Used Smoke Chamber for sale (3,583)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
785 km
Climate test chamber 11,000 liters (11 m³)
CTSCW-60/11 -60°C bis +90°C
Call
Condition: excellent (used), CTS CW‑60/11 – Water-Cooled Climatic Test Chamber
The CW‑60/6 from CTS GmbH (Climatic Test Systems) is a medium-sized, walk-in or drive-in climatic chamber designed for temperature and humidity testing of multiple specimens simultaneously.
Device Description
The climatic test chamber allows the function or material properties of a sample to be tested under the influence of temperature and humidity. Efficient air circulation with a correspondingly high recirculation volume ensures effective heat transfer to the test samples. The air handling unit is located at the rear of the interior chamber. The refrigeration units are mounted in a separate frame behind the device, providing easy access. The control system is housed in a separate control cabinet, with the control panel integrated into the cabinet door. For dehumidification of the test chamber, the unit is equipped with a self-regenerating compressed-air dryer. Fresh air flushing of the chamber is possible via a dedicated fan.
Technical Performance Data:
Temperature Tests:
Bedpex Ankyefx Aczedk
Temperature range: –60 °C to +90 °C
Temperature deviation (temporal): ±0.5 to 1 K
Temperature deviation (spatial): ±1 K at 200 mm distance from the wall
Temperature change rate (supply air, linear):
Heating: 2 K/min from –40 °C to +85 °C
Cooling: 2 K/min from +85 °C to –40 °C
Climatic Tests
Temperature range: +10 °C to +95 °C
Humidity range: 10% to 95% RH
Dew point range: +5 °C to +89 °C
Temperature deviation (temporal): ±0.5 K
Humidity deviation: ±2 – ±5% RH (temporal)
No radiant heat
In steady-state condition
Technical data refer to ambient temperature +25 °C, nominal voltage 400 V, without test sample, without radiant heat and without additional equipment.
Dimensions:
Internal dimensions (test space / usable volume):
Volume: approx. 11,000 liters (11 m³)
Internal dimensions (approx.): Height: 2500 mm, Width: 2200-2250 mm, Depth: 2400-2500 mm (may vary slightly depending on configuration)
External dimensions: Height: 2900 mm, Width: 2380 mm, Depth: 2890 mm (depending on door, frame, accessories, etc.)
Operating Data:
Nominal power: 84.4 kW
Nominal voltage: 400 V 3/N 50 Hz
Nominal current: 131.4 A
Technical Specifications:
Refrigeration unit: Water-cooled, low-noise, semi-hermetic, stepless power adjustment via electronic monitoring and control system, environmentally-friendly refrigerants R 23 / R 404 A
Notes
Inspection by appointment only (46325 Borken)
Shipping by freight forwarder possible – Costs & arrangements upon request
Scope of delivery: (see images)
(Specifications and technical data subject to change and error!)
For further questions, we are happy to assist you by phone.
Listing
Tarnock
459 km
Double Chamber Vacuum packing Machine
WebomaticED 120 Double Chamber Vacuum Packer
Call
Condition: excellent (used), machine/vehicle number: 577EK51, REF: MM6187
1 x Webomatic double chamber vacuum packing machine supplied with 16 x filler plates.
Bjdpfx Aexn Rz Esczedk
Technical specification ⚙️
✅ Model - ED 120.
✅ Serial number - 577EK51.
✅ Sealing bars - 4 x 640mm long.
✅ Distance between sealing bars - 580mm.
✅ Vacuum pump - Busch RA 0100 E 5Z1.
✅ Electrical requirements - 400 V / 50 hz / 3 phase.
✅ Power - 2.2 kW / 5.4 Amps.
Listing
Best
726 km
Chamber Belt Vacuum Machines
BMB Vacuum BandCP 10.65
Call
Condition: like new (used), Year of construction: 2020, functionality: fully functional, BMB CP 10.65 industrial vacuum band conveyor, year 2020, in good working condition.
This unit is designed for precise product handling where components need to be held securely on the belt using vacuum suction – commonly used in packaging lines, slicing lines, portioning, thermoforming infeed, and quality-control sections.
Machine is clean, fully functional, and was used in a controlled food-tech production environment.
