Used Measuring & testing equipment for sale (1,325)
Sort results
- Lowest price Highest price
- Latest listings Oldest listings
- Shortest distance Farthest distance
- Latest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Latest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Latest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation A to Z
- Designation
- designation Z to A
- Designation
- Model A to Z
- Model
- Model Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest running time
- Runtime
- Relevance
- Relevance
Listing

785 km
Acoustic scanning microscope
SonixEcho VS Ultraschall Mikroskop
Call
Condition: excellent (used), Sonix
Type: Echo VS
Acoustic scanning microscope enables the inspection of packaging.
Features:
Dueb Hjtz Rkmehigcst
To detect the smallest and most subtle defects in state-of-the-art packaged microelectronics applications,
ECHO VS includes standard features such as heated water for optimal acoustic coupling,
flexible TAMI for efficient acquisition of the most useful data,
Waveform Averaging for improved signal-to-noise ratio, ICEBERG for improved image quality and MFCI for improved image quality in the most demanding applications.
ECHO VS is the ultimate ultrasonic NDT device for molded flip chips, CSP, MCM, stacked die,
MUF and other advanced packaging technologies.
Detects air defects as small as 0.01 microns and spatially resolves defects down to 5 microns.
Image enhancement suite with heated water, waveform simulation and other innovations
for industry-leading image quality in advanced packaging applications
Image optimization for improved image quality in complex molded flip chips (MUF) and packages with polyimide layers
Waveform averaging for improved signal-to-noise ratio
Wide range of converters from very low to ultra-high frequency
Stacked Die Imaging (SDI) (optional)
Molded Flip Chip Imaging (MFCI)
Voltage / power consumption:
100-120/220-240 VAC
1PH/N/PE, 50/60 Hz 10 A
Condition: gebraucht / used
Scope of delivery: (see picture)
(Subject to changes and errors in the technical data and specifications!)
We will be happy to answer any further questions you may have on the phone.
Listing

1,077 km
Temperature chamber - 70°C to 180°C
WEISSWT11-270/70/10
Call
Year of construction: 2001, Condition: ready for operation (used), Functionality: fully functional, machine/vehicle number: 58226018400020, Weiss Temperature Chamber
Type: WT11-270/70/10
Section No.: 58226018400020
Dueb Hhigjv T Tncscet
Control: Simcon/32-NET Version: 00.1902
Ports: Left (2x) NW 50 mm, Right (3x) NW 125 mm
Temperature Range: -70°C to 180°C
Test Chamber Volume: 270 liters
Door with window, interior lighting
Water-cooled temperature chamber
Compressed air dryer type: ZANDER
Temperature change rate cooling: 10 K/min
Temperature change rate heating: 10.0 K/min
Temperature deviation over time ± 0.1 to ± 0.5 K
Temperature homogeneity over space ± 0.5 to ± 2.0 K
Test Chamber Dimensions: Width 580 mm x Depth 615 mm x Height 750 mm
Housing dimensions: Width 895 mm x Depth 2080 mm x Height 1950 mm
Voltage: 3/N/PE AC 400V±10% 50Hz
Rated power 14 kW, Rated current 26 A
Refrigerant: R-404A/R-23
Listing

838 km
Kopierer-Welt - Levelling laser
Spectra Pricision GL422N, inkl. HL750
Call
Condition: used, In this offer you are purchasing a used dual-cutting laser "Spectra Pricision GL422N"
Object of sale:
1 x Spectra Pricision GL422N with the following equipment:
incl. transport case
incl. hand-held and excavator receiver HL750
incl. RC402N radio remote control
A total of 3 lasers are in stock.
Condition:
This offer is a used device, which may show signs of use (minor scratches or yellowing).
(minor scratches or yellowing).
The device has been tested for function
Packaging and dispatch:
You are welcome to view the device during our business hours. Please make an appointment for this!
Seaworthy packaging and worldwide shipping available on request!
Duob Hhigoq Ht H Iecjt
For further information you can of course also contact us personally.

Find out now
+44 20 806 810 84
+44 20 806 810 84
Create listing
*per listing / month
Listing

1,030 km
Universal testing machine
Schenck Trebel13915
Call
Condition: used, Functionality: fully functional, machine/vehicle number: 100 kN, Universal testing machine, vertical; hydraulic motor pump; electronic absolute pressure transducer.
Force measuring range: 100 kN
Last calibration: 03/2023
Software: IBS TensileTest
Dusb Hhigsv Tm D Djcst
We are happy to answer any questions you may have.
