Used Material testing for sale (495)
Sort results
- Lowest price Highest price
- Latest listings Oldest listings
- Shortest distance Farthest distance
- Latest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Latest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Latest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation A to Z
- Designation
- designation Z to A
- Designation
- Model A to Z
- Model
- Model Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest running time
- Runtime
- Relevance
- Relevance
Measuring & testing equipment Material testing
Listing

785 km
Shaker system with amplifier
LDSV895-440 HBT900C + SPA50K
Call
Condition: excellent (used), LDS
Type: V895-440 HBT900C with amplifier SPA50K
Technical data:
Fitting Dimensions: 440 mm
Sinusoidal force vector 55.6 kN (peak)
Rausch force vector 55.6 kN (effective)
Half sine force vector 166.8 kN (peak)
Frequency range 0 to 2100 Hz
Sinusoidal acceleration max. 981 m/s²
Noise Acceleration max. 490 m/s²
Speed max. 1.6 m/s
Deflection ± 63.5 mm
Oscillator mass 55 kg
Max. load 700 kg
Amplifier dimensions :
Cebsuy H I Ts Hc Ailsgt
WxHxD mm : 537mm x 1905mm x 895mm
Weight 622 kg
Sliding table:
Work surface: 900 mm * 900 mm
Thickness of the top : 50 mm
Weight of the top: 80.4 kg
Max load : 7250kg
Effective frequency range 5-2000 Hz
Condition : gebraucht / used
Total weight (table + shaker): approx. 7000 kg
Shaker + table dimensions: LxHxW approx. 2700 x 1500 x 1800 mm
Scope of delivery: (see pictures)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Climate test chamber 990 liters
WeissWK-1000/40/5 -40°C bis +180°C
Call
Condition: excellent (used), White
Type: WK-1000/40/5
Weiss climatic test chamber with Weiss air-cooled condenser
S!MCON / 32 control unit
Test chamber capacity: approx. 990 liters
Test chamber dimensions: Height 950 mm, width 1100 mm, depth 950 mm,
External dimensions: Height 1995 mm, width 1390 mm, depth 1855 mm,
Data for operation:
Test room lighting Halogen bulb 24V, 50W
Nominal voltage: 3/N / PE AC 400 V ± 10% 50 Hz
Rated power 23 KW
Rated current: 33 A
Data for temperature tests:
Temperature range: -40 to +180 °C
Temperature deviation in time in the center of the usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 2 K
Temperature change rate
Heating: 6.1 K/min
Cooling: 6.7 K/min
Heat compensation max. 5000 W
Data for climate tests
Cjb Hc Aieu Ap Smsljgt
Temperature range: +10 to +95 °C
Humidity range: 10 to 98 % r.h.
Temperature deviation in time in the center of the usable space: ± 0.1 to ± 0.3 K
Spatial temperature deviation: ± 0.5 to ± 1 K
Humidity fluctuation over time in the center of the usable space: ± 1 to ± 3 % r.h.
