Used Climate Chamber for sale (5,786)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
785 km
Climate test chamber 990 liters
Weiss –40…+180 °CWK11-1000/40 mit Zander K-MT 2
Call
Condition: excellent (used), Weiss
Model: WK11-1000/40
For sale is a professional Weiss Umwelttechnik WT-WK 1000/40 climate test chamber with integrated Zander K-MT 2 steam humidification unit. This unit is suitable for precise temperature and humidity testing of components, assemblies, and devices. Ideal for applications in industry, development, quality assurance, and research.
Weiss Climate Test Chamber, Water-Cooled
Specifications for Temperature Testing:
- Temperature range: -40°C to +180°C
- Temporal temperature fluctuation in the center of the usable space: ±0.1 to ±0.5 K
- Spatial temperature deviation: ±0.5 to ±2.0 K
- Rate of temperature change:
* Heating: 4 K/min
* Cooling: 3 K/min
Specifications for Climatic Testing:
- Temperature range: +10°C to +95°C
- Humidity range: 10 to 98 % RH
- Temporal temperature fluctuation in the center of the usable space: ±0.1 to ±0.3 K
- Spatial temperature deviation: ±0.5 to ±1 K
- Temporal humidity fluctuation in the center of the usable space: ±1 to ±3 % RH
- Heat compensation:
* In the range from +25°C to +95°C
* At relative humidity up to 90%: 500 W
Specifications for Humidification System:
- Reservoir capacity: 20 L
- Water quality: demineralized
- pH value: 6 to 7
- Conductivity: 5 to 20 µS/cm3
- Water consumption at constant +40°C, 92 % RH: 21/24 h
- Temperature gradient (according to IEC 60068-3-5): 1 to 2 K
Test chamber dimensions: Height: 950 mm, Width: 1100 mm, Depth: 950 mm
External dimensions: Height: 1980 mm, Width: 1385 mm, Depth: 1850 mm
Test chamber volume: approx. 990 liters
Guedpjx Hxkzsfx Ab Uek
Rated voltage: 3/N / PE AC 400 V + 10% 50 Hz
Rated power: 11.5 kW, Rated current: 22.0 A
Refrigerant: R 404A
Weight: 840 kg
For your peace of mind as a buyer, please note the following information:
The following actions are performed on all chambers we offer before sale:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant if necessary
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Technical data subject to change and errors excepted!)
Should you have further questions, we are happy to answer them by phone.
Listing
Borken
777 km
Temperature test chamber Climate test
VötschVTR 7033/S
Call
Year of construction: 1997, condition: good (used), Vötsch VTR 7033/S Temperature Test Chamber
Manufacturer: Vötsch
Type: VTR 7033/S
Item No.: 60885637
Temperature Chamber
Temp. Range: -70°C to +180°C
Line Voltage: 400V
Rated Current: 24A
Rated Power: 9.5 kW
Refrigerant (VK): R 404 A
Refrigerant (TK): R 23
Year of Manufacture: 1997
Gujdpfx Abeuuiv Ij Usk
TK 08
Find more items - new and used - in our shop!
International shipping costs upon request!
Listing
Borken
785 km
Climate test chamber 335 liters with humidity
VötschVCS³ 7034-5 -70°C bis +180°C
Call
Condition: excellent (used), Vötsch
Model: VCS³ 7034-5
Vötsch Climate Test Chamber, Water-Cooled
With temperature change rate of 5 K/min
Specifications for temperature testing:
Temperature range: -70°C to +180°C
Temporal temperature deviation in the center of the usable space: ±0.1 K to ±0.5 K
Spatial temperature deviation: ±0.5 K to ±2.0 K
Temperature change rate:
Heating: 6.8 K/min
Cooling: 6.7 K/min
Specifications for climate testing:
Temperature range: +10°C to +95°C
Temporal temperature deviation in the center of the usable space: ±0.1 K to ±0.3 K
Spatial temperature deviation: ±0.5 K to ±1.0 K
Temporal humidity deviation in the center of the usable space: ±1% to ±3% RH
Humidity range: 10% to 98% RH
(Extended climate range: 2°C/95% RH regulated for a maximum of 2 hours)
Exterior dimensions (W x D x H): 870 x 1700 x 1775 mm
Test chamber dimensions (W x D x H): 580 x 765 x 750 mm
Test chamber volume: approx. 335 liters
Side ports: 50 mm and 125 mm
Operating data:
LED strip 24 V, 6.8 W / 2 x halogen bulbs 24 V, 50 W
Rated voltage: 3/N/PE AC 400 V ±10%, 50 Hz
Rated power: 9 kW Rated current: 20 A
Customer-side fuse: 63 A slow-blow
Refrigerant: R404A / R-23
Weight approx. 570 kg
For your security as a buyer, please note the following:
Gsdox Elt Hopfx Ab Ujuk
The following procedures are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant, if needed
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see image)
(Technical data and information subject to change and errors!)
Further questions can be answered by phone.

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing
Borken
777 km
Walk-in climate test chamber
VötschVSKZ 04/120/S
Call
Year of construction: 1996, condition: excellent (used), Vötsch VSKZ 04/120/S Walk-In Climatic Test Chamber
Manufacturer: Vötsch
Type: VSKZ 04/120/S
Temp. Range: -40°C to +120°C
Line Voltage: 400V
Gsdpfx Abjuuigye Ujuk
Rated Current: 95A
Rated Power: 56 kW
Refrigerant: R 404 A
Year of Manufacture: 1996
External Dimensions: W 2850 x D 4100 x H 3080 mm
SO-01
Find more items - new and used - in our shop!
