Used Material testing for sale (493)
Sort results
- Lowest price Highest price
- Latest listings Oldest listings
- Shortest distance Farthest distance
- Latest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Latest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Latest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation A to Z
- Designation
- designation Z to A
- Designation
- Model A to Z
- Model
- Model Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest running time
- Runtime
- Relevance
- Relevance
Measuring & testing equipment Material testing
Listing

785 km
Chamber convection oven
EliogKU 300/09-06-06/2
Call
Condition: excellent (used), Eliog
Here we offer you a chamber air circulation furnace.
Usable space dimensions : height mm 900 / width mm 600 / depth mm 600
324 liters
Outer dimensions : height mm 1775 / width mm 900 / depth mm 953
Door leaf 1
Connected load: 3X400V 50 Hz 13 kVA
Heating power: 12 kW
Nominal temperature: 300°C
weight: 400 kg
Type: KU 300/09-06/2 K1051071
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Dcsbeifkiis Hdrdqog
Further questions we can answer on the phone for you.
Listing

785 km
Temperature test chamber ex protected
CTS-30°C bis +80°C T-30/950 Ex/I
Call
Year of construction: 2011, Condition: excellent (used), Here we offer you CTS temperature test chamber.
Control-32 bit controller
Deb Heihb Amodrdqjcg
LCD control panel
Digital display of set and actual values
Numerical input of the setpoints
Error messages in plain text
Interface RS 232
Free switching channels for on-site test material control
Temperature tests:
temperature range -30°C to +80°C
temperature deviation ±0,3 K temporally
Temperature change rate
heating 2 K/min
Cooling 1.5 K/min to -10°C
Heat radiation approx. 1000 W at +20°C
approx. 200 W at -25°C
Data for gas supply:
Temperature range: -25°C to +55°C
Temperature deviation: ±0.25 K to the test space
Temperature change rate measured on average at a gas flow of 10 Nm³/h: at least as fast as the test chamber
Data for the gas return:
Temperature range: +18°C to +30°C
Temperature deviation: ±0.25 K to the test chamber
Nitrogen inerting with residual oxygen monitoring
With nitrogen inerting, the test chamber is first purged with the large purge volume N2 until the
oxygen content is less than 3%. After that, the system switches to a base load (approx. 10% of the large flush volume).
is switched over.
The nitrogen flow rate of the base load is measured with a flow meter, displayed and monitored by a limit switch.
and monitored by means of a limit switch.
The O2 monitoring system continuously extracts from the test chamber via a flashback arrestor
gas from the test chamber via a flame arrester and passes it over an O2 sensor that monitors the residual oxygen content of the extracted air.
The gas is then returned to the test chamber via a second flashback arrestor.
test chamber. The exhaust pump is monitored by a volumetric flow meter. Further details can be found
can be found in the Dräger operating instructions in the appendix.
The gas device is currently out of service!
The technical data refer to an ambient temperature of +25 °C,
Nominal voltage 400V , without test material, without irradiation and without additional equipment.
Dimensions:
Test volume 950 liters
Test chamber dimensions height approx. 700 mm / width approx. 900 mm depth approx. 1500 mm
External dimensions height approx. 2400 mm / width approx. 1270 mm depth approx. 3125 mm
Operating data:
Electrical connection 400V+6/-10 %, 3/N,50 Hz
rated power 21,6 kW
rated current: 36,5 A
Protection class IP 54
condensate drain pressureless R 1/2" female thread
Sound pressure level < 62 dB(A)
(according to DIN EN ISO 3744
measured at 1m distance from front)
weight: approx. 1500 kg, control cabinet approx. 300 kg
external refrigeration unit
refrigerant R404A / R23
Type: T-30/950 Ex/I
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

785 km
Vibration test system
RMSSW 1507 / TGA 1500
Call
Condition: excellent (used), RMS vibration exciter with power amplifier and cooling fan
Here we offer you a RMS vibration exciter with power amplifier.
Vibration exciter SW 1507
Max force 2158 N
max. speed 1,3 ms
Power amplifier TGA 1500
3 x 380V/ 50Hz/ 35A / 8 kVA
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in technical data, specifications are reserved!)
Dcob Hdrjgkaibjdqeg
Further questions we can answer on the phone for you.
Written order possible by email or fax

Find out now
+44 20 806 810 84
+44 20 806 810 84
Create listing
*per listing / month
Listing

785 km
Climatic chamber
Vötsch VC³ 4100
Call
Condition: excellent (used), Vötsch climatic test chamber
Here we offer a Vötsch climate test chamber.
