30K
Call
Condition: good (used), LDS
Type: V824 + Tira sliding table + SPA30K
Shaker for medium forces
Technical data:
Sine force vector 26.689 kN (peak)
Noise force vector 25,355 kN (effective)
Half sine force vector 53,376 kN
Mass of the movement element 21.55 kg
Frequency range d.c. - 3200 Hz
Sinus Bacceleration max. 981 m/s²
Noise Acceleration max. 50 gn rms
Velocity max. 1.78 m/s
Deflection ± 12.7 mm
Sliding table:
WxHxD: approx. 1650 mm x 925 mm x 2450 mm
Work surface: 991 mm * 991 mm
Usable frequency range 0 to 2000 Hz
thickness of the panel : 50 mm
Weight of the panel: 94 kg
Max load : 2200 kg
Condition : gebraucht / used
Fgob E Sfgouzf R Aodeb
weight:
Shaker approx. 1725 kg
Sliding table 3500 kg
Scope of delivery: (see pictures)
Total weight approx kg 5300
(We reserve the right to make changes and errors in the technical data!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Temperature shock test chamber
Weiss130 Liter TS 130 50010
Call
Condition: excellent (used), Here we offer a temperature shock test cabinet.
White Temperature Shock Test Cabinet Air Cooled
Specification:
Temperature range hot chamber +60°C ... +220°C
Temperature range cold chamber -10°C ... -80°C
Change hot/cold chamber 10 sec.
Temperature constancy ±1 K
Dimensions and further data:
External dimensions: Height 1990 mm
Width ( without and with door hinge ) without....approx. 1820 mm with....approx. 1850 mm
Depth ( without and with test room door ) without....ca. 900 mm with....ca. 1155 mm
Dimensions of the lifting basket ( test chamber ) height 450 mm, width 500 mm, depth 600 mm
volume 130 liters
Test space load max. 20 kg
Test chamber floor load max. 20 kg
Cooling water pressure min. 2 ... max. 6 bar
Max. Backup fuse 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of unit approx. 65 dB(A)
Cooling cascade water cooled
Connected load: 3/N/PE/AC 400V ±10% 50Hz /14,0 kW
nominal current 26,0 A
Refrigerant R 404A / R23
Fjb E Son Aq Ufofgdsgb
Weight: approx. 950 kg
Type: TS 130
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.

Find out now
+44 20 806 810 84
+44 20 806 810 84
Create listing
*per listing / month
Listing

785 km
Climatic test chamber -40 to +180°C
WeissWK-480/40/10 480 Liter m. Feuchte
Call
Condition: excellent (used), Here we offer a Weiss climatic test chamber.
Water-cooled
Test chamber lighting Halogen bulb 24V, 50W
Data for temperature tests:
Temperature range: -40°C to +180°C
Temporal temperature deviation in the center of the chamber: ± 0.3 to ± 0.8 K
Spatial temperature deviation: ± 0.5 to ± 2 K
Temperature change rate
Heating: 10 K/min
Cooling: 12.5 K/min
Heat compensation at +20°C 8000 W
Heat compensation at -20°C 3000 W
Data for climate tests
Temperature range: +10°C to +95°C
Humidity range: 10 to 98 % r.h.
Temperature deviation in time in the center of the usable space: ± 0.2 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1 K
Humidity fluctuation over time in the center of the usable space: ± 1 to ± 3 % RH
Test chamber dimensions: Height 950 mm, width 760 mm, depth 650 mm,
External dimensions: Height 2025 mm, width 1090 mm, depth 2480 mm,
Nominal voltage: 3/N/PE AC 400 V ± 10% 50 Hz
Rated current: 24 A Rated power: 16.0 KW
Refrigerant: R452A
Feb Ejq Dpzys Sfgdogb
Weight: approx. 900 kg
Type: WK-480/40/10
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Vibration test system
RMSSW 1507 / TGA 1500
Call
Condition: excellent (used), RMS vibration exciter with power amplifier and cooling fan
Here we offer you a RMS vibration exciter with power amplifier.
Fsb E Sfgogkaibedjgb
Vibration exciter SW 1507
Max force 2158 N
max. speed 1,3 ms
Power amplifier TGA 1500
3 x 380V/ 50Hz/ 35A / 8 kVA
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Written order possible by email or fax
Listing