Technical details:
• Model: CP 10.65
• Year: 2020
• Vacuum suction conveyor with belt perforation
• Stainless steel hygienic construction
• Adjustable vacuum intensity (depending on your plant setup)
Bdodpfx Aex Afcaeczsk
• Suitable for food industry, packaging lines, portioners, and automated systems
• Easy-clean design
• Compact footprint (photograph for exact dimensions)
Condition:
• Fully functional
• Good mechanical condition
• Belt in good shape
• No corrosion or frame damage
• Ready for immediate use
Machine located in Best, Netherlands.

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing
Vincennes
830 km
Used 2-trolley proofing chamber
BongardBFC/800X800
Call
Condition: used, - Dimensions: 2150x1330x2100 mm
- Door dimensions: 1010x1900 mm
- 2 trolleys 600x800 or 800x800
- Serial number: 10130992
- Year of manufacture: 2005
- Voltage: 400 V
Bedpjx Arzcofx Aczedk
- Frequency: 50 Hz
- Operating temperature: 32°C
- Heating capacity: 2.5 kW
- Cooling capacity: 2.99 kW
- Weight: 420 kg
Listing
Borken
777 km
Climate test chamber
EspecPR-3KP
Call
Condition: good (used), operating hours: 75,383 h, Espec PR-3KP Environmental test chamber -20 to +100 °C
Features:
Manufacturer: Espec
Type: PR-3KP
Temperature range: -20 to +100 °C
Humidity: 20 to 98 % rH
Refrigerant R-404A:- CFC-free - ozone-friendly
Bjdswbz Hhjpfx Aczedk
Operating hours: 75383
Dimensions:
External dimensions: HxWxD= 1680 x 1050 x 1200 mm
Chamber dimensions: HxWxD= 850 x 600 x 800 mm
Further items in other sizes - new and used - can be found in our store!
International shipping costs on request!
Discover more used machines
Listing
Borken
785 km
Climate test chamber 11,000 liters (11 m³)
CTSCW-60/11 -60°C bis +90°C
Call
Condition: excellent (used), CTS CW‑60/11 – Water-Cooled Climatic Test Chamber
The CW‑60/6 from CTS GmbH (Climatic Test Systems) is a medium-sized, walk-in or drive-in climatic chamber designed for temperature and humidity testing of multiple specimens simultaneously.
Bodpfx Ajx Anipoczedk
Device Description
The climatic test chamber allows the function or material properties of a sample to be tested under the influence of temperature and humidity. Efficient air circulation with a correspondingly high recirculation volume ensures effective heat transfer to the test samples. The air handling unit is located at the rear of the interior chamber. The refrigeration units are mounted in a separate frame behind the device, providing easy access. The control system is housed in a separate control cabinet, with the control panel integrated into the cabinet door. For dehumidification of the test chamber, the unit is equipped with a self-regenerating compressed-air dryer. Fresh air flushing of the chamber is possible via a dedicated fan.
Technical Performance Data:
Temperature Tests:
Temperature range: –60 °C to +90 °C
Temperature deviation (temporal): ±0.5 to 1 K
Temperature deviation (spatial): ±1 K at 200 mm distance from the wall
Temperature change rate (supply air, linear):
Heating: 2 K/min from –40 °C to +85 °C
Cooling: 2 K/min from +85 °C to –40 °C
Climatic Tests
Temperature range: +10 °C to +95 °C
Humidity range: 10% to 95% RH
Dew point range: +5 °C to +89 °C
Temperature deviation (temporal): ±0.5 K
Humidity deviation: ±2 – ±5% RH (temporal)
No radiant heat
In steady-state condition
Technical data refer to ambient temperature +25 °C, nominal voltage 400 V, without test sample, without radiant heat and without additional equipment.
Dimensions:
Internal dimensions (test space / usable volume):
Volume: approx. 11,000 liters (11 m³)
Internal dimensions (approx.): Height: 2500 mm, Width: 2200-2250 mm, Depth: 2400-2500 mm (may vary slightly depending on configuration)
External dimensions: Height: 2900 mm, Width: 2380 mm, Depth: 2890 mm (depending on door, frame, accessories, etc.)
