Used Rotating Washing Chamber for sale (10,228)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
785 km
Temperature chamber
WEISSWT11-1000/70/5
Call
Condition: excellent (used), Weiss temperature chamber
Here we offer a Weiss temperature chamber.
Weiss temperature chamber air cooled with Weiss condenser cooler
Test chamber capacity approx. 990 liters
Bljdpfjp Dun Aox Aczjr
Data for temperature tests:
Temperature range -70°C to +180°C
Temperature deviation in time in the center of the chamber ± 0.1 to ± 0.5 K
Temperature deviation spatially ± 0.5 to ± 2.0 K
Temperature gradient (acc. to IEC 60068-3-5) 1 to 4 K
Temperature change rate (according to IEC 60068-3-5)
Heating 5 K/min
Cooling 5 K/min
Heat compensation max. 2750 W
Feedthrough built into basic equipment
R1: NW 125 mm
L1: NW 50 m
Dimensions:
Test chamber dimensions: Width 1100 mm x depth 950 mm x height 950 mm
Housing dimensions: width 1390 mm x depth 1525 mm x height 1995 mm
maximum load (evenly distributed over the surface) of the test chamber floor 150 kg
per insert grate 50 kg
total load of the grate supports 100 kg
Data for operation:
Test room lighting halogen bulb 24V, 50W
Rated voltage 3/N / PE AC 400 V ± 10% 50 Hz
Rated power 27,0 kW
Rated current 42,02 A
Heat output water-cooled test chambers max. heat output to environment 1.3 kW
Noise measurement:
Sound pressure level approx. 64 dB(A)
Refrigerant: ( converted to R-452a )
weight: approx. 960 kg
Type: WT11-1000/70/5
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. function check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
785 km
Temperature test chamber
FeutronTPK 200 Typ: 3416/17
Call
Condition: excellent (used), Feutron temperature test chamber
Here we offer a temperature test chamber.
Feutron temperature test chamber air-cooled
Nominal test chamber volume: 280 liters
dimensions
Test chamber outside: 1500 x 2040 x 1075 mm
Fan motor and door dismantled: 1500 x 1940 x 925 mm
Test chamber: 720 x 690 x 560 mm
Door, clear width: 720 x 690 mm
Viewing window, heated: 500 x 600 mm
Temperature range
-70°C to +180°C
Heating: 4.0 K /min
Cooling: 0.6 K /min
Mains connection: 400 V 3/N/PE, AC, 50 Hz
Max. power requirement: 6.3 kW
Weight: 600 kg
Type: 3416/17
Refrigerant: R507 / R23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Bsdpfx Ajk Scxmoczolr
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
785 km
Test chamber for parametric test
S & A-55°C bis +200°C 4365A
Call
Condition: good (used), Here we offer you a S & A test chamber for parametric testing.
Temperature range
-55 ° C to 200 ° C (LCO2)
-65 ° C to 200 ° C (LN2)
Temperature change rate
15° C / min (Standard Option)
60° C / min (Fast Option)
Stability
± 0.2 ° C (including effects of mains voltage, ambient temperature between
between 15° and 45° C and aging)
Uniformity
± 1.0 ° C Max from -65 ° C to -55 ° C
± 0.5 ° C Max from -55 ° C to + 125 ° C
Bljdocnic Depfx Aczer
± 1,0 ° C Max from + 125 ° C to + 200 º C
Coolant: LCO2
Chamber can be controlled remotely via IEEE bus or
RS232C interface
Weight approx. 61 kg
Type: 4365A
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, details are reserved!)
Further questions we can answer gladly on the phone for you.

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing
Borken
785 km
Climate test chamber 280 liters
FeutronKPK 200 Typ: 3416/16 +5 °C bis +100 °C
Call
Condition: excellent (used), Here we offer a climatic test chamber.