785 km
Temperature shock chamber
EspecTSA-201 SW
Call
Condition: excellent (used), Espec Temperature Shock Chamber
Here we offer you an Espec temperature shock chamber.
Thermal shock environmental chamber (cold load: -65° to 0°C). Conventional thermal shock chambers with three zones can be quite large because three separate chambers are used.
The TSA series has only one chamber, significantly reducing its size. Instead, it circulates cold, hot or ambient air as needed.
The conditioned air can be precooled or preheated beyond the set point, allowing for faster recovery to the desired condition after transfer.
Espec Temperature Shock Chamber Water Cooled TSA-201S SN: 153000154
Hot chamber: +60 to 200°C Cold chamber: -70 to 0°C
Working temperature: 0-40°C
System: two zone or three zone test by flap switching.
Performance:
Test range:
High temperature. Exposure range: +60 to +200°C
Low temperature. Exposure range: -70 to 0°C
Temperature variation ±0.5°C
Hot chamber:
Temperature Heating time: ambient temp. to +200°C within 15 min.
Cooling chamber:
Temperature Pulldown time: ambient temp. to -75°C within 45 min.
Temperature recovery: within 10 min.
Inner dimensions (W x H x D mm): 650 x 460 x 670
External dimensions (W x H x D mm): 1550 x 1900 x 1670
Power supply: 380/400/415V AC 50Hz: 70 A
Refrigerant: R404/R23
Weight: approx. 1400 kg
Type: Espec Model: TSA-201 SW
Fsb Esg S Ugko Sfgdsgb
For you as a buyer, the following information for your safety!
The following points are checked on our offered chambers in advance.
Listing

785 km
Chamber convection oven
EliogKU 300/09-06-06/2
Call
Condition: excellent (used), Eliog
Here we offer you a chamber air circulation furnace.
Usable space dimensions : height mm 900 / width mm 600 / depth mm 600
324 liters
Outer dimensions : height mm 1775 / width mm 900 / depth mm 953
Door leaf 1
Connected load: 3X400V 50 Hz 13 kVA
Heating power: 12 kW
Nominal temperature: 300°C
Fgob E Sfgjifkiijdsb
weight: 400 kg
Type: KU 300/09-06/2 K1051071
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

785 km
Temperature test chamber ex protected
CTS-30°C bis +80°C T-30/950 Ex/I
Call
Year of construction: 2011, Condition: excellent (used), Here we offer you CTS temperature test chamber.
Control-32 bit controller
LCD control panel
Digital display of set and actual values
Numerical input of the setpoints
Error messages in plain text
Interface RS 232
Free switching channels for on-site test material control
Temperature tests:
temperature range -30°C to +80°C
temperature deviation ±0,3 K temporally
Temperature change rate
heating 2 K/min
Cooling 1.5 K/min to -10°C
Heat radiation approx. 1000 W at +20°C
approx. 200 W at -25°C
Data for gas supply:
Temperature range: -25°C to +55°C
Temperature deviation: ±0.25 K to the test space
Temperature change rate measured on average at a gas flow of 10 Nm³/h: at least as fast as the test chamber
Data for the gas return:
Temperature range: +18°C to +30°C
Temperature deviation: ±0.25 K to the test chamber
Nitrogen inerting with residual oxygen monitoring
With nitrogen inerting, the test chamber is first purged with the large purge volume N2 until the
oxygen content is less than 3%. After that, the system switches to a base load (approx. 10% of the large flush volume).
is switched over.
The nitrogen flow rate of the base load is measured with a flow meter, displayed and monitored by a limit switch.
and monitored by means of a limit switch.
The O2 monitoring system continuously extracts from the test chamber via a flashback arrestor
gas from the test chamber via a flame arrester and passes it over an O2 sensor that monitors the residual oxygen content of the extracted air.
The gas is then returned to the test chamber via a second flashback arrestor.
test chamber. The exhaust pump is monitored by a volumetric flow meter. Further details can be found
can be found in the Dräger operating instructions in the appendix.
The gas device is currently out of service!
The technical data refer to an ambient temperature of +25 °C,
Nominal voltage 400V , without test material, without irradiation and without additional equipment.
Dimensions:
Test volume 950 liters
Test chamber dimensions height approx. 700 mm / width approx. 900 mm depth approx. 1500 mm
External dimensions height approx. 2400 mm / width approx. 1270 mm depth approx. 3125 mm
Operating data:
Fgsb Eoihb Amo Sfgdjb
Electrical connection 400V+6/-10 %, 3/N,50 Hz
rated power 21,6 kW
rated current: 36,5 A
Protection class IP 54
condensate drain pressureless R 1/2" female thread
Sound pressure level < 62 dB(A)
(according to DIN EN ISO 3744
measured at 1m distance from front)
weight: approx. 1500 kg, control cabinet approx. 300 kg
external refrigeration unit
refrigerant R404A / R23
Type: T-30/950 Ex/I
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

