Used Curing Chamber for sale (4,220)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Tarnock
459 km
Double Chamber Vacuum packing Machine
WebomaticED 120 Double Chamber Vacuum Packer
Call
Condition: excellent (used), machine/vehicle number: 577EK51, REF: MM6187
1 x Webomatic double chamber vacuum packing machine supplied with 16 x filler plates.
Itjdoxn Rz Eepfx Ah Uer
Technical specification ⚙️
✅ Model - ED 120.
✅ Serial number - 577EK51.
✅ Sealing bars - 4 x 640mm long.
✅ Distance between sealing bars - 580mm.
✅ Vacuum pump - Busch RA 0100 E 5Z1.
✅ Electrical requirements - 400 V / 50 hz / 3 phase.
✅ Power - 2.2 kW / 5.4 Amps.
Listing
Borken
777 km
Temperature shock test chamber -70-220°C
VötschVT 7012 S2
Call
Year of construction: 2000, operating hours: 104,382 h, condition: excellent (used), Vötsch Shock Test Chamber VT 7012 S2
System for extreme temperature cycling
Temperature shock testing is used to test the resistance of components, devices, and other products to rapid changes in ambient temperature.
The test specimens are subjected to rapid temperature changes in air with alternating upper and lower temperature loads.
These cyclical stresses and the accelerated aging caused by temperature changes reveal weaknesses in the test specimen.
Vertical arrangement of the test chambers
Ball screw drive for safe guidance of the car
Cart load capacity 50 kg for VT3 7012 S2
All-around grilles in the car secure the test specimens
High air circulation rate, short temperature change times, and uniform temperature distribution in the test chamber
Hot chamber can be used as a temperature storage unit, cold chamber as a temperature exchange unit
Minimal energy consumption
No compressed air required
Manufacturer: Vötsch
Type: VT 7012 S2
Type: Temperature shock test chamber
Test chamber volume: 120 l
Nominal voltage: 400 V
Nominal power: 10 kW
Nominal current: 25 A
Refrigerant: R452A
Cooling unit: Water-cooled
Shock cooling (nitrogen cooling) via customer-supplied nitrogen
External dimensions
Width: 930 mm
Depth: 2115 mm
Height: 1970 mm
Test chamber dimensions
Width: 470 mm
Depth: 650 mm
Height: 410 mm
Protection class
Device: IP 42
Operating panel: IP 20
Control cabinet: IP 54
Temperature test parameters for single-chamber operation |
Test chamber dimensions
Width: 470 mm
Depth: 650 mm
Height: 410 mm
Protection class ...Temperatur Temperature range
Hot chamber: +50°C to +220°C
Cold chamber: -70°C to +70°C
Temperature deviation over time: ±2 K
in steady state
Temperature deviation over space: ±2 K
in steady state in the car
Iedpfx Ahox Exmtj Ustr
Heating rate, hot chamber: 11 K/min
Cooling rate, cold chamber: K/min
Heating rate, cold chamber: 2 K/min
Cooling rate, hot chamber: K/min
Observation window: 355 x 355 mm
Pipe opening: 67 mm
Year of manufacture: 2000
Operating hours: 104,382
Weight: 1000 kg
Further items – new and used – can be found in our shop! International shipping costs on request!
Listing
Borken
785 km
Spray/jet water test chamber
Weiss TechnikSWT 1000 – IPX9K
Call
Condition: excellent (used), Weiss
Type: SWT 1000 – IPX9K
Weiss Spray and Splash Water Test Chamber
Description:
Offered for sale is a WaterEvent SWT 1000 test chamber from Weiss Technik – ideal for standardized testing of enclosure or component water ingress protection (IP) classes.
With optional features, testing according to IPX9K (high-pressure/steam jet), ISO 20653, and additional standards is possible.
High-pressure/steam jet nozzles for IPX9K
Jet nozzles for IPX5/6, among others, compliant with standards:
ISO 20653, DIN EN 60529, SAE J 575, JIS D 0203,
MIL-STD 810, EN 60068-2-18, IEC 60598-1.
Possible Protection Classes & Tests
Iodpfsxzprcsx Ah Ujtr
Depending on configuration, the SWT system covers a wide range of tests:
Standard configuration: IPX3 / IPX4 tests (spraying and splashing water from all directions).