International shipping costs on request!
Listing
Borken
785 km
Climate test chamber 350 liters with humidity control
CTSC -40/350 -40°C /+180°C
Call
Condition: excellent (used), CTS
Model: C-40/350
Air-cooled climate test chamber
For sale is a professional CTS climate test chamber, model C-40/350. This unit is designed for demanding environmental simulations in industrial applications and is ideal for material testing, electronics, automotive, aerospace, and research.
Temperature Testing:
- Temperature range: -40°C to +180°C
- Temperature deviation: ≤ ±0.3 K over time
- Temperature change rate according to IEC 60068-3-5:
* Heating: 3.5 K/min
* Cooling: 4 K/min
- Heat compensation:
* approx. 3500 W at +20°C
* approx. 2000 W at -20°C
Climate Testing:
- Temperature range: +10°C to +90°C
- Humidity range: 10% to 95% relative humidity
- Dew point range: +5°C to 78°C
- Temperature deviation: ≤ 1.0 K over time
- Humidity deviation: ≤ ±3.0% r.h. over time
The technical data refer to an ambient temperature of +25°C, rated voltage 400V, without test specimen, without heat compensation, and without additional equipment. Options may affect performance data.
Technical Specification:
- Refrigeration unit: air-cooled, low-noise, fully hermetic, variable power control by electronic monitoring and control system, environmentally friendly refrigerant R404A
- Test chamber:
* Floor loading: 150 kg/m²
* Shelving grid: stainless steel, support area 620 x 600 mm
* Max. load per shelf: 35 kg
* Max. total load with maximum shelves: 100 kg
Control System:
- 32-bit controller
- LCD control panel
- Digital display of setpoint and actual values
- Numeric input for setpoints
- Plain-text error messages
Guodpox Ekupofx Ab Ujk
- RS 232 interface
- Ethernet interface
- Free switching channels for external test item control
Dimensions:
- Test chamber volume: 350 liters
- Internal dimensions: Height 750 mm × Width 650 mm × Depth 720 mm
- External dimensions: Height 1800 mm × Width 850 mm × Depth 1640 mm
Operating Data:
- Electrical connection: 400V 3/N, 50 Hz
- Rated power: 7.1 kW
- Rated current: 11.5 A
- Protection class: IP 54
- Sound pressure level: (value not specified)
Discover more used machines
Listing
Borken
777 km
Climate test chamber Temperature test
VötschVC 0150
Call
Condition: excellent (used), Vötsch VC 0150 Climatic Test Chamber 0°C - +90°C
Manufacturer: Vötsch
Type: VC 0150
Climatic Test Chamber
Voltage: 230 V
Rated Power: 1.5 kW
Voltage: 1540 liters
Temperature Range: 0°C to +90°C
Humidity: 10% to 98%
Refrigerant: R 134a
Dimensions: W 950 x D 1100 x H 1475 mm
Microprocessor Controller
Guodsuuikfspfx Ab Uok
List Price: €19,500
KK-09
Find more items - new and used - in our shop!
International shipping costs upon request!
Listing
Borken
785 km
Climate test chamber 5,500 liters (5.5 m³)
CTSCW-60/5,5 -60°C bis +100°C
Call
Condition: excellent (used), CTS CW-60/5.5 – Water-Cooled Climate Test Chamber
The CW-60/5.5 from CTS GmbH (Climatic Test Systems) is a medium-sized, walk-in or drive-in climate chamber designed to perform simultaneous temperature and humidity testing on multiple test specimens.
Device Description:
This climate test chamber enables testing of the functionality and material properties of a test item under temperature and humidity influences.
Efficient air circulation with a high recirculation volume ensures optimal heat transfer to the test items.
The air conditioning compartment is located at the rear of the chamber interior.
The refrigeration units are situated behind the chamber in a separate frame, providing good accessibility.
Control systems are housed in a separate control cabinet, with the operating panel integrated into the cabinet door.
Guodpfx Asx Eaxbjb Usk
For dehumidification of the test chamber, the system includes a self-regenerating compressed air dryer.
An integrated blower allows the test chamber to be flushed with fresh air.
Technical Specifications:
Temperature Testing:
• Temperature range: -60 °C to +100 °C
• Temperature deviation: ±0.5 to 1 K over time
• Rate of temperature change (measured in supply air, linear with specimen and radiant heat):
- Heating: 2 K/min from -40 °C to +85 °C
- Cooling: 2 K/min from +85 °C to -40 °C
Climatic Testing:
• Temperature range: +10 °C to +90 °C
• Humidity range: 10% to 95% relative humidity
• Dew point range: +5 °C to +89 °C
• Temperature deviation: ±0.5 K over time
• Humidity deviation: ±1 - ±3% r.h. over time
All technical values refer to an ambient temperature of +25 °C, nominal voltage 400 V, without test specimens, without radiant load, and without ancillary equipment.
Dimensions:
Internal (Test/Clear Space): Volume approx. 5,500 liters (5.5 m³);
Internal dimensions (approx.): Height ~2,000 mm, Width ~2,000 mm, Depth ~1,400 mm (slight variation depending on configuration)
External: Height ~2,300–2,500 mm, Width ~2,300–2,600 mm, Depth ~1,700–2,200 mm (depending on doors, frame, accessories, etc.)