785 km
Temperature chamber
WEISSWT1-340/30
Call
Condition: excellent (used), Weiss temperature chamber
Here we offer Weiss temperature chamber.
Converted to R452a
Weiss temperature chamber air cooled
Temperature range: from - 30°C to 180°C
Temperature change rate cooling 1,6 K/min
Temperature change rate heating 2,1 K/min
Test chamber dimensions: Width 550 mm x depth 750 mm x height 800 mm
Housing dimensions: Width 800 mm x depth 1500 mm x heights 1800 mm
Voltage: 3/N/PE AC 400V±10% 50Hz
Rated power 4,9 kW Rated current 9 A
Refrigerant: R452a
Weight: 515 kg
Type: WT1-340/30
For you as a buyer the following information for safety!
Fgsb Esic Rgfe Sfgdsb
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

785 km
Laboratory furnace
DespatchLCC1-16NV-3
Call
Condition: excellent (used), Here we offer a Despatch lab oven.
Despatch Laboratory Ovens
+ 8 "WAFER
LCC: Maximum temperature 260 ° C
Lockable circuit breakers turn on the control panel for easy maintenance
Protocol 3 control with large LCD display, built-in data logging capabilities and USB port for easy oven setup and data export
Edelstellenne room with interior seams welded continuously on the insulation side to protect the working space from pollution
Programmable door locking prevents the operator from opening the oven door while the cycle is running
The door lock switch turns off the heating when the door is open
The rolled air flow consists of 100% HEPA (High Efficiency Particulate Air) and is filtered to ISO Class 5 (Class 100) throughout the process cycle
The Magnehelic Manometer monitors the pressure drop of the HEPA filter so you know when to replace the filter
Electric door unlocking for ergonomic operation
UL & C-UL Listed Control Panel Open
Modbus communication connection (RS485) for remote monitoring and recording
Chamber measure L 350 mm
Chamber measure B 350 mm
Chamber Measure H 350 mm
Maximum temperature 260°C
Digital screen Yes
Electric connection 230 V
Total size L 830 mm
Total dimensions B 910 mm
Total Measure H 560 mm
Fgsb Eed Nfq Io Sfgdsb
Type: LCC1-16NV-3
Condition: used/used
Delivery: (See picture)
(Changes and errors in technical D
Listing