Dimensions incl. feet
Width x depth x height: 1190 x 1120 x 1093 mm
Refrigerant: R404 A 5.2 kg
Weight: approx. 840 kg
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Temperature test chamber
Vötsch VT 4021
Call
Condition: used, Heraeus Vötsch
Type: VT 4021
Heraeus Vötsch temperature test chamber air-cooled
Housing dimensions: Width 850 mm Depth 1250 mm Height 1640 mm
Interior: Width 560 mm Depth 570 mm Height 630 mm
Temperature range -40°C to + 180°C
Temperature deviation in time ±0.2 to ±0.5 K
Spatial temperature deviation ±0.5 to ±1.5 K
Temperature change rate cooling 3.1 K/min
Temperature change rate heating 2.5 K/min
Nominal voltage: 1/N/PE AC 230V±10% 50Hz
Rated power: 1.5 kW Rated current: 7 A
2X side feed-through 90 mm
Refrigerant: R-404A
Cgjb Hc Asu Hf Hheilst
Weight approx. 325 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Vibration test system
RMSSWR 900 SW 3709 u. TGD 6000
Call
Condition: excellent (used), RMS
Type: SW 3509 + amplifier TGD 6000-000.00 and fan
Test Manager SWR 900
Power amplifier: TGD 6000
Vibration exciter: SW 3709
High-pressure fan HVM 80-100 GL 270
RMS electrodynamic vibration test system:
Technical data system:
Performance data
Max. Vector force sine 7.5 kN
Max. Vector force noise 6.75 kN
Max. Vector force shock 13.1 kN
Frequency range 0 - 3000 Hz
Mass of the vibrating system (Dyn.) 9 kg
Main resonance (unloaded) 2.5 kHz
Max. Amplitude (sine) 18 mm
(noise, shock) 26 mm
Max. speed (sine) 1.5 m/s
(noise, shock) 2.5 m/s
Max. Acceleration sine
vibrating system unloaded 833 m/s²
Additional load 10 kg 394 m/s²
Additional load 30 kg 192 m/s²
Additional load 50 kg 127 m/s²
Max. Acceleration noise
Additional load 30 kg 173 m/s²
Max. Acceleration shock
vibrating system unloaded 1450 m/s²
Additional load 30 kg 335 m/s²
Stray field
Stray field without counter field coil
On the table surface 20 mT
Cgob Hcou Tud Hs Ailst
120mm above the table surface 7 mT
Stray field with counter field coil
On the table surface 10 mT
120mm above the table surface 2 mT
Vibration isolator
Operating range vertical/ horizontal
Resonant frequency 2.7 Hz
Operating air pressure 5 bar
Pneumatic weight compensation
Max. Weight compensation 250 kg
Operating air pressure 2.3 bar
Cooling Vibration exciter air
min. Cooling air volume 9 m/min
Max. exhaust air temperature (based on room temperature 35°C) 80°C
Power booster air
Heat dissipation to room air 1.5 kw
Emission:
Sound pressure level
1m - distance at a height of 1.6m 105 dBA
Electromagnetic field SW 3709
typ. 1.5 mT ( 50Hz)
typ. 0.5 mT (100Hz)
Electromagnetic field TGD 3000
typ. 150 HT (50Hz)
Dimensions / Weights
Table diameter / insert thread 224mm / M8
Vibration exciter with integrated isolators
970 × 695 x 950 mm (W x D x H)
Weight: 1200 kg
Power amplifier 550 x 700 x 2075 mm (W x D x H)
Weight: 270 kg
Cooling fan 839 x 582 x 900 mm (W x D x H)
Weight: 80 kg
Connection values:
Mains voltage +6/-10% 3 x 400V, 50Hz
Connected load 18 KVA
Power consumption (sweep mode sine wave) 12 kW
Total weight approx. 2000 kg
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
C02 incubator CO2 incubator
JouanIG 150
Call
Condition: good (used), Here we offer a Jouan C02 incubator CO2 incubator.
The CO2 incubator is used to grow cell cultures.
The following conditions are required for this:
a sterile atmosphere
a constant temperature
a CO2-enriched atmosphere
high humidity
Dimensions and weight:
Temperature range: room temperature + 5 ° C to 50 ° C
CO2 detector: Infrared
Size: 90 x 73 x 60cm
Internal dimensions: 66 x 48 x 45 cm
Outer material: steel
Interior material: Stainless steel
Inner door: Safety glass
CO2 Incubator Jouan IG 150
Water jacket volume 85 liters maximum
Volume 154 liters
Maximum number of trays (3 supplied)
Usable area per tray 0.16 m2
Usable maximum incubation area: 1.28 m2
minimum spacing height 66 mm
empty weight approx. 80 kg
Weight when filled with water approx. 170 kg
Weight with packaging approx. 100 kg
Power connection required: 230 V, 50 or 60 Hz.
Power consumption max. 800 VA, normal consumption at 37 °C: 220 watts
Fuses therm. Magnetic switch, set to 5 A at 220 V Phases earthed.