Operating Data:
Nominal power: 84.4 kW
Nominal voltage: 400 V 3/N 50 Hz
Nominal current: 131.4 A
Technical Specifications:
Refrigeration unit: Water-cooled, low-noise, semi-hermetic, stepless power adjustment via electronic monitoring and control system, environmentally-friendly refrigerants R 23 / R 404 A
Notes
Inspection by appointment only (46325 Borken)
Shipping by freight forwarder possible – Costs & arrangements upon request
Scope of delivery: (see images)
(Specifications and technical data subject to change and error!)
For further questions, we are happy to assist you by phone.
Listing
Borken
785 km
Climate test chamber 600 liters with humidity
WeissWK3-600/0-M -5°C bis +90°C
Call
Condition: excellent (used), Weiss
Model: WK3 600/0-M
Weiss Climate Test Chamber, Water-Cooled
Series: WK3-../0
with SIMPAC* Controller
Test chamber volume: approx. 600 liters
Test chamber dimensions: Height 950 mm, Width 800 mm, Depth 800 mm
External dimensions: Height 1995 mm, Width 1090 mm, Depth 1660 mm
Operating data:
Test chamber lighting: LED 24 V, 6.8 W / Halogen bulb 2 x 24V, 50W
Rated voltage: 1/N / PE AC 230 V ±10% 50 Hz
Rated power: 2.3 kW
Rated current: 10 A
Site-provided fuse: 16 A slow-blow
Control cabinet and operator panel protection class: IP 54
Maximum heat emission to environment: 1200 W
Sound pressure level:
Measured at a distance of 1m from the front, at a height of 1.6m: 46 dB(A)
Bdjdsx Ag R Sspfx Aczsk
Data for temperature tests:
Temperature range: -5°C to +90°C
Temporal temperature deviation at center of usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1 K
Temperature gradient (according to IEC 60068-3-5)
Temperature change rate:
Heating 0.6 K/min
Cooling 0.3 K/min
Heat compensation at +20°C to +50°C: 200 W
Data for climatic tests:
Temperature range: +10°C to +90°C
Dew point range: 4 to +89.5°C
Humidity range: 10 to 98 % r.h.
Temporal temperature deviation at center of usable space: ± 0.1 to ± 0.3 K
Spatial temperature deviation: ± 0.5 to ± 1 K
Temporal humidity deviation: +1 to +3 % r.h.
Refrigerant: R-404A
Weight: 610 kg
For your safety as a buyer, please note the following information!
The following points are carried out in advance on our offered chambers:
1. Functionality check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used
Scope of delivery: (See image)
(Technical data and information subject to change and errors!)
We are happy to answer any further questions you may have by phone.
Listing
Borken
785 km
Spray/jet water test chamber
Weiss TechnikSWT 1000 – IPX9K
Call
Condition: excellent (used), Weiss
Type: SWT 1000 – IPX9K
Weiss Spray and Splash Water Test Chamber
Description:
Offered for sale is a WaterEvent SWT 1000 test chamber from Weiss Technik – ideal for standardized testing of enclosure or component water ingress protection (IP) classes.
With optional features, testing according to IPX9K (high-pressure/steam jet), ISO 20653, and additional standards is possible.
High-pressure/steam jet nozzles for IPX9K
Jet nozzles for IPX5/6, among others, compliant with standards:
ISO 20653, DIN EN 60529, SAE J 575, JIS D 0203,
MIL-STD 810, EN 60068-2-18, IEC 60598-1.
Possible Protection Classes & Tests
Depending on configuration, the SWT system covers a wide range of tests:
Standard configuration: IPX3 / IPX4 tests (spraying and splashing water from all directions).
Optionally: Higher protection classes up to IPX5 / IPX6 (jetting water), and – with corresponding high-pressure configuration – up to IPX9 and IPX9K.
Tests are based on standards such as DIN EN 60529 (for IP protection levels) and ISO 20653 (e.g. for vehicle or outdoor applications) – depending on intended use.
Bsdpfxjxzprco Aczedk
Typical Applications
Typical application scenarios for such a test chamber include:
• Electronic devices or enclosures intended for outdoor use or humid environments, such as outdoor lighting, control housing, assemblies, panels.
• Components for vehicles or machines, especially those exposed to rain, splashing water, or high-pressure cleaning (e.g., construction machinery, e-bike or vehicle parts).
• Batteries or electrical components requiring water ingress protection testing – e.g., automotive industry or e-mobility applications.