Optionally: Higher protection classes up to IPX5 / IPX6 (jetting water), and – with corresponding high-pressure configuration – up to IPX9 and IPX9K.
Tests are based on standards such as DIN EN 60529 (for IP protection levels) and ISO 20653 (e.g. for vehicle or outdoor applications) – depending on intended use.
Typical Applications
Typical application scenarios for such a test chamber include:
• Electronic devices or enclosures intended for outdoor use or humid environments, such as outdoor lighting, control housing, assemblies, panels.
• Components for vehicles or machines, especially those exposed to rain, splashing water, or high-pressure cleaning (e.g., construction machinery, e-bike or vehicle parts).
• Batteries or electrical components requiring water ingress protection testing – e.g., automotive industry or e-mobility applications.
Technical Data:
Applicable protection classes: IPX3 / IPX4
Oscillating tube radius (for IPX3/4 tests): standard 200 mm (for SWT 1000), optionally up to 400 mm.
Test chamber (interior):
Internal dimensions: approx. 1,000 × 1,015 × 1,000 mm (W × H × D)
Operation / Control: Web panel or GUI for test programming and control.
Condition: used
Scope of supply: (see photo)
(Data subject to change and correction. Technical specifications may be updated without notice.)
Further questions welcomed by phone.

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing
Dortmund
837 km
El. heated chamber furnace
NaberthermN 250/85 A
Call
Condition: ready for operation (used), type: N 250/85 A
temperature: 850°C
Itjdpfox Eiu Sex Ah Uer
connected load: 29,0 A
current consumption: 0 kW
voltage: 400 V 3/N
Light dimensions (W x D x H): approx. 650 x 750 x 650 mm
Listing
Vincennes
830 km
BFC 600×800 proofing chamber
BongardBFC 600×800
Call
Condition: used, - Tray dimensions/format: 600 × 800 mm trays (compatible with 600×800 trolley pairs)
- Trolley capacity: 2 x (600 x 800)
- Model: BFC 600×800 (tray reference: 4CE12CH 4PC) – Serial No.: 15604095
- Year of manufacture: 2010
- Power supply: 400 V three-phase – 50 Hz – 6 A
Iodpex D Azisfx Ah Uotr
- Connected electrical power: 2.20 kW
- Integrated heating: 2 kW (for consistent and stable proofing)
- Cooling: 2.32 kW – R404A refrigerant (charge: 2.2 kg) for cold management/proofing delay
- Ambient operating temperature: 32 °C
- Manufacturer: BONGARD – renowned quality and reliability in the bakery sector
- Condition: used (see photos and technical label)
Discover more used machines
Listing
Villingen-Schwenningen
1,158 km
Complete UV Light Curing System
DELODELOLUX pilot A4T
Call
Condition: ready for operation (used), machine/vehicle number: 95 202 74, This listing includes a fully operational, complete DELO DELOLUX UV curing system, consisting of:
DELOLUX pilot A4T control & power supply unit
2× DELOLUX 20/400 A2 LED area lamps (400 nm)
Mounting brackets, integrated cooling, and all original high-quality cabling
DELO is one of the world’s leading manufacturers of industrial UV curing systems used in electronics, optics, medical device assembly, precision bonding, and automated production lines.
This system provides extremely high-intensity, uniform UV illumination over a large area, perfect for high-speed adhesive curing and automated processes requiring absolute stability and repeatability.
Included Components
1) DELOLUX pilot A4T Control & Power Unit
Model: A4T
Input Voltage: 100–240 V AC, 50/60 Hz
Power Consumption: 1.45 kW
Fuse: T16 A / 250 V
User Interface: Large touchscreen display (Login, Admin/User profiles)
Control Ports: PLC 1–4 (digital control inputs)
Function: Central control, monitoring, and power delivery for LED heads
2) Two LED Heads – DELOLUX 20/400 A2
Wavelength: 400 nm
Cooling: Air-cooled
Illumination Area: 112 × 112 mm
Perfect uniformity for industrial curing processes
Both heads include mounting brackets + 280 cm cable each
Technical Specifications
UV LED Heads (each):
Model: DELOLUX 20/400 A2
Wavelength: 400 nm
Cooling: Air-cooled
Illumination area: 112 mm × 112 mm
Serial Numbers: included on the labels
Cable length: 280 cm
Control Unit (A4T):
Model: DELOLUX pilot A4T
Input: 100–240 V AC
Power: 1.45 kW
Fuse: T16A
Port outputs: Up to 4 LED heads
Itsdpox Emqgofx Ah Uor
Power cable length: 180 cm
Condition
Fully working, tested with both LED heads
Bright output, even intensity
Cosmetically excellent
No damage to connectors, filters, or LED arrays
Perfect for:
Industrial adhesive curing, electronics production, display manufacturing, PCB assembly, medical device fabrication, optical bonding, and automated UV curing stations.
