Used Climatic Test Chamber for sale (16,143)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing

838 km
Climate test chamber with humidity
WeissWKL 34/40
Call
Year of construction: 2011, operating hours: 3,210 h, condition: excellent (used), Climate test chamber, climate chamber, temperature test chamber WKL 34/40 by Weiss Umwelttechnik
Test chamber volume approx. 34 liters
Internal dimensions approx. 340 x 310 x 280 mm
1 shelf
Test chamber lighting: halogen
Power: 1.8 kW, 230 volts
0.8 kg refrigerant R404A
Hfodow U U Nhjpfx Ag Nen
Temperature range: -40 to +180°C
Humidity range: 10 to 98% rH
Water tank for 13 liters of demineralized water
Simpati control system, color touch display
Test programs in automatic mode or manual for temperature and humidity only
CE mark
Very well-maintained heating chamber from prototype production in the motorsport department of a Wolfsburg-based automobile manufacturer.
Only 3,210 operating hours.
Unfortunately, no key available.
Dimensions approx. 580 x 950 x 980 mm (L x W x H). Weight approx. 190 kg.
The machine can be demonstrated on site by appointment. We only offer machines that are ready for demonstration in our warehouse; see 'More offers from this seller.'
Listing

1,094 km
Emissions test chamber
VötschVCE 200
Call
Condition: used, Description: Emission Test Chamber
Manufacturer: Vötsch
Hjdpfx Agjxg Hrqo Nefn
Model: VCE 200
Test chamber volume: 200 liters
Temperature range: +20°C to +130°C
Humidity range: 30 to 95% RH
Temperature deviation: temporal ± 0.3 K
Temperature deviation: spatial ± 0.5 K
Average temperature change rate: cooling approx. 0.3 K/min, heating approx. 0.4 K/min
Dew point range: +5°C to 60°C
Humidity deviation: temporal ± 1 to 3% RH
Voltage: 3/N/PE AC 400V±10% 50Hz
Rated power / rated current: 21 kW / 41 A
Refrigerant: R404A
Internal test chamber dimensions: 610 x 610 x 560 mm (W/D/H)
Overall dimensions: 1250 x 1700 x 2350 mm (W/D/H)
Weight: approx. 750 kg
Item Condition:
Used item as shown in the pictures
Please contact us if you have any questions
Shipping:
The quoted shipping costs apply to deliveries within Germany
Worldwide shipping available (please inquire for shipping costs outside Germany)
The given shipping costs apply to shipping within Germany
Sale exclusively to business customers, without warranty or guarantee.
Deviations from technical data and errors in the item description may occur and are reserved.
Listing

785 km
Climate test chamber -10°C to +90°C
VötschVC 0018
Call
Condition: used, Vötsch
Model: VC 0018
Air-cooled climate test chamber
Test chamber dimensions: Width 580 x Depth 450 x Height 750 mm
Housing dimensions: Width 865 x Depth 1150 x Height 1780 mm
Test chamber volume: approx. 190 liters
Performance data for temperature tests:
Temperature range: -10 °C to +90 °C
Temperature deviation in steady-state, according to IEC 60068-3-5,
Hfodpfsw Swrtsx Ag Non
dependent on test chamber temperature
time-wise ±0.1 to ±0.5 K
spatially ±0.5 to ±2.0 K
Temperature change rate according to IEC 60068-3-5
Heating: 0.6 K/min.
Cooling: 0.3 K/min.
Heat compensation in the range +20 °C to +50 °C: 200 W
Calibration values: +4 °C and +90 °C
Performance data for climatic tests:
Temperature range: +10 °C to +90 °C
Temperature deviation in steady-state, according to IEC 60068-3-5,
dependent on test chamber temperature
time-wise ±0.1 to ±0.3 K
spatially ±0.5 to ±1.0 K
Humidity range: 10% to 98% r.h.
Electrical connection:
Rated voltage: 1/N/PE AC 230V ±10% 50Hz
Rated power: 1.7 kW
Rated current: 9.5 A
(Neutral conductor plug: loaded)
Schuko approx. connection cable: 3.5 m
Fuse protection: 16 A slow-blow, provided by the customer
Weight: approx. 380 kg net
Refrigerant: R-134A
Buyer Information for Your Safety!
The following procedures are carried out on our climate chambers prior to sale:
1. Function check and replacement of necessary components
2. If required, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See picture)
Technical specifications and information subject to change and errors!
Feel free to call us with any further questions.