Technical Data:
Applicable protection classes: IPX3 / IPX4
Oscillating tube radius (for IPX3/4 tests): standard 200 mm (for SWT 1000), optionally up to 400 mm.
Test chamber (interior):
Internal dimensions: approx. 1,000 × 1,015 × 1,000 mm (W × H × D)
Operation / Control: Web panel or GUI for test programming and control.
Condition: used
Scope of supply: (see photo)
(Data subject to change and correction. Technical specifications may be updated without notice.)
Further questions welcomed by phone.
Listing
Borken
785 km
Temperature test chamber 480 liters
VötschVTS 7048-10 -70°C bis +180°C
Call
Condition: good (used), Vötsch
Model: VTS 7048-1
Heraeus Vötsch Temperature Test Chamber, Water-Cooled
Performance Data:
With a temperature change rate of 10 K/min
Test chamber internal dimensions: height 950 mm, width 800 mm, depth 650 mm
External dimensions: height 2025 mm, width 1000 mm, depth 2480 mm
Temperature range: -70°C to +180°C
Temporal temperature deviation: ±0.3 to ±0.8
Spatial temperature uniformity: ±0.5 to ±2
Temperature change rate (cooling): 10 K/min
Temperature change rate (heating): 10 K/min
Heat compensation at -20°C: 8,000 W
Heat compensation at +20°C: 8,000 W
Test volume: 480 liters
Left: 1x side port, ∅ 125 mm
Left: 1x side port, ∅ 50 mm
Right: 1x side port, ∅ 125 mm
Chamber is water-cooled
Test chamber illumination:
Halogen bulb: 24 V, 50 W
Electrical connection:
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 17 kW
Rated current: 30 A
Refrigerant: R-404A / R-23
Weight: approx. 1,250 kg
Bdodpfx Asxzgn Ioczjk
Important information for your safety as a buyer!
The following steps are carried out in advance on our offered chambers:
1. Function check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see image)
(Specifications are subject to change and errors excepted!)
For further questions, feel free to contact us by phone.
Listing
Borken
785 km
Temperature test chamber 600 liters 5 K/min
VötschVTS 7060-5 -70°C bis + 180°C
Call
Condition: excellent (used), Vötsch
Type: VTS 7060-5
Halogen Bulb 24V, 50W
Vötsch temperature test chamber with color touch panel and S!MPAT
Temperature range: -70°C to +180°C, water-cooled
Temperature deviation over time: ±0.1 to ±0.5 K
Temperature deviation spatially: ±0.5 to ±2.0 K
Temperature change rate cooling: 6 K/min
Temperature change rate heating: 6 K/min
Test chamber dimensions:
Width: 800 mm, Depth: 800 mm, Height: 950 mm
External dimensions:
Width: 1000 mm, Depth: 1750 mm, Height: 2005 mm
Viewing window:
Width: 300 mm x Height: 540 mm
Test chamber volume: 600 liters
Sound level at 1m distance (free-field measurement): < 69 dB(A)
Left side port: 50 mm diameter
Right side port: 2 x 125 mm diameter
Rated voltage: 3/N/PE AC, 400 V ±10%, 50 Hz
Rated power: 16 kW, Rated current: 30 A
Circuit breaker, customer-provided: 29 A slow-blow
Chamber is water-cooled
Refrigerants: R-404A and R 23
Weight approx. 675 kg
For your safety as the buyer, please note the following information!
The following points are completed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legal, compliant refrigerants
3. After successful inspection, the chambers are subjected to a test run monitored with calibrated instruments.
Bdedpfoxw Uqpjx Aczsk
Condition: used
Scope of delivery: (see picture)
(Technical data subject to change and errors excepted!)
We would be happy to answer any further questions by phone.
Listing
Borken
785 km
Shock test chamber –80 °C to +220 °C
VötschVT 7012 S2
Call
Condition: excellent (used), Vötsch
Model: VT 7012 S2
Shock Test Chamber, Air-cooled
Bjdpfx Acewxc I Ujzjdk
Two-chamber design
Hot Chamber:
The temperature range of the hot chamber extends from +50°C to +220°C
Temporal temperature deviation at the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate
Heating: 11 K/min
Cold Chamber:
The cold chamber temperature range is from -80°C to +70°C
Temporal temperature deviation at the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate
Heating: 2 K/min
Cooling: 3 K/min
Test chamber volume: 125 liters
Hot chamber temperature range: +50°C to +220°C
Cold chamber temperature range: -80°C to +70°C
Test chamber dimensions: Width 470 mm, Depth 650 mm, Height 410 mm
External dimensions: Width 930 mm, Depth 2115 mm, Height 1970+ mm
Port diameter: ∅ 67 mm
Voltage: 3/N/PE AC 400V +10% 50 Hz
Nominal power: 10 kW
Nominal current: 25 A
Refrigerants: R452-A / R23
Weight: 1,000 kg
Important information for your safety as a buyer!