Listing

785 km
Extrusion plastometer Melt index test
ZwickRoellMflow
Call
Condition: excellent (used), Zwick / Roell
Type: Mflow
Area of application
With increasing test volumes, the need for a higher degree of automation also increases
(compared to the Cflow). The Mflow is a modularly expandable device,
with which you can determine the melt mass and melt volume flow rate.
The basic version of the Mflow extrusion plastometer is designed for MFR tests according to method A
and can be upgraded for MVR tests according to method B. Tests according to the following standards are possible:
- Methods A and B according to ISO 1133
- Methods A, B and C according to ASTM D 1238
- ASTM D 3364
- JIS K 7210
As an option, you can equip the Mflow with the pneumatic weight lift with and without cleaning function, for example.
without cleaning function or weight staking.
The Mflow can be operated both stand-alone via a modern touch display,
as well as with the ZwickRoell testing software on a PC.
Technical data
Test load: 0.325 - 21.6 kg
Compressed air, lubricated, dry: 6 - 10 bar
Dimensions
Height: 510 mm
Width: 360 mm
Depth: 419 mm
Weight: approx. approx.: 43 kg
Test temperature: +50°C - +450°C
Display: Capacitive touch display
Resolution of the temperature display: < 0.1 K
Number of storable parameter sets: >100
Temperature accuracy in the range 0 - 75 mm
above the nozzle in the temperature range 50°C - 450°C: < 0,3 K
Time measurement
Error limit (method A): ± 0.02 (with automatic cut-off device)
Dujbjtq Em To Hhigcet
Error limit (method B): ± 0.01
Displacement measurement
Error limit (method B):
±0.02 mm (ISO 1133) /
±0.4 % of 6.25 mm
(ASTM D 1238)
Resolution: < 0.005
Multi-device operation on one PC:
Available working memory, min.: 1.54 GB
Clock frequency: 3 GHz
Connectable Mflow extrusion plastometers per PC: 6
Mains connection: 220 - 240 V, 1L/PE/N
Power consumption: 2.6 A
Mains frequency: 50/60 Hz
SW version: V4.2
Year of manufacture: 2021
Condition: used / second-hand
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We can answer further questions for you on the phone.
Listing

785 km
Temperature shock test system
RS SimulatorenST2K320/45 K
Call
Condition: excellent (used), RS. simulators
Type: ST2K320/45 K
Water-cooled shock test system
Temperatures in the upper test chamber
Temperature range: + 40 °C to + 180 °C
Time deviation: ± 0.8 K according to DIN 50011 with empty test chamber
Temperatures in the lower test chamber
Temperature range: - 40 °C to +100 °C
Time deviation: ± 0.8 K according to DIN 50011 with empty test chamber
Humidity in the upper test room
Climatic temperature range: + 40 °C to +90 °C
Humidity range: 20 % to 98 % (± 2 to 5 %) relative humidity
Humidity: 25% to 75% relative humidity
Djb Hjtrf Ulohigcsut
Working climate range:
Temperature: + 12 °C to + 30 °C
Humidity: 25 % to 75 % relative humidity
Dimensions: Width 900 mm Height 2000 mm Depth 2300 mm
Test room dimensions: Width 470 mm Depth 700 mm Height 440 mm
Electrical power supply:
Total power: 13 KVA
Current consumption: 25 A
Voltage: 3x400V/N/PE / 50Hz
Refrigerant: R404A/2.5 kg
Chamber: approx. 950 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Climate chamber 38m³ Sunlight simulation
WeissWK 40'/40-120/So -40° bis +120°C
Call
Condition: excellent (used), Internal dimensions (net) H approx. 2150 mm W approx. 3000 mm D approx. 6000 mm
Air circulation system (on chamber rear wall) Width approx. 800 mm
External dimensions with machine unit and without control cabinets
Height approx. 3360 mm Width approx. 3320 mm Depth approx. 8620 mm
Machine room, attached to the rear wall of the chamber
Height approx. 2340 mm Width approx. 3320 mm Depth approx. 1500 mm
Electrical control cabinet, mounted on the side of the base frame
Height approx. 2340 mm Width approx. 2400 mm Depth approx. 600 mm
Chamber door (double-leaf)
Height approx. 2150 mm Width approx. 3000 mm
Pedestrian door (single-leaf)
Height approx. 1900 mm Width approx. 900 mm
Lighting (switch next to pedestrian door)
4 incandescent lamps 60W
Feed-throughs 4 pcs. 125 mm ∅
Floor load capacity
30,000 N/m² (surface load);
2,500 N per polyamide wheel Ø100mm;
4,000 N for a wheel with 4 cm²
Ceiling opening (clear dimensions of the lower disk)
Length approx. 600 mm Width approx. 700 mm
Quantity: 10 pieces
Ceiling load: 10 SoSi radiators + 1 person 90 kg
Working temperature range:
Temperature range -40 °C ... +120 °C (discontinuous)
Cooling speed:
approx. 1 K/min. linear from 80°C to -40°C with test specimen mass and without thermal load,
measured in the air outlet of the air circulation system.