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing

777 km
Climate test chamber with seat pulsator
WeissSD 1400/+20 DU
Call
Condition: good (used), Weiss Climatic Test Chamber with Seat Pulsator
Manufacturer: Weiss
Type: SD 1400/+20 DU
Test Chamber:
Material: Stainless steel
Dimensions
Height approx. 800 mm
Width approx. 2000 mm
Depth approx. 900 mm
Capacity: 1440 liters
Outer casing
Material: Double-coated Zincor sheet
Dimensions
Height approx. 2000 mm
Width approx. 2200 mm
Depth approx. 2000 mm
HxWxD 2000 x 2200 x 2000 mm
Paint finish: Light gray (RAL 9002)
Double-leaf door: hinged on the left and right
Equipment:
Tubing in the floor and ceiling: 2 each, NW 100 mm, for installing the pulsator tables
Tubing in the the side walls: 1 each, left and right, 100 mm
Cooling unit: Air-cooled
Control: Digital measurement and control system DMR
Basic control panel: Integrated into the main switch panel
Interface: RS 232 C, for connection to a PC
Software: Operating software for MS Windows
Performance data:
Temperature range without air conditioning: +20...+100 °C
Temperature stability without air conditioning: +0.2 ... t0.5 K (over time) depending on the range, in steady state
Temperature range with air conditioning: 20...+95 °C
Hedpfx Aoxbgrgsg Njfn
Temperature stability with air conditioning: +0.2 ... +0.5 K (over time) depending on the range, in steady state
Dew point range: 20...+94 °C
Humidity range: 10...98 % RH
Humidity stability: +3 ... +5 % RH depending on the range, in steady state
Temperature change rate measured in the exhaust without a test specimen and without load
- Cooling: 0.5 K/min on average, between +100 and +20 °C
⁃ Heating: 0.5 K/min. On average, between +20 and +100 °C
The performance specifications refer to an ambient temperature of max. +25 °C and the specified nominal voltage.
For proper operation of the system, the ambient temperature must be between +10 and +35 °C.
Seat test device with steel construction for placing and attaching to the climatic test chamber, including:
• 2 pneumatic weight lifting devices (150 mm stroke) for changing test specimens, 12 weights of 5 kg each
• 1 base frame in mild steel welded construction for attaching to the underside of the climatic test chamber. This frame is equipped with removable panels on all sides and has two hinged doors for adjusting the eccentricity. These doors have safety switches.
• 2 eccentric discs with bearings and tachometer, 2 connecting rods, 2 ball bearings,
• 2 mounting tables, perforated, 20 mm grid, 650 x 650 mm, for attaching the test specimens, made of aluminum, thickness min. 10 mm
• 2 mounting plates, perforated, 20 mm grid, 200 x 200 mm, for attaching the buttocks simulation
• 2 stainless steel 60° load rods (The connection to the test specimen is not included in our price, but can be offered subsequently upon precise specification.)
• 2 three-phase motors, 2 belt drives with tensioning devices,
• 1 pneumatic control unit with 2 manual valves, a filter-regulator unit, and a shut-off valve. 1 electrical control cabinet with 2 SEW frequency converters, hand switches, emergency stop button, 2 on/off switches, 2 speed indicators, 2 potentiometers for speed adjustment, 2 pre-selected load changers with zero position and shutdown.
Technical specifications:
Frequency: 100-1000 strokes/minute
Load: 2 x 45 g
Stroke: 0-40 mm
Load from above: 450 N each
You can find more items - new and used - in our shop!
International shipping costs upon request!
Listing

1,548 km
Memmert HPP 260 climatic chamber
MemmertHPP 260
Call
Condition: excellent (used), The chamber is in very good condition and fully functional.
Manufacturer's description:
Temperature
Setting temperature range:
- Without light, with humidity: +5 to +70 °C
- With light, with humidity: +5 to +70 °C
Hsdpsxkzx Hofx Ag Njfn
- With light, without humidity: 0 to +70 °C
- Without light, without humidity: 0 to +70 °C
Working temperature range:
- With light, with or without humidity: +15 to +40 °C
- Without light, with humidity: +5 (at least 20 below ambient temperature) to +70 °C
- Without light, without humidity: 0 (at least 20 below ambient temperature) to +70 °C
Humidity
Setting range: 10 – 90% RH
Control technology
HeatBALANCE Function – adapts the distribution of heating power between the upper and lower heating circuits from -50 % to +50 %
Standard equipment:
- Works calibration certificate at standard values +10 °C and +37 °C, 60 % RH at +30 °C
- Door: Fully insulated stainless steel, 2-point locking (compression door lock)
- Inner glass door
Electrical data:
- Voltage / Electrical load: 115 V, 50/60 Hz, approx. 920 W
Packing/shipping data:
- Dimensions (incl. packaging): 930 x 1380 x 930 mm (W x H x D)
- Gross weight (packaged): approx. 173 kg
Listing

394 km
Environmental test chamber
ESPECESX-2CA
Call
Condition: used, Year of construction: 2005, functionality: limited functionality, machine/vehicle number: ENZ 6CAL, Equipment: CE marking, Used, Working environmental chamber, ESPEC ESX-2CA, Air cooled, Although this model has humidity function, This has been disabled & is now only a temperature only, -70C to +150C, Cooling rate 4.0C per min.
Hedpfx Aewy Uq Rog Nsfn
Internal dimensions (W,D,H) 500mm, 600mm, 750mm. Comes with calibration.
Listing