Operating Data:
• Power supply: 400 V +6/-10%, 3/N, PE, 50 Hz
• Rated power: 58.3 kW (incl. 5 sockets)
• Rated current: 86.0 A
• Protection class: IP 54
Technical Features:
• Refrigeration unit: water-cooled, low-noise, semi-hermetic, stepless capacity control via electronic monitoring and control system
• Refrigerants: environmentally friendly R23 / R404A
Remarks:
• Inspection possible by prior arrangement (location: 46325 Borken)
• Shipping by freight carrier available – costs and arrangements on request
• Scope of delivery: (see image)
(Subject to modifications and errors in the technical data and information.)
For further questions, feel free to contact us by phone.
Listing
Borken
777 km
Climate test chamber Temperature test
VötschVCS 4100
Call
Condition: good (used), Vötsch VCS 4100 Climatic Test Chamber -40°C to +180°C
Guodpjuuiygofx Ab Uek
Manufacturer: Vötsch
Type: VCS 4100
Temp. Range: -40°C to +180°C
Line Voltage: 400 V
Rated Current: 17 A
Rated Power: 11 kW
Refrigerant: R404A
KK-07
Find more items - new and used - in our shop!
International shipping costs upon request!
Listing
Borken
785 km
Climate test chamber 5,500 liters (5.5 m³)
CTSCW-60/5,5 -60°C bis +100°C
Call
Condition: excellent (used), CTS CW-60/5.5 – Water-Cooled Climate Test Chamber
The CW-60/5.5 from CTS GmbH (Climatic Test Systems) is a medium-sized, walk-in or drive-in climate chamber designed to perform simultaneous temperature and humidity testing on multiple test specimens.
Device Description:
This climate test chamber enables testing of the functionality and material properties of a test item under temperature and humidity influences.
Efficient air circulation with a high recirculation volume ensures optimal heat transfer to the test items.
The air conditioning compartment is located at the rear of the chamber interior.
The refrigeration units are situated behind the chamber in a separate frame, providing good accessibility.
Control systems are housed in a separate control cabinet, with the operating panel integrated into the cabinet door.
For dehumidification of the test chamber, the system includes a self-regenerating compressed air dryer.
An integrated blower allows the test chamber to be flushed with fresh air.
Technical Specifications:
Temperature Testing:
• Temperature range: -60 °C to +100 °C
• Temperature deviation: ±0.5 to 1 K over time
• Rate of temperature change (measured in supply air, linear with specimen and radiant heat):
- Heating: 2 K/min from -40 °C to +85 °C
- Cooling: 2 K/min from +85 °C to -40 °C
Climatic Testing:
• Temperature range: +10 °C to +90 °C
• Humidity range: 10% to 95% relative humidity
• Dew point range: +5 °C to +89 °C
• Temperature deviation: ±0.5 K over time
• Humidity deviation: ±1 - ±3% r.h. over time
All technical values refer to an ambient temperature of +25 °C, nominal voltage 400 V, without test specimens, without radiant load, and without ancillary equipment.
Dimensions:
Gsdpjx Eabpefx Ab Usuk
Internal (Test/Clear Space): Volume approx. 5,500 liters (5.5 m³);
Internal dimensions (approx.): Height ~2,000 mm, Width ~2,000 mm, Depth ~1,400 mm (slight variation depending on configuration)
External: Height ~2,300–2,500 mm, Width ~2,300–2,600 mm, Depth ~1,700–2,200 mm (depending on doors, frame, accessories, etc.)
Operating Data:
• Power supply: 400 V +6/-10%, 3/N, PE, 50 Hz
• Rated power: 58.3 kW (incl. 5 sockets)
• Rated current: 86.0 A
• Protection class: IP 54
Technical Features:
• Refrigeration unit: water-cooled, low-noise, semi-hermetic, stepless capacity control via electronic monitoring and control system
• Refrigerants: environmentally friendly R23 / R404A
Remarks:
• Inspection possible by prior arrangement (location: 46325 Borken)
• Shipping by freight carrier available – costs and arrangements on request
• Scope of delivery: (see image)
(Subject to modifications and errors in the technical data and information.)
For further questions, feel free to contact us by phone.
Listing
Borken
785 km
Climate test chamber 5,500 liters (5.5 m³)
CTSCW-60/5,5 -60°C bis +100°C
Call
Condition: excellent (used), CTS CW-60/5.5 – Water-Cooled Climate Test Chamber
The CW-60/5.5 from CTS GmbH (Climatic Test Systems) is a medium-sized, walk-in or drive-in climate chamber designed to perform simultaneous temperature and humidity testing on multiple test specimens.
Device Description:
This climate test chamber enables testing of the functionality and material properties of a test item under temperature and humidity influences.
Efficient air circulation with a high recirculation volume ensures optimal heat transfer to the test items.
The air conditioning compartment is located at the rear of the chamber interior.
The refrigeration units are situated behind the chamber in a separate frame, providing good accessibility.
Control systems are housed in a separate control cabinet, with the operating panel integrated into the cabinet door.
For dehumidification of the test chamber, the system includes a self-regenerating compressed air dryer.
An integrated blower allows the test chamber to be flushed with fresh air.