At temperatures < (-20°C) the recirculated air volume is reduced by 50%.
(e.g. PV 1200)
Heating speed:
approx. 1 K/min. linear from -30°C to +90°C with test specimen mass and without thermal load,
measured in the air outlet of the air circulation system.
(e.g. PR 308.2)
Test specimen mass: 600 kg aluminum (vehicle - partial body)
Working range climate without sunlight simulation:
Temperature range: +10 °C ...+95 °C
Temperature constancy: ≤ ± 0.5 K (temporal)
Temperature constancy: ≤ ± 2 K (spatial)
Humidity range: 20 ... 80 % r.h., without thermal load
Dew point temperature range: -2 °C ...85 °C without thermal load
Climate working range with sunlight simulation:
Temperature range: +23 °C ...+50 °C
Temperature constancy: ≤ ± 0.5 K (temporal)
Humidity range: 20 ... 70 % r.h., with thermal load
Dew point temperature range: -2 °C ...43 °C without thermal load
Thermal load of the SoSi: Max. 10 kW
Temperature and humidity instances:
Temperature
The following maximum deviation is specified for the temperature in the climate and temperature range
(including measurement uncertainty and with test material):
Blow-out after 15 minutes: ±1K
Intake after 45 minutes: ±1.5K (external sensor)
Humidity
For the relative humidity at the operating point 80°C / 80% r.h.
the following maximum deviation (including measurement uncertainty and with test material) is specified:
Blow-out after 30 minutes: ±3% r.h.
Intake after 60 minutes: ±3% r.h. (external sensor)
Connection and consumption data:
Air-cooled refrigeration unit, maximum air temperature +38°C
Refrigerant R 404 A and R23
Water supply for humidifier:
Approx. 40 l/h = 40 kg/h installed steam output,
demineralized water, electrical conductivity 5-20 μS/m
Mains connection: 400 V; 3 PH + N + PE; 50 Hz
Connected load: 250 kVA, 350 A
Connection according to VDE 0110 group 2: 5x185 mm2 CU
On-site fuse protection: 355 A
Air circulation volume (FI-controlled): 24,000 to 28,000 m³/h
FC basic setting: 50% (achievement of the parameters)
Technical data solar simulation:
Manufacturer: BF Engineering GmbH
Type: G-BEM-1119
Duobstrmm Nj Hhigcet
Number of lights: EPSU 2 x 2k_HQI
Ballast: 10
Ignitor: IGC-4k-03
Light source: OSRAM HQI 2000W High Flux
3〜/ N / PE
Listing

785 km
Climate test chamber 2500 liters
VötschVC 4200/S -40°C bis +180°C
Call
Condition: excellent (used), Vötsch
Type: VC 4200/S
Climate test chamber 2500 liters water-cooled
Temperature test:
Temperature range -40°C to + 180°C
Temperature deviation in time: ± 0.3 to ± 1.0
Spatial temperature deviation: ± 1.0 to ± 2.0
Temperature gradient 2 to 4
Heating speed: 2.0 K/min
Cooling rate: 3.0 K/min
Climatic tests:
Temperature range: +10 °C to +90 °C
Temperature deviation over time: ± 0.1 to ± 0.5
Temperature deviation over time: ± 1 to ± 1.5
Temperature gradient 2 to 3
Humidity range: 10% to 98% r.h.
Humidity deviation over time: + 1 to 3 % r.h.