Cable Lengths (included):
Power cable (A4T): 180 cm
LED head cables: 280 cm each
Thank you for considering our surplus machining and electrical items for purchase. These items have been in our company's stock for several years, but they are in functional condition. Due to the length of time they've been in storage, some of the items may show signs of aging or wear on the packaging, but the contents are in excellent condition.
We want to be transparent about the condition of these items, so please note that the packaging may be slightly damaged, discolored, or have markings from storage. However, this does not affect the functionality of the items inside. We have inspected all of the items and can confirm that they are in functional condition.
We will take great care in packaging and shipping your order to ensure that it arrives in the same condition as it was when it left our facility. If you have any questions about these items, please don't hesitate to contact us. Thank you for your interest!
Listing
Best
726 km
Chamber Belt Vacuum Machines
BMB Vacuum BandCP 10.65
Call
Condition: like new (used), Year of construction: 2020, functionality: fully functional, BMB CP 10.65 industrial vacuum band conveyor, year 2020, in good working condition.
This unit is designed for precise product handling where components need to be held securely on the belt using vacuum suction – commonly used in packaging lines, slicing lines, portioning, thermoforming infeed, and quality-control sections.
Machine is clean, fully functional, and was used in a controlled food-tech production environment.
Technical details:
• Model: CP 10.65
• Year: 2020
• Vacuum suction conveyor with belt perforation
• Stainless steel hygienic construction
• Adjustable vacuum intensity (depending on your plant setup)
• Suitable for food industry, packaging lines, portioners, and automated systems
• Easy-clean design
• Compact footprint (photograph for exact dimensions)
Condition:
• Fully functional
• Good mechanical condition
• Belt in good shape
• No corrosion or frame damage
• Ready for immediate use
Iodox Afcaepfx Ah Ustr
Machine located in Best, Netherlands.
Listing
Borken
777 km
Temperature test chamber Climate test
VötschVTR 7033/S
Call
Year of construction: 1997, condition: good (used), Vötsch VTR 7033/S Temperature Test Chamber
Manufacturer: Vötsch
Type: VTR 7033/S
Item No.: 60885637
Temperature Chamber
Temp. Range: -70°C to +180°C
Line Voltage: 400V
Rated Current: 24A
Itsdpfxjuuiv Io Ah Uor
Rated Power: 9.5 kW
Refrigerant (VK): R 404 A
Refrigerant (TK): R 23
Year of Manufacture: 1997
TK 08
Find more items - new and used - in our shop!
International shipping costs upon request!
Listing
Borken
785 km
Temperature test chamber 480 liters
VötschVTS 7048-10 -70°C bis +180°C
Call
Condition: good (used), Vötsch
Model: VTS 7048-1
Heraeus Vötsch Temperature Test Chamber, Water-Cooled
Performance Data:
With a temperature change rate of 10 K/min
Test chamber internal dimensions: height 950 mm, width 800 mm, depth 650 mm
External dimensions: height 2025 mm, width 1000 mm, depth 2480 mm
Temperature range: -70°C to +180°C
Temporal temperature deviation: ±0.3 to ±0.8
Spatial temperature uniformity: ±0.5 to ±2
Temperature change rate (cooling): 10 K/min
Temperature change rate (heating): 10 K/min
Heat compensation at -20°C: 8,000 W
Heat compensation at +20°C: 8,000 W
Test volume: 480 liters
Left: 1x side port, ∅ 125 mm
Left: 1x side port, ∅ 50 mm
Right: 1x side port, ∅ 125 mm
Chamber is water-cooled
Test chamber illumination:
Halogen bulb: 24 V, 50 W
Electrical connection:
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 17 kW
Rated current: 30 A
Itodpexzgn Isfx Ah Uor
Refrigerant: R-404A / R-23
Weight: approx. 1,250 kg
Important information for your safety as a buyer!