Technical Specifications:
Temperature Testing:
• Temperature range: -60 °C to +100 °C
• Temperature deviation: ±0.5 to 1 K over time
• Rate of temperature change (measured in supply air, linear with specimen and radiant heat):
- Heating: 2 K/min from -40 °C to +85 °C
- Cooling: 2 K/min from +85 °C to -40 °C
Climatic Testing:
• Temperature range: +10 °C to +90 °C
• Humidity range: 10% to 95% relative humidity
• Dew point range: +5 °C to +89 °C
• Temperature deviation: ±0.5 K over time
Gsdpfox D Abpex Ab Ujuk
• Humidity deviation: ±1 - ±3% r.h. over time
All technical values refer to an ambient temperature of +25 °C, nominal voltage 400 V, without test specimens, without radiant load, and without ancillary equipment.
Dimensions:
Internal (Test/Clear Space): Volume approx. 5,500 liters (5.5 m³);
Internal dimensions (approx.): Height ~2,000 mm, Width ~2,000 mm, Depth ~1,400 mm (slight variation depending on configuration)
External: Height ~2,300–2,500 mm, Width ~2,300–2,600 mm, Depth ~1,700–2,200 mm (depending on doors, frame, accessories, etc.)
Operating Data:
• Power supply: 400 V +6/-10%, 3/N, PE, 50 Hz
• Rated power: 58.3 kW (incl. 5 sockets)
• Rated current: 86.0 A
• Protection class: IP 54
Technical Features:
• Refrigeration unit: water-cooled, low-noise, semi-hermetic, stepless capacity control via electronic monitoring and control system
• Refrigerants: environmentally friendly R23 / R404A
Remarks:
• Inspection possible by prior arrangement (location: 46325 Borken)
• Shipping by freight carrier available – costs and arrangements on request
• Scope of delivery: (see image)
(Subject to modifications and errors in the technical data and information.)
For further questions, feel free to contact us by phone.
Listing
Borken
785 km
Climate test chamber 11,000 liters (11 m³)
CTSCW-60/11 -60°C bis +90°C
Call
Condition: excellent (used), CTS
CTS CW-60/11 – Water-Cooled Climate Test Chamber
The CW-60/6 from CTS GmbH (Climatic Test Systems) is a medium-sized, walk-in or drive-in climatic chamber designed for performing temperature and humidity testing on multiple specimens simultaneously.
Device Description
This climate test cell enables functional or material property testing of a specimen under the influence of temperature and humidity. Efficient air circulation with a high recirculated air volume ensures optimal transfer conditions for the test specimens. The air conditioning section is located at the rear of the inner chamber.
The system components are mounted in a separate frame behind the chamber for easy accessibility. Control electronics are housed in a discrete control cabinet, with the control panel integrated into the cabinet door.
For dehumidification, the chamber is equipped with a self-regenerating compressed air dryer. Fresh air flushing of the test chamber can be performed via a blower.
Technical Performance Data:
Temperature Testing:
- Temperature range: –60 °C to +90 °C
- Temporal temperature deviation: ±0.5 to 1 K
- Spatial temperature deviation: ±1 K at 200 mm wall clearance
- Temperature ramp rate (supply air, linear):
Heating: 2 K/min from –40 °C to +85 °C
Cooling: 2 K/min from +85 °C to –40 °C
Climatic Testing:
- Temperature range: +10 °C to +95 °C
Gedsx Ankyjpfx Ab Ueuk
- Humidity range: 10 % to 95 % RH
- Dew point range: +5 °C to +89 °C
- Temporal temperature deviation: ±0.5 K
- Temporal humidity deviation: ±2 to ±5 % RH
- Without thermal radiation
- At equilibrium state
Technical data assume ambient temperature of +25 °C, rated voltage 400 V, without test load, without radiation, and without additional equipment.
Dimensions:
Internal dimensions (test chamber / usable volume):
- Volume: approx. 11,000 liters (11 m³)
- Approximate internal dimensions: Width: 2,100 mm, Depth: 2,530 mm, Height: 2,200 mm (may vary slightly depending on configuration)
External dimensions: Width: 2,700 mm, Depth: 5,200 mm, Height: 2,520 mm (depending on door, frame, accessories, etc.)
Operating Data:
- Rated power: 84.4 kW
- Rated voltage: 400 V 3/N 50 Hz
- Rated current: 131.4 A
Technical Specifications:
- Refrigeration unit: water-cooled, low-noise, semi-hermetic, continuously variable output via electronic control and monitoring system
- Eco-friendly refrigerants: R 23 / R 404 A
- Weight: 6,000 kg
Notes:
- Inspection by appointment possible (46325 Borken)
- Shipping via freight carrier available – Costs & arrangements on request
- Scope of delivery: (see picture)
(Technical data subject to change and errors excepted.)
Further questions can be answered by phone.
Listing
Borken
785 km
Climate test chamber 11,000 liters (11 m³)
CTSCW-60/11 -60°C bis +90°C
Call
Condition: excellent (used), CTS CW‑60/11 – Water-Cooled Climatic Test Chamber
The CW‑60/6 from CTS GmbH (Climatic Test Systems) is a medium-sized, walk-in or drive-in climatic chamber designed for conducting temperature and humidity tests on multiple test specimens simultaneously.
Device Description:
This climatic test chamber allows you to evaluate the functionality or material properties of your test items under varying temperature and humidity conditions. Efficient air circulation with a high recirculation rate ensures optimal climatic transfer to the test specimens. The air treatment chamber is located at the rear of the interior space. Equipment assemblies are installed in a separate frame behind the unit, providing easy access. The control system is housed in a separate control cabinet, with the operating panel integrated into the cabinet door. For dehumidification, the test chamber features a self-regenerating compressed air dryer. A fan can be used to flush the test chamber with fresh air.