Designation VC³ 4100 Air-cooled
With temperature change rate of 3 K/min
Test chamber dimensions: Height 950 mm x width 1100 mm x depth 950 mm
Device dimensions: Height 2000 mm x width 1300 mm x depth 1916 mm
Volume: 990 liters
Feed-through: Ø 125 mm Ø 50 mm
Data for temperature tests:
Temperature range -42°C to +180°C
Temperature deviation in time ± 0.1 to ± 0.5 K
Temperature homogeneity in space ± 0.5 to ± 1.5 K
Djb Hdrjqnutmjdqocg
Rate of temperature change:
Heating 4.0 K/min
Cooling 3.0 K/min
max. heat compensation at +20°C 4500 Watt
Data for climate tests
Temperature range +10°C to +95°C
Dew point range -3°C to +94°C
Humidity range 10 to 98% r. h.
Temperature deviation temporal ± 0.1 to ± 0.3 K
Spatial temperature homogeneity ± 0.5 to ± 1.0 K
Humidity deviation temporal ± 1 to ± 3% r. h.
Heat compensation max. 500 W
Voltage: 3/N/PE AC 400V ± 10% 50Hz
Rated power: 11.5 kW
Rated current: 22.0 A
Refrigerant: R-404 A
Weight approx. 840 kg
Type: VC³ 4100
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after a successful check, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Climatic test chamber -40 to +180°C
WeissWK-480/40/10 480 Liter m. Feuchte
Call
Condition: excellent (used), Here we offer a Weiss climatic test chamber.
Dcjb Hdeq Dpzyordqog
Water-cooled
Test chamber lighting Halogen bulb 24V, 50W
Data for temperature tests:
Temperature range: -40°C to +180°C
Temporal temperature deviation in the center of the chamber: ± 0.3 to ± 0.8 K
Spatial temperature deviation: ± 0.5 to ± 2 K
Temperature change rate
Heating: 10 K/min
Cooling: 12.5 K/min
Heat compensation at +20°C 8000 W
Heat compensation at -20°C 3000 W
Data for climate tests
Temperature range: +10°C to +95°C
Humidity range: 10 to 98 % r.h.
Temperature deviation in time in the center of the usable space: ± 0.2 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1 K
Humidity fluctuation over time in the center of the usable space: ± 1 to ± 3 % RH
Test chamber dimensions: Height 950 mm, width 760 mm, depth 650 mm,
External dimensions: Height 2025 mm, width 1090 mm, depth 2480 mm,
Nominal voltage: 3/N/PE AC 400 V ± 10% 50 Hz
Rated current: 24 A Rated power: 16.0 KW
Refrigerant: R452A
Weight: approx. 900 kg
Type: WK-480/40/10
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Laboratory furnace
DespatchLCC1-16NV-3
Call
Condition: excellent (used), Here we offer a Despatch lab oven.
Despatch Laboratory Ovens
+ 8 "WAFER
LCC: Maximum temperature 260 ° C
Lockable circuit breakers turn on the control panel for easy maintenance
Protocol 3 control with large LCD display, built-in data logging capabilities and USB port for easy oven setup and data export
Edelstellenne room with interior seams welded continuously on the insulation side to protect the working space from pollution
Programmable door locking prevents the operator from opening the oven door while the cycle is running
The door lock switch turns off the heating when the door is open
The rolled air flow consists of 100% HEPA (High Efficiency Particulate Air) and is filtered to ISO Class 5 (Class 100) throughout the process cycle
The Magnehelic Manometer monitors the pressure drop of the HEPA filter so you know when to replace the filter
Electric door unlocking for ergonomic operation
UL & C-UL Listed Control Panel Open
Modbus communication connection (RS485) for remote monitoring and recording
Chamber measure L 350 mm
Chamber measure B 350 mm
Chamber Measure H 350 mm
Djb Hod Nfq Isdrdqjcg
Maximum temperature 260°C
Digital screen Yes
Electric connection 230 V
Total size L 830 mm
Total dimensions B 910 mm
Total Measure H 560 mm
Type: LCC1-16NV-3
Condition: used/used
Delivery: (See picture)
(Changes and errors in technical D
Listing

785 km
C02 incubator CO2 incubator
JouanIG 150
Call
Condition: good (used), Here we offer a Jouan C02 incubator CO2 incubator.
The CO2 incubator is used to grow cell cultures.
The following conditions are required for this:
a sterile atmosphere
a constant temperature
a CO2-enriched atmosphere
high humidity
Dimensions and weight:
Temperature range: room temperature + 5 ° C to 50 ° C
CO2 detector: Infrared
Size: 90 x 73 x 60cm
Internal dimensions: 66 x 48 x 45 cm
Outer material: steel
Interior material: Stainless steel
Inner door: Safety glass
CO2 Incubator Jouan IG 150
Water jacket volume 85 liters maximum
Volume 154 liters
Maximum number of trays (3 supplied)
Usable area per tray 0.16 m2
Usable maximum incubation area: 1.28 m2
minimum spacing height 66 mm
empty weight approx. 80 kg
Weight when filled with water approx. 170 kg
Weight with packaging approx. 100 kg
Power connection required: 230 V, 50 or 60 Hz.