785 km
Temperature test chamber –70 °C to +180 °C
CTSTS-70/1150-10 -10 K/min
Call
Condition: excellent (used), CTS
Type: TS-70/1150-10
CTS Temperature Test Chamber, Water-Cooled
Control: 32-bit Controller
LCD Operating Panel
Digital Display of Set and Actual Values
Numerical Input of Set Points
Error Messages in Plain Text
Hjdpfxew R Tuno Ag Njfn
RS 232 Interface
Ethernet Interface
Free control channels for customer-side DUT (device under test) actuation
Operation: capacitive touch display & PC-based control (USB/Ethernet)
Test Chamber Dimensions: Height approx. 1250 mm / Width approx. 1000 mm / Depth approx. 920 mm
External Dimensions: Height approx. 2000 mm / Width approx. 1800 mm / Depth approx. 1600 mm
Temperature Testing:
Temperature Range: -70°C to +180°C
Temperature Deviation: ≤ ±0.5 K over time
Temperature Change Rate according to IEC 60068-3-5
Heating: 10 K/min
Cooling: 10 K/min
Thermal Load: approx. 5000 W at -20°C
Technical data refer to an ambient temperature of +25°C
Test Volume (interior): approx. 1150 liters
Operating Data:
Electrical Connection
Nominal Voltage: 400V 3/N 50Hz
Power: 27.6 kW
Nominal Current: 47.5 A
Refrigeration System: Two-stage
R404A (17.8 kg) + R23 (5.4 kg)
Weight: approx. 1500 kg
The following steps are completed on our offered chambers in advance:
1. Function check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Subject to change and error in technical data and information!)
We are happy to answer any further questions you may have by phone.
Listing

777 km
Weathering test device Test chamber
HeraeusXenotest 1200 CPS
Call
Operating hours: 3,888 h, condition: good (used), Heraeus Xenotest 1200 CPS weathering tester
Xenon device for testing the lightfastness and weather resistance of materials under simulated conditions
Electrical connection
Voltage: 400 V
Nominal current: 50 A max.
Connected load: 33 kVA max.
Power consumption of xenon lamps: 2.8 - 6 kW per lamp
Compensation: 3 capacitors, 50 uF each
Operating hours: 3888
Hedpfxjxal Hao Ag Nefn
You can find more items - new and used - in our shop!
International shipping costs on request!
Listing

785 km
Temperature test chamber -70°C to +180°C
VötschVT 7021
Call
Condition: excellent (used), Heraeus Vötsch
Type: VT 7021
Air-cooled temperature test chamber
Hodpfx Agew Rz Tls Njfn
1 port, nominal width 80 mm,
Test chamber volume: 210 liters
Temperature range: -70°C to +180°C
Temporal temperature deviation: ± 0.2 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate (heating): 2.5 K/min
Temperature change rate (cooling): 2.5 K/min
Max. heat compensation: 800 W
Test chamber dimensions: Width 560 mm, Depth 570 mm, Height 630 mm
External dimensions: Width 850 mm, Depth 1250 mm, Height 1640 mm
Electrical connection: 1/NPE AC 230 V ± 10% 50 Hz
Rated power approx. 1.8 kW, rated current 12 A
Refrigerant: R404A and R23
Weight: 355 kg
For your safety as a buyer, please note the following information!
The following procedures are performed on the chambers we offer, in advance:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant, if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see picture)
(Subject to technical modifications and errors in the details!)
For further questions, please feel free to contact us by phone.
Listing