Air cooled
Nominal test chamber volume: 280 liters
Dimensions
Test chamber outside: 1500 x 2040 x 1075 mm
Fan motor and door disassembled: 1500 x 1940 x 925 mm
test chamber: 720 x 690 x 560 mm
door, clear width: 720 x 690 mm
viewing window, heated: 500 x 600 mm
Temperature range
+5 to +100 C
heating: 4,0 K /min
Cooling: 0.6 K /min
Climate range +10 to +95 C
Humidity range: 10 to 95 % r.H.
Humidity difference, temporal: ≤ ± 3.0
Water connection humidifier: city water or distilled water 20l reservoir tank.
Mains connection: 400 V 3/N/PE, AC, 50 Hz
Power requirement max : 6,3 kW
Weight : 500 Kg
Type : 3416/16
Refrigerant : R134a
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Bjdpfx Acoiz Tqcjzelr
Listing
Borken
785 km
Chamber dryer Oven
GFOTyp Ke/SO 2,2 qm 100°C 3208.3319
Call
Condition: excellent (used), Here we offer you a chamber dryer.
Outer dimensions approx.
width: 1.885 mm
depth: 1.200 mm
height: 2.425 mm
Usable space dimensions approx.
width: 1.030 mm
depth: 1,000 mm
Height: 2,100 mm
Usable space: 2.2 m³
Nominal temperature: 100 °C
Working temperature: 85 °C
Heating medium: 3 x 400 V, 50 Hz
Heating capacity: 20 kW
Circulating air volume: 4,500 m³/h / 400 Pa
Motor power: 1,1 kW
Protection class: IP 54
The chamber heating furnace must not be used for flammable or explosive substances.
The chamber heating furnace must not be installed in the Ex-area.
Paternoster device
External dimensions:
Height: 1,880 mm
Width: 809 mm
Depth: 950 mm
support sets: 13 pieces
Pitch: 228 mm
Carrying set width: 354 mm
Carrying set depth: 320 mm
useful height: 135 mm
Power of drive motor: 0.25 kW at 189 Nm
Transport speed: on average 5 m/min.
Blsdpfx Ajgm Hwuoczjr
Payload/carrier set: max. 10 kg
total payload: max. 130 kg
total weight loaded: max. 730 kg
year of construction: 2005
Type: Ke/SO
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, data are reserved!)
Further questions we can answer on the phone for you.
Discover more used machines
Listing
Borken
785 km
Climate chamber Temp. and humidity
EspecPHP-J3 bis +100°C
Call
Condition: excellent (used), Espec
Type: PHP - J3
Technical data:
Air-cooled
Temperature and humidity range Room temperature +10°C to +100°C / 40 to 98% rel. LF
Temperature fluctuation ±0.3 K
Humidity fluctuation ±2.5%
Volume 398 liters
Dimensions:
Internal dimensions: Width 600 mm x height 830 mm x depth 800 mm
External dimensions: Width 1010 mm x height 1690 mm x depth 1273 mm
Mains voltage: 400 VAC 3∅ 50 Hz
Maximum current 400 VAC 8.3 A
Weight: 335 kg
Bsdpfx Aotzbzcjczelr
Scope of delivery: Espec climatic test chamber
The following information is for your safety as a buyer!
The following points are carried out on our chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
785 km
Climate chamber Temp. and humidity
EspecPHP-J3 bis +100°C
Call
Condition: excellent (used), Espec
Type: PHP - J3
Technical data:
Air-cooled
Temperature and humidity range Room temperature +10°C to +100°C / 40 to 98% rel. LF
Temperature fluctuation ±0.3 K
Humidity fluctuation ±2.5%
Volume 398 liters
Dimensions:
Internal dimensions: Width 600 mm x height 830 mm x depth 800 mm
External dimensions: Width 1010 mm x height 1690 mm x depth 1273 mm
Mains voltage: 400 VAC 3∅ 50 Hz
Maximum current 400 VAC 8.3 A
Bljdpstzbz Asfx Aczjr
Weight: 335 kg
Scope of delivery: Espec climatic test chamber
The following information is for your safety as a buyer!