Dsb Hou Au Utehigcout
Dew point range +5 to +89°C
Test room dimensions: Width approx. 2000 mm x depth 1150 mm x height 1150 mm
External dimensions: Width approx. 3500 mm x depth 1450 mm x height 2100 mm
Nominal voltage 3/N/PE AC 400 V ±10%50Hz
Rated power 13 kW
Nominal current 21 A
Refrigerant R-452A
Weight approx. 1350 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Corrosion test cabinet for salt spray
VLM CC 1000-FL HL V.745.672.120
Call
Condition: good (used), VLM
Type: V.745.672.120 Model CC 1000-FL HL
Corrosion test chamber for salt spray tests
Specifications:
Test chamber volume: approx. 1000 L
Test chamber dimensions (ΒχΤχΗ1/Η2): 1400x800x800/1020 mm
Door opening dimensions (WxH): 1300x680 mm
External housing dimensions втн: 2162 x 995 x 2080 mm
Operating temperature range: 5°C > room temperature to +80°C
Djbst Igc Sj Hhigcjut
High-load version for loads up to 350 kg
Process control: Beckhoff PLC, color touch screen display
display, 50 memory locations for test procedures, 50
Memory locations for test segments, ramps:
Humidity-temperature over the entire working range,
Ether connection
Electrical connection: 400 V, 50 Hz, 5700 W
Tap water: min. 2.5 bar Tap connection 3/4"
External thread for connecting an ion exchanger cartridge
Compressed air: 7-8 bar
Waste water: Siphon / 30 mm ID hose nozzle
Exhaust air: pipe end OD 75 mm
Operating systems:
Salt spray
Condensation water (CWC)
Ventilation Room air
Warm air
Controlled humidity
Listing

785 km
Shaker system with amplifier
LDSV895-440 HBT900C + SPA50K
Call
Condition: excellent (used), LDS
Type: V895-440 HBT900C with amplifier SPA50K
Technical data:
Fitting Dimensions: 440 mm
Sinusoidal force vector 55.6 kN (peak)
Rausch force vector 55.6 kN (effective)
Half sine force vector 166.8 kN (peak)
Frequency range 0 to 2100 Hz
Sinusoidal acceleration max. 981 m/s²
Noise Acceleration max. 490 m/s²
Speed max. 1.6 m/s
Deflection ± 63.5 mm
Oscillator mass 55 kg
Max. load 700 kg
Amplifier dimensions :
Duobeuy H I Tj Hhigcjt
WxHxD mm : 537mm x 1905mm x 895mm
Weight 622 kg
Sliding table:
Work surface: 900 mm * 900 mm
Thickness of the top : 50 mm
Weight of the top: 80.4 kg
Max load : 7250kg
Effective frequency range 5-2000 Hz
Condition : gebraucht / used
Total weight (table + shaker): approx. 7000 kg
Shaker + table dimensions: LxHxW approx. 2700 x 1500 x 1800 mm
Scope of delivery: (see pictures)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Climate test chamber with humidity 1000 liters
CTSC-40/1000 -40°C bis +180°C
Call
Condition: excellent (used), CTS
Type: C-40/1000
CTS climatic test chamber
Condenser chiller air-cooled
Control:
32 bit controller
LCD control panel
Digital display of setpoints and actual values
Numerical input of setpoints
Error messages in plain text
RS 232 interface
Free switching channels for on-site test material control
Temperature test:
Temperature range: -40°C to +180°C
Temperature change rate
Heating speed 2.0 K/min
Cooling rate 2.5 K/min
Temperature deviation ± 0.1 to ± 0.3 K in time
Heat radiation:
approx. 2500 W at +20°C
approx. 2500 W at ± 0°C
approx. 1500 W at -20°C
Climate Working range:
Temperature range +10°C to +95°C
Humidity range 10 to 98% r.h.
Dew point range I +7 to +94°C
Dew point range II -10 to +7°C
Temperature deviation ± 0.1 to ± 0.3 K in time
Humidity constancy I, temporal ± 0.5 to ± 1.5 % r.h.
Humidity constancy II, temporal ± 1 to ± 3 % r.h.
Panorama window 570 x 710 mm
Test chamber dimensions Width 1000 mm Depth 1100 mm Height 900 mm
External dimensions Width 1270 mm Depth 2220 mm Height 1950 mm
Test chamber volume 1000 liters
Pipe feed-throughs, ø 50
Electrical connection: 400 V +6/-10% 3/N, PE 50 Hz
Connected load: 8.4 kW Rated current: 12.4 A
Refrigerant: R-404A
Weight: 800 kg
The following information is for your safety as a buyer!
Deboru Dzuj Hhigcout
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Optical inspection
Vision EngineeringLynx Stereomikroskop
Call
Condition: excellent (used), Vision Engineering
Specifications of the microscope from Vision Engineering:
Eyepiece-less
Three-dimensional viewing
x3.5 - x120 stereo zoom magnification
Features:
Optical type:
Application laboratory, inspection, for research purposes, forensic medicine, for dental laboratory, for welding work
Observation technology 3D
Configuration Desktop device
Options and accessories USB camera, zoom
Magnification Min: 3 unit Max: 240 unit
Description:
Lynx EVO is designed to increase productivity and efficiency through superior ergonomics.
Regardless of the challenge - inspection, rework or refurbishment
high resolution and high contrast 3D stereo images, you will work more comfortably and
and more concentrated.
Dueb Hhietqnklsgcet
Magnifications from 2.7x to 240x make it ideal for a wide range of applications.
Greater efficiency:
Lynx EVO offers improved hand-eye coordination, more working space for tools
and better peripheral vision for easy interaction with the wider working environment
and transforms the way you work.