The following points are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Specifications and technical details are subject to change and correction!)
For further questions, please feel free to contact us by phone.
Listing
Borken
785 km
Climatic chamber with humidity, 335 liters
VötschVC³ 7034 -70°C bis +180°C
Call
Condition: excellent (used), Type: VC³ 7034
Heraeus Vötsch Climate Test Chamber with Humidity Control (Air-Cooled)
Test Chamber Dimensions: Width 580 mm x Depth 765 mm x Height 750 mm
External Dimensions: Width 780 mm x Depth 1,758 mm x Height 1,800 mm
Specifications for Temperature Testing:
Temperature range: -70°C to +180°C
Temporal deviation: ± 0.1 to ± 0.5 K
Spatial deviation: ± 0.5 to ± 1.5 K
Temperature change rate according to IEC 60068-3-5
Heating: 3.0 K/min
Cooling: 3.0 K/min
Specifications for Climate Testing:
Temperature range: -70°C to +180°C
Temperature deviation in steady-state condition, according to IEC 60068-3-5
(depending on chamber temperature)
Temporal deviation: ± 0.1 to ± 0.3 K
Spatial deviation: ± 0.5 to ± 1 K
Humidity range: 10% to 98% RH
Electrical Connection:
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 4.9 kW
Rated current: 16 A
Protection: 16 A slow-blow fuse, provided by customer
Refrigerant: R-404A/R23
Test chamber volume: approx. 335 liters
Net weight: approx. 515 kg
For your safety as a buyer, please note the following information:
The following actions are performed on all chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. If required, refill with legally compliant refrigerant
3. Leak test with certificate
4. Upon successful inspection, chambers undergo a documented test run.
Condition: Used
Scope of delivery: (see picture)
(Subject to modifications and errors in technical data and specifications!)
Bjdpfxjxfh Spe Aczodk
For further inquiries, please feel free to contact us by phone.
Listing
Borken
785 km
Temperature test chamber
Heraeus VötschHT 7010 -70°C bis +180°C
Call
Condition: excellent (used), Type: HT 7010
Heraeus Vötsch temperature test cabinet, water-cooled
Temperature deviation in time ± 1 K
Temperature deviation in space ± 2 K
Housing dimensions: Width 820 mm Depth 840 mm Height 1670 mm
Interior: Width 550 mm Depth 350 mm Height 550 mm
Rated voltage: 230V +6/-10% 1/N 50Hz
Rated power: 3.2 kW Rated current: 14.5 A
Temperature range -70°C to + 180°C
2 x side feedthrough 9cm
Weight approx. 260 kg
Refrigerant: R404A and R23
For your safety as a buyer, the following information! The following points are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
Bdedjhhyz Sspfx Aczjk
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
785 km
Temperature shock test chamber
WEISSTS 130
Call
Condition: excellent (used), White temperature shock test chamber
Here we offer a temperature shock test chamber.
Weiss temperature shock test chamber air cooled
( Compressor was renewed ! )
Specification:
Temperature range hot chamber +60°C ... +220°C
Bdodpfjk E Htyjx Aczsk
Temperature range cold chamber -10°C ... -80°C
Change hot-/cold chamber 10 s
Temperature constancy ±1 K
Dimensions and further data:
External dimensions: Height 1990 mm
Width ( without and with swivel arm ) without....ca. 1820 mm with....ca. 1915 mm
Depth ( without and with test chamber door ) without....approx. 900 mm with....approx. 1155 mm
Dimensions of the lifting basket ( test chamber ) height 450 mm, width 500 mm, depth 600 mm
volume 130 liters
Test space load max. 20 kg
Test chamber floor load max. 20 kg
Cooling water pressure min. 2 ... max. 6 bar
Max. Backup fuse 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of unit approx. 65 dB(A)
Cooling cascade water cooled
Connected load: 3/N/PE/AC 400V ±10% 50Hz /14,0 kW
nominal current 26,0 A
Refrigerant R 404A / R23
Weight: approx. 950 kg
Type: TS 130
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
785 km
Temperature chamber with vibration table
EspecQualmark T2.5 + Kompressor 99480630
Call
Condition: like new (used), HALT/ HASS Espec
Bdjdpfxoqwybge Aczok
Here we offer you a temperature chamber.