The following points are carried out on our chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
785 km
Climatic chamber
EspecEGNX12-6CWL
Call
Condition: good (used), Espec
Type: EGNX12-6CWL
Espec temperature and climate test chamber air-cooled
Temperature (and humidity) test chamber N series
Power supply:
AC 400/460 V 3-phase 50/60Hz 32A
Temperature range -70 to +180°C
Blsdpfx Aot Nf Upjczer
Humidity range 10 to 95% r. H.
Temperature change rate
Heating 15 °K/min
Cooling 11 °K/min
Internal dimensions W x H x D in mm 600 x 750 x 850
External dimensions W x H x D in mm 889 x 2098 x 1768
Useful volume 380 l
Refrigerant R404A
Weight: 370 kg
The following information is for your safety as a buyer!
The following points are carried out on our chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
785 km
Temperature test chamber 280 liters
FeutronTPK 200 Typ: 3416/17 -70°C bis +180°C
Call
Condition: excellent (used), Feutron
Type: 3416/17
Temperature test chamber Air-cooled
Test chamber nominal volume: 280 liters
Dimensions:
Bedpfxju E N Tie Aczslr
Test chamber outside: width 1540 mm x height 2090 mm x depth 1240 mm
Fan motor and door dismantled: width 1540 mm x height 1940 mm x depth 925 mm
Test chamber: width 720 mm x height 690 mm x depth 560 mm
Door, clear width: width 720 mm x height 690 mm
Viewing window, heated: width 500 mm x height 600 mm
Installation dimensions of the temperature test chamber with doors open
Width 2340 mm x height 2090 mm x depth 2165 mm
Through-hole 2 pieces side wall, left ∅ 100 mm
Temperature range
-70°C to +180°C
Heating: 3.0 K /min
Cooling: 3.0 K /min
Mains connection: 400 V 3/N/PE, AC, 50 Hz
Max. power requirement: 6.3 kW
Weight: 635 kg
Refrigerant: R507 / R23
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
We will be happy to answer any further questions you may have over the phone.
Listing
Borken
785 km
Alternating climate chamber
BinderMKF 720 E1 / E1.1
Call
Condition: used, Binder
Type: MKF 720 E1 / E1.1
Air-cooled
The MKF dynamic climate chamber is a specially developed environmental simulation chamber for
industrial materials testing and environmental simulation. Its unprecedented performance far exceeds the capabilities of a conventional heating chamber. It fulfills all the tasks required for materials testing, as well as aging and stress tests.
TECHNICAL DATA:
Housing dimensions:
Width: 1615 mm Height: 2005 mm Depth: 1230 mm
Internal dimensions: Width: 1200 mm Height: 1020 mm Depth: 600 mm
Main technical features of the MKF 720 E1 / E1.1
Temperature range: -40 °C to +180 °C
Humidity range: 10% RH Up to 98% RH
Interior volume: 734 liters
Weight: approx. 590 kg
Refrigerant: R-404A
Power supply: 400 V 3N~ ±10%, 50 Hz
Rated power: 8.0 kW
Rated current: 12 A
Maximum heat compensation: 6500 W
Humidity control: Steam humidification with capacitive sensor
Controller: Intuitive touchscreen with real-time and time-period programming
Data logger: Integrated, with USB readout function
Bledpswb D Uusfx Aczjr
Safety functions: Visual and audible alarm, Class 2 adjustable temperature limiter (DIN 12880)
Condition: Used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
785 km
Climate test chamber Temp. -70°C to +180°C
Vötsch 190 LiterVCS 7018-5
Call
Condition: excellent (used), Heraeus Vötsch
Type: VCS 7018-5
Climatic Test Chamber with Humidity Control, Water-Cooled
Test Chamber Dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing Dimensions: Width 870 mm x Depth 1280 mm x Height 1775 mm
Characteristics for Temperature Tests:
Temperature Range: -70°C to +180°C
Temperature Range: ± 0.1 to ± 0.5 K
Spatial Range: ± 0.5 to ± 2.0 K
Temperature Gradient: 1 to 4 K
Temperature Rate of Change according to IEC 60068-3-5
Heating: 7.5 K/min
Cooling: 7.5 K/min
Characteristic values for climatic tests:
Temperature range +10 to +95°C
Humidity range: 10 to 98% RH
Temperature deviation over time: ± 0.1 to ± 0.3 K
Temperature deviation over space: ± 0.5 to ± 1 K
Temperature gradient: 1 to 2 K
Blsdpfx Aev N Hc Ejczjr
Humidity fluctuation over time: ± 1 to ± 3% RH F.