777 km
Large-scale climate test chamber
VötschVCZ 04032
Call
Condition: good (used), Large-scale system for climate tests with S!MCON control
Design
The system consists of the following main components:
- Walk-in, insulated test room
- Air treatment room
- Machine unit
- Air conditioning system
- Control cabinet
Test room
The fixtures in the test room are made of corrosion-resistant material.
The test room can be illuminated, is walk-in, and has a condensate and cleaning drain.
Air treatment room
The air treatment room is located behind the air baffle in the insulated interior.
It contains the following components necessary for temperature control and is accessible via easily removable panels.
- Test room fans
- Heat exchangers
- Electric heaters
- Ventilation and exhaust system
- Temperature sensors
In the air treatment room, the air is tempered (cooled/heated), humidified and dehumidified, and circulated by fans.
The air is drawn in under the ceiling and expelled at floor level.
Sensors
The temperature and humidity sensors are located behind the air baffle in the air treatment room.
Machine Unit
The machine unit, consisting of refrigeration units, supplies the air treatment room with the required energy.
Climate System
The climate system consists of:
- Steam humidifier
- Dehumidification evaporator
Technical Data
Test chamber volume: approx. 32 m³
Direct temperature range: -40 to +100°C
Temperature fluctuation over time in the center of the usable space: +/- 0.5 to +/- 1
Temperature change rate
Heating: from -35°C to +50°C at 3 K/min
Cooling: from +85°C to +85°C at 2 K/min
from +80°C to -40°C at 1 K/min
Data for climate testing
Temperature range: 10 to 95°C
Humidity range: 10 to 95% RH
Dew point range: 5 to 93°C
Temperature fluctuation: +/- 5°C
Humidity fluctuation: +/- 3 to +/- 5% RH
Cooling water specifications
Connections
Inlet: 2 x 1 1/2" RH
Return: 2 x 1 1/2" RH
Consumption at full load: max. 16 m³/h
Maximum load on the test chamber floor: 10,000 N/m²
Hfodpfew U Sv Esx Ag Njn
Nominal voltage: 3/N / PE AC 400 V 50 Hz
Nominal power: 97 kW
Nominal current: 148 A
Dimensions:
Test chamber: Width 3.60 m, Height 2.20 m, Depth 5 m
Climate chamber divided for transport at a specified location (approx. 2.50 m).
Find more items – new and used – in our shop!
International shipping costs on request!
Listing

785 km
Climate test chamber 1300 liters with humidity control
VötschVCS 7130-15 -70°C bis +180°C
Call
Condition: good (used), Vötsch
Model: VCS 7130-15
Vötsch Climate Test Chamber, Water-Cooled
Temperature Test Data:
Temperature range: -70°C to 180°C
Temporal temperature deviation at center of workspace: ±0.3 to ±0.8 K
Spatial temperature deviation: ±0.5 to ±2 K
Temperature gradient: 1 to 4 K
Temperature change rate:
Heating: 16 K/min
Cooling: 14.5 K/min
Climate Test Data:
Temperature range: +10°C to +95°C
Humidity range: 10 to 98% RH
Temporal temperature deviation at center of workspace: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1 K
Temperature gradient: 1 to 2 K
Temporal humidity fluctuation at center of workspace: ±1 to ±3% RH
Maximum heat compensation: 8000 W
Enclosure dimensions:
External dimensions with hinges and door lock:
Height: 1995 mm, Width: 1680 mm, Depth: 1855 mm
External dimensions without hinges and door lock:
Height: 1995 mm, Width: 1300 mm, Depth: 1855 mm
Internal dimensions:
Height: 950 mm, Width: 1100 mm, Depth: 950 mm
Test chamber volume: approx. 1300 liters
Feedthroughs:
The test chamber is equipped with feedthroughs on both the right and left sides. These allow for test leads and testing devices to be routed into the chamber.
1 x R1 NW 125 mm
1 x R1 NW 140 mm
1 x L1 NW 50 mm
Test chamber illumination:
Halogen bulb 24V, 50W
Power supply: 3/N/PE AC 400V ±10% 50Hz
Rated power: 44.0 kW
Rated current: 63.0 A
Customer-provided fuse: 100 A slow-blow
Maximum heat output to the environment: 2.2 kW
Permissible test item weight:
Total load on shelf supports: 100 kg
Test chamber floor: 150 kg, Removable shelf: 50 kg
Refrigerants: R 404A/R 23
Weight: 1900 kg
For your security as a buyer, please note:
The following steps are carried out in advance on our chambers offered for sale:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Subject to changes and errors in the technical data and specifications!)
We are happy to answer any further questions by phone.
Hodpfxswvgwbe Ag Nefn
Listing

777 km
Climate test chamber
EspecPR-3KP
Call
Condition: good (used), operating hours: 75,383 h, Espec PR-3KP Environmental test chamber -20 to +100 °C
Features:
Manufacturer: Espec
Type: PR-3KP
Temperature range: -20 to +100 °C
Humidity: 20 to 98 % rH
Refrigerant R-404A:- CFC-free - ozone-friendly
Operating hours: 75383
Dimensions:
External dimensions: HxWxD= 1680 x 1050 x 1200 mm
Hfjdpfowbz Hhox Ag Non
Chamber dimensions: HxWxD= 850 x 600 x 800 mm
Further items in other sizes - new and used - can be found in our store!
International shipping costs on request!
Listing