Color of connections brown = phase, blue = neutral, yellow/green = earth
Working range:
Ambient temperature 15 - 30°C
CO2 inlet pressure 300 mbar - 3 bar
Cgjb Hceccb N Uo Ailot
Interior temperature range from 5°C above room temperature to 45°C
Working range with CO2 gas 0.0 % to 20.0 0/0
Article weight: 80.00 kg
Type IG 150
Scope of delivery: (see picture)
2 weeks commissioning guarantee
The device comes from stock.
We deliver with express shipping (DHL, UPS, TNT)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Test chamber for parametric test
S & A55°C bis +150°C 4220A
Call
Condition: good (used), Here we offer you an S & A test chamber for parametric testing.
Ceb Hjcnic Ssc Ailsgt
S & A test chamber for parametric testing
Temperature range: 55°C to +150°C
Stability:
± 0.1 ° C including the effects of mains voltage, ambient temperature and ageing.
temperature and ageing
Cooling medium: Water-cooled mechanical cooling
Chamber can be controlled remotely via IEEE bus or
RS232C interface
Weight approx. 250 kg
Type: 4220A
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Laboratory furnace
DespatchLCC1-16NV-3
Call
Condition: excellent (used), Here we offer a Despatch lab oven.
Despatch Laboratory Ovens
+ 8 "WAFER
LCC: Maximum temperature 260 ° C
Lockable circuit breakers turn on the control panel for easy maintenance
Protocol 3 control with large LCD display, built-in data logging capabilities and USB port for easy oven setup and data export
Edelstellenne room with interior seams welded continuously on the insulation side to protect the working space from pollution
Programmable door locking prevents the operator from opening the oven door while the cycle is running
The door lock switch turns off the heating when the door is open
The rolled air flow consists of 100% HEPA (High Efficiency Particulate Air) and is filtered to ISO Class 5 (Class 100) throughout the process cycle
The Magnehelic Manometer monitors the pressure drop of the HEPA filter so you know when to replace the filter
Electric door unlocking for ergonomic operation
UL & C-UL Listed Control Panel Open
Modbus communication connection (RS485) for remote monitoring and recording
Chamber measure L 350 mm
Csb Hjd Nfq Iec Ailegt
Chamber measure B 350 mm
Chamber Measure H 350 mm
Maximum temperature 260°C
Digital screen Yes
Electric connection 230 V
Total size L 830 mm
Total dimensions B 910 mm
Total Measure H 560 mm
Type: LCC1-16NV-3
Condition: used/used
Delivery: (See picture)
(Changes and errors in technical D
Listing

785 km
Climate test chamber 2500 liters
VötschVC 4200/S -40°C bis +180°C
Call
Condition: excellent (used), Vötsch
Type: VC 4200/S
Climate test chamber 2500 liters water-cooled
Temperature test:
Temperature range -40°C to + 180°C
Temperature deviation in time: ± 0.3 to ± 1.0
Spatial temperature deviation: ± 1.0 to ± 2.0
Temperature gradient 2 to 4
Heating speed: 2.0 K/min
Cooling rate: 3.0 K/min
Climatic tests:
Temperature range: +10 °C to +90 °C
Temperature deviation over time: ± 0.1 to ± 0.5
Temperature deviation over time: ± 1 to ± 1.5
Temperature gradient 2 to 3
Humidity range: 10% to 98% r.h.
Humidity deviation over time: + 1 to 3 % r.h.
Dew point range +5 to +89°C
Test room dimensions: Width approx. 2000 mm x depth 1150 mm x height 1150 mm
External dimensions: Width approx. 3500 mm x depth 1450 mm x height 2100 mm
Nominal voltage 3/N/PE AC 400 V ±10%50Hz
Rated power 13 kW
Nominal current 21 A
Refrigerant R-452A
Weight approx. 1350 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Csbou Au Uts Hc Ailogt
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Temperature chamber
HeraeusHT/S 7050
Call
Condition: excellent (used), Heraeus temperature chamber
Here we offer a temperature chamber.