Dew point range -3 to +94 °C
Electrical connection:
Nominal voltage: 3/N/PE AC 400V±10% 50Hz
Nominal power: 10 kW
Nominal current: 21 A
Fuse protection: 32 A slow-blow, provided by the customer
Refrigerant: R-404A / R-23
Test chamber volume: approx. 190 liters
Weight: approx. 460 kg
For your safety, please note the following information!
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
785 km
Stress test chamber
Espec (ThermoTec)TPC-212D
Call
Condition: excellent (used), Espec
Type: TPC-212D
Technical Specifications
Test Procedure: HAST – Highly Accelerated Stress Test
Model: Espec TPC-212D
Internal Volume: 2x (approx. 22 liters)
Internal Dimensions (ø x L mm): 2x 295 x 330 mm
Temperature Range: +105 °C to +142.9 °C
Humidity Range: 75% to 100% RH
Pressure Range: 0.02 to 0.196 MPa gauge (0 to 28 psig)
Power Supply: 220 V (±5%), 1-Phase, 50/60 Hz, 20 A
Special Features: Two chambers in one device
Notes:
Two chambers: Allow for simultaneous tests with different parameters or larger test volumes.
HAST test: Accelerated endurance test under high temperature and humidity
with overpressure for the qualification of electronic components.
Applications: Ideal for semiconductors, ICs, circuit boards, MEMS, etc.
Weight: 230 kg
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions over the phone.
Bljdpfxowl D Aae Aczjr
Listing
Borken
785 km
Temperature test chamber
VötschVTS 7034-5
Call
Condition: good (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch temperature test chamber water-cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in terms of time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6.5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
External dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Lateral feed-through 5.5 cm / 12.5 cm
Cabinet is water-cooled
Refrigerant: R- 404A and R 23
Weight approx. 570 kg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
Blsdpfxeun Izce Aczjr
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
785 km
Climate test chamber 335 liters with humidity
VötschVCS 7034-5 -70°C bis +180°C
Call
Condition: good (used), Type: VCS 7034-5
Climatic Test Chamber, Water-cooled
Vötsch VCS 7034-5
Test Volume: 335 liters
Specifications for Temperature Testing:
Temperature range: -70 to +180°C
Time-based temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4 K
Change rate:
Cooling: 6.7 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3000 W / at -20°C: 3000 W
Temperature calibration points: +23°C and +80°C
Specifications for Climate Testing:
Temperature range: +10 to +95°C
Time-based temperature deviation: ±0.1 to ±0.3 K
Bledpfxexmhyco Aczjr
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Time-based humidity deviation: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climate calibration points: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10 kW
Rated current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerants: R452A / R-23
Important safety information for buyers:
The following procedures are carried out on our offered chambers prior to sale:
1. Functional inspection and replacement of necessary components
2. Recharging with legally compliant refrigerant, if required
3. Leak test with certificate
4. After successful testing, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Subject to technical modifications and errors. All information is non-binding!)
For further questions, please do not hesitate to contact us by phone.
Listing
Borken
785 km
Climate test chamber with humidity, 335 liters
VötschVC 7034 -70 bis 180°C
Call
Condition: excellent (used), Vötsch
Type: VC 7018
Vötsch Climatic Test Chamber VC 7018 Water-Cooled
Touch Panel Control Unit
On the touch panel control unit, all control and operating commands can be triggered by simply touching the function symbols.