785 km
Temperature test chamber 190 liters
VötschVT 7018 -70°C bis +180°C
Call
Operating hours: 630 h, condition: excellent (used), Vötsch
Model: VT 7018
Air-cooled temperature test chamber
Only approx. 630 operating hours (read out)!
Test chamber dimensions: Width 580 x Depth 450 x Height 750 mm
External dimensions: Width 865 x Depth 1280 x Height 1780 mm
Test chamber volume: approx. 190 liters
Technical specifications for temperature tests:
Temperature range: -70 °C to +180 °C
Temperature deviation in steady state, according to IEC 60068-3-5
depending on the test chamber temperature
temporal ±0.1 to ±0.5 K
spatial ±0.5 to ±2.0 K
Temperature change rate according to IEC 60068-3-5
Heating: 4 K/min.
Cooling: 2.3 K/min.
Thermal compensation max. 1000 W
Tube port L1: DN 50 mm
Tube port L2: DN 125 mm
Tube port R1 R2: DN 125 mm
Electrical connection:
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 5.9 kW
Rated current: 12 A
Hsdpfx Aew Nqimeg Nofn
Protection: 16 A time-lag, to be provided by customer
Weight: approx. 460 kg net
Refrigerants: R 404A and R 23
Important safety information for you as a buyer!
The following points are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (See image)
(Subject to change and errors in technical data!)
We are happy to answer further questions by phone.
Listing

785 km
Climate test chamber 600 liters with humidity
WeissWK3-600/70 -70°C bis +180°C
Call
Condition: excellent (used), Weiss
Model: WK3-600/70
Climate Test Chamber, Water-cooled
Specifications for temperature testing:
Temperature range: -70°C to +180°C
Temperature change rate:
Heating: 4.0 K/min
Cooling: 2.5 K/min
Temperature deviation:
Temporal: ±0.1 to ±0.5 K
Spatial: ±0.5 to ±1.5 K
Heat compensation: max. 2500 W
Specifications for climate testing:
Temperature range: +10 to +95 °C
Dew point temperature range: -3 to +94°C
Humidity range: 10 to 98% r.h.
Temperature deviation (temporal): ±0.1 to ±0.3 K
Temperature deviation (spatial): ±0.5 to ±1 K
Humidity deviation (temporal): ±1 to ±3% r.h.
Temperature uniformity (spatial): ±0.5 to ±1.0 K
Heat compensation: max. 500 W
Test chamber volume: 600 liters
Test chamber dimensions (H x W x D): 950 mm x 800 mm x 800 mm
External dimensions (H x W x D): 1998 mm x 1000 mm x 1745 mm
Feedthrough diameters: NW 125 mm and NW 50 mm
Operating data:
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal power: 9.1 kW
Nominal current: 19.0 A
Refrigerant: R 452A & R23
Weight: 680 kg
Important safety information for buyers!
The following procedures are carried out on all chambers we offer prior to delivery:
1. Functional check and replacement of necessary components
2. If necessary, the chamber is refilled with refrigerant in compliance with applicable laws
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Hsdjw Nqhpjpfx Ag Nefn
Scope of delivery: (See image)
(Specifications subject to change and possible errors!)
If you have further questions, feel free to call us.
Listing

785 km
Climate test chamber 600 liters
WeissWK3-600/70 -70°C bis +180°C
Call
Condition: good (used), Weiss
Type: WK3-600/70
Climate Test Chamber, Water-Cooled
Specifications for Temperature Testing:
Temperature range: -70°C to +180°C
Temperature change rate:
Heating: 4.0 K/min
Cooling: 2.5 K/min
Temperature deviation:
Over time: ±0.1 to ±0.5 K
Spatially: ±0.5 to ±1.5 K
Heat compensation max.: 2,500 W
Specifications for Climate Testing:
Temperature range: +10 to +95 °C
Dew point temperature range: -3 to +94°C
Humidity range: 10 to 98 % rH
Temperature deviation over time: ±0.1 to ±0.3 K
Temperature deviation spatially: ±0.5 to ±1 K
Humidity deviation over time: ±1 to ±3 % rH
Temperature uniformity (spatial): ±0.5 to ±1.0 K
Heat compensation max.: 500 W
Test chamber volume: 600 liters
Test chamber dimensions: Height 950 mm, Width 800 mm, Depth 800 mm
External dimensions: Height 1,998 mm, Width 1,000 mm, Depth 1,745 mm
Hsdpow Inmmsfx Ag Njfn
Operating Data:
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 9.1 kW
Rated current: 19.0 A
Refrigerant: R404A & R23
Weight: 680 kg
Important information for you as the buyer:
The following points are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After a successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See picture)
(Specifications subject to change. Errors and omissions excepted!)
If you have any further questions, we are happy to answer them by phone.
Listing

785 km
Salt spray chamber corrosion test cabinet
VLMCC 1000-FL HL V.745.672.430 1000 Liter
Call
Condition: excellent (used), VLM
Type: V.745.672.430 Model CC 1000-FL HL
Corrosion Test Chamber for Salt Spray Tests
Hfodpfx Agsw H Aatj Non
Specifications:
Test Chamber Volume: approx. 1000 L
Test Chamber Dimensions (W x D x H1/H2): 1400 x 800 x 800/1020 mm
Door Opening Dimensions (W x H): 1300 x 680 mm
External Housing Dimensions (W x D x H): 2162 x 995 x 2080 mm
Operating Temperature Range: 5°C above ambient to +80°C
Heavy-duty Version for loads up to 350 kg
Process Control: Beckhoff PLC, Color Touchscreen Display, 50 program memory locations for test procedures, 50 memory locations for test segments, ramps: humidity-temperature throughout the entire working range, Ethernet connection
Electrical Connection: 400 V, 50 Hz, 5900 W
Mains Water: at least 2.5 bar, 3/4" tap connection with external thread for ion exchanger cartridge connection
Compressed Air: 7–8 bar
Wastewater: Siphon / 30 mm ID hose nozzle
Exhaust Air: Pipe end AD 75 mm
Operating Modes:
- Salt spray
- Condensed water (CWC)
- Chamber air ventilation
- Warm air
- Controlled humidity
Listing