785 km
Climatic chamber
Vötsch VC³ 4100
Call
Condition: excellent (used), Vötsch climatic test chamber
Fgsb Eoqnutms Sfgdeb
Here we offer a Vötsch climate test chamber.
Designation VC³ 4100 Air-cooled
With temperature change rate of 3 K/min
Test chamber dimensions: Height 950 mm x width 1100 mm x depth 950 mm
Device dimensions: Height 2000 mm x width 1300 mm x depth 1916 mm
Volume: 990 liters
Feed-through: Ø 125 mm Ø 50 mm
Data for temperature tests:
Temperature range -42°C to +180°C
Temperature deviation in time ± 0.1 to ± 0.5 K
Temperature homogeneity in space ± 0.5 to ± 1.5 K
Rate of temperature change:
Heating 4.0 K/min
Cooling 3.0 K/min
max. heat compensation at +20°C 4500 Watt
Data for climate tests
Temperature range +10°C to +95°C
Dew point range -3°C to +94°C
Humidity range 10 to 98% r. h.
Temperature deviation temporal ± 0.1 to ± 0.3 K
Spatial temperature homogeneity ± 0.5 to ± 1.0 K
Humidity deviation temporal ± 1 to ± 3% r. h.
Heat compensation max. 500 W
Voltage: 3/N/PE AC 400V ± 10% 50Hz
Rated power: 11.5 kW
Rated current: 22.0 A
Refrigerant: R-404 A
Weight approx. 840 kg
Type: VC³ 4100
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after a successful check, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
C02 incubator CO2 incubator
JouanIG 150
Call
Condition: good (used), Here we offer a Jouan C02 incubator CO2 incubator.
The CO2 incubator is used to grow cell cultures.
The following conditions are required for this:
a sterile atmosphere
a constant temperature
a CO2-enriched atmosphere
high humidity
Dimensions and weight:
Temperature range: room temperature + 5 ° C to 50 ° C
CO2 detector: Infrared
Size: 90 x 73 x 60cm
Internal dimensions: 66 x 48 x 45 cm
Outer material: steel
Interior material: Stainless steel
Inner door: Safety glass
CO2 Incubator Jouan IG 150
Water jacket volume 85 liters maximum
Volume 154 liters
Maximum number of trays (3 supplied)
Usable area per tray 0.16 m2
Usable maximum incubation area: 1.28 m2
minimum spacing height 66 mm
empty weight approx. 80 kg
Weight when filled with water approx. 170 kg
Weight with packaging approx. 100 kg
Power connection required: 230 V, 50 or 60 Hz.
Power consumption max. 800 VA, normal consumption at 37 °C: 220 watts
Fuses therm. Magnetic switch, set to 5 A at 220 V Phases earthed.
Color of connections brown = phase, blue = neutral, yellow/green = earth
Working range:
Ambient temperature 15 - 30°C
CO2 inlet pressure 300 mbar - 3 bar
Interior temperature range from 5°C above room temperature to 45°C
Working range with CO2 gas 0.0 % to 20.0 0/0
Article weight: 80.00 kg
Type IG 150
Scope of delivery: (see picture)
2 weeks commissioning guarantee
The device comes from stock.
We deliver with express shipping (DHL, UPS, TNT)
Fjbjccb N Uj E Sfgdsgb
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Test chamber for parametric test
S & A55°C bis +150°C 4220A
Call
Condition: good (used), Here we offer you an S & A test chamber for parametric testing.
S & A test chamber for parametric testing
Temperature range: 55°C to +150°C
Stability:
Fjb E Sfocnic Segdsgb
± 0.1 ° C including the effects of mains voltage, ambient temperature and ageing.
temperature and ageing
Cooling medium: Water-cooled mechanical cooling
Chamber can be controlled remotely via IEEE bus or
RS232C interface
Weight approx. 250 kg
Type: 4220A
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Temperature cabinet 335 liters
WeissWT3-340/40 -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss temperature chamber.
Weiss temperature test chamber With S!MCON / 32 control Water-cooled
(refrigerant converted to R-452A)
Touch panel" control unit
All control and operating commands can be triggered on the "touch panel" control unit by simply touching the function icons.
all control and operating commands by simply touching the function icons.
Levelling feet
To compensate for uneven floors and to ensure adequate ventilation of the machine part,
the test chamber is equipped with adjustable feet.
Feed-throughs
The test chamber is equipped with feed-throughs on the right and left side.
Measuring cables and test equipment can be routed through these into the test chamber.
Feed-through built into basic equipment
R1: NW 125 mm
L1: NW 50 mm
Test chamber capacity: approx. 335 liters
Test chamber dimensions: Height 750 mm, width 580 mm, depth 765 mm
External dimensions: Height 1775 mm, width 870 mm, depth 1600 mm
Data for temperature tests:
Temperature range: -42 to +180 °C
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate
Heating: 3.2 K/min
Cooling: 4.0 K/min
Heat compensation max. 2300 W
Data for operation:
Test room lighting Halogen bulb 2x 24V, 50W
Rated voltage: 3/N / PE AC 400 V ± 10% 50 Hz
Rated current: 14 A Rated power 4.1 kW
On-site fuse 16 A slow-blow
Sound pressure level approx.
measured at a distance of 1 m from the front. 1m height 56 dB(A)
Refrigerant: R-452A
Weight: 515 kg
Type: WT3-340/40
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
Fgoborbigfj E Sfgdob
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Temperature test chamber 680 liters
Heraeus VötschVLM 3068/S -30 °C bis +125 °C
Call
Year of construction: 2010, Condition: excellent (used), Here we offer you a Heraeus Vötsch temperature test chamber.
Fgjb E Sforbiyfjgdob
Vötsch temperature test chamber VLM 3068/S air-cooled
(building material test chambers loaded from above)
Control panel
The control panel is mounted on a console on the temperature test chamber. By
control and operating commands can be triggered by simply touching the function symbols.
can be triggered. The operating instructions for the control panel are enclosed
Main switch
The main switch is located at the front of the temperature test chamber.
Air treatment room
The air treatment room is located in the test room
and contains the components required for temperature control.
In the air treatment room, the air is tempered (cooling/heating) and circulated by the test room fan.
circulated by the test room fan. The air is sucked in at the center of the side wall and
enters the test chamber again via the air baffles on the long sides.
Feed-throughs
The temperature test chamber can optionally be equipped with feed-throughs. Through these
can be used to route cables and test equipment into the test chamber.
Entry port front 2 x 82 mm ∅ rear 1 x 85 mm ∅
Internal dimensions Width 2000 mm Depth 570 mm Height 600 mm
External dimensions Width 3000 mm Depth 870 mm Height 1060 mm
Technical data:
Data for mechanical load:
Max. load with test material
Test area floor
(evenly distributed over the surface) 600 kg
Point load 50 kg
Data for temperature tests:
Temperature range -30 °C to +125 °C
Temperature deviation over time in the center of the usable space ±1 K
Temperature change rate
Heating approx. 1 K/min
Cooling approx. 2 K/min
Data for operation:
Nominal voltage 3/N / PE AC 400 V ±10% 50 Hz
Rated power 3 kW Rated current 9 A
Customer fuse 16A slow-blow
Temperature test chamber VLM 3068/S
Test chamber volume approx. 680 l
Weight approx. 700 kg
Refrigerant: R-404A
Noise measurement Sound pressure level approx. 68 dB(A)
Type: VLM 3068/S
Condition: second-hand / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Leak test bench
KSE
Call
Condition: excellent (used), KSE Leak Test Bench
Here we offer a KSE leak test bench.
Feb E Ssiu H Hcefgdogb
Test bench for automotive
Testing of electric drives
Isolatio/Tightness E-Motors
Supply voltage: 400 VAC
Control voltage: 24 VDC
Connected load: 0,75 kW
Type: KSE I/SB-3
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