Adjustable Feet
To compensate for uneven floors and ensure adequate ventilation of the machine section,
the test chamber is equipped with adjustable feet.
Ports
The test chamber is equipped with port holes on the right and left sides.
These allow measurement cables and test equipment to be routed into the test chamber.
Feedthrough included in standard equipment
R1: NW 125 mm
L1: NW 50 mm
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1280 mm x Height 1745 mm
Characteristics for temperature tests:
Temperature range: -70°C to +180°C
Temperature ±0.1 to ±0.5 K
Spatial ±0.5 to ±2.0 K
Bledpfsxugirox Aczer
Temperature change rate according to IEC 60068-3-5
Heating: 4 K/min
Cooling: 2.3 K/min
Characteristics for climatic tests:
Temperature range: -10°C to +95°C
Humidity range: 10% to 98% r.h. F.
Temperature deviation over time in the center of the usable space ± 0.1 to ± 0.3 K
Temperature deviation over space ± 0.5 to ± 1.0 K
Temperature gradient 1 to 2 K
Humidity deviation over time in the center of the usable space ± 1 to ± 3 %RH
Electrical connection:
Nominal voltage: 3/N/PE AC 400V ±10 50Hz
Nominal power: 5.9 kW
Nominal current: 12.0 A
Connection cable: 3.5 m
Fuse protection: 16 A slow-blow, provided by the customer
Refrigerants: R-404A and R-23
Test chamber capacity: approx. 190 liters
Weight: approx. 460 kg net
For your safety, the following information is provided as a buyer!
The following steps are performed on our offered chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
785 km
Climate test chamber 335 liters with humidity
VötschVC 4034 -40°C..+180°C
Call
Condition: good (used), Vötsch
Vötsch Climate Test Chamber, Air Cooled
Converted to refrigerant R-452a
Specifications for Temperature Tests:
Temperature range: -40°C to +180°C
Temporal tolerance: ±0.1 to ±0.5 K
Spatial tolerance: ±0.5 to ±1.5 K
Temperature change rate according to IEC 60068-3-5:
Heating: 3.2 K/min.
Cooling: 3.5 K/min.
Specifications for Climate Tests:
Temperature range: -40°C to +180°C
Temporal tolerance: ±0.1 to ±0.3 K
Spatial tolerance: ±0.5 to ±1.0 K
Humidity range: 10% to 98% r.h.
Test chamber dimensions: Width 580 mm x Depth 765 mm x Height 750 mm
Housing dimensions: Width 780 mm x Depth 1758 mm x Height 1800 mm
Electrical connection:
Rated voltage: 3/N/PE AC 400V +6/-10% 50Hz
Rated power: 4.9 kW
Rated current: 9 A
Refrigerant: R-452a
Test chamber volume: approx. 335 liters
Weight: approx. 515 kg net
Important information for you as a buyer!
The following actions are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, recharge with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Bodexbrkhopfx Aczelr
Condition: used
Scope of delivery: (See photo)
(Specifications subject to change and errors excepted!)
If you have further questions, we will be happy to answer them by phone.
Listing
Germany
785 km
Salt spray chamber Corrosion chamber
KöhlerHKT 500 WTG
Call
Condition: excellent (used), Here we offer you a Köhler salt spray chamber.
Köhler Salt Spray Chamber Corrosion Chamber
Köhler Salt Spray Chamber HKT 500
Operation via touch panel
Inner dimensions W x D x H (without hood) 1880 x 840 x 1210 mm
Test chamber volume 500 l
Temperature range chamber room temp. up to 50°C
Mains supply 230V 1P/N/50Hz 3000W
Type: HKT 500 WTG
400 Kg
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Blodpfxsn Arqds Aczor
Listing
Borken
785 km
Temperature test chamber
VötschVTS³ 7018-5
Call
Condition: excellent (used), Vötsch
Type: VTS³ 7018-5
Water-cooled
Test chamber dimensions: Width 580 mm x depth 450 mm x height 750 mm
Housing dimensions: Width 900 mm x depth 1550 mm x height 1850 mm
Temperature test:
Temperature range: -70°C to +180°C
Temperature change rate: Heating 7.5 K/min
Temperature change rate: cooling 7.5 K/min
Test chamber volume: 190 liters
Nominal voltage: 400V
Rated current: 20 A
Rated power: 9 kW
Weight: approx. 540 kg
Refrigerant: R404A and R23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Blsdsn E Sk Espfx Aczer
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
785 km
Climatic chamber
VötschVC³ 4100
Call
Condition: excellent (used), Vötsch climatic test chamber
Here we offer a Vötsch climatic test chamber.