Water-cooled
Outside: W x D x H (mm) 1100 x 2200 x 2320
Inside: W x D x H (mm) 800 x 800 x 790
Test chamber volume 500 L
Characteristic values for temperature tests:
Cjb Hc Aiju Efm Soljgt
Temp. range -70°C to +180°C
Heating speed: 3 K/min
Cooling speed: 2 K/min
Electrical power:
Rated power 15 kW Rated current 26 A
400 V +6/-10% 3/N 50Hz
Weights: 675 kg
Type: HT/S 7050
R404 A and R23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Temperature test chamber 1540 liters
VötschVT³ 4150 -40°C bis +180°C
Call
Condition: excellent (used), Vötsch
Type: VT³ 4150
Vötsch temperature test chamber
Air-cooled
Rated voltage: 3/N/PE AC, 400 V ±10 %, 50 Hz
Rated power: 11.5 kW Rated current: 22.0 A
Rate of change: Cooling approx. 3.5 K/min.
Rate of change: Heating approx. 4 K/min.
Cgob Hc Aeu Nh Rbeilot
Temperature test
Temperature range -40°C to + 180°C
Display plan
External dimensions: W x D x H approx. 1390 x 2380 x 1995 mm
Test chamber dimensions: W x D x H approx. 1100 x 1475 x 950 mm
Weight approx. 1020 kg / 1540 liters
Refrigerant R 404A
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Temperature test chamber 600 liters
CTST-70/600 -70°C bis 180°C
Call
Condition: excellent (used), CTS
Cgsbsvaxq Ns Hc Ailot
Climatic test chamber T-70/600 water-cooled
Temperature range: -70°C to +180°C
Rated voltage: 400V 3/N PE 50 Hz
Rated power: 6.7 kW
Rated current: 10.2 A
Compressor: TFH2480Z/TFH2511Z Refrigerant R23/R404A
Control system:
-Microprocessor-controlled control and monitoring system
Simple, user-friendly terminal built into the door.
-Digital temperature setpoint and actual value display
Simple variation via +/- button
-Digital input for temperature in °C
-PLC compatible
-Up to 100 test programs possible
-RS 232 interface
-2 free switching channels for on-site
test material control
Insert grid:
Stainless steel, contact surface 820 x 710 mm
Load per grid max. 35 kg
Total load with max. grid configuration 100 kg
Cooling unit:
Water-cooled, low-noise, fully hermetic Infinitely variable power adjustment
through electronic monitoring and control system,
environmentally friendly refrigerant R404A/R23
Temperature tests:
Temperature range -70 °C to+ 180 °C
Temperature deviation ±0.1 to 10.3 K in time
Rate of temperature change
according to DIN 50 011, part 12 measured in the center of the test room
Heating 2.5 K/min
Cooling 2 K/min
Heat radiation max. 1500 W at +20°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400 V, without test material, without irradiation and without additional equipment.
Dimensions:
Test volume 600 liters
Test chamber dimensions 850 x 830 x 850 mm (W x Dx H)
External dimensions 1050 x 1850 x 1900 mm (W x DxH)
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 6.7 kW
Rated current: 10.2 A
Protection class IP 22
Condensate drain unpressurized R 1/2" internal thread
Sound pressure level < 62 dB(A)
Weight approx. 400 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Temperature test chamber
CTS TS -70/600-13
Call
Condition: used, CTS
Type: TS -70/600-13
Temperature test chamber, water-cooled
Type series: TS -70/600-13
Control system:
- 32 bit controller
- LCD control panel
- Digital display of setpoints and actual values
- Numerical input of setpoint values
- Error messages in plain text
- RS 232 interface
- Free switching channels for on-site test material control
Test chamber volume: 600 liters
Test chamber dimensions: Height approx. 730 mm, width approx. 850 mm, depth approx. 830 mm
External dimensions: Height approx. 2250 mm, width approx. 1300 mm, depth approx. 2475 mm
Cgob Hc Asvcyawoilst
Temperature range: -70 to +180°C
Heating speed: 13 K/min at -40°C to +120°C
Cooling speed: 13 K/min at 120°C to -40°C
Temperature deviation: ± 0.1K temporal, ± 0.5 K spatial
Electrical connection 400/3P/N/PE
Nominal power: approx. 27.8 kW
Nominal current: approx. 44.1 A
Compressor: 4TC-8.2Y/4PC-10.2Y
Refrigerant: R-404 A / R-23
Weight: 1350 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Climatic test chamber -40 to +180°C
WeissWK-480/40/10 480 Liter m. Feuchte
Call
Condition: excellent (used), Here we offer a Weiss climatic test chamber.
