Description
Vötsch Climate Test Chamber
We offer a Vötsch climate test chamber.
Model: VC³ 4100, air-cooled
With a temperature change rate of 3 K/min
Test chamber internal dimensions: Height 950 mm x Width 1100 mm x Depth 950 mm
External dimensions: Height 2000 mm x Width 1300 mm x Depth 1916 mm
Chamber volume: 990 liters
Feed-throughs: Ø 125 mm, Ø 50 mm
Specifications for temperature tests:
- Temperature range: -42°C to +180°C
- Temporal temperature deviation: ±0.1 to ±0.5 K
- Spatial temperature uniformity: ±0.5 to ±1.5 K
- Temperature change rates:
- Heating: 4.0 K/min
- Cooling: 3.0 K/min
- Maximum heat compensation at +20°C: 4500 W
Specifications for climate tests:
- Temperature range: +10°C to +95°C
- Dew point range: -3°C to +94°C
- Humidity range: 10 to 98% r.H.
Bcedpfx Abjyguw Nspeu
- Temporal temperature deviation: ±0.1 to ±0.3 K
- Spatial temperature uniformity: ±0.5 to ±1.0 K
- Temporal humidity deviation: ±1 to ±3% r.H.
- Max. heat compensation: 500 W
Power supply: 3/N/PE AC 400V ±10% 50Hz
Nominal power: 11.5 kW
Nominal current: 22.0 A
Refrigerant: R-404A
Weight: approx. 840 kg
Type: VC³ 4100
Important buyer information:
The following procedures are carried out on all our chambers prior to sale:
1. Functional checks and replacement of necessary components
2. If required, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run
Condition: used
Scope of delivery: (See picture)
(Technical data subject to change and errors excepted!)
For further questions, please feel free to contact us by phone.
The listing was translated automatically. Translation errors are possible.
We offer a Vötsch climate test chamber.
Model: VC³ 4100, air-cooled
With a temperature change rate of 3 K/min
Test chamber internal dimensions: Height 950 mm x Width 1100 mm x Depth 950 mm
External dimensions: Height 2000 mm x Width 1300 mm x Depth 1916 mm
Chamber volume: 990 liters
Feed-throughs: Ø 125 mm, Ø 50 mm
Specifications for temperature tests:
- Temperature range: -42°C to +180°C
- Temporal temperature deviation: ±0.1 to ±0.5 K
- Spatial temperature uniformity: ±0.5 to ±1.5 K
- Temperature change rates:
- Heating: 4.0 K/min
- Cooling: 3.0 K/min
- Maximum heat compensation at +20°C: 4500 W
Specifications for climate tests:
- Temperature range: +10°C to +95°C
- Dew point range: -3°C to +94°C
- Humidity range: 10 to 98% r.H.
Bcedpfx Abjyguw Nspeu
- Temporal temperature deviation: ±0.1 to ±0.3 K
- Spatial temperature uniformity: ±0.5 to ±1.0 K
- Temporal humidity deviation: ±1 to ±3% r.H.
- Max. heat compensation: 500 W
Power supply: 3/N/PE AC 400V ±10% 50Hz
Nominal power: 11.5 kW
Nominal current: 22.0 A
Refrigerant: R-404A
Weight: approx. 840 kg
Type: VC³ 4100
Important buyer information:
The following procedures are carried out on all our chambers prior to sale:
1. Functional checks and replacement of necessary components
2. If required, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run
Condition: used
Scope of delivery: (See picture)
(Technical data subject to change and errors excepted!)
For further questions, please feel free to contact us by phone.
The listing was translated automatically. Translation errors are possible.
Seller
Note: Register for free or log in, to access all information.
Registered since: 2012
Send inquiry
Telephone & Fax
+49 2861 ... show
These listings may also fit your interest.
Listing
Borken
785 km
Climate test chamber with humidity
VötschVC³ 4100 990 Liter -42°C bis +180°C
VötschVC³ 4100 990 Liter -42°C bis +180°C
Listing
Borken
785 km
Climatic chamber
VötschVC³ 4100
VötschVC³ 4100
Your listing has been deleted successfully
An error has occurred