Temperature -100 to + 200°C
Table in lower position (WxDxH) 889 x 889 x 889 mm
Table in upper position (WxDxH) 889 x 889 x 635 mm
Overall dimensions (WxDxH) 1425 x 1748 x 2134 mm
Work table 762 x 762 mm
Max load 145 kg
Acceleration 5 to 75 gRMS
Voltage
480 or 440 V / 60 A / 3F
400 or 380 V / 80 A / 3F
Type: Qualmark T2.5 + compressor 99480630
Condition: used Only 147 hours
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
More We will be happy to answer any questions you may have over the phone.
Listing
Borken
785 km
Walk-in climate chamber with humidity
RS-SimulatorenKKM 40/45S
Call
Condition: excellent (used), Here we offer you a walk-in climate chamber.
Manufacturer: RS Simulators, water-cooled
The chamber can be dismantled into 3 parts for transport (bolted)
Temperature range: -30°C to +100°C
Bdodpoqw U Aajfx Aczok
Refrigerant: 20kg R-404A + 20kg R-452A
External dimensions: approx. width 3920 mm, depth 7350 mm, height 2600 mm
Test room dimensions: approx. width 3500 mm, depth 5400 mm, height 2110 mm
Electrical data: 68kW nominal power
Voltage: 3x400V/PE; Current: 135A
Type: KKM 40 / 45 S
Further technical data will follow!
For your security as a buyer, the following information!
The following points are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data and information are reserved!)
We are happy to answer further questions by phone for you.
Listing
Borken
785 km
Climatic chamber
Heraeus VötschVC³ 0100
Call
Condition: excellent (used), Heraeus Vötsch climatic test chamber
Here we offer Heraeus Vötsch climatic test chamber.
Designation VC³ 0100
Test chamber dimensions: H x W x D, approx. 950 x 1100 x 950 mm
TEMPERATURE TESTS:
Minimum temperature -0°C
Maximum temperature +90°C
Temperature change rate cooling 0.2 K/min
Temperature change rate heating 0.5 K/min
Temperature deviation in time ± 0.1 to ± 0.5 K
Temperature homogeneity in space ± 0.5 to ± 1.0 K
Heat compensation at +20 °C 350W
CLIMATIC TESTS:
Minimum temperature +10°C
Maximum temperature +90°C
Dew point temperature range +4°C to +89.5°C
Humidity range 10 to 98% r. h.
Humidity deviation over time ± 1 to ± 3% r. h.
Temperature deviation temporal ± 0.1 to ± 0.3K
Temperature homogeneity in space ± 0.5 to ± 1.0K
Voltage: 1/N/PE AC 230V±10% 50Hz
Rated power: 2.6 kW
Nominal current: 12 A
Bedpfx Acsn Ard Sjzjdk
Refrigerant: R 404A
Weight approx. 1400 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Type: VC³ 0100 / year of construction 2013
Condition: second-hand / used
Scope of delivery: (see picture)
(Subject to changes and errors in the technical data and specifications!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
785 km
Temperature test chamber 335 liters
Vötsch-70°C bis +180°C VTS 7034-5
Call
Condition: excellent (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch temperature test chamber water-cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in terms of time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6.5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
External dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50 Hz
Rated power: 10 kW Rated current: 21 A
Bjdpfx Acsu H U Twozodk
Sound level at 1m distance (free-field measurement) < 69dB (A)
Lateral feed-through 5.5 cm / 12.5 cm
Cabinet is water-cooled
Refrigerant: R- 404A and R 23
Weight approx. 570 kg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have over the phone.