Technical Specifications:
Temperature Tests:
- Temperature range: –60 °C to +90 °C
- Temporal temperature deviation: ±0.5 to 1 K
- Spatial temperature deviation: ±1 K at 200 mm from wall
- Rate of temperature change (supply air, linear):
- Heating: 2 K/min from –40 °C to +85 °C
- Cooling: 2 K/min from +85 °C to –40 °C
Climatic Tests:
- Temperature range: +10 °C to +95 °C
- Humidity range: 10 % to 95 % RH
- Dew point range: +5 °C to +89 °C
- Temporal temperature deviation: ±0.5 K
- Temporal humidity deviation: ±2 – ±5 % RH
- Without heat radiation
- In steady-state conditions
All technical data refer to an ambient temperature of +25 °C, rated voltage of 400 V, without test specimens, no thermal radiation, and without additional equipment.
Dimensions:
Internal (test chamber/usable space):
- Volume: approx. 11,000 liters (11 m³)
- Internal dimensions (approx.): Width: 2100 mm, Depth: 2530 mm, Height: 2200 mm (may vary slightly by configuration)
External dimensions: Width: 2700 mm, Depth: 5200 mm, Height: 2520 mm (depending on door, frame, accessories, etc.)
Operating Data:
- Rated power: 84.4 kW
Gsdpfx Abex Anipe Uouk
- Rated voltage: 400 V 3/N 50 Hz
- Rated current: 131.4 A
Technical Design:
- Refrigeration unit: water-cooled, low noise, semi-hermetic, stepless capacity control via electronic monitoring and control system, eco-friendly refrigerants R 23 / R 404 A
Weight: 6000 kg
Notes:
- Viewing by appointment (46325 Borken)
- Shipping by freight carrier possible; costs & arrangement upon request
- Delivery scope: (see photo)
- (Subject to change and error in technical specifications—information provided without obligation.)
- For further questions, please contact us by phone.
Listing
Borken
785 km
Climate test chamber 600 liters with humidity
WeissWK3-600/0-M -5°C bis +90°C
Call
Condition: excellent (used), Weiss
Model: WK3 600/0-M
Weiss Climate Test Chamber, Water-Cooled
Series: WK3-../0
with SIMPAC* Controller
Test chamber volume: approx. 600 liters
Test chamber dimensions: Height 950 mm, Width 800 mm, Depth 800 mm
External dimensions: Height 1995 mm, Width 1090 mm, Depth 1660 mm
Operating data:
Test chamber lighting: LED 24 V, 6.8 W / Halogen bulb 2 x 24V, 50W
Rated voltage: 1/N / PE AC 230 V ±10% 50 Hz
Rated power: 2.3 kW
Rated current: 10 A
Site-provided fuse: 16 A slow-blow
Control cabinet and operator panel protection class: IP 54
Maximum heat emission to environment: 1200 W
Sound pressure level:
Measured at a distance of 1m from the front, at a height of 1.6m: 46 dB(A)
Data for temperature tests:
Temperature range: -5°C to +90°C
Temporal temperature deviation at center of usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1 K
Temperature gradient (according to IEC 60068-3-5)
Temperature change rate:
Heating 0.6 K/min
Cooling 0.3 K/min
Heat compensation at +20°C to +50°C: 200 W
Data for climatic tests:
Temperature range: +10°C to +90°C
Gsdpjx Ag R Sefx Ab Ujuk
Dew point range: 4 to +89.5°C
Humidity range: 10 to 98 % r.h.
Temporal temperature deviation at center of usable space: ± 0.1 to ± 0.3 K
Spatial temperature deviation: ± 0.5 to ± 1 K
Temporal humidity deviation: +1 to +3 % r.h.
Refrigerant: R-404A
Weight: 610 kg
For your safety as a buyer, please note the following information!
The following points are carried out in advance on our offered chambers:
1. Functionality check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used
Scope of delivery: (See image)
(Technical data and information subject to change and errors!)
We are happy to answer any further questions you may have by phone.
Listing
Borken
785 km
Walk-in climate chamber with humidity
RS-SimulatorenKKM 40/45S
Call
Condition: excellent (used), Here we offer you a walk-in climate chamber.
Manufacturer: RS Simulators, water-cooled
The chamber can be dismantled into 3 parts for transport (bolted)
Temperature range: -30°C to +100°C
Refrigerant: 20kg R-404A + 20kg R-452A
External dimensions: approx. width 3920 mm, depth 7350 mm, height 2600 mm
Test room dimensions: approx. width 3500 mm, depth 5400 mm, height 2110 mm
Electrical data: 68kW nominal power
Voltage: 3x400V/PE; Current: 135A
Type: KKM 40 / 45 S
Further technical data will follow!
For your security as a buyer, the following information!
Gusdpfxjqw U Aas Ab Usk
The following points are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data and information are reserved!)
We are happy to answer further questions by phone for you.