Power consumption max. 800 VA, normal consumption at 37 °C: 220 watts
Fuses therm. Magnetic switch, set to 5 A at 220 V Phases earthed.
Color of connections brown = phase, blue = neutral, yellow/green = earth
Working range:
Ambient temperature 15 - 30°C
CO2 inlet pressure 300 mbar - 3 bar
Interior temperature range from 5°C above room temperature to 45°C
Working range with CO2 gas 0.0 % to 20.0 0/0
Article weight: 80.00 kg
Type IG 150
Scope of delivery: (see picture)
2 weeks commissioning guarantee
The device comes from stock.
We deliver with express shipping (DHL, UPS, TNT)
Dceb Hdsccb N Uordqjg
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Test chamber for parametric test
S & A55°C bis +150°C 4220A
Call
Condition: good (used), Here we offer you an S & A test chamber for parametric testing.
S & A test chamber for parametric testing
Temperature range: 55°C to +150°C
Stability:
± 0.1 ° C including the effects of mains voltage, ambient temperature and ageing.
temperature and ageing
Cooling medium: Water-cooled mechanical cooling
Chamber can be controlled remotely via IEEE bus or
RS232C interface
Weight approx. 250 kg
Type: 4220A
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Dcob Hdecnic Sordqog
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Salt spray test chamber Climate change test
WeissSC / KWT-1000 1000 Liter
Call
Condition: excellent (used), White
Type: SC / KWT - 1000
Technical data:
Salt spray mist test MIN 5 K > Tu MAX +50°C
Condensation water test MIN 5 K > Tu MAX +45°C
Humidifier MIN 5 K > Tu MAX +75°C
Temperature constancy
The temperature deviation over time is ±1 K
Dimension with hood:
Test chamber: H 1190 mm x W 1650 mm x D 570 mm
Dimensions without hood:
Test area: H 740 mm x W 1650 mm x D 570 mm
Dimensions with hood:
Outside: H 1370 mm x W 2730 mm x D 800 mm
Djb Hdrderh Dmqoqecg
Dimensions without hood:
Outside: H 920 mm x W 2730 mm x D 800 mm
Capacity approx. 700 - 1130 liters
3/N/PE AC 400V ±10%50Hz
Rated power 4 KW Rated current 7.5 A
Weight: 180 kg
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Vacuum drying oven
HeraeusVT 6025 200°C
Call
Condition: excellent (used), Heraeus
Type: VT 6025
Heraeus Vacutherm vacuum drying oven
Dcsbsrknagj Hdrdqjg
Specification jacket heating VT 6025
Temperature (metric) 200 °C
Dimensions, inside (W x D x H): 300 x 307 x 275 mm
External dimensions (W x D x H): 480 x 450 x 600 mm
Electrical requirements 230 V, 50/60 Hz
Frequency 50/60 Hz
Capacity (metric) 25 l
Heating jacket type without inert gas connection
Voltage 230 V 1.3 kW, 5.9 A
Weight: 58 kg
Condition: second-hand / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Temperature cabinet 335 liters
WeissWT3-340/40 -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss temperature chamber.
Weiss temperature test chamber With S!MCON / 32 control Water-cooled
(refrigerant converted to R-452A)
Touch panel" control unit
All control and operating commands can be triggered on the "touch panel" control unit by simply touching the function icons.
all control and operating commands by simply touching the function icons.
Levelling feet
To compensate for uneven floors and to ensure adequate ventilation of the machine part,
the test chamber is equipped with adjustable feet.
Feed-throughs
The test chamber is equipped with feed-throughs on the right and left side.
Measuring cables and test equipment can be routed through these into the test chamber.
Feed-through built into basic equipment
R1: NW 125 mm
L1: NW 50 mm
Test chamber capacity: approx. 335 liters
Test chamber dimensions: Height 750 mm, width 580 mm, depth 765 mm
External dimensions: Height 1775 mm, width 870 mm, depth 1600 mm
Data for temperature tests:
Temperature range: -42 to +180 °C
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate
Djb Hdrorbigfsdqocg
Heating: 3.2 K/min
Cooling: 4.0 K/min
Heat compensation max. 2300 W
Data for operation:
Test room lighting Halogen bulb 2x 24V, 50W
Rated voltage: 3/N / PE AC 400 V ± 10% 50 Hz
Rated current: 14 A Rated power 4.1 kW
On-site fuse 16 A slow-blow
Sound pressure level approx.
measured at a distance of 1 m from the front. 1m height 56 dB(A)
Refrigerant: R-452A
Weight: 515 kg
Type: WT3-340/40
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Extrusion plastometer Melt index test
ZwickRoellMflow
Call
Condition: excellent (used), Zwick / Roell
Type: Mflow
Area of application
With increasing test volumes, the need for a higher degree of automation also increases
(compared to the Cflow). The Mflow is a modularly expandable device,
with which you can determine the melt mass and melt volume flow rate.