The following steps are carried out in advance on our offered chambers:
1. Function check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see image)
(Specifications are subject to change and errors excepted!)
For further questions, feel free to contact us by phone.
Listing
Borken
777 km
Walk-in climate test chamber
VötschVSKZ 04/120/S
Call
Year of construction: 1996, condition: excellent (used), Vötsch VSKZ 04/120/S Walk-In Climatic Test Chamber
Iodsuuigyepfx Ah Uetr
Manufacturer: Vötsch
Type: VSKZ 04/120/S
Temp. Range: -40°C to +120°C
Line Voltage: 400V
Rated Current: 95A
Rated Power: 56 kW
Refrigerant: R 404 A
Year of Manufacture: 1996
External Dimensions: W 2850 x D 4100 x H 3080 mm
SO-01
Find more items - new and used - in our shop!
International shipping costs on request!
Listing
Borken
785 km
Temperature test chamber 600 liters 5 K/min
VötschVTS 7060-5 -70°C bis + 180°C
Call
Condition: excellent (used), Vötsch
Type: VTS 7060-5
Halogen Bulb 24V, 50W
Vötsch temperature test chamber with color touch panel and S!MPAT
Temperature range: -70°C to +180°C, water-cooled
Temperature deviation over time: ±0.1 to ±0.5 K
Temperature deviation spatially: ±0.5 to ±2.0 K
Temperature change rate cooling: 6 K/min
Temperature change rate heating: 6 K/min
Itjdpfxsxw Uqpe Ah Ujr
Test chamber dimensions:
Width: 800 mm, Depth: 800 mm, Height: 950 mm
External dimensions:
Width: 1000 mm, Depth: 1750 mm, Height: 2005 mm
Viewing window:
Width: 300 mm x Height: 540 mm
Test chamber volume: 600 liters
Sound level at 1m distance (free-field measurement): < 69 dB(A)
Left side port: 50 mm diameter
Right side port: 2 x 125 mm diameter
Rated voltage: 3/N/PE AC, 400 V ±10%, 50 Hz
Rated power: 16 kW, Rated current: 30 A
Circuit breaker, customer-provided: 29 A slow-blow
Chamber is water-cooled
Refrigerants: R-404A and R 23
Weight approx. 675 kg
For your safety as the buyer, please note the following information!
The following points are completed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legal, compliant refrigerants
3. After successful inspection, the chambers are subjected to a test run monitored with calibrated instruments.
Condition: used
Scope of delivery: (see picture)
(Technical data subject to change and errors excepted!)
We would be happy to answer any further questions by phone.
Listing
Borken
777 km
Climate test chamber Temperature test
VötschVC 0150
Call
Condition: excellent (used), Vötsch VC 0150 Climatic Test Chamber 0°C - +90°C
Manufacturer: Vötsch
Type: VC 0150
Climatic Test Chamber
Voltage: 230 V
Rated Power: 1.5 kW
Voltage: 1540 liters
Temperature Range: 0°C to +90°C
Humidity: 10% to 98%
Refrigerant: R 134a
Dimensions: W 950 x D 1100 x H 1475 mm
Microprocessor Controller
Itodpfeuuikfex Ah Usr
List Price: €19,500
KK-09
Find more items - new and used - in our shop!
International shipping costs upon request!
Listing
Borken
785 km
Climate chamber -75°C / +180°C with humidity
TIRATCC 7120
Call
Condition: excellent (used), TIRA
Type: TCC 7120
Temperature range: -75°C / +180°C
Air-cooled condenser
Temperature stability (over time and in the center of the usable space) ±0.1°C ... ±0.3 °C
Maximum temperature change rate
Itjdowfddwepfx Ah Uer
Heating: 4°C/min
Cooling: 3°C/min
Humidity range: 10% to 98% relative humidity
Humidity stability over time ±1% ÷ ±3%
Dew point range for long-term tests +2 / +94 °C
Dew point range for short-term tests -20 / +2 °C
External dimensions (L x D x H) 1320 x 2235 x 2137 mm
Test space dimensions (L x D x H) 1000 x 1130 x 1020 mm
Test chamber volume: approx. 1152 liters
Max. load per grid: 50 kg
Maximum floor load of the test chamber: 100 kg
Refrigerants: R404A and R23
Power supply: 400V + 6%/-10% / 50Hz / 3P+N+PE
Rated power: 10.2 max. 17.5 kW
Rated current: 19.5 max. 32.0 A
Noise level: approx. 80 dB(A)
Weight: 1180 kg
For your safety, the following information is provided as a buyer!
