Technical details
- Clamping force:
- 1,600 kN
Details about the offer
- Listing ID:
- A21597763
- Reference number:
- DE-INJ-ARB-2015-00004
- Update:
- 26.03.2026
Description
This 6-axis Arburg Allrounder 520 S 1600-290 / 290 was manufactured in 2015. It features a highly wear-resistant thermoplastic cylinder with a 30 mm diameter and a drive unit powered by a 30 kW motor. The machine is equipped with advanced control systems for both injection units and supports multi-component processing. If you are looking to get high-quality injection moulding capabilities, consider the Arburg Allrounder 520 S 1600-290 / 290 hydraulic injection moulding machine we have for sale. Contact us for further details.
• Injection units and plasticizing
• 1st injection unit:
• Complete thermoplastic cylinder, 30 mm, highly wear-resistant
• Nozzle contact force controlled, programmable
• aXw Control ScrewPilot
• 2nd injection unit:
• 2nd injection unit 290, vertical
• Complete thermoplastic cylinder, 30 mm, highly wear-resistant
• Open nozzle 30 mm with nozzle tip; extended nozzle tip +20 mm; radius 15
• Heating band for open nozzle
• Nozzle contact force controlled, programmable
• aXw Control ScrewPilot
• Standard worm gear coupling; coupling geometry: double-sided
• Multi-component processing; parting line setup on short runners for 2nd injection unit
• Injection closing with mold (“flying injection”)
• Drive, hydraulics, and cooling
• Drive unit with 30 kW motor
• 65 l/min charging flow rate
• Pressure accumulator module, 64 l storage volume (max. 230 bar); accumulator drive
• Continuous oil cooling and filtration; increased cooling capacity
• Machine cooling circuits controlled
• Clamping system, ejector, and core pulls
• Clamping plate set; central Ø 125 mm
• Minimum installation height 450 mm (extended)
• Ejector pressure P/Q controlled (requires T2); ejector cross
• Core pulls:
• Core pull 1 simultaneous movement (P/Q controlled, programmable)
• Core pull 2 simultaneous movement (P/Q controlled, programmable)
• Core pull 3 simultaneous movement (P/Q controlled, programmable)
• Pneumatic core pull control 4 incl. pressure reducer
• Electric core pull control 1 (requires VE 436/00)
• Tool pneumatics/hydraulics connections
• Electrical connection pneumatic NVD 1 (in tool)
• Electrical connection pneumatic NVD 2 (in tool)
• Electrical and hydraulic connection NVD 3 (in tool)
• Electrical and hydraulic connection NVD 4 (in tool)
• Blow-out device 1 with pressure reducer; connection for blow-out device 2
• Cooling water and mold circuits
• Shut-off valve for cooling water (inlet); shut-off valve for cooling water (inlet 2)
• Cooling water filter 100 µm (inlet)
• 3 cooling water circuits to fixed mold plate; 3 cooling water circuits to moving mold plate
• Basic equipment for 2nd cooling water distributor (manual) with 7 free cooling circuits
• Control and electrics
• Selogica direct control; technology level
• Fuse protection for heating circuits (1–6 with 16 A)
• 15 electrical heating circuits for mold heating
• Boost function for heating circuits (hot runner)
• Upper guard open, raised to safety clearance
• Fault indicator with flashing light
• Operator authorization with chip card (EUROMAP 65)
• Interfaces and connectivity
• Interface for conveyor belt (machine base)
• Prepared for six-axis robot with SELOGICA interface
• Robot interface (EUROMAP 67), 50-pin
• Emergency stop interface (24-pin, 2-channel)
• Basic equipment for electric axis control
• Host computer interface OPC-UA
• Temperature control unit interface (20 mA); temperature control cable HB-THERM
• Serial printer interface USB; external USB keyboard interface
Nsdpfx Aeyxdwdjbvjcp
• Injection units and plasticizing
• 1st injection unit:
• Complete thermoplastic cylinder, 30 mm, highly wear-resistant
• Nozzle contact force controlled, programmable
• aXw Control ScrewPilot
• 2nd injection unit:
• 2nd injection unit 290, vertical
• Complete thermoplastic cylinder, 30 mm, highly wear-resistant
• Open nozzle 30 mm with nozzle tip; extended nozzle tip +20 mm; radius 15
• Heating band for open nozzle
• Nozzle contact force controlled, programmable
• aXw Control ScrewPilot
• Standard worm gear coupling; coupling geometry: double-sided
• Multi-component processing; parting line setup on short runners for 2nd injection unit
• Injection closing with mold (“flying injection”)
• Drive, hydraulics, and cooling
• Drive unit with 30 kW motor
• 65 l/min charging flow rate
• Pressure accumulator module, 64 l storage volume (max. 230 bar); accumulator drive
• Continuous oil cooling and filtration; increased cooling capacity
• Machine cooling circuits controlled
• Clamping system, ejector, and core pulls
• Clamping plate set; central Ø 125 mm
• Minimum installation height 450 mm (extended)
• Ejector pressure P/Q controlled (requires T2); ejector cross
• Core pulls:
• Core pull 1 simultaneous movement (P/Q controlled, programmable)
• Core pull 2 simultaneous movement (P/Q controlled, programmable)
• Core pull 3 simultaneous movement (P/Q controlled, programmable)
• Pneumatic core pull control 4 incl. pressure reducer
• Electric core pull control 1 (requires VE 436/00)
• Tool pneumatics/hydraulics connections
• Electrical connection pneumatic NVD 1 (in tool)
• Electrical connection pneumatic NVD 2 (in tool)
• Electrical and hydraulic connection NVD 3 (in tool)
• Electrical and hydraulic connection NVD 4 (in tool)
• Blow-out device 1 with pressure reducer; connection for blow-out device 2
• Cooling water and mold circuits
• Shut-off valve for cooling water (inlet); shut-off valve for cooling water (inlet 2)
• Cooling water filter 100 µm (inlet)
• 3 cooling water circuits to fixed mold plate; 3 cooling water circuits to moving mold plate
• Basic equipment for 2nd cooling water distributor (manual) with 7 free cooling circuits
• Control and electrics
• Selogica direct control; technology level
• Fuse protection for heating circuits (1–6 with 16 A)
• 15 electrical heating circuits for mold heating
• Boost function for heating circuits (hot runner)
• Upper guard open, raised to safety clearance
• Fault indicator with flashing light
• Operator authorization with chip card (EUROMAP 65)
• Interfaces and connectivity
• Interface for conveyor belt (machine base)
• Prepared for six-axis robot with SELOGICA interface
• Robot interface (EUROMAP 67), 50-pin
• Emergency stop interface (24-pin, 2-channel)
• Basic equipment for electric axis control
• Host computer interface OPC-UA
• Temperature control unit interface (20 mA); temperature control cable HB-THERM
• Serial printer interface USB; external USB keyboard interface