The basic version of the Mflow extrusion plastometer is designed for MFR tests according to method A
and can be upgraded for MVR tests according to method B. Tests according to the following standards are possible:
- Methods A and B according to ISO 1133
- Methods A, B and C according to ASTM D 1238
- ASTM D 3364
- JIS K 7210
As an option, you can equip the Mflow with the pneumatic weight lift with and without cleaning function, for example.
without cleaning function or weight staking.
The Mflow can be operated both stand-alone via a modern touch display,
as well as with the ZwickRoell testing software on a PC.
Technical data
Test load: 0.325 - 21.6 kg
Compressed air, lubricated, dry: 6 - 10 bar
Dimensions
Height: 510 mm
Width: 360 mm
Depth: 419 mm
Weight: approx. approx.: 43 kg
Test temperature: +50°C - +450°C
Display: Capacitive touch display
Resolution of the temperature display: < 0.1 K
Number of storable parameter sets: >100
Temperature accuracy in the range 0 - 75 mm
above the nozzle in the temperature range 50°C - 450°C: < 0,3 K
Time measurement
Error limit (method A): ± 0.02 (with automatic cut-off device)
Error limit (method B): ± 0.01
Displacement measurement
Error limit (method B):
±0.02 mm (ISO 1133) /
±0.4 % of 6.25 mm
(ASTM D 1238)
Resolution: < 0.005
Multi-device operation on one PC:
Available working memory, min.: 1.54 GB
Clock frequency: 3 GHz
Connectable Mflow extrusion plastometers per PC: 6
Mains connection: 220 - 240 V, 1L/PE/N
Power consumption: 2.6 A
Mains frequency: 50/60 Hz
SW version: V4.2
Year of manufacture: 2021
Condition: used / second-hand
Scope of delivery: (see picture)
Dceb Hdetq Em Tsrdqsg
(Changes and errors in the technical data, specifications are reserved!)
We can answer further questions for you on the phone.
Listing

785 km
Temperature shock test system
RS SimulatorenST2K320/45 K
Call
Condition: excellent (used), RS. simulators
Type: ST2K320/45 K
Water-cooled shock test system
Temperatures in the upper test chamber
Temperature range: + 40 °C to + 180 °C
Time deviation: ± 0.8 K according to DIN 50011 with empty test chamber
Temperatures in the lower test chamber
Temperature range: - 40 °C to +100 °C
Time deviation: ± 0.8 K according to DIN 50011 with empty test chamber
Humidity in the upper test room
Climatic temperature range: + 40 °C to +90 °C
Humidity range: 20 % to 98 % (± 2 to 5 %) relative humidity
Humidity: 25% to 75% relative humidity
Working climate range:
Temperature: + 12 °C to + 30 °C
Humidity: 25 % to 75 % relative humidity
Dimensions: Width 900 mm Height 2000 mm Depth 2300 mm
Test room dimensions: Width 470 mm Depth 700 mm Height 440 mm
Electrical power supply:
Total power: 13 KVA
Current consumption: 25 A
Voltage: 3x400V/N/PE / 50Hz
Refrigerant: R404A/2.5 kg
Chamber: approx. 950 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
Dcob Hdrstrf Uljdqsg
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Climate chamber 38m³ Sunlight simulation
WeissWK 40'/40-120/So -40° bis +120°C
Call
Condition: excellent (used), Internal dimensions (net) H approx. 2150 mm W approx. 3000 mm D approx. 6000 mm
Air circulation system (on chamber rear wall) Width approx. 800 mm
External dimensions with machine unit and without control cabinets
Height approx. 3360 mm Width approx. 3320 mm Depth approx. 8620 mm
Machine room, attached to the rear wall of the chamber
Height approx. 2340 mm Width approx. 3320 mm Depth approx. 1500 mm
Electrical control cabinet, mounted on the side of the base frame
Height approx. 2340 mm Width approx. 2400 mm Depth approx. 600 mm
Chamber door (double-leaf)
Height approx. 2150 mm Width approx. 3000 mm
Pedestrian door (single-leaf)
Height approx. 1900 mm Width approx. 900 mm
Lighting (switch next to pedestrian door)
4 incandescent lamps 60W
Djbetrmm No Hdrdqjcg
Feed-throughs 4 pcs. 125 mm ∅
Floor load capacity
30,000 N/m² (surface load);
2,500 N per polyamide wheel Ø100mm;
4,000 N for a wheel with 4 cm²
Ceiling opening (clear dimensions of the lower disk)
Length approx. 600 mm Width approx. 700 mm
Quantity: 10 pieces
Ceiling load: 10 SoSi radiators + 1 person 90 kg
Working temperature range:
Temperature range -40 °C ... +120 °C (discontinuous)
Cooling speed:
approx. 1 K/min. linear from 80°C to -40°C with test specimen mass and without thermal load,
measured in the air outlet of the air circulation system.