785 km
Shaft meter
MahrHelio-Pan II 700
Call
Condition: excellent (used), Mahr
Here we offer you a Helio-Pan II.
max. workpiece weight 30 kg at center height 100 mm
80 kg with center height 150 mm
measuring range length 0 mm to 700 mm
measuring range outer diameter 0 mm to 120 mm
max. throwing distance to be measured 100 mm
tip height 100 mm
Measuring blades probe and caliper 1 mm x 5 mm
Dimension (W x D x H)
machine 2060 mm x 920 mm x 1750 mm
controller box 600 mm x 800 mm x 2200 mm
Fgsb E Ssi Ezh Uefgdob
Weight approx. 900 kg
Electrical power 230 V / 1200 W / 50 Hz
Air pressure 6 bar
Type: Helio-Pan II 700
Scope of delivery: (See picture)
Further questions we can answer on the phone for you.
Written order possible by email or fax
Listing

785 km
Emission test chamber 480 liters
VötschVCE 1000/S +20°C bis +130°C
Call
Condition: excellent (used), Here we offer you a Vötsch emission chamber.
Water cooled
Test chamber volume 1000 liters (usable) (916) liters Adjustment tank 480 liters
Performance for temperature tests:
Temperature range +20°C to +130°C
Temperature deviation temporal K ±0.1 to ±0.3
Temperature deviation spatial K ±0,5
Temperature gradient K 1
Temperature rate of change:
Cooling K/min 0.3
Heating K/min 0,4
Performance for climatic tests:
Carrier gas conditioning with climatic module
Fsb Eei Hbyle Sfgdegb
according to the evaporation principle
Temperature range +20°C to +130°C
Humidity range 5 to 95%
Dew point range +5°C to +60°C
Humidity deviation in time % ±1 to ±3
Carrier gas exchange rate 0.1 to 1.8 chamber volume per hr.
Capacity range for desorption
Desorption temperature up to max. +240°C, adjustable
Test chamber surface temperature between +220°C and +240°C
Purge rate max. 4 m³/h
Test chamber dimensions: Width 750 mm Depth 1630 mm Height 750 mm
test chamber door 670 x 670 mm
Outer dimensions: Width 1350 mm Height 2950 mm Height 2050 mm
rated current 32 A
nominal power 19,0 kW
Electrical connection 3/N/PE AC 400V ± 10% 50Hz
Weight 1200 kg
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Type: VCE 1000/S
Condition: used / used
Scope of delivery: (See picture)
Sale ex location
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