Listing
Borken
785 km
Climate chamber with humidity 34 liters
WeissWKL 34/60 -60°C bis 150°C
Call
Condition: excellent (used), White
Type: WKL 34/60
Weiss air-cooled climate chamber
Refrigerant converted to R-452A
-60°C to 150°C
Room volume: 34 liters
Entry port installed in basic equipment:
R1 NW 50 mm
L1NW 120 mm
Internal dimensions: Height 310 mm Width 324 mm Depth 300 mmm
External dimensions: Height 1740 mm Width 630 mm Depth 970 mmm
Characteristic values for temperature tests:
Temperature range -60 to +150 °C
Temperature differences in steady state, according to IEC 60068-3-5)
Temperature fluctuation over time in the center of the usable space ± 0.3 to ± 1 K ± 1 to ± 2 K
Temperature deviation in space (corresponds to temperature gradient) 2 to 4
Temperature change rate (according to IEC 60068-3-5)
Heating 2.5 K/min
Godpfjtr Dinox Ab Ujuk
Cooling 3 K/min
Heat compensation max. 550 W
Characteristic values for climate tests:
Temperature range +10 to +95 °C
Humidity range 10 to 98 %r.H.
Temperature and humidity differences (in steady state, according to IEC 60068-3-5)
Temperature fluctuation over time in the center of the usable space ± 0.3 to ± 0.5 K
Temperature deviation in space ± 0.5 to ± 1.5
(corresponds to temperature gradient) 1 to 3
Humidity fluctuation over time in the center of the usable space ± 3 to ± 5 %RH
Data for operation:
Test room lighting Halogen bulb 12V, 20W
Nominal voltage 1/N / PE AC 230 V ± 10 % 50 Hz
Rated power 2.5 kW
Rated current 11 A
On-site fuse 16A slow-blow
Heat dissipation air-cooled test chambers
Max. Heat dissipation to surroundings 1700 W
Refrigerant: R-452A / R23
Weight: 140 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
785 km
Climate chamber -75°C / +180°C with humidity
TIRATCC 7120
Call
Condition: excellent (used), TIRA
Type: TCC 7120
Temperature range: -75°C / +180°C
Air-cooled condenser
Temperature stability (over time and in the center of the usable space) ±0.1°C ... ±0.3 °C
Maximum temperature change rate
Heating: 4°C/min
Cooling: 3°C/min
Humidity range: 10% to 98% relative humidity
Humidity stability over time ±1% ÷ ±3%
Dew point range for long-term tests +2 / +94 °C
Dew point range for short-term tests -20 / +2 °C
External dimensions (L x D x H) 1320 x 2235 x 2137 mm
Test space dimensions (L x D x H) 1000 x 1130 x 1020 mm
Test chamber volume: approx. 1152 liters
Max. load per grid: 50 kg
Maximum floor load of the test chamber: 100 kg
Refrigerants: R404A and R23
Power supply: 400V + 6%/-10% / 50Hz / 3P+N+PE
Rated power: 10.2 max. 17.5 kW
Rated current: 19.5 max. 32.0 A
Noise level: approx. 80 dB(A)
Gedjwfddwjpfx Ab Uouk
Weight: 1180 kg
For your safety, the following information is provided as a buyer!
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leakage test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
785 km
Salt spray chamber / climate cycling device
WeissSC/KWT 450
Call
Condition: excellent (used), Weiss
Type: SC/KWT 450
Salt Spray Chamber
Technical Data:
Test chamber volume: 450 liters
Maximum load: 100 kg
Brine reservoir: 180 liters
External dimensions: Height 920 mm, Width 1930 mm, Depth 800 mm
Test chamber dimensions: Height 740 mm, Width 850 mm, Depth 570 mm
Applications:
Corrosion tests:
Gusdpew Hz Trjfx Ab Uok
Salt spray test: Ambient temperature up to +50°C
Condensation water test: Ambient temperature up to +45°C
Humidifier +75°C
Temperature stability
The temporal temperature deviation is ± K.
Voltage: 1/N/PE AC 230V ±10% 50Hz
Rated power: 2.0 kW Rated current: 8.5 A
Combination:
Salt spray test SS: DIN 50021
Condensation water test KFW: DIN 50017
Standard climate (ventilation): DIN 50014
Weight: 180 kg
Condition: used
Scope of delivery: (See picture)
(Subject to technical modifications and errors! All provided data are subject to change!)
For further questions, please feel free to contact us by phone.
Listing
Borken
785 km
Climate test chamber with humidity
WeissWK3-340/70 -70°C bis +180°C
Call
Condition: excellent (used), Type: WK3-340/70
Weiss Climate Test Chamber, Water-Cooled
Control Unit: “Touch Panel”
All control and operating commands can be triggered simply by touching the function symbols on the “Touch Panel” control unit.
Adjustable Feet
The test chamber is equipped with adjustable feet to compensate for uneven floors and to ensure sufficient ventilation of the machine section.
Feed-Throughs
The test chamber is fitted with feed-throughs on both the left and right sides. These allow measuring cables and test devices to be routed into the test chamber. Feed-throughs included in the basic configuration:
R1: nominal width 125 mm
L1: nominal width 85 mm
Volume: 335 liters
Test Chamber Internal Dimensions:
Height: 750 mm, Width: 580 mm, Depth: 765 mm
External Dimensions:
Height: 1775 mm, Width: 870 mm, Depth: 1600 mm
Specifications for Temperature Tests:
Minimum temperature: –72°C
Maximum temperature: +180°C
Temperature deviation over time: ± 0.1 to ± 0.5 K
Temperature uniformity spatially: ± 0.5 to ± 1.5 K
Temperature change rate, cooling: 3 K/min
Temperature change rate, heating: 3 K/min
Gjdexmg Sdopfx Ab Uouk
Specifications for Climate Tests:
Temperature range: +10°C to +95°C
Dew point range: –3°C to +94°C
Humidity range: 10 to 98% RH
Temperature deviation over time: ± 0.1 to ± 0.3 K
Temperature uniformity spatially: ± 0.5 to ± 1 K
Humidity deviation over time: ± 1 to ± 3% RH
Operating Data:
Test chamber lighting: Halogen bulb 2 x 24V, 50W
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal current: 16 A
Nominal power: 4.9 kW
Protection: 16 A slow-blow fuse, to be provided onsite
Refrigerant: R-452A/R23
Weight: approx. 585 kg
For your security as a buyer, please note the following information!