At temperatures < (-20°C) the recirculated air volume is reduced by 50%.
(e.g. PV 1200)
Heating speed:
approx. 1 K/min. linear from -30°C to +90°C with test specimen mass and without thermal load,
measured in the air outlet of the air circulation system.
(e.g. PR 308.2)
Test specimen mass: 600 kg aluminum (vehicle - partial body)
Working range climate without sunlight simulation:
Temperature range: +10 °C ...+95 °C
Temperature constancy: ≤ ± 0.5 K (temporal)
Temperature constancy: ≤ ± 2 K (spatial)
Humidity range: 20 ... 80 % r.h., without thermal load
Dew point temperature range: -2 °C ...85 °C without thermal load
Climate working range with sunlight simulation:
Temperature range: +23 °C ...+50 °C
Temperature constancy: ≤ ± 0.5 K (temporal)
Humidity range: 20 ... 70 % r.h., with thermal load
Dew point temperature range: -2 °C ...43 °C without thermal load
Thermal load of the SoSi: Max. 10 kW
Temperature and humidity instances:
Temperature
The following maximum deviation is specified for the temperature in the climate and temperature range
(including measurement uncertainty and with test material):
Blow-out after 15 minutes: ±1K
Intake after 45 minutes: ±1.5K (external sensor)
Humidity
For the relative humidity at the operating point 80°C / 80% r.h.
the following maximum deviation (including measurement uncertainty and with test material) is specified:
Blow-out after 30 minutes: ±3% r.h.
Intake after 60 minutes: ±3% r.h. (external sensor)
Connection and consumption data:
Air-cooled refrigeration unit, maximum air temperature +38°C
Refrigerant R 404 A and R23
Water supply for humidifier:
Approx. 40 l/h = 40 kg/h installed steam output,
demineralized water, electrical conductivity 5-20 μS/m
Mains connection: 400 V; 3 PH + N + PE; 50 Hz
Connected load: 250 kVA, 350 A
Connection according to VDE 0110 group 2: 5x185 mm2 CU
On-site fuse protection: 355 A
Air circulation volume (FI-controlled): 24,000 to 28,000 m³/h
FC basic setting: 50% (achievement of the parameters)
Technical data solar simulation:
Manufacturer: BF Engineering GmbH
Type: G-BEM-1119
Number of lights: EPSU 2 x 2k_HQI
Ballast: 10
Ignitor: IGC-4k-03
Light source: OSRAM HQI 2000W High Flux
3〜/ N / PE
Listing

785 km
Climate test chamber with humidity 1000 liters
CTSC-40/1000 -40°C bis +180°C
Call
Condition: excellent (used), CTS
Type: C-40/1000
CTS climatic test chamber
Condenser chiller air-cooled
Control:
32 bit controller
LCD control panel
Digital display of setpoints and actual values
Numerical input of setpoints
Error messages in plain text
RS 232 interface
Free switching channels for on-site test material control
Temperature test:
Temperature range: -40°C to +180°C
Temperature change rate
Heating speed 2.0 K/min
Cooling rate 2.5 K/min
Temperature deviation ± 0.1 to ± 0.3 K in time
Heat radiation:
approx. 2500 W at +20°C
approx. 2500 W at ± 0°C
approx. 1500 W at -20°C
Climate Working range:
Temperature range +10°C to +95°C
Humidity range 10 to 98% r.h.
Dew point range I +7 to +94°C
Dew point range II -10 to +7°C
Temperature deviation ± 0.1 to ± 0.3 K in time
Humidity constancy I, temporal ± 0.5 to ± 1.5 % r.h.
Humidity constancy II, temporal ± 1 to ± 3 % r.h.