785 km
Climate test chamber -10°C to +90°C
VötschVC 0018
Call
Condition: used, Vötsch
Model: VC 0018
Climate Test Chamber, Air-Cooled
Test Chamber Dimensions: Width 580 x Depth 450 x Height 750 mm
External Dimensions: Width 865 x Depth 1150 x Height 1780 mm
Test Chamber Volume: approx. 190 liters
Specifications for Temperature Testing:
Temperature Range: -10°C to +90°C
Temperature Deviation at steady state, according to IEC 60068-3-5,
depending on chamber temperature
over time: ±0.1 to ±0.5 K
spatial: ±0.5 to ±2.0 K
Temperature Change Rate according to IEC 60068-3-5
Heating: 0.6 K/min
Cooling: 0.3 K/min
Heat compensation in the range +20°C to +50°C: 200 W
Calibration Points: +4°C and +90°C
Specifications for Climate Testing:
Temperature Range: +10°C to +90°C
Temperature Deviation at steady state, according to IEC 60068-3-5,
depending on chamber temperature
over time: ±0.1 to ±0.3 K
spatial: ±0.5 to ±1.0 K
Humidity Range: 10% to 98% RH
Electrical Connection:
Rated Voltage: 1/N/PE AC 230V ±10% 50Hz
Rated Power: 1.7 kW
Rated Current: 9.5 A (neutral conductor plug loaded), Schuko approx. connection cable: 3.5 m
Protection: 16 A slow-blow, provided by the customer
Hfsdsw Hz S Uopfx Ag Njn
Weight: approx. 380 kg net
Refrigerant: R 134A
For your safety as a buyer, please note the following information!
The following points are carried out on all climate chambers we offer prior to delivery:
1. Functional check and replacement of necessary components
2. If necessary, a refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See picture)
(Specifications and technical data are subject to change and errors are excepted!)
We are happy to answer any further questions you may have by phone.
Listing

785 km
Climate test chamber 1540 liters
WeissWK1-1500/40 Temp. -40°C bis +180°C
Call
Condition: used, Weiss
Type: WK1/1500/40
Weiss Climate Test Chamber, Air-Cooled with Humidity Control
(converted to use refrigerant R-452a)
Temperature range: -40°C to +180°C
Cooling rate approx. 2.5 K/min, heating rate approx. 3.5 K/min
Temporal temperature deviation at center of test space: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature range: +10°C to +95°C
Humidity range: 10% to 98% r.H.
Temporal temperature deviation at center of test space: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Heat compensation
In the range of +25°C to +95°C, at a relative humidity up to 90%: 500 W
Test chamber dimensions: Height: 950 mm, Width: 1100 mm, Depth: 1475 mm
External dimensions: Height: 2005 mm, Width: 1300 mm, Depth: 2450 mm
Test volume: approx. 1540 liters
Test chamber lighting: Halogen bulb 12V, 50W
Rated voltage: 3/NPEAC 400V ±10% 50Hz
Rated power: 11.5 kW, Rated current: 22.0 A
Fuse on site: 32A slow-blow
Protection class (control cabinet and operator panel): IP 54
Refrigerant: R-452a
Weight: 920 kg
For your safety as a buyer, please note the following information:
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant
3. Leak test with certificate
Hjdow Hcttepfx Ag Njfn
4. After successful inspection, the chambers undergo a test run, monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Technical specifications subject to change and errors excepted!)
If you have further questions, we will be happy to answer them by phone.
Listing

785 km
Temperature test chamber 1540 liters
VötschVT³ 4150 -40°C bis +180°C
Call
Condition: excellent (used), Vötsch
Model: VT³ 4150
Vötsch Temperature Test Chamber, Air-Cooled
Temperature Testing
Temperature Range: -40°C to +180°C
Rate of Change: Cooling approx. 2.5 K/min
Rate of Change: Heating approx. 3.5 K/min
External Dimensions (W x D x H): approx. 1390 x 2380 x 1995 mm
Test Chamber Dimensions (W x D x H): approx. 1100 x 1475 x 950 mm
Rated Voltage: 3/N/PE AC, 400 V ±10%, 50 Hz
Rated Power: 11.5 kW
Rated Current: 22.0 A
Weight: approx. 1020 kg / 1540 liters
Refrigerant: R 404A
For your safety as a buyer, please note the following information:
We perform the following steps on all chambers offered:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: Used
Scope of delivery: (see photo)
Hjdpsw Ehutefx Ag Nefn
(Technical data subject to change and errors excepted!)
For further questions, feel free to contact us by phone.
Listing