Water-cooled
Test chamber lighting Halogen bulb 24V, 50W
Data for temperature tests:
Temperature range: -40°C to +180°C
Temporal temperature deviation in the center of the chamber: ± 0.3 to ± 0.8 K
Spatial temperature deviation: ± 0.5 to ± 2 K
Temperature change rate
Heating: 10 K/min
Cooling: 12.5 K/min
Heat compensation at +20°C 8000 W
Heat compensation at -20°C 3000 W
Data for climate tests
Temperature range: +10°C to +95°C
Humidity range: 10 to 98 % r.h.
Temperature deviation in time in the center of the usable space: ± 0.2 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1 K
Humidity fluctuation over time in the center of the usable space: ± 1 to ± 3 % RH
Test chamber dimensions: Height 950 mm, width 760 mm, depth 650 mm,
External dimensions: Height 2025 mm, width 1090 mm, depth 2480 mm,
Nominal voltage: 3/N/PE AC 400 V ± 10% 50 Hz
Rated current: 24 A Rated power: 16.0 KW
Refrigerant: R452A
Weight: approx. 900 kg
Type: WK-480/40/10
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
Csbeq Dpzye Hc Ailegt
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Temperature cabinet 335 liters
WeissWT3-340/40 -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss temperature chamber.
Weiss temperature test chamber With S!MCON / 32 control Water-cooled
(refrigerant converted to R-452A)
Touch panel" control unit
All control and operating commands can be triggered on the "touch panel" control unit by simply touching the function icons.
all control and operating commands by simply touching the function icons.
Levelling feet
To compensate for uneven floors and to ensure adequate ventilation of the machine part,
the test chamber is equipped with adjustable feet.
Feed-throughs
The test chamber is equipped with feed-throughs on the right and left side.
Measuring cables and test equipment can be routed through these into the test chamber.
Feed-through built into basic equipment
R1: NW 125 mm
L1: NW 50 mm
Test chamber capacity: approx. 335 liters
Test chamber dimensions: Height 750 mm, width 580 mm, depth 765 mm
External dimensions: Height 1775 mm, width 870 mm, depth 1600 mm
Data for temperature tests:
Temperature range: -42 to +180 °C
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.5 K
Cgob Hc Aerbigfeiljt
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate
Heating: 3.2 K/min
Cooling: 4.0 K/min
Heat compensation max. 2300 W
Data for operation:
Test room lighting Halogen bulb 2x 24V, 50W
Rated voltage: 3/N / PE AC 400 V ± 10% 50 Hz
Rated current: 14 A Rated power 4.1 kW
On-site fuse 16 A slow-blow
Sound pressure level approx.