Panorama window 570 x 710 mm
Test chamber dimensions Width 1000 mm Depth 1100 mm Height 900 mm
External dimensions Width 1270 mm Depth 2220 mm Height 1950 mm
Test chamber volume 1000 liters
Pipe feed-throughs, ø 50
Electrical connection: 400 V +6/-10% 3/N, PE 50 Hz
Connected load: 8.4 kW Rated current: 12.4 A
Refrigerant: R-404A
Weight: 800 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
Dob Hdsru Dzujrdqjcg
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Temperature test chamber
Vötsch VT 4021
Call
Condition: used, Heraeus Vötsch
Dceb Hdeu Hf Hhjrdqog
Type: VT 4021
Heraeus Vötsch temperature test chamber air-cooled
Housing dimensions: Width 850 mm Depth 1250 mm Height 1640 mm
Interior: Width 560 mm Depth 570 mm Height 630 mm
Temperature range -40°C to + 180°C
Temperature deviation in time ±0.2 to ±0.5 K
Spatial temperature deviation ±0.5 to ±1.5 K
Temperature change rate cooling 3.1 K/min
Temperature change rate heating 2.5 K/min
Nominal voltage: 1/N/PE AC 230V±10% 50Hz
Rated power: 1.5 kW Rated current: 7 A
2X side feed-through 90 mm
Refrigerant: R-404A
Weight approx. 325 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Temperature chamber
HeraeusHT/S 7050
Call
Condition: excellent (used), Heraeus temperature chamber
Here we offer a temperature chamber.
Water-cooled
Outside: W x D x H (mm) 1100 x 2200 x 2320
Inside: W x D x H (mm) 800 x 800 x 790
Test chamber volume 500 L
Characteristic values for temperature tests:
Temp. range -70°C to +180°C
Heating speed: 3 K/min
Cooling speed: 2 K/min
Electrical power:
Rated power 15 kW Rated current 26 A
400 V +6/-10% 3/N 50Hz
Weights: 675 kg
Type: HT/S 7050
R404 A and R23
The following information is for your safety as a buyer!
Dcebju Efm So Hdrdqog
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Temperature test chamber 1540 liters
VötschVT³ 4150 -40°C bis +180°C
Call
Condition: excellent (used), Vötsch
Type: VT³ 4150
Vötsch temperature test chamber
Air-cooled
Rated voltage: 3/N/PE AC, 400 V ±10 %, 50 Hz
Rated power: 11.5 kW Rated current: 22.0 A
Rate of change: Cooling approx. 3.5 K/min.
Rate of change: Heating approx. 4 K/min.
Temperature test
Temperature range -40°C to + 180°C
Display plan
External dimensions: W x D x H approx. 1390 x 2380 x 1995 mm
Test chamber dimensions: W x D x H approx. 1100 x 1475 x 950 mm
Weight approx. 1020 kg / 1540 liters
Refrigerant R 404A
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Dcjb Hsu Nh Rbodrdqjg
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Corrosion test cabinet for salt spray
VLM CC 1000-FL HL V.745.672.120
Call
Condition: good (used), VLM
Type: V.745.672.120 Model CC 1000-FL HL
Corrosion test chamber for salt spray tests
Specifications:
Test chamber volume: approx. 1000 L
Test chamber dimensions (ΒχΤχΗ1/Η2): 1400x800x800/1020 mm
Deb Hdet Igc Sjrdqocg
Door opening dimensions (WxH): 1300x680 mm
External housing dimensions втн: 2162 x 995 x 2080 mm
Operating temperature range: 5°C > room temperature to +80°C
High-load version for loads up to 350 kg
Process control: Beckhoff PLC, color touch screen display
display, 50 memory locations for test procedures, 50
Memory locations for test segments, ramps:
Humidity-temperature over the entire working range,
Ether connection
Electrical connection: 400 V, 50 Hz, 5700 W
Tap water: min. 2.5 bar Tap connection 3/4"
External thread for connecting an ion exchanger cartridge
Compressed air: 7-8 bar
Waste water: Siphon / 30 mm ID hose nozzle
Exhaust air: pipe end OD 75 mm
Operating systems:
Salt spray
Condensation water (CWC)
Ventilation Room air
Warm air
Controlled humidity
Listing

785 km
Acoustic scanning microscope
SonixEcho VS Ultraschall Mikroskop
Call
Condition: excellent (used), Sonix
Type: Echo VS
Acoustic scanning microscope enables the inspection of packaging.
Features:
To detect the smallest and most subtle defects in state-of-the-art packaged microelectronics applications,
ECHO VS includes standard features such as heated water for optimal acoustic coupling,
flexible TAMI for efficient acquisition of the most useful data,
Deb Hdotz Rkmsrdqscg
Waveform Averaging for improved signal-to-noise ratio, ICEBERG for improved image quality and MFCI for improved image quality in the most demanding applications.
ECHO VS is the ultimate ultrasonic NDT device for molded flip chips, CSP, MCM, stacked die,
MUF and other advanced packaging technologies.
Detects air defects as small as 0.01 microns and spatially resolves defects down to 5 microns.