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leakage test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
777 km
Climate test chamber Temperature test
VötschVCS 4100
Call
Condition: good (used), Vötsch VCS 4100 Climatic Test Chamber -40°C to +180°C
Manufacturer: Vötsch
Type: VCS 4100
Temp. Range: -40°C to +180°C
Line Voltage: 400 V
Rated Current: 17 A
Rated Power: 11 kW
Refrigerant: R404A
KK-07
Find more items - new and used - in our shop!
Iodouuiygspfx Ah Uotr
International shipping costs upon request!
Listing
Borken
785 km
Temperature test chamber 600 liters
CTST-40/600 -40...180°C
Call
Condition: excellent (used), CTS
Itsdpfswfdniox Ah Uer
Type: T-40/600 /011232
CTS Temperature Test Chamber, Water-Cooled
Includes metal struts to increase the floor load-bearing capacity
Test chamber volume: 600 liters
Test chamber dimensions:
Height approx. 850 mm, width approx. 850 mm, depth approx. 830 mm
External dimensions:
Height approx. 1900 mm, width approx. 1050 mm, depth approx. 1850 mm
Temperature operating range:
Temperature range -40 to +180°C
Temperature deviation ±0.1 to ±0.3 K over time
Heating rate: 2.5 K/min
Cooling rate: 3 K/min
Electrical connection: 400 V +6% -10%, 3/N, 50 Hz
Rated power: approx. 5.5 kW
Rated current: approx. 8.5 A
Refrigerant: R-404A
Weight: 550 kg
For your safety, please note the following information!
The following steps are performed on our chambers in advance:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
785 km
Climatic chamber with humidity, 335 liters
VötschVC³ 7034 -70°C bis +180°C
Call
Condition: excellent (used), Type: VC³ 7034
Heraeus Vötsch Climate Test Chamber with Humidity Control (Air-Cooled)
Test Chamber Dimensions: Width 580 mm x Depth 765 mm x Height 750 mm
External Dimensions: Width 780 mm x Depth 1,758 mm x Height 1,800 mm
Specifications for Temperature Testing:
Temperature range: -70°C to +180°C
Temporal deviation: ± 0.1 to ± 0.5 K
Spatial deviation: ± 0.5 to ± 1.5 K
Temperature change rate according to IEC 60068-3-5
Heating: 3.0 K/min
Cooling: 3.0 K/min
Specifications for Climate Testing:
Temperature range: -70°C to +180°C
Temperature deviation in steady-state condition, according to IEC 60068-3-5
(depending on chamber temperature)
Temporal deviation: ± 0.1 to ± 0.3 K
Spatial deviation: ± 0.5 to ± 1 K
Humidity range: 10% to 98% RH
Electrical Connection:
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 4.9 kW
Rated current: 16 A
Protection: 16 A slow-blow fuse, provided by customer
Refrigerant: R-404A/R23
Test chamber volume: approx. 335 liters
Net weight: approx. 515 kg
For your safety as a buyer, please note the following information:
The following actions are performed on all chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. If required, refill with legally compliant refrigerant
3. Leak test with certificate
4. Upon successful inspection, chambers undergo a documented test run.
Condition: Used
Scope of delivery: (see picture)
(Subject to modifications and errors in technical data and specifications!)
Ijdpfx Asxfh Speh Uotr
For further inquiries, please feel free to contact us by phone.
Listing
Borken
785 km
Salt spray chamber / climate cycling device
WeissSC/KWT 450
Call
Condition: excellent (used), Weiss
Itodpfx Ahsw Hz Trj Usr
Type: SC/KWT 450
Salt Spray Chamber
Technical Data:
Test chamber volume: 450 liters
Maximum load: 100 kg
Brine reservoir: 180 liters
External dimensions: Height 920 mm, Width 1930 mm, Depth 800 mm
Test chamber dimensions: Height 740 mm, Width 850 mm, Depth 570 mm
Applications:
Corrosion tests:
Salt spray test: Ambient temperature up to +50°C
Condensation water test: Ambient temperature up to +45°C
Humidifier +75°C
Temperature stability
The temporal temperature deviation is ± K.