Listing
Borken
785 km
Climatic test chamber 335 liters with humidity
VötschVCS 7034-5 -70°C bis +180°C
Call
Condition: good (used), Vötsch
Type: VCS 7034-5
Water-cooled climatic test chamber
Vötsch VCS 7034-5
Test chamber capacity 335 liters
Performance for temperature tests
Temperature range -70 to +180°C
Temperature deviation temporal K ±0.1 to ±0.5
Spatial temperature deviation K ±0.5 to ±2.0
Temperature gradient 1 to 4
Rate of change :
Cooling 6.7 K/min
Heating 6.8 K/min
Heat compensation at +20 °C 3000 W / at -20°C 3000 W
Temperature calibration values +23 °C and +80 °C
Performance for climate tests
Bjdpfxjuudx De Aczedk
Temperature range +10 to +95°C
Temperature deviation in time ±0.1 to ±0.3 K
Spatial temperature deviation ±0.5 to ±1.0 K
Temperature gradient 1 to 2 K
Humidity range 10 to 98%
Humidity deviation in time ±1 to ±3%
Dew point range -3 to +94°C
Heat compensation 400W
Climate calibration values +23 °C / 50 % r.h. and +95 °C / 50 % r.h.
Test chamber dimensions: Width 580mm Depth 765mm Height 750mm
External dimensions: Width 870mm Depth 1595mm Height 1775mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10kW
Rated current: 21 A
Sound pressure level: 64dB(A)
Cooling water consumption: 1.4m³/h
Refrigerant: R-404A / R-23
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
785 km
Temperature chamber 986 liters
ThermotronSE-1000-6-6 -70°C bis + 180°C
Call
Condition: excellent (used), Here we offer you Thermotron temperature chamber.
Water cooled
Thermotron temperature chamber SE-1000-6-6
Inner dimensions: WxDxH 1000 x 1000 x 980 mm
Working volume: approx. 980 liters
Temperature range: -70ºC to 180ºC
Heating up total : ca 4,1 K
Cooling down total : ca 1,2 K
Bdedpjixtitofx Aczek
Heating power in ºC/minute -65º to 71ºC: 6.8ºC
Heating power in ºC/minute -65º to 180ºC: 5.6ºC
Heating capacity in ºC/minute -40º to 85ºC: 6.5ºC
Cooling capacity in ºC/minute 85º to -40ºC: 4.7ºC
Cooling capacity in ºC/minute 71º to -65ºC: 3.7ºC
Cooling capacity in ºC/minute 180º to -65ºC: 4.3ºC
External dimensions - WxDxH: 1250 x 1900 x 2200 mm
Electrical requirements 400V/5P/N/PE 35 A
Refrigerants: R508B and R404 A
Approx. weight: 900 kg
Type: Thermotron SE- 1000-6-6
For you as a buyer, the following information for your safety!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
785 km
Climate chamber
VötschVC³ 4060
Call
Condition: excellent (used), Heraeus Vötsch climatic test chamber
Here we offer a Heraeus Vötsch climatic test chamber.
Heraeus Vötsch climatic test chamber with humidity (water cooled)
Test chamber dimensions: Width 800 mm x depth 800 mm x height 950 mm
Housing dimensions: Width 1090 mm x depth 1960 mm x height 1995 mm
Characteristic values for temperature tests:
Temperature range: -45°C to +180°C
temporal ± 0.1 to ± 0.5 K
spatially ± 0.5 to ± 1.5 K
Temperature change rate according to IEC 60068-3-5
heating: 4.0 K/min
cooling: 3.0 K/min
Bdedpfx Acomt Du Tszjk
Characteristic values for climatic tests:
Temperature range: -45°C to +180°C
Temperature deviation in steady state, according to IEC 60068-3-5
depending on test room temperature
Temperature range: - 10°C to +95°C
temporal ± 0.1 to ± 0.3 K
spatially ± 0.5 to ± 1.0 K
Humidity range: 10 % to 98 % r. h.
Humidity deviation temporal +1 to ±3
Electrical connection:
Rated voltage: 3/N/PE AC 400V±10% 50Hz
Rated power: 7,8 kW
Rated current: 15,0 A
Refrigerant R452A
Test chamber capacity: approx. 600 liters
Weight: approx. 620 kg net
Type: VC³ 4060
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.Condition: gebraucht / usedScope of delivery: (See picture)
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
785 km
Temperature test chamber 350 liters
CTSTS-70/350 -70°C bis 180°C
Call
Condition: excellent (used), Here we offer you a temperature test cabinet.