Image enhancement suite with heated water, waveform simulation and other innovations
for industry-leading image quality in advanced packaging applications
Image optimization for improved image quality in complex molded flip chips (MUF) and packages with polyimide layers
Waveform averaging for improved signal-to-noise ratio
Wide range of converters from very low to ultra-high frequency
Stacked Die Imaging (SDI) (optional)
Molded Flip Chip Imaging (MFCI)
Voltage / power consumption:
100-120/220-240 VAC
1PH/N/PE, 50/60 Hz 10 A
Condition: gebraucht / used
Scope of delivery: (see picture)
(Subject to changes and errors in the technical data and specifications!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Dryer for coating materials
Vötsch LTU 60/60
Call
Condition: excellent (used), Vötsch
Type: LTU 60/60
Heraeus Vötsch dryer for coating materials
Maximum concentration of flammable substances of 40 % of the lower explosion limit (LEL)
Highest temperature of the heating surface above 750 °C
Device description:
Technical data:
Interior (usable space) 0.216 m3
Internal dimensions: Width 600 mm Height 600 mm Depth 600 mm
External dimensions: Total width 796 mm Height 1725 mm Depth 850 mm
Loading / load capacity
Total roller conveyor 55 kg
Loading height above installation floor 820 mm
Weight (net) kg 275
Minimum exhaust air volume flow 96 m3/h
Purge time 5-fold air change 90 sec.
Increased recirculation air volume flow 33 m3/h
Total vapor space 0.414 m3
Sound pressure level (according to DIN 45635) < 70 dB(A)
Switch-off temperature
Temperature limiter (TB) fixed setting 300 °C
Temperature selector limiter (TWB) adjustable above nominal temperature 20
Temperature safety class (according to EN 60519-2)
Temperature limiter (TB) 1
Temperature selector limiter (TWB) 2
Nominal temperature 200 °C
Electrical data
Rated voltage / frequency 400V, 3/(N)PE, AC 50/60 Hz
Rated current 12.0 A
Nominal power 6.0 kW
Dcebjun Rrqs Hdrdqog
Connected load 7.0 kW
Weight: 275kg
Condition: second-hand / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Trust Seal
Dealers certified through Machineseeker

Listing

785 km
Vibration test system
RMSSWR 900 SW 3709 u. TGD 6000
Call
Condition: excellent (used), RMS
Type: SW 3509 + amplifier TGD 6000-000.00 and fan
Test Manager SWR 900
Power amplifier: TGD 6000
Vibration exciter: SW 3709
High-pressure fan HVM 80-100 GL 270
RMS electrodynamic vibration test system:
Technical data system:
Performance data
Max. Vector force sine 7.5 kN
Max. Vector force noise 6.75 kN
Max. Vector force shock 13.1 kN
Frequency range 0 - 3000 Hz
Mass of the vibrating system (Dyn.) 9 kg
Main resonance (unloaded) 2.5 kHz
Max. Amplitude (sine) 18 mm
(noise, shock) 26 mm
Max. speed (sine) 1.5 m/s
(noise, shock) 2.5 m/s
Max. Acceleration sine
vibrating system unloaded 833 m/s²
Additional load 10 kg 394 m/s²
Additional load 30 kg 192 m/s²
Additional load 50 kg 127 m/s²
Max. Acceleration noise
Additional load 30 kg 173 m/s²
Max. Acceleration shock
vibrating system unloaded 1450 m/s²
Additional load 30 kg 335 m/s²
Stray field
Stray field without counter field coil
On the table surface 20 mT
120mm above the table surface 7 mT
Stray field with counter field coil
On the table surface 10 mT
120mm above the table surface 2 mT
Vibration isolator
Operating range vertical/ horizontal
Resonant frequency 2.7 Hz
Operating air pressure 5 bar
Pneumatic weight compensation
Max. Weight compensation 250 kg
Operating air pressure 2.3 bar
Cooling Vibration exciter air
min. Cooling air volume 9 m/min
Max. exhaust air temperature (based on room temperature 35°C) 80°C
Power booster air
Heat dissipation to room air 1.5 kw
Emission:
Sound pressure level
1m - distance at a height of 1.6m 105 dBA
Electromagnetic field SW 3709
typ. 1.5 mT ( 50Hz)
typ. 0.5 mT (100Hz)
Electromagnetic field TGD 3000
typ. 150 HT (50Hz)
Dimensions / Weights
Table diameter / insert thread 224mm / M8
Vibration exciter with integrated isolators
Dsb Hsu Tud Hedrdqocg
970 × 695 x 950 mm (W x D x H)
Weight: 1200 kg
Power amplifier 550 x 700 x 2075 mm (W x D x H)
Weight: 270 kg
Cooling fan 839 x 582 x 900 mm (W x D x H)
Weight: 80 kg
Connection values:
Mains voltage +6/-10% 3 x 400V, 50Hz
Connected load 18 KVA
Power consumption (sweep mode sine wave) 12 kW
Total weight approx. 2000 kg
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Temperature test chamber 680 liters
Heraeus VötschVLM 3068/S -30 °C bis +125 °C
Call
Year of construction: 2010, Condition: excellent (used), Here we offer you a Heraeus Vötsch temperature test chamber.