Voltage: 1/N/PE AC 230V ±10% 50Hz
Rated power: 2.0 kW Rated current: 8.5 A
Combination:
Salt spray test SS: DIN 50021
Condensation water test KFW: DIN 50017
Standard climate (ventilation): DIN 50014
Weight: 180 kg
Condition: used
Scope of delivery: (See picture)
(Subject to technical modifications and errors! All provided data are subject to change!)
For further questions, please feel free to contact us by phone.
Listing
Borken
785 km
Temperature shock test chamber
WEISSTS 130
Call
Condition: excellent (used), White temperature shock test chamber
Here we offer a temperature shock test chamber.
Weiss temperature shock test chamber air cooled
( Compressor was renewed ! )
Specification:
Temperature range hot chamber +60°C ... +220°C
Temperature range cold chamber -10°C ... -80°C
Change hot-/cold chamber 10 s
Temperature constancy ±1 K
Dimensions and further data:
External dimensions: Height 1990 mm
Width ( without and with swivel arm ) without....ca. 1820 mm with....ca. 1915 mm
Depth ( without and with test chamber door ) without....approx. 900 mm with....approx. 1155 mm
Dimensions of the lifting basket ( test chamber ) height 450 mm, width 500 mm, depth 600 mm
Isdpfx Ajk E Htyjh Uetr
volume 130 liters
Test space load max. 20 kg
Test chamber floor load max. 20 kg
Cooling water pressure min. 2 ... max. 6 bar
Max. Backup fuse 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of unit approx. 65 dB(A)
Cooling cascade water cooled
Connected load: 3/N/PE/AC 400V ±10% 50Hz /14,0 kW
nominal current 26,0 A
Refrigerant R 404A / R23
Weight: approx. 950 kg
Type: TS 130
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
785 km
Temperature chamber with vibration table
EspecQualmark T2.5 + Kompressor 99480630
Call
Condition: like new (used), HALT/ HASS Espec
Here we offer you a temperature chamber.
Temperature -100 to + 200°C
Table in lower position (WxDxH) 889 x 889 x 889 mm
Table in upper position (WxDxH) 889 x 889 x 635 mm
Overall dimensions (WxDxH) 1425 x 1748 x 2134 mm
Work table 762 x 762 mm
Max load 145 kg
Acceleration 5 to 75 gRMS
Voltage
480 or 440 V / 60 A / 3F
400 or 380 V / 80 A / 3F
Type: Qualmark T2.5 + compressor 99480630
Condition: used Only 147 hours
Scope of delivery: (See picture)
Itjdpfoqwybgjx Ah Uer
(Changes and errors in the technical data, information is subject to change!)
More We will be happy to answer any questions you may have over the phone.
Listing
Borken
785 km
Walk-in climate chamber with humidity
RS-SimulatorenKKM 40/45S
Call
Condition: excellent (used), Here we offer you a walk-in climate chamber.
Manufacturer: RS Simulators, water-cooled
The chamber can be dismantled into 3 parts for transport (bolted)
Temperature range: -30°C to +100°C
Refrigerant: 20kg R-404A + 20kg R-452A
External dimensions: approx. width 3920 mm, depth 7350 mm, height 2600 mm
Test room dimensions: approx. width 3500 mm, depth 5400 mm, height 2110 mm
Electrical data: 68kW nominal power
Voltage: 3x400V/PE; Current: 135A
Type: KKM 40 / 45 S
Further technical data will follow!
For your security as a buyer, the following information!
The following points are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data and information are reserved!)
Itjdpfoqw U Aaox Ah Uer
We are happy to answer further questions by phone for you.
Listing
Borken
785 km
Climate chamber with humidity 34 liters
WeissWKL 34/60 -60°C bis 150°C
Call
Condition: excellent (used), White
Type: WKL 34/60
Weiss air-cooled climate chamber
Refrigerant converted to R-452A
-60°C to 150°C
Room volume: 34 liters
Entry port installed in basic equipment:
R1 NW 50 mm
L1NW 120 mm
Internal dimensions: Height 310 mm Width 324 mm Depth 300 mmm
External dimensions: Height 1740 mm Width 630 mm Depth 970 mmm
Characteristic values for temperature tests:
Temperature range -60 to +150 °C
Temperature differences in steady state, according to IEC 60068-3-5)
Temperature fluctuation over time in the center of the usable space ± 0.3 to ± 1 K ± 1 to ± 2 K
Temperature deviation in space (corresponds to temperature gradient) 2 to 4
Temperature change rate (according to IEC 60068-3-5)
Heating 2.5 K/min
Cooling 3 K/min
Heat compensation max. 550 W
Characteristic values for climate tests:
Temperature range +10 to +95 °C
Humidity range 10 to 98 %r.H.