With no eyepieces to adjust, you can easily share between multiple users,
to get maximum return on your investment.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Temperature test chamber
CTS TS -70/600-13
Call
Condition: used, CTS
Type: TS -70/600-13
Temperature test chamber, water-cooled
Type series: TS -70/600-13
Control system:
- 32 bit controller
- LCD control panel
- Digital display of setpoints and actual values
- Numerical input of setpoint values
- Error messages in plain text
Djb Hovcyawehigcjut
- RS 232 interface
- Free switching channels for on-site test material control
Test chamber volume: 600 liters
Test chamber dimensions: Height approx. 730 mm, width approx. 850 mm, depth approx. 830 mm
External dimensions: Height approx. 2250 mm, width approx. 1300 mm, depth approx. 2475 mm
Temperature range: -70 to +180°C
Heating speed: 13 K/min at -40°C to +120°C
Cooling speed: 13 K/min at 120°C to -40°C
Temperature deviation: ± 0.1K temporal, ± 0.5 K spatial
Electrical connection 400/3P/N/PE
Nominal power: approx. 27.8 kW
Nominal current: approx. 44.1 A
Compressor: 4TC-8.2Y/4PC-10.2Y
Refrigerant: R-404 A / R-23
Weight: 1350 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Mass spectrometer
WatersnanoACQUITY UPLCTM G2-S Q-TOF
Call
Condition: used, HPLC Waters
The system consists of these modules and components:
HPLC Waters Binary Solvent Manager
HPLC Waters Auxiliary Solvent Manager
HPLC Waters HDX Manager
HPLC Waters Pal System
HPLC Waters Leap
Synapt HDMS Mass Spectrometer
Dujb Hhovcnpaoigcot
HPLC Waters Binary Solvent Manager
Flow control modules
Flow rate from 0.20 to 5.00 µl/min
Solvents are mixed in the T-piece outlet of the flow control module.
Auxiliary solvent manager
Flow rates from 0.10 to 5.00 µl/min.
Flow control module
Flow rate from 0.20 to 5.00 µl/min
Sample manager
The sample manager injects the samples it takes from microplates or vials into the chromatographic flow stream.
In maximum throughput mode, the sample manager can perform an injection in approximately 45 seconds,
including a single standard rinse, or it can do so in less than 60 seconds,
including a double standard flush.
The sample manager accepts standard impression plates, 5.03 $0.02 in. x 3.365 $0.02 in,
SBS/ANSI compliant plates (maximum height of 2.2 inches, including covers).
The sample manager can test samples at any temperature between 4 and 40 °C (39 and 104 °F)
at ambient conditions of 25 °C (77 °F) or less.
Heating and trapping module
Inner diameter of up to 300 micrometers and a length of 250 mm
Temperatures from 5 °C (9 °F) above ambient to 65 °C (149 °F).
The column base can be swiveled outwards to any position between 0° and 180°.
In the 0° "Home" position, the column base is located directly above the sample manager
and can be connected to an optional optical detector.
In the 180° "away" position, the analytical column can be connected to a mass spectrometer
(on the right-hand side of the system).
The Synapt G2 is a Q-TOF based mass spectrometer with an additional ion mobility cell,
which enables orthogonal separation of ions based on their shape and conformation.
Equipped with an intermediate quadrupole (8k), this highly versatile instrument can be used as a peptide identification only
(LC-MSE data-independent acquisition), but also for denaturation and native MS analysis.