Vötsch temperature test chamber VLM 3068/S air-cooled
(building material test chambers loaded from above)
Control panel
The control panel is mounted on a console on the temperature test chamber. By
control and operating commands can be triggered by simply touching the function symbols.
can be triggered. The operating instructions for the control panel are enclosed
Main switch
The main switch is located at the front of the temperature test chamber.
Air treatment room
The air treatment room is located in the test room
and contains the components required for temperature control.
In the air treatment room, the air is tempered (cooling/heating) and circulated by the test room fan.
circulated by the test room fan. The air is sucked in at the center of the side wall and
enters the test chamber again via the air baffles on the long sides.
Feed-throughs
The temperature test chamber can optionally be equipped with feed-throughs. Through these
can be used to route cables and test equipment into the test chamber.
Entry port front 2 x 82 mm ∅ rear 1 x 85 mm ∅
Internal dimensions Width 2000 mm Depth 570 mm Height 600 mm
External dimensions Width 3000 mm Depth 870 mm Height 1060 mm
Technical data:
Data for mechanical load:
Max. load with test material
Test area floor
(evenly distributed over the surface) 600 kg
Point load 50 kg
Data for temperature tests:
Temperature range -30 °C to +125 °C
Temperature deviation over time in the center of the usable space ±1 K
Temperature change rate
Heating approx. 1 K/min
Cooling approx. 2 K/min
Data for operation:
Nominal voltage 3/N / PE AC 400 V ±10% 50 Hz
Rated power 3 kW Rated current 9 A
Customer fuse 16A slow-blow
Temperature test chamber VLM 3068/S
Test chamber volume approx. 680 l
Weight approx. 700 kg
Refrigerant: R-404A
Noise measurement Sound pressure level approx. 68 dB(A)
Type: VLM 3068/S
Dcsb Hdjrbiyfsrdqsg
Condition: second-hand / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Climate test chamber 990 liters
WeissWK-1000/40/5 -40°C bis +180°C
Call
Condition: excellent (used), White
Type: WK-1000/40/5
Weiss climatic test chamber with Weiss air-cooled condenser
S!MCON / 32 control unit
Test chamber capacity: approx. 990 liters
Test chamber dimensions: Height 950 mm, width 1100 mm, depth 950 mm,
External dimensions: Height 1995 mm, width 1390 mm, depth 1855 mm,
Data for operation:
Test room lighting Halogen bulb 24V, 50W
Nominal voltage: 3/N / PE AC 400 V ± 10% 50 Hz
Rated power 23 KW
Rated current: 33 A
Debou Ap Sms Hdrdqecg
Data for temperature tests:
Temperature range: -40 to +180 °C
Temperature deviation in time in the center of the usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 2 K
Temperature change rate
Heating: 6.1 K/min
Cooling: 6.7 K/min
Heat compensation max. 5000 W
Data for climate tests
Temperature range: +10 to +95 °C
Humidity range: 10 to 98 % r.h.
Temperature deviation in time in the center of the usable space: ± 0.1 to ± 0.3 K
Spatial temperature deviation: ± 0.5 to ± 1 K
Humidity fluctuation over time in the center of the usable space: ± 1 to ± 3 % r.h.
Dimensions incl. feet
Width x depth x height: 1190 x 1120 x 1093 mm
Refrigerant: R404 A 5.2 kg
Weight: approx. 840 kg
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Vacuum drying oven
HeraeusVT 6025 200°C
Call
Condition: excellent (used), Heraeus
Djb Hdsrm Rihordqecg
Type: VT 6025
Heraeus Vacutherm vacuum drying oven
Specification jacket heating VT 6025
Temperature (metric) 200 °C
Dimensions, inside (W x D x H): 300 x 307 x 275 mm
External dimensions (W x D x H): 480 x 450 x 600 mm
Electrical requirements 230 V, 50/60 Hz
Frequency 50/60 Hz
Capacity (metric) 25 l
Heating jacket type without inert gas connection
Voltage 230 V 1.3 kW, 5.9 A
Weight: 58 kg
Condition: second-hand / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
We make the search easier for you
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Material testing (493)
Search Machineseeker now with more than 200,000 used machines:This may be of interest to you

Find out now
+44 20 806 810 84
+44 20 806 810 84
Create listing
*per listing / month