measured at a distance of 1 m from the front. 1m height 56 dB(A)
Refrigerant: R-452A
Weight: 515 kg
Type: WT3-340/40
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Vacuum drying oven
HeraeusVT 6025 200°C
Call
Condition: excellent (used), Heraeus
Type: VT 6025
Heraeus Vacutherm vacuum drying oven
Specification jacket heating VT 6025
Temperature (metric) 200 °C
Dimensions, inside (W x D x H): 300 x 307 x 275 mm
External dimensions (W x D x H): 480 x 450 x 600 mm
Electrical requirements 230 V, 50/60 Hz
Frequency 50/60 Hz
Capacity (metric) 25 l
Heating jacket type without inert gas connection
Voltage 230 V 1.3 kW, 5.9 A
Weight: 58 kg
Condition: second-hand / used
Cgoberm Riho Hc Ailot
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Climate test chamber with humidity 1000 liters
CTSC-40/1000 -40°C bis +180°C
Call
Condition: excellent (used), CTS
Type: C-40/1000
CTS climatic test chamber
Condenser chiller air-cooled
Control:
32 bit controller
LCD control panel
Csboru Dzuj Hc Ailegt
Digital display of setpoints and actual values
Numerical input of setpoints
Error messages in plain text
RS 232 interface
Free switching channels for on-site test material control
Temperature test:
Temperature range: -40°C to +180°C
Temperature change rate
Heating speed 2.0 K/min
Cooling rate 2.5 K/min
Temperature deviation ± 0.1 to ± 0.3 K in time
Heat radiation:
approx. 2500 W at +20°C
approx. 2500 W at ± 0°C
approx. 1500 W at -20°C
Climate Working range:
Temperature range +10°C to +95°C
Humidity range 10 to 98% r.h.
Dew point range I +7 to +94°C
Dew point range II -10 to +7°C
Temperature deviation ± 0.1 to ± 0.3 K in time
Humidity constancy I, temporal ± 0.5 to ± 1.5 % r.h.
Humidity constancy II, temporal ± 1 to ± 3 % r.h.
Panorama window 570 x 710 mm
Test chamber dimensions Width 1000 mm Depth 1100 mm Height 900 mm
External dimensions Width 1270 mm Depth 2220 mm Height 1950 mm
Test chamber volume 1000 liters
Pipe feed-throughs, ø 50
Electrical connection: 400 V +6/-10% 3/N, PE 50 Hz
Connected load: 8.4 kW Rated current: 12.4 A
Refrigerant: R-404A
Weight: 800 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

785 km
Vibration test system
RMSSW 1507 / TGA 1500
Call
Condition: excellent (used), RMS vibration exciter with power amplifier and cooling fan
Here we offer you a RMS vibration exciter with power amplifier.
Vibration exciter SW 1507
Max force 2158 N
max. speed 1,3 ms
Power amplifier TGA 1500
3 x 380V/ 50Hz/ 35A / 8 kVA
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Written order possible by email or fax
Cgeb Hc Aijgkaibelst
Listing

785 km
Temperature shock chamber
EspecTSA-201 SW
Call
Condition: excellent (used), Espec Temperature Shock Chamber
Here we offer you an Espec temperature shock chamber.
Thermal shock environmental chamber (cold load: -65° to 0°C). Conventional thermal shock chambers with three zones can be quite large because three separate chambers are used.
The TSA series has only one chamber, significantly reducing its size. Instead, it circulates cold, hot or ambient air as needed.
The conditioned air can be precooled or preheated beyond the set point, allowing for faster recovery to the desired condition after transfer.
Espec Temperature Shock Chamber Water Cooled TSA-201S SN: 153000154
Hot chamber: +60 to 200°C Cold chamber: -70 to 0°C
Working temperature: 0-40°C
System: two zone or three zone test by flap switching.
Performance:
Test range:
High temperature. Exposure range: +60 to +200°C
Low temperature. Exposure range: -70 to 0°C
Temperature variation ±0.5°C
Hot chamber:
Temperature Heating time: ambient temp. to +200°C within 15 min.
Cooling chamber:
Temperature Pulldown time: ambient temp. to -75°C within 45 min.
Temperature recovery: within 10 min.
Inner dimensions (W x H x D mm): 650 x 460 x 670
External dimensions (W x H x D mm): 1550 x 1900 x 1670
Power supply: 380/400/415V AC 50Hz: 70 A
Refrigerant: R404/R23
Weight: approx. 1400 kg
Cgjbog S Ugke Hc Ailet
Type: Espec Model: TSA-201 SW
For you as a buyer, the following information for your safety!