Documents & Downloads
Data sheet: Instruction manual
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Vibration test system
RMSSWR 900 SW 3709 u. TGD 6000
Call
Condition: excellent (used), RMS
Type: SW 3509 + amplifier TGD 6000-000.00 and fan
Test Manager SWR 900
Power amplifier: TGD 6000
Vibration exciter: SW 3709
High-pressure fan HVM 80-100 GL 270
RMS electrodynamic vibration test system:
Technical data system:
Performance data
Max. Vector force sine 7.5 kN
Max. Vector force noise 6.75 kN
Max. Vector force shock 13.1 kN
Frequency range 0 - 3000 Hz
Mass of the vibrating system (Dyn.) 9 kg
Main resonance (unloaded) 2.5 kHz
Max. Amplitude (sine) 18 mm
(noise, shock) 26 mm
Max. speed (sine) 1.5 m/s
(noise, shock) 2.5 m/s
Max. Acceleration sine
vibrating system unloaded 833 m/s²
Additional load 10 kg 394 m/s²
Additional load 30 kg 192 m/s²
Additional load 50 kg 127 m/s²
Max. Acceleration noise
Additional load 30 kg 173 m/s²
Max. Acceleration shock
vibrating system unloaded 1450 m/s²
Additional load 30 kg 335 m/s²
Stray field
Stray field without counter field coil
Dsb Hju Tud Hshigcout
On the table surface 20 mT
120mm above the table surface 7 mT
Stray field with counter field coil
On the table surface 10 mT
120mm above the table surface 2 mT
Vibration isolator
Operating range vertical/ horizontal
Resonant frequency 2.7 Hz
Operating air pressure 5 bar
Pneumatic weight compensation
Max. Weight compensation 250 kg
Operating air pressure 2.3 bar
Cooling Vibration exciter air
min. Cooling air volume 9 m/min
Max. exhaust air temperature (based on room temperature 35°C) 80°C
Power booster air
Heat dissipation to room air 1.5 kw
Emission:
Sound pressure level
1m - distance at a height of 1.6m 105 dBA
Electromagnetic field SW 3709
typ. 1.5 mT ( 50Hz)
typ. 0.5 mT (100Hz)
Electromagnetic field TGD 3000
typ. 150 HT (50Hz)
Dimensions / Weights
Table diameter / insert thread 224mm / M8
Vibration exciter with integrated isolators
970 × 695 x 950 mm (W x D x H)
Weight: 1200 kg
Power amplifier 550 x 700 x 2075 mm (W x D x H)
Weight: 270 kg
Cooling fan 839 x 582 x 900 mm (W x D x H)
Weight: 80 kg
Connection values:
Mains voltage +6/-10% 3 x 400V, 50Hz
Connected load 18 KVA
Power consumption (sweep mode sine wave) 12 kW
Total weight approx. 2000 kg
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Temperature test chamber 1540 liters
VötschVT³ 4150 -40°C bis +180°C
Call
Condition: excellent (used), Vötsch
Type: VT³ 4150
Vötsch temperature test chamber
Duob Hhigeu Nh Rbjcjt
Air-cooled
Rated voltage: 3/N/PE AC, 400 V ±10 %, 50 Hz
Rated power: 11.5 kW Rated current: 22.0 A
Rate of change: Cooling approx. 3.5 K/min.
Rate of change: Heating approx. 4 K/min.
Temperature test
Temperature range -40°C to + 180°C
Display plan
External dimensions: W x D x H approx. 1390 x 2380 x 1995 mm
Test chamber dimensions: W x D x H approx. 1100 x 1475 x 950 mm
Weight approx. 1020 kg / 1540 liters
Refrigerant R 404A
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Coordinate measuring machine
Hexagon Optiv Performance 442
Call
Condition: good (used), Hexagon
Type: Hexagon Optiv Performance 442
Product description:
The Optiv Performance 442 3D multisensor coordinate measuring machine combines optical and tactile measurements in one system.
The system supports multi-sensor measurements with vision sensor, tactile sensor, TTL laser (Through-The-Lens)
and the innovative chromatic white light sensor (cws).
The basic device with vision sensor can be modularly expanded with all available sensors.
Areas of application:
٠ Use on level ground
٠ Versatile geometry measurements and GD&T analyses with standard accuracy Construction
٠ Design principle:
" Low-vibration granite construction with fixed bridge and movable table
" Integrated substructure with optional vibration dampers
٠ Guides: " Precise mechanical linear guides in all axes
٠ Drives: " DC servomotors, power transmission via backlash-free ball screws in the center of gravity
٠ Length measuring system; " Incremental length measuring system
٠ Resolution; 0.1 pm
Hexagon Optiv 442 multi-sensor measuring device equipped with camera, laser and Renishaw touch probe.
- Measuring range single sensor: 410x410x200mm
- Dimensions: 1232x910x1663mm
- Weight: approx. 940kg
- max. load weight: glass plate 30kg
- Accuracies: U1=1.9 + L/200; U2=2.4 + L/150; U3=2.9 + L/100 (L= measuring length in mm)
- Max. travel speed per axis: 200mm/s
- Camera with 2-stage zoom
Duobju Szpmo Hhigcot
- laser
- LED ring light
- Renishaw 6-fold probe changer
- Renishaw TP200 touch probe
- Monitor operation
- Windows 7 Ultimate evaluation station
- Measuring machine HEXAGON Optiv 442
Electrical connection values:
Voltage 115/230 V ± 10%
Mains frequency 50/60 Hz ± 5 %
Power consumption 1000 VA
Weight: approx. 1100 kg
Condition: second-hand / used
Scope of delivery: (see picture)
(Subject to changes and errors in the technical data and specifications!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Temperature test chamber 210 liters
Vötsch VT 7021 -70°C bis +180°C
Call
Condition: good (used), Vötsch
Type: VT 7021
Air-cooled temperature test chamber
Deb Hsuuf Rnshigcsut
Operating terminal Color touch panel
Microprocessor monitoring and control MINCON/32
independent adjustable temperature limiter tmin / tmax
adjustable software temperature limiter min./max.