785 km
Analytical drift detector
Oxford InstrumentsINCAx-act
Call
Condition: excellent (used), Oxford Instruments
Here we offer you an INCAx-act Analytical Drift Detector.
Microanalysis of elements including boron and above
Operating temperature
Normal mode 10-25 degrees
Operating temperature
extended mode 10-30 degrees
Storage temperature
-25 to 40 degrees and 8 to 80% humidity non-condensing
Operating humidity
Fgeb Eshx Ncho Sfgdsb
Listing

785 km
Vibration test system
RMSSW 3006 mit TGA 1500
Call
Condition: excellent (used), RMS Vibration Test System
Here we offer you a RMS electrodynamic vibration test equipment.
RMS Vibration Test System
Vibration exciter SW 3006
Power amplifier TGA 1500
Technical data:
Sine:3,7 kN
Noise:3,7 kN
Shock:3.7 kN
Displacement pk-pk:26 mm
Feb Eohyly Rs Sfgdogb
Speed: 0.9 m/s
Acceleration: 80 g
Cooling: air cooled
Condition: used / used
Untested! Tests were not possible
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Written order possible by email or fax
Listing

785 km
Salt spray test chamber Climate change test
WeissSC / KWT-1000 1000 Liter
Call
Condition: excellent (used), White
Type: SC / KWT - 1000
Technical data:
Salt spray mist test MIN 5 K > Tu MAX +50°C
Condensation water test MIN 5 K > Tu MAX +45°C
Humidifier MIN 5 K > Tu MAX +75°C
Temperature constancy
The temperature deviation over time is ±1 K
Dimension with hood:
Test chamber: H 1190 mm x W 1650 mm x D 570 mm
Dimensions without hood:
Fgjb E Sorh Dmqefgdsb
Test area: H 740 mm x W 1650 mm x D 570 mm
Dimensions with hood:
Outside: H 1370 mm x W 2730 mm x D 800 mm
Dimensions without hood:
Outside: H 920 mm x W 2730 mm x D 800 mm
Capacity approx. 700 - 1130 liters
3/N/PE AC 400V ±10%50Hz
Rated power 4 KW Rated current 7.5 A
Weight: 180 kg
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Trust Seal
Dealers certified through Machineseeker

Listing

785 km
Vacuum drying oven
HeraeusVT 6025 200°C
Call
Condition: excellent (used), Heraeus
Type: VT 6025
Heraeus Vacutherm vacuum drying oven
Specification jacket heating VT 6025
Temperature (metric) 200 °C
Dimensions, inside (W x D x H): 300 x 307 x 275 mm
External dimensions (W x D x H): 480 x 450 x 600 mm
Electrical requirements 230 V, 50/60 Hz
Frequency 50/60 Hz
Capacity (metric) 25 l
Heating jacket type without inert gas connection
Voltage 230 V 1.3 kW, 5.9 A
Weight: 58 kg
Condition: second-hand / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Fob E Sfgjrknagodogb
Listing