The following points are checked on our offered chambers in advance.
Listing

785 km
Vibration test system
RMSSW 3006 mit TGA 1500
Call
Condition: excellent (used), RMS Vibration Test System
Here we offer you a RMS electrodynamic vibration test equipment.
RMS Vibration Test System
Vibration exciter SW 3006
Power amplifier TGA 1500
Technical data:
Sine:3,7 kN
Noise:3,7 kN
Shock:3.7 kN
Displacement pk-pk:26 mm
Cgeb Hehyly Roc Ailot
Speed: 0.9 m/s
Acceleration: 80 g
Cooling: air cooled
Condition: used / used
Untested! Tests were not possible
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Written order possible by email or fax
Listing

785 km
Chamber convection oven
EliogKU 300/09-06-06/2
Call
Condition: excellent (used), Eliog
Here we offer you a chamber air circulation furnace.
Usable space dimensions : height mm 900 / width mm 600 / depth mm 600
324 liters
Outer dimensions : height mm 1775 / width mm 900 / depth mm 953
Door leaf 1
Connected load: 3X400V 50 Hz 13 kVA
Csb Hjifkiijc Ailogt
Heating power: 12 kW
Nominal temperature: 300°C
weight: 400 kg
Type: KU 300/09-06/2 K1051071
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

785 km
Emission test chamber 480 liters
VötschVCE 1000/S +20°C bis +130°C
Call
Condition: excellent (used), Here we offer you a Vötsch emission chamber.
Water cooled
Test chamber volume 1000 liters (usable) (916) liters Adjustment tank 480 liters
Performance for temperature tests:
Temperature range +20°C to +130°C
Cgsb Hcsi Hbylo Ailet
Temperature deviation temporal K ±0.1 to ±0.3
Temperature deviation spatial K ±0,5
Temperature gradient K 1
Temperature rate of change:
Cooling K/min 0.3
Heating K/min 0,4
Performance for climatic tests:
Carrier gas conditioning with climatic module
according to the evaporation principle
Temperature range +20°C to +130°C
Humidity range 5 to 95%
Dew point range +5°C to +60°C
Humidity deviation in time % ±1 to ±3
Carrier gas exchange rate 0.1 to 1.8 chamber volume per hr.
Capacity range for desorption
Desorption temperature up to max. +240°C, adjustable
Test chamber surface temperature between +220°C and +240°C
Purge rate max. 4 m³/h
Test chamber dimensions: Width 750 mm Depth 1630 mm Height 750 mm
test chamber door 670 x 670 mm
Outer dimensions: Width 1350 mm Height 2950 mm Height 2050 mm
rated current 32 A
nominal power 19,0 kW
Electrical connection 3/N/PE AC 400V ± 10% 50Hz
Weight 1200 kg
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Type: VCE 1000/S
Condition: used / used
Scope of delivery: (See picture)
Sale ex location
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Trust Seal
Dealers certified through Machineseeker

Listing

785 km
Analytical drift detector
Oxford InstrumentsINCAx-act
Call
Condition: excellent (used), Oxford Instruments
Here we offer you an INCAx-act Analytical Drift Detector.
Microanalysis of elements including boron and above
Operating temperature
Normal mode 10-25 degrees
Operating temperature
extended mode 10-30 degrees
Cob Hc Aiehx Ncholegt
Storage temperature
-25 to 40 degrees and 8 to 80% humidity non-condensing
Operating humidity
Listing

785 km
Temperature chamber
WEISSWT1-340/30
Call
Condition: excellent (used), Weiss temperature chamber
Here we offer Weiss temperature chamber.