Designation VC³ 4100 Air-cooled
With temperature change rate of 3 K/min
Test chamber dimensions: Height 950 mm x width 1100 mm x depth 950 mm
Unit dimensions: Height 2000 mm x width 1300 mm x depth 1916 mm
Volume: 990 liters
Feed-through: Ø 125 mm Ø 50 mm
Data for temperature tests:
Temperature range -42°C to +180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature homogeneity in space ± 0.5 to ± 1.5 K
Temperature change rate:
Heating 4.0 K/min
Cooling 3.0 K/min
Max. heat compensation at +20°C 4500 watts
Data for climate tests
Temperature range +10°C to +95°C
Dew point range -3°C to +94°C
Humidity range 10 to 98% r. h.
Temperature deviation temporal ± 0.1 to ± 0.3 K
Temperature homogeneity in space ± 0.5 to ± 1.0 K
Humidity deviation temporal ± 1 to ± 3% r. h.
Heat compensation max. 500 W
Voltage: 3/N/PE AC 400V ± 10% 50Hz
Rated power: 11.5 kW
Nominal current: 22.0 A
Refrigerant: R-404 A
Weight approx. 840 kg
Type: VC³ 4100
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
Blsdpfsqmn A Njx Aczsr
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
785 km
Shock test chamber
HeraeusHT 7012 S2
Call
Condition: excellent (used), Heraeus shock test chamber
Here we offer a shock test chamber.
Temperature shock test chamber water cooled
Two-chamber design
Warm chamber:
The temperature range of the warm chamber is from +50°C to +220°C.
Temperature deviation temporally in useful chamber center ± 1 K
Temperature deviation spatially ± 2 K
Temperature change rate
heating 11 K/min
cold chamber:
the cold chamber from -65°C to +70°C
Temperature deviation temporally in useful space center ± 1 K
temperature deviation spatially ± 2 K
Temperature change rate
heating 2 K/min
cooling 3 K/min
Test chamber volume 125 liters
Temperature range hot chamber +50°C to +220°C
Temperature range cold chamber -80°C to +70°C
Test chamber dimensions width 470mm depth 650mm height 410mm
Outer dimensions width 930mm depth 2115mm height 1970+mm
Rated power 10 kW
Rated current 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerant R404A / R23
Weight: 1000 kg
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
Bsdpfx Aoikvlxjczslr
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Type: HT 7012 S2
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
785 km
Chamber circulating air oven 250°C
EliogKU 250/09-06-06
Call
Condition: excellent (used), Here we offer you a chamber circulating air furnace.
Usable space dimensions : height mm 900 / width mm 600 / depth mm 600
324 liters
Outer dimensions : height mm 1775 / width mm 900 / depth mm 953
Door leaf 1
Connected load: 3X400V 50 Hz 10 kVA
Heating power: 9 kW
Nominal temperature: 250°C
Bedpfx Ajigg Eueczslr
weight: 300 kg
Type: KU 250/09-06-06 K1030852
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
785 km
Environment and Stability Chamber
IVA EngineeringHeißluftprüfkammer M5386
Call
Condition: excellent (used), IVA Engineering
Type: M5386
Environment and stability chamber
Dry Hot Air Test Chamber
Dry hot air test chamber
Rated voltage: 415V AC/20A
Bedjd Nfrljpfx Aczolr
Dimensions:
90.55x78.74x90.55 in - 2204.60 lb
2300x2000x2300 MM - 1000 KGS
Interior Dimensions:
(height x width x depth): approx. 1950 x approx. 1230 x 1510 mm
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
785 km
Climatic chamber
VötschVCS 7033
Call
Condition: excellent (used), Heraeus Vötsch climatic chamber
Here we offer you a Heraeus Vötsch climatic chamber.