785 km
Acoustic scanning microscope
SonixEcho VS Ultraschall Mikroskop
Call
Condition: excellent (used), Sonix
Type: Echo VS
Acoustic scanning microscope enables the inspection of packaging.
Features:
To detect the smallest and most subtle defects in state-of-the-art packaged microelectronics applications,
Fgsbjtz Rkme E Sfgdjb
ECHO VS includes standard features such as heated water for optimal acoustic coupling,
flexible TAMI for efficient acquisition of the most useful data,
Waveform Averaging for improved signal-to-noise ratio, ICEBERG for improved image quality and MFCI for improved image quality in the most demanding applications.
ECHO VS is the ultimate ultrasonic NDT device for molded flip chips, CSP, MCM, stacked die,
MUF and other advanced packaging technologies.
Detects air defects as small as 0.01 microns and spatially resolves defects down to 5 microns.
Image enhancement suite with heated water, waveform simulation and other innovations
for industry-leading image quality in advanced packaging applications
Image optimization for improved image quality in complex molded flip chips (MUF) and packages with polyimide layers
Waveform averaging for improved signal-to-noise ratio
Wide range of converters from very low to ultra-high frequency
Stacked Die Imaging (SDI) (optional)
Molded Flip Chip Imaging (MFCI)
Voltage / power consumption:
100-120/220-240 VAC
1PH/N/PE, 50/60 Hz 10 A
Condition: gebraucht / used
Scope of delivery: (see picture)
(Subject to changes and errors in the technical data and specifications!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Extrusion plastometer Melt index test
ZwickRoellMflow
Call
Condition: excellent (used), Zwick / Roell
Type: Mflow
Area of application
With increasing test volumes, the need for a higher degree of automation also increases
(compared to the Cflow). The Mflow is a modularly expandable device,
with which you can determine the melt mass and melt volume flow rate.
The basic version of the Mflow extrusion plastometer is designed for MFR tests according to method A
and can be upgraded for MVR tests according to method B. Tests according to the following standards are possible:
- Methods A and B according to ISO 1133
- Methods A, B and C according to ASTM D 1238
- ASTM D 3364
- JIS K 7210
As an option, you can equip the Mflow with the pneumatic weight lift with and without cleaning function, for example.
without cleaning function or weight staking.
The Mflow can be operated both stand-alone via a modern touch display,
as well as with the ZwickRoell testing software on a PC.
Technical data
Test load: 0.325 - 21.6 kg
Compressed air, lubricated, dry: 6 - 10 bar
Dimensions
Height: 510 mm
Width: 360 mm
Depth: 419 mm
Weight: approx. approx.: 43 kg
Test temperature: +50°C - +450°C
Display: Capacitive touch display
Resolution of the temperature display: < 0.1 K
Number of storable parameter sets: >100
Temperature accuracy in the range 0 - 75 mm
above the nozzle in the temperature range 50°C - 450°C: < 0,3 K
Time measurement
Error limit (method A): ± 0.02 (with automatic cut-off device)
Error limit (method B): ± 0.01
Displacement measurement
Error limit (method B):
±0.02 mm (ISO 1133) /
±0.4 % of 6.25 mm
(ASTM D 1238)
Resolution: < 0.005
Multi-device operation on one PC:
Available working memory, min.: 1.54 GB
Clock frequency: 3 GHz
Connectable Mflow extrusion plastometers per PC: 6
Mains connection: 220 - 240 V, 1L/PE/N
Fgsb Eotq Em Te Sfgdob
Power consumption: 2.6 A
Mains frequency: 50/60 Hz
SW version: V4.2
Year of manufacture: 2021
Condition: used / second-hand
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We can answer further questions for you on the phone.
Listing

785 km
Temperature shock test system
RS SimulatorenST2K320/45 K
Call
Condition: excellent (used), RS. simulators
Type: ST2K320/45 K
Water-cooled shock test system
Temperatures in the upper test chamber
Temperature range: + 40 °C to + 180 °C
Time deviation: ± 0.8 K according to DIN 50011 with empty test chamber
Temperatures in the lower test chamber
Temperature range: - 40 °C to +100 °C
Time deviation: ± 0.8 K according to DIN 50011 with empty test chamber
Humidity in the upper test room
Climatic temperature range: + 40 °C to +90 °C
Humidity range: 20 % to 98 % (± 2 to 5 %) relative humidity
Humidity: 25% to 75% relative humidity
Working climate range:
Temperature: + 12 °C to + 30 °C
Humidity: 25 % to 75 % relative humidity
Dimensions: Width 900 mm Height 2000 mm Depth 2300 mm
Test room dimensions: Width 470 mm Depth 700 mm Height 440 mm
Electrical power supply:
Total power: 13 KVA
Current consumption: 25 A
Voltage: 3x400V/N/PE / 50Hz
Refrigerant: R404A/2.5 kg
Chamber: approx. 950 kg
Fgob Ejtrf Ule Sfgdob
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
We make the search easier for you
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Measuring & testing equipment (1,325)
Search Machineseeker now with more than 200,000 used machines:This may be of interest to you

Find out now
+44 20 806 810 84
+44 20 806 810 84
Create listing
*per listing / month