785 km
Climate test chamber with humidity, 306 liters
EspecPSL-2KPH -70°C bis +150°C
Call
Condition: excellent (used), Espec
Type: PSL-2KPH
Thermo TEC
Espec Temperature and Climate Test Chamber, Air-Cooled
Temperature range: -70°C to +150°C
Humidity range: 20 to 98% rH
Temperature/Humidity Fluctuations: ± 0.3°C / ± 2.5% rH
Temperature/Humidity Stability: ± 0.5°C / ± 3% rH
Heat-up time: from -70°C to +150°C in 50 min
Cool-down time: from +20°C to -70°C in 80 min
Test chamber dimensions: width 600 mm x height 850 mm x depth 600 mm
External dimensions: width 1010 mm x height 1690 mm x depth 1173 mm
Test chamber volume: 306 liters
Hfodpfew D Dgvex Ag Njn
Refrigerants: R-404A, R-508A
Stainless steel construction
Connection: AC 400V 3~ 50/60 Hz Max. 18 A
Rated power: 1.5 kW
Net weight approx. 400 kg
For your safety as a buyer, please note the following information!
The following procedures are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. New charge with legally compliant refrigerant
3. After successful inspection, the chambers undergo a test run, monitored with calibrated instruments.
Condition: used
Scope of delivery: (see photo)
(Technical data and specifications may be subject to change and errors!)
For further questions, please feel free to contact us by phone.
Listing

785 km
Shock test chamber
HeraeusHT 7012 S2
Call
Condition: excellent (used), Here we offer shock test chamber.
Temperature shock test chamber water cooled
Two-chamber design
Warm chamber:
Temperature control of the warm chamber ranges from +50°C to +220°C
Temperature deviation temporally in useful chamber center ± 1 K
Temperature deviation spatially ± 2 K
Temperature change rate
heating 11 K/min
cold chamber:
the cold chamber from -65°C to +70°C
Temperature deviation temporally in useful space center ± 1 K
temperature deviation spatially ± 2 K
Temperature change rate
heating 2 K/min
cooling 3 K/min
Test chamber volume 125 liters
Temperature range hot chamber +50°C to +220°C
Temperature range cold chamber -80°C to +70°C
Test chamber dimensions width 470mm depth 650mm height 410mm
Outer dimensions width 930mm depth 2115mm height 1970+mm
Rated power 10 kW
Rated current 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerant R404A / R23
Operating hours: 27.903 hrs.
Weight: 1000 kg
For you as a buyer, the following information for your safety!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
Hfodpfxoi Az Egs Ag Njn
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Type: HT 7012 S2
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Trust Seal
Dealers certified through Machineseeker

Listing

785 km
Temperature test chamber -70°C to +180°C
VötschVTS 7018-5 190 Liter
Call
Condition: excellent (used), Vötsch
Model: VTS 7018-5
Water-cooled Temperature Test Chamber
System retrofitted with R-452A
Temperature range: -70°C to +180°C
Temporal temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature change rate cooling: 7.5 K/min
Temperature change rate heating: 7.5 K/min
Heat compensation at +20°C: 3000 W
Heat compensation at -20°C: 3000 W
Test chamber dimensions: Width 580 mm, Depth 450 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1280 mm, Height 1575 mm
Test chamber volume: 190 liters
Rated voltage: 3/N/PE AC, 400V ±10%, 50Hz
Rated power: 10.0 kW, Rated current: 21 A
Main fuse (on-site): 32 A slow-blow
Sound level at 1m distance (free-field measurement): < 69dB (A)
Side port: 50 mm / 125 mm
Hfjdpjwq Iymefx Ag Non
Chamber is water-cooled
Refrigerants: R-452A and R 23
Weight approx. 460 kg
For your safety as a buyer, the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If required, new charging with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (See picture)
(Technical data may be subject to change or error!)
If you have any further questions, we will be happy to answer them by phone.
Listing