Converted to R452a
Weiss temperature chamber air cooled
Temperature range: from - 30°C to 180°C
Temperature change rate cooling 1,6 K/min
Temperature change rate heating 2,1 K/min
Ceb Hc Asic Rgfsilegt
Test chamber dimensions: Width 550 mm x depth 750 mm x height 800 mm
Housing dimensions: Width 800 mm x depth 1500 mm x heights 1800 mm
Voltage: 3/N/PE AC 400V±10% 50Hz
Rated power 4,9 kW Rated current 9 A
Refrigerant: R452a
Weight: 515 kg
Type: WT1-340/30
For you as a buyer the following information for safety!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

785 km
Temperature test chamber ex protected
CTS-30°C bis +80°C T-30/950 Ex/I
Call
Year of construction: 2011, Condition: excellent (used), Here we offer you CTS temperature test chamber.
Control-32 bit controller
LCD control panel
Digital display of set and actual values
Numerical input of the setpoints
Error messages in plain text
Interface RS 232
Free switching channels for on-site test material control
Temperature tests:
temperature range -30°C to +80°C
temperature deviation ±0,3 K temporally
Temperature change rate
heating 2 K/min
Cooling 1.5 K/min to -10°C
Heat radiation approx. 1000 W at +20°C
approx. 200 W at -25°C
Data for gas supply:
Temperature range: -25°C to +55°C
Temperature deviation: ±0.25 K to the test space
Temperature change rate measured on average at a gas flow of 10 Nm³/h: at least as fast as the test chamber
Data for the gas return:
Temperature range: +18°C to +30°C
Temperature deviation: ±0.25 K to the test chamber
Nitrogen inerting with residual oxygen monitoring
With nitrogen inerting, the test chamber is first purged with the large purge volume N2 until the
oxygen content is less than 3%. After that, the system switches to a base load (approx. 10% of the large flush volume).
is switched over.
The nitrogen flow rate of the base load is measured with a flow meter, displayed and monitored by a limit switch.
and monitored by means of a limit switch.
The O2 monitoring system continuously extracts from the test chamber via a flashback arrestor
gas from the test chamber via a flame arrester and passes it over an O2 sensor that monitors the residual oxygen content of the extracted air.
The gas is then returned to the test chamber via a second flashback arrestor.
test chamber. The exhaust pump is monitored by a volumetric flow meter. Further details can be found
can be found in the Dräger operating instructions in the appendix.
The gas device is currently out of service!
The technical data refer to an ambient temperature of +25 °C,
Nominal voltage 400V , without test material, without irradiation and without additional equipment.
Dimensions:
Test volume 950 liters
Test chamber dimensions height approx. 700 mm / width approx. 900 mm depth approx. 1500 mm
External dimensions height approx. 2400 mm / width approx. 1270 mm depth approx. 3125 mm
Operating data:
Electrical connection 400V+6/-10 %, 3/N,50 Hz
rated power 21,6 kW
rated current: 36,5 A
Protection class IP 54
condensate drain pressureless R 1/2" female thread
Sound pressure level < 62 dB(A)
(according to DIN EN ISO 3744
measured at 1m distance from front)
weight: approx. 1500 kg, control cabinet approx. 300 kg
external refrigeration unit
refrigerant R404A / R23
Type: T-30/950 Ex/I
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Ceb Hceihb Ame Ailsgt
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

785 km
Shaft meter
MahrHelio-Pan II 700
Call
Condition: excellent (used), Mahr
Here we offer you a Helio-Pan II.
max. workpiece weight 30 kg at center height 100 mm
80 kg with center height 150 mm
measuring range length 0 mm to 700 mm
measuring range outer diameter 0 mm to 120 mm
max. throwing distance to be measured 100 mm
Cgeb Hcsi Ezh Us Ailot
tip height 100 mm
Measuring blades probe and caliper 1 mm x 5 mm
Dimension (W x D x H)
machine 2060 mm x 920 mm x 1750 mm
controller box 600 mm x 800 mm x 2200 mm
Weight approx. 900 kg
Electrical power 230 V / 1200 W / 50 Hz
Air pressure 6 bar
Type: Helio-Pan II 700
Scope of delivery: (See picture)
Further questions we can answer on the phone for you.
Written order possible by email or fax
We make the search easier for you
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Material testing (495)
Search Machineseeker now with more than 200,000 used machines:This may be of interest to you