Vötsch climatic chamber VCS 7033 water cooled
Temperature range: -70°C to +180°C
Temperature change rate:
Heating 7.5 K/min.
Cooling 6,5 K/min.
Humidity range: 10% to 98% r.H.
Temperature deviation temporal ± 0.5 K
Temperature deviation time-related ± 1.5 K
Test chamber dimensions: Width 675 mm x Depth 650 mm x Height 760 mm
Housing dimensions: Width 930 mm x depth 1565 mm x height 1840 mm
Lateral feedthrough 90mm ∅
approx. 330 L Weight: 600 kg
voltage: 3/N/PE AC 400V ±6/-10% 50Hz
rated power 9,5 kW
Rated current 17 A
Refrigerant R404A / R23
Type: VCS 7033
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
Blodpfxopz H Hxe Aczjr
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
785 km
Temperature test chamber
RS-SimulatorenTS 150/75
Call
Condition: excellent (used), RS simulators
Here we offer a temperature test cabinet.
Temperature test chamber water cooled
Temperature range: -70°C to +180°C
Time deviation: ±1 K according to DIN 50011 with empty test chamber
Bedpfx Aslp Hytoczjlr
Average heating time: approx. 3 K/min 8acc. to DIN 50011 part 12)
Average cooling time: approx. 3 K/min 8acc. to DIN 50011 Part 12)
Test chamber dimensions: Width 530 mm x height 530 mm x depth 530 mm
Outer dimensions: Width approx. 900 mm x Height approx. 1800 mm x Depth approx. 1400 mm
Total power: approx. 6 kVA
power consumption: 12 A
Main fuse: 3 x16 A, slow blow
Connection voltage: 3x400V/N/PE 50Hz
Weight: approx. 600 kg
Type: TS 150/75
Refrigerant: R404A / R23
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
785 km
Climate test chamber Temp. -70 to 180°C
Weiss explosionsgeschütztWK-600/70 (I)-(II) 2 G EEx
Call
Condition: excellent (used), Weiss
Type: WK-600/70 (I)-(II) 2 G EEx /22605147
Weiss climate chamber water-cooled
(test room explosion-proof)
INERTIZATION WITH NITROGEN / EXPLOSION-PROOF TEST ROOM
Technical data:
Test chamber designation: WK-600/70 (I)-(II) 2 G EEx
External dimensions with hinges and door lock
Height 1995 mm, width 1090 mm, depth 1660 mm
External dimensions without hinges and door lock
Height 1995 mm, width 1000 mm, depth 1660 mm
Test room capacity: approx. 600 liters
Cold / heat operation -70 to 180°C
Climate operation 10 – 95°C
Humidity 10...98% r. H.
Temperature change per time
Bledpjv Ewy Hofx Aczsr
Cooling approx. 2.5 K/min
Heating approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 14 kW
Rated current: 25 A
On-site fuse: 32 A slow-blow
Permissible test item weight
Total load of the grate supports 80 kg
Test room floor 80 kg, grate insert 40 kg
Weight: 800 kg
Refrigerant: R 404A/R 23
(The air conditioning system's evaporator has been replaced)
For your safety as a buyer, the following information! The following points are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
We make it easier for you to find: "rotating washing chamber"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Rotating Washing Chamber (10,228)
Search Machineseeker now with more than 200,000 used machines:Browse through the most popular machine descriptions:
- Ball Rotation Apparatus
- Chain Rotator
- Co Rotate Extruder
- Manual Rotary Table
- Nc Rotary Table
- Rotary Die Cutting Machine
- Rotary Oven
- Rotary Table
- Rotary Table Grinding
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month