785 km
Climate test chamber with humidity, 800 liters
EspecPSL-4KPH -70°C bis +150°C
Call
Condition: excellent (used), Espec
Type: PSL-4KPH
Espec Temperature and Climate Test Chamber, Air-Cooled
There is a small dent at the top edge of the door (see photo).
The door closes perfectly, the seal is intact, and the climate chamber operates without any technical faults.
The dent is purely cosmetic and does not affect function, sealing, or control accuracy in any way.
Temperature range: -70°C to +150°C
Humidity range: 20 to 98% relative humidity
Temperature/Humidity fluctuations: ±0.3°C / ±2.5% r.H.
Temperature/Humidity stability: ±0.5°C / ±3% r.H.
Heating/Cooling rates and times:
- Heating time: within 30 min from +20 → +100 °C
- Cooling time: within 115 min from +20 → –40 °C
- Heating rate: 3.0 °C/min
- Cooling rate: 1.0 °C/min
Test chamber dimensions: Width 1000 mm x Height 1000 mm x Depth 800 mm
External dimensions: Width 1410 mm x Height 1983 mm x Depth 1593 mm
Port with silicone plug: 100 mm
equipped with RS232 interface
Test chamber volume: 800 liters
Hfodpswz Er Uofx Ag Nen
Refrigerants: R-404A, R-508A
Stainless steel construction, AC 400 V 3φ, 50Hz 31 A
Net weight approx. 720 kg
For your safety as a buyer, the following measures are performed in advance on our offered chambers:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. Upon successful inspection, the chambers undergo a test run monitored with calibrated devices.
Condition: used
Scope of delivery: (see photo)
(Subject to change and error in technical data and specifications!)
We are happy to answer further questions by phone.
Listing

785 km
Shock test chamber -80°C to +220°C
VötschVT 7012 S2
Call
Condition: excellent (used), Vötsch
Hfedpfxswzilre Ag Non
Type: VT 7012 S2
Water-cooled
Two-chamber design
Hot chamber:
The temperature range of the hot chamber is from +50°C to +220°C.
Temperature deviation over time in the center of the chamber is ± 1 K.
Temperature deviation over space is ± 2 K.
Temperature change rate:
Heating: 11 K/min.
Cold chamber:
The temperature range of the cold chamber is from -80°C to +70°C.
Temperature deviation over time in the center of the chamber is ± 1 K.
Temperature deviation over space is ± 2 K.
Temperature change rate:
Heating: 2 K/min.
Cooling: 3 K/min.
Test chamber volume: 125 liters.
Hot chamber temperature range: +50°C to +220°C.
Cold chamber temperature range: -80°C to +70°C.
Test chamber dimensions: Width: 470 mm. Depth 650mm Height 410mm
External dimensions: Width 930mm Depth 2115mm Height 1970+mm
Plug-in diameter 67mm
Voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power 10 kW
Rated current 25 A
Refrigerant R404A / R23
Weight: 1000 kg
For your safety, the following information is provided as a buyer!
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing

785 km
Temperature test chamber 990 liters
VötschVT³ 4100 -40°C bis +180°C
Call
Condition: excellent (used), Vötsch
Model: VT³ 4100
Water-Cooled Temperature Test Chamber
S!MCON/32.NET (with Touch Panel)
Control System Features:
- Color touchscreen with intuitive menu navigation (typically 5.7" or larger)
- Programming of temperature/humidity profiles with ramps and dwell times
- Data acquisition & logging (e.g., temperature profile, alarms)
- USB port for data export (CSV, optionally S!MPATI compatible)
- Network interface (Ethernet) for remote monitoring and control
- User management with password protection
- Interfaces: Volt-free contacts, optionally Modbus or Profibus
VT³ 4100 – Technical Specifications (Temperature Test Chamber)
- Test volume: 990 liters
- Temperature range: -40 °C to +180 °C
- Temporal temperature deviation: ±0.1 to ±0.5 K
- Spatial temperature deviation: ±0.5 to ±1.5 K
- Temperature gradient: 1 to 3 K
- Temperature change rate (per IEC 60068-3-5):
• Heating: 4.0 K/min
• Cooling: 3.0 K/min
- Maximum heat compensation capacity: 4500 W
- Calibration values: +23 °C and +80 °C
- Internal dimensions (W×D×H): 1100 × 950 × 950 mm
- External dimensions (W×D×H): 1390 × 1955 × 1995 mm
Feed-Throughs:
The chamber is equipped with feed-throughs on both the right and left sides, allowing insertion of measuring cables and test devices into the test space.
• 1 × L1 nominal width 50 mm
• 1 × R1 nominal width 125 mm
• 3 × R1 nominal width 50 mm
Electrical connection: 3/N/PE AC, 400V ±10%, 50Hz
Power consumption: 11.5 kW
Hfjdpfx Aowyu H Esg Non
Rated current: 22 A
Noise level: approx. 62 dB(A)
Refrigerant: R452A
Weight: 920 kg
Important information for buyers:
For your security, the following measures are carried out on all our offered chambers prior to sale:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant, if needed
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run
Condition: used
Scope of delivery: (see picture)
(Subject to change and errors in technical data; information may be subject to alteration!)
For any further questions, feel free to contact us by phone.
We make it easier for you to find: "climatic test chamber"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Climatic Test Chamber (16,143)
Search Machineseeker now with more than 200,000 used machines:Browse through the most popular machine descriptions:
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month