Temperature and humidity differences (in steady state, according to IEC 60068-3-5)
Temperature fluctuation over time in the center of the usable space ± 0.3 to ± 0.5 K
Temperature deviation in space ± 0.5 to ± 1.5
(corresponds to temperature gradient) 1 to 3
Humidity fluctuation over time in the center of the usable space ± 3 to ± 5 %RH
Data for operation:
Test room lighting Halogen bulb 12V, 20W
Nominal voltage 1/N / PE AC 230 V ± 10 % 50 Hz
Rated power 2.5 kW
Rated current 11 A
On-site fuse 16A slow-blow
Iodpfx Aotr Dineh Uotr
Heat dissipation air-cooled test chambers
Max. Heat dissipation to surroundings 1700 W
Refrigerant: R-452A / R23
Weight: 140 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
785 km
Dust test chamber dust chamber
Testzentrum Baden Primus EngineeringDST 1000
Call
Condition: excellent (used), Type: DST 1000
Description:
For sale is a dust test chamber, type DST1000, from Testzentrum Baden GmbH.
This unit was developed for conducting IP protection class “dust” tests (DIN EN 60529 / DIN 40050 Part 9).
Testing possible with or without vacuum.
Operation / Features:
- Control panel with display and buttons
- Manual regulators for individual settings
- Preset test routines for standardized testing
Technical Data:
- Test chamber volume: approx. 1,000 liters
- Internal dimensions (W × D × H): approx. 1,000 × 1,000 × 1,000 mm
- Overall dimensions (W × D × H): approx. 1,300 × 1,000 × 2,000 mm
- Supply voltage: 400 V / 50 Hz, 3~N/PE
- Current consumption: 10 A
- Total electric power: max. 2 kW
- Exhaust connection: DN100 flange
Test Performance / Protection Classes:
- Dust-protected IP5X
Isdpjxpfx Ujfx Ah Uetr
- Dust-tight IP6X
Weight: approx. 350 kg
Condition: used
Scope of delivery: (See image)
(Specifications are subject to change and errors excepted!)
We are happy to answer further questions by phone.
Listing
Borken
785 km
Climate test chamber with humidity
WeissWK3-340/70 -70°C bis +180°C
Call
Condition: excellent (used), Type: WK3-340/70
Weiss Climate Test Chamber, Water-Cooled
Control Unit: “Touch Panel”
All control and operating commands can be triggered simply by touching the function symbols on the “Touch Panel” control unit.
Adjustable Feet
The test chamber is equipped with adjustable feet to compensate for uneven floors and to ensure sufficient ventilation of the machine section.
Feed-Throughs
The test chamber is fitted with feed-throughs on both the left and right sides. These allow measuring cables and test devices to be routed into the test chamber. Feed-throughs included in the basic configuration:
R1: nominal width 125 mm
L1: nominal width 85 mm
Volume: 335 liters
Test Chamber Internal Dimensions:
Height: 750 mm, Width: 580 mm, Depth: 765 mm
External Dimensions:
Height: 1775 mm, Width: 870 mm, Depth: 1600 mm
Specifications for Temperature Tests:
Minimum temperature: –72°C
Maximum temperature: +180°C
Temperature deviation over time: ± 0.1 to ± 0.5 K
Temperature uniformity spatially: ± 0.5 to ± 1.5 K
Temperature change rate, cooling: 3 K/min
Temperature change rate, heating: 3 K/min
Specifications for Climate Tests:
Temperature range: +10°C to +95°C
Dew point range: –3°C to +94°C
Humidity range: 10 to 98% RH
Temperature deviation over time: ± 0.1 to ± 0.3 K
Temperature uniformity spatially: ± 0.5 to ± 1 K
Humidity deviation over time: ± 1 to ± 3% RH
Operating Data:
Test chamber lighting: Halogen bulb 2 x 24V, 50W
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal current: 16 A
Nominal power: 4.9 kW
Protection: 16 A slow-blow fuse, to be provided onsite
Refrigerant: R-452A/R23
Isdpfxjxmg Sdj Ah Uotr
Weight: approx. 585 kg
For your security as a buyer, please note the following information!