RS 232 serial interface
Schuko socket
potential-free contact for test material switch-off
Air-cooled refrigeration unit
1 lockable door, single-handed operation
Calibration of 2 temperature values
Mobile version
1x feed-through, NW 80 mm
2x feed-through, NW 125 mm
Test chamber volume 210 liters
Temperature range -70°C to +180°C
Temperature deviation in time ± 0.2 to ± 0.5 K
Spatial temperature deviation ± 0.5 to ± 1.5 K
Temperature change rate heating 2.5 K/min
Temperature change rate cooling 2.5 K/min
Max. heat compensation 800 W
Test chamber dimensions: Width 560 mm Depth 570 mm Height 630 mm
External dimensions: Width 850 mm Depth 1250 mm Height 1640 mm
Electrical connection: 1/NPE AC 230 V ± 10% 50Hz
Rated power approx. 1.8 kW Rated current 12 A
Refrigerant: R404A and R23
Weight: 355 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Temperature chamber
HeraeusHT/S 7050
Call
Condition: excellent (used), Heraeus temperature chamber
Here we offer a temperature chamber.
Water-cooled
Dujbeu Efm Se Hhigcet
Outside: W x D x H (mm) 1100 x 2200 x 2320
Inside: W x D x H (mm) 800 x 800 x 790
Test chamber volume 500 L
Characteristic values for temperature tests:
Temp. range -70°C to +180°C
Heating speed: 3 K/min
Cooling speed: 2 K/min
Electrical power:
Rated power 15 kW Rated current 26 A
400 V +6/-10% 3/N 50Hz
Weights: 675 kg
Type: HT/S 7050
R404 A and R23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Temperature test chamber
Vötsch VT 4021
Call
Condition: used, Heraeus Vötsch
Type: VT 4021
Heraeus Vötsch temperature test chamber air-cooled
Housing dimensions: Width 850 mm Depth 1250 mm Height 1640 mm
Interior: Width 560 mm Depth 570 mm Height 630 mm
Temperature range -40°C to + 180°C
Temperature deviation in time ±0.2 to ±0.5 K
Spatial temperature deviation ±0.5 to ±1.5 K
Temperature change rate cooling 3.1 K/min
Temperature change rate heating 2.5 K/min
Nominal voltage: 1/N/PE AC 230V±10% 50Hz
Rated power: 1.5 kW Rated current: 7 A
2X side feed-through 90 mm
Refrigerant: R-404A
Dusb Hhieu Hf Hhegcjt
Weight approx. 325 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Climate test chamber 990 liters
WeissWK-1000/40/5 -40°C bis +180°C
Call
Condition: excellent (used), White
Type: WK-1000/40/5
Weiss climatic test chamber with Weiss air-cooled condenser
S!MCON / 32 control unit
Test chamber capacity: approx. 990 liters
Test chamber dimensions: Height 950 mm, width 1100 mm, depth 950 mm,
External dimensions: Height 1995 mm, width 1390 mm, depth 1855 mm,
Data for operation:
Test room lighting Halogen bulb 24V, 50W
Nominal voltage: 3/N / PE AC 400 V ± 10% 50 Hz
Rated power 23 KW
Rated current: 33 A
Data for temperature tests:
Temperature range: -40 to +180 °C
Temperature deviation in time in the center of the usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 2 K
Temperature change rate
Heating: 6.1 K/min
Cooling: 6.7 K/min
Heat compensation max. 5000 W
Data for climate tests
Duob Heu Ap Smshigcjt
Temperature range: +10 to +95 °C
Humidity range: 10 to 98 % r.h.
Temperature deviation in time in the center of the usable space: ± 0.1 to ± 0.3 K
Spatial temperature deviation: ± 0.5 to ± 1 K
Humidity fluctuation over time in the center of the usable space: ± 1 to ± 3 % r.h.
Dimensions incl. feet
Width x depth x height: 1190 x 1120 x 1093 mm
Refrigerant: R404 A 5.2 kg
Weight: approx. 840 kg
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Trust Seal
Dealers certified through Machineseeker

Listing

785 km
Dryer for coating materials
Vötsch LTU 60/60
Call
Condition: excellent (used), Vötsch
Type: LTU 60/60
Heraeus Vötsch dryer for coating materials
Maximum concentration of flammable substances of 40 % of the lower explosion limit (LEL)
Highest temperature of the heating surface above 750 °C
Device description:
Technical data:
Interior (usable space) 0.216 m3
Internal dimensions: Width 600 mm Height 600 mm Depth 600 mm
External dimensions: Total width 796 mm Height 1725 mm Depth 850 mm
Loading / load capacity
Total roller conveyor 55 kg
Loading height above installation floor 820 mm
Weight (net) kg 275
Minimum exhaust air volume flow 96 m3/h
Djb Hhigeun Rrqsceut
Purge time 5-fold air change 90 sec.