The following procedures are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Technical data, information and specifications are subject to change and errors.)
If you have any further questions, we will be happy to assist you by phone.
Listing
Borken
785 km
Climate chamber
VötschVC³ 4060
Call
Condition: excellent (used), Heraeus Vötsch climatic test chamber
Here we offer a Heraeus Vötsch climatic test chamber.
Heraeus Vötsch climatic test chamber with humidity (water cooled)
Test chamber dimensions: Width 800 mm x depth 800 mm x height 950 mm
Housing dimensions: Width 1090 mm x depth 1960 mm x height 1995 mm
Gjdpfjmt Du Tjx Ab Ujuk
Characteristic values for temperature tests:
Temperature range: -45°C to +180°C
temporal ± 0.1 to ± 0.5 K
spatially ± 0.5 to ± 1.5 K
Temperature change rate according to IEC 60068-3-5
heating: 4.0 K/min
cooling: 3.0 K/min
Characteristic values for climatic tests:
Temperature range: -45°C to +180°C
Temperature deviation in steady state, according to IEC 60068-3-5
depending on test room temperature
Temperature range: - 10°C to +95°C
temporal ± 0.1 to ± 0.3 K
spatially ± 0.5 to ± 1.0 K
Humidity range: 10 % to 98 % r. h.
Humidity deviation temporal +1 to ±3
Electrical connection:
Rated voltage: 3/N/PE AC 400V±10% 50Hz
Rated power: 7,8 kW
Rated current: 15,0 A
Refrigerant R452A
Test chamber capacity: approx. 600 liters
Weight: approx. 620 kg net
Type: VC³ 4060
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.Condition: gebraucht / usedScope of delivery: (See picture)
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
785 km
Climate test chamber 335 liters with humidity
VötschVCS 7034-5 -70°C bis +180°C
Call
Condition: good (used), Type: VCS 7034-5
Climatic Test Chamber, Water-cooled
Vötsch VCS 7034-5
Test Volume: 335 liters
Specifications for Temperature Testing:
Temperature range: -70 to +180°C
Time-based temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4 K
Change rate:
Cooling: 6.7 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3000 W / at -20°C: 3000 W
Temperature calibration points: +23°C and +80°C
Specifications for Climate Testing:
Temperature range: +10 to +95°C
Time-based temperature deviation: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Time-based humidity deviation: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climate calibration points: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Guodpexmhycjfx Ab Uok
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10 kW
Rated current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerants: R452A / R-23
Important safety information for buyers:
The following procedures are carried out on our offered chambers prior to sale:
1. Functional inspection and replacement of necessary components
2. Recharging with legally compliant refrigerant, if required
3. Leak test with certificate
4. After successful testing, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Subject to technical modifications and errors. All information is non-binding!)
For further questions, please do not hesitate to contact us by phone.
Listing
Borken
785 km
Climate test chamber with humidity, 335 liters
VötschVC 7034 -70 bis 180°C
Call
Condition: excellent (used), Vötsch
Type: VC 7018
Vötsch Climatic Test Chamber VC 7018 Water-Cooled
Touch Panel Control Unit
On the touch panel control unit, all control and operating commands can be triggered by simply touching the function symbols.
Adjustable Feet
To compensate for uneven floors and ensure adequate ventilation of the machine section,
the test chamber is equipped with adjustable feet.
Ports
Gusdpfxexugire Ab Ujk
The test chamber is equipped with port holes on the right and left sides.
These allow measurement cables and test equipment to be routed into the test chamber.
Feedthrough included in standard equipment
R1: NW 125 mm
L1: NW 50 mm
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1280 mm x Height 1745 mm
Characteristics for temperature tests:
Temperature range: -70°C to +180°C
Temperature ±0.1 to ±0.5 K
Spatial ±0.5 to ±2.0 K
Temperature change rate according to IEC 60068-3-5
Heating: 4 K/min
Cooling: 2.3 K/min
Characteristics for climatic tests:
Temperature range: -10°C to +95°C
Humidity range: 10% to 98% r.h. F.
Temperature deviation over time in the center of the usable space ± 0.1 to ± 0.3 K
Temperature deviation over space ± 0.5 to ± 1.0 K
Temperature gradient 1 to 2 K
Humidity deviation over time in the center of the usable space ± 1 to ± 3 %RH
Electrical connection:
Nominal voltage: 3/N/PE AC 400V ±10 50Hz
Nominal power: 5.9 kW
Nominal current: 12.0 A
Connection cable: 3.5 m
Fuse protection: 16 A slow-blow, provided by the customer
Refrigerants: R-404A and R-23
Test chamber capacity: approx. 190 liters
Weight: approx. 460 kg net
For your safety, the following information is provided as a buyer!
The following steps are performed on our offered chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
785 km
Climate test chamber with humidity
WeissSB2/500/80 -75°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss climate test chamber.