The following procedures are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Technical data, information and specifications are subject to change and errors.)
If you have any further questions, we will be happy to assist you by phone.
Listing
Borken
785 km
Salt spray chamber corrosion test cabinet
VLMSAL 1000-FL PLC / V.715.362.520
Call
Condition: excellent (used), Type: SAL 1000-FL PLC / V.715.362.520
For sale is a used VLM Salt Spray Corrosion Test Chamber, type SAL 1000-FL PLC, ideal for industrial corrosion tests in accordance with international standards (DIN EN ISO 9227, ASTM B117). Perfectly suited for both laboratory and production environments to test materials, coatings, and components under controlled corrosive conditions.
Features:
- Robust stainless steel frame construction, max. load 450 kg
- Precise control and reproducible testing
- Versatile applications for salt spray, condensation water, and ventilation testing
Technical details:
- Exterior: Stainless steel 1.4301, powder-coated (special version)
- Test chamber: Stainless steel, ECTFE-coated
- Max. chamber temperature: +80 °C
- Temperature stability: ±0.3 °K, temporally ±0.1 °C
- Process control: PLC with touchscreen, LED display
- Interface: Ethernet
- Water quality: demineralized, max. conductivity 20 µS/cm
- Humidifier water consumption: approx. 0.5 l/h (depending on program)
- Water connection pressure: 2–4 bar
- Compressed air consumption: approx. 20 m³/h
- Compressed air connection: 6–8 bar
Itjdpfx Aexnyqvsh Uer
- External dimensions (W x D x H): 2160 x 670 x 1090 mm
incl. base cabinet: 2160 x 670 x 1890 mm
- Internal chamber dimensions (W x D x H) / volume: 1400 x 605 x 920 mm / 1040 l
- Max. load sample rod: 40 kg
- Electrical connection: 400 V / 50 Hz / 4000 W
- Weight (empty): 350 kg
Condition: used
Scope of delivery: (see image)
(Subject to changes and errors in technical data and specifications!)
For further questions, we are happy to assist you by phone.
Listing
Borken
785 km
Temperature test chamber 335 liters
VötschVT 4034 -40°C..+180°C
Call
Condition: excellent (used), Vötsch
Type: VT 4034
Vötsch Temperature Cabinet VT 4034 Air-Cooled
Refrigerant: Converted to R-452 A
Internal dimensions: Height 750 mm, Depth 765 mm, Width 580 mm
External dimensions: Height 1780 mm, Depth 1595 mm, Width 865 mm
Temperature range: -40°C to +180°C
Temperature deviation:
temporal ± 0.1 to ± 0.5 K
spatial ± 0.5 to ± 2.0 K
Heating 3.2 K/min
Cooling 3.5 K/min
Maximum load (evenly distributed across the surface)
of the test chamber floor: 60 kg
per insert: 30 kg
Total load of the grate supports: 80 kg
Test chamber lighting: 24 V halogen bulb 50W
Rated voltage: 3/N/PE AC 400V ± 10% 50 Hz
Rated power: 4.1 kW
Rated current: 12.5 A
Fuse provided by the customer: 16 A slow-blow
Refrigerant: R-452A
Weight: 490 kg / 335 liters
For your safety, the following information!
The following steps are carried out on our chambers in advance:
1. Functional test and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
Itsdewd Hpajpfx Ah Ujr
We are happy to answer any further questions you may have over the phone.
We make it easier for you to find: "curing chamber"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Curing Chamber (4,220)
Search Machineseeker now with more than 200,000 used machines:Browse through the most popular machine descriptions:
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month


























































































































































































