Increased recirculation air volume flow 33 m3/h
Total vapor space 0.414 m3
Sound pressure level (according to DIN 45635) < 70 dB(A)
Switch-off temperature
Temperature limiter (TB) fixed setting 300 °C
Temperature selector limiter (TWB) adjustable above nominal temperature 20
Temperature safety class (according to EN 60519-2)
Temperature limiter (TB) 1
Temperature selector limiter (TWB) 2
Nominal temperature 200 °C
Electrical data
Rated voltage / frequency 400V, 3/(N)PE, AC 50/60 Hz
Rated current 12.0 A
Nominal power 6.0 kW
Connected load 7.0 kW
Weight: 275kg
Condition: second-hand / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Vacuum drying oven
HeraeusVT 6025 200°C
Call
Condition: excellent (used), Heraeus
Type: VT 6025
Heraeus Vacutherm vacuum drying oven
Specification jacket heating VT 6025
Temperature (metric) 200 °C
Dimensions, inside (W x D x H): 300 x 307 x 275 mm
External dimensions (W x D x H): 480 x 450 x 600 mm
Duob Hhorm Rihjigcet
Electrical requirements 230 V, 50/60 Hz
Frequency 50/60 Hz
Capacity (metric) 25 l
Heating jacket type without inert gas connection
Voltage 230 V 1.3 kW, 5.9 A
Weight: 58 kg
Condition: second-hand / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Universal tensile testing machine 2000 kg
HaidaHD-B604-S 20 kN
Call
Condition: excellent (used), Haida
Type: HD-B604-S
Sensor: TECSIS load cell
Max. Capacity: 2T / 20 kN
Unit: G, kg, N, LB (adjustable)
Resolution: 1/250,000
Accuracy: ± 0.5%
Max. Stroke: 700 mm (without fixture)
Test speed: 0.1-500mm/min (adjustable)
Voltage: 220V AC ± 10%, 50/60Hz
Clamping jaws: 0-7 mm
Dujber Ixq Rs Hhigcjt
Weight: approx. 175 kg
Dimensions (WxDxH): 88 x 50.5 x 150 cm
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Temperature test chamber 600 liters
CTST-70/600 -70°C bis 180°C
Call
Condition: excellent (used), CTS
Climatic test chamber T-70/600 water-cooled
Temperature range: -70°C to +180°C
Rated voltage: 400V 3/N PE 50 Hz
Rated power: 6.7 kW
Rated current: 10.2 A
Compressor: TFH2480Z/TFH2511Z Refrigerant R23/R404A
Control system:
-Microprocessor-controlled control and monitoring system
Simple, user-friendly terminal built into the door.
-Digital temperature setpoint and actual value display
Simple variation via +/- button
-Digital input for temperature in °C
-PLC compatible
-Up to 100 test programs possible
-RS 232 interface
-2 free switching channels for on-site
test material control
Insert grid:
Stainless steel, contact surface 820 x 710 mm
Load per grid max. 35 kg
Total load with max. grid configuration 100 kg
Cooling unit:
Water-cooled, low-noise, fully hermetic Infinitely variable power adjustment
through electronic monitoring and control system,
environmentally friendly refrigerant R404A/R23
Temperature tests:
Temperature range -70 °C to+ 180 °C
Temperature deviation ±0.1 to 10.3 K in time
Rate of temperature change
according to DIN 50 011, part 12 measured in the center of the test room
Heating 2.5 K/min
Cooling 2 K/min
Heat radiation max. 1500 W at +20°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400 V, without test material, without irradiation and without additional equipment.
Dimensions:
Test volume 600 liters
Test chamber dimensions 850 x 830 x 850 mm (W x Dx H)
External dimensions 1050 x 1850 x 1900 mm (W x DxH)
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 6.7 kW
Rated current: 10.2 A
Protection class IP 22
Condensate drain unpressurized R 1/2" internal thread
Sound pressure level < 62 dB(A)
Weight approx. 400 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
Dujb Hovaxq Njhigcet
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
We make the search easier for you
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Measuring & testing equipment (1,325)
Search Machineseeker now with more than 200,000 used machines:This may be of interest to you

Find out now
+44 20 806 810 84
+44 20 806 810 84
Create listing
*per listing / month