Designation: SB2/500/80 water cooled
Cold-heat operation: -75°C ...+180°C
Climatic operation: +10...+95°C
Humidity range: 10...98 % r. h.
Temperature constancy, temporally ± 0.2K
Humidity constancy: ±1 r.F.
Temperature rate of change:
Cooling: approx. 1.4 K/min
Heating up: approx. 2.5 K/min
External dimensions: Height 1980 mm, width 1265 mm, depth 1365 mm
Feedthroughs:
left side: ∅ 100 mm
right side: ∅ 50 mm
The connection voltage is:
400V/3Ph+N+PE/ 50 Hz
Power: 10,4 kVA
Weight: approx. 720 kg
Refrigerant R404a / R 23
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Gedpfx Absm Tvzce Uouk
Type: SB2/500/80
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
785 km
Climate test chamber 280 liters
FeutronKPK 200 Typ: 3416/16 +5 °C bis +100 °C
Call
Condition: excellent (used), Here we offer a climatic test chamber.
Air cooled
Nominal test chamber volume: 280 liters
Dimensions
Test chamber outside: 1500 x 2040 x 1075 mm
Fan motor and door disassembled: 1500 x 1940 x 925 mm
test chamber: 720 x 690 x 560 mm
door, clear width: 720 x 690 mm
viewing window, heated: 500 x 600 mm
Temperature range
+5 to +100 C
Gsdpfx Abeiz Tqcj Usuk
heating: 4,0 K /min
Cooling: 0.6 K /min
Climate range +10 to +95 C
Humidity range: 10 to 95 % r.H.
Humidity difference, temporal: ≤ ± 3.0
Water connection humidifier: city water or distilled water 20l reservoir tank.
Mains connection: 400 V 3/N/PE, AC, 50 Hz
Power requirement max : 6,3 kW
Weight : 500 Kg
Type : 3416/16
Refrigerant : R134a
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
785 km
Climate test chamber 335 liters with humidity
VötschVC 4034 -40°C..+180°C
Call
Condition: good (used), Vötsch
Vötsch Climate Test Chamber, Air Cooled
Converted to refrigerant R-452a
Specifications for Temperature Tests:
Temperature range: -40°C to +180°C
Temporal tolerance: ±0.1 to ±0.5 K
Spatial tolerance: ±0.5 to ±1.5 K
Temperature change rate according to IEC 60068-3-5:
Heating: 3.2 K/min.
Cooling: 3.5 K/min.
Specifications for Climate Tests:
Temperature range: -40°C to +180°C
Temporal tolerance: ±0.1 to ±0.3 K
Spatial tolerance: ±0.5 to ±1.0 K
Humidity range: 10% to 98% r.h.
Test chamber dimensions: Width 580 mm x Depth 765 mm x Height 750 mm
Housing dimensions: Width 780 mm x Depth 1758 mm x Height 1800 mm
Electrical connection:
Rated voltage: 3/N/PE AC 400V +6/-10% 50Hz
Rated power: 4.9 kW
Rated current: 9 A
Refrigerant: R-452a
Test chamber volume: approx. 335 liters
Weight: approx. 515 kg net
Important information for you as a buyer!
The following actions are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, recharge with legally compliant refrigerant
3. Leak test with certificate
Gedpfxjxbrkhe Ab Ujuk
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See photo)
(Specifications subject to change and errors excepted!)
If you have further questions, we will be happy to answer them by phone.
Listing
Borken
785 km
Alternating climate chamber
BinderMKF 720 E1 / E1.1
Call
Condition: used, Binder
Type: MKF 720 E1 / E1.1
Air-cooled
The MKF dynamic climate chamber is a specially developed environmental simulation chamber for
industrial materials testing and environmental simulation. Its unprecedented performance far exceeds the capabilities of a conventional heating chamber. It fulfills all the tasks required for materials testing, as well as aging and stress tests.
TECHNICAL DATA:
Housing dimensions:
Gsdpowb D Uuefx Ab Uouk
Width: 1615 mm Height: 2005 mm Depth: 1230 mm
Internal dimensions: Width: 1200 mm Height: 1020 mm Depth: 600 mm
Main technical features of the MKF 720 E1 / E1.1
Temperature range: -40 °C to +180 °C
Humidity range: 10% RH Up to 98% RH
Interior volume: 734 liters
Weight: approx. 590 kg
Refrigerant: R-404A
Power supply: 400 V 3N~ ±10%, 50 Hz
Rated power: 8.0 kW
Rated current: 12 A
Maximum heat compensation: 6500 W
Humidity control: Steam humidification with capacitive sensor
Controller: Intuitive touchscreen with real-time and time-period programming
Data logger: Integrated, with USB readout function
Safety functions: Visual and audible alarm, Class 2 adjustable temperature limiter (DIN 12880)
Condition: Used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
We make it easier for you to find: "climate chamber"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Climate Chamber (5,786)
Search Machineseeker now with more than 200,000 used machines:Browse through the most popular machine descriptions:
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month









































































































































































