Water cooled
Technical performance data:
Temperature working range
Temperature range in °C -70 / +180°C
Rate of change according to DIN 50 011, part 12
Cooling rate: approx. 5 K/min
Heating rate: approx. 5 K/min
Dimensions:
Test volume: 350 liters
Test chamber dimensions height, approx. 750 mm, width, approx. 650 mm, depth, approx. 720 mm
External dimensions height, approx. 1800 mm, width, approx. 850 mm, depth, approx. 1640 mm
Operating data:
Electrical connection 400 V, 3/N, 50 Hz.
nominal power 13,3 kW
Refrigerant: R404A / R23
Bjdpfxsn Sl T So Aczodk
Weight: approx. 650 Kg
Type: TS-70/350
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
785 km
Stress test chamber
EspecEHS-221MD
Call
Condition: excellent (used), Espec
Here we offer an Espec (ThermoTec) stress test chamber.
Bdsdpfx Ajpdm Uyeczjk
Outer dimensions: W x H x D: 860 x 1795 x 1000 mm
Test chamber dimensions W x H x D: 355 x 355 x 426 mm
2 x 46 l
Voltage 230 V 1/N 50 Hz
Rated current 37A
Fuses 250 V , 2 x 3 A
Type: EHS-221MD
Temperature range: + 105°C to + 142.9°C
Humidity range 75 to 100 % r.H.
Temperature constancy: -+ 0.5 °C
Pressure range: 0 to 2.0 kg/cm²
Heat-up or pressure build-up time: from 0 to 2.0 kg/cm² in about 60 minutes
390 kg
Condition: Used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
785 km
Temperature test chamber
RS-SimulatorenTS 600/45 EX
Call
Condition: excellent (used), RS Simulators
Here we offer a test cabinet.
Water cooled
Temperature range: -40°C to +180°C
Test chamber dimensions: 850mm x 850mm x 800mm (WxHxD)
Outer dimensions: 1100mm x 1850mm x 1500mm (WxHxD)
Bsdpeg Urq Ijfx Aczsdk
current consumption: 13,5 A
Refrigerant: R404A
Connection voltage: 3x400V/N/PE 9A
Weight: approx. 750kg
Type: TS 600/45
Explosion proof operation not tested
but Max 160°C in this
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in technical data, specifications are reserved!)
Further questions we can answer gladly on the phone for you.
Listing
Borken
785 km
Salt spray chamber
WeissSC/KWT 450
Call
Condition: good (used), White
Type: SC/KWT 450
Salt spray chamber
Technical data:
Test chamber capacity 450 liters
Max. load 100 kg
Brine storage tank 180 liters
External dimensions: Height 920 mm Width 1930 mm Depth 800 mm
Test compartment dimensions: Height 740 mm Width 850 mm Depth 570 mm
Areas of application:
Corrosion tests:
Salt spray test: room temp. up to + 50°C
Condensation water test: Room temp. up to + 45°C
Humidifier +75°C
Temperature constancy
The temperature deviation over time is ± K.
Voltage: 1/N/PE AC 230V ±10% 50Hz
Rated power 2.0 kW Rated current 8.5 A
Combination:
Salt spray test SS: DIN 50021
Condensation water test KFW: DIN 50017
Bsdpfsudvg Rjx Aczodk
Normal climate (ventilation): DIN 50014
Weight: 180 kg
Condition: second-hand / used
Scope of delivery: (see picture)
(We reserve the right to make changes and errors in the technical data and specifications)
We will be happy to answer any further questions you may have on the phone.
We make it easier for you to find: "smoke chamber"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Smoke Chamber (3,583)
Search Machineseeker now with more than 200,000 used machines:Browse through the most popular machine descriptions:
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